Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

Similar documents
Gas Chromatograph Mass Spectrometer

Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

Gas Chromatograph Mass Spectrometer

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

C146-E209. Headspace Samplers. HS-20 Series

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Highly Sensitive and Rugged GC/MS/MS Tool

Agilent 5977A Series GC/MSD System

Translational Biomarker Core

Thermo Finnigan LTQ. Specifications

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Gas Chromatograph Mass Spectrometer GCMS-QP2020 NX C146-E367

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Analytical Instrumentation

Protein Sequencer PPSQ-31A / 33A C297-E055B

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Screening of pesticides in water using SPE on line

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

Finnigan LCQ Advantage MAX

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Fast and Accurate Analysis of Fluorotelomer Alcohols and Acrylates using Triple Quadrupole GC-MS/MS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

HYPHENATED TECHNOLOGY GUIDE

Agilent G3212 GC-APCI Source

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

HYPHENATED TECHNOLOGY GUIDE

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Identifying Disinfection Byproducts in Treated Water

WADA Technical Document TD2003IDCR

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Gas Chromatograph Mass Spectrometer GCMS-QP2020 C146-E295A

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Finnigan TRACE DSQ GC/MS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Single Nano Particle Size Analyzer

Pittcon P

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Introduction to the Q Trap LC/MS/MS System

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Multi-residue analysis of pesticides by GC-HRMS

U.S. EPA Method 8270 for multicomponent analyte determination

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

TOXICOLOGY & FORENSIC APPLICATIONS

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

GCMS-QP2020. Gas Chromatograph Mass Spectrometer. C146-E295. Printed in Japan XXX

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Electron Ionization Source Parameters in GC-MS

Theory and Practical Consequences.

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Consumables Guide for the Cannabis Testing Lab

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Extrel is widely respected for the quality of mass spectrometer systems that are

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

TO-15 Checklist Determination of VOCs in Air by GC-MS

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

2401 Gas (liquid) Chromatography

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Defining quality standards for the analysis of solid samples

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Activity in the FID Detection Port: A Big Problem if Underestimated

Select the appropriate PM to be done and then perform the checklist under that section.

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Transcription:

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

with Smart Abilities

Enhanced Sensitivity Leads to New GC-MS/MS Possibilities The GCMS-TQ8050 features a new highly efficient detector and three noise-reduction technologies that enable femtogram-level quantitative analysis. Also, the increased instrument robustness and safety provide dramatically improved reliability for ultra-trace analysis. Enhanced Sensitivity A new detector with better amplification performance maximizes the benefits of the OFF-AXIS Ion Optics, which offers both high ion transmission performance and outstanding noise elimination performance. These state-of-the-art technologies enable the system to reliably detect ultra-trace quantities of ions, down to the femtogram level, achieving the world's highest * sensitivity levels. * As of August 2016, according to a Shimadzu survey. 4

Durable Hardware In addition to high sensitivity, the system offers highly robust performance. The contamination-resistant ion source and the new detector with over five times longer service life ensure reliable, long-term analysis. An oil-free pump that can be operated for three years without maintenance is also available. Superior Performance A new turbomolecular pump with higher evacuation performance achieves a superior vacuum state in the MS unit. This results in higher sensitivity and stability and helps improve analysis accuracy for ultra-trace concentration levels. Using the ultra-fast analysis technology (UFsweeper) offered in existing models, the system can simultaneously analyze samples using multiple modes, such as high-speed scanning and scan/mrm modes. Reliable Operation The Smart MRM technology that optimizes sensitivity helps accurately create methods for ultra-trace analysis and ensures high sensitivity for MRM measurements. In addition, the enhanced accuracy control function provided by LabSolutions Insight software improves the reliability of analyzing data acquired from simultaneous multicomponent analysis of ultra-trace components. GCMS-TQ8050 Gas Chromatograph Mass Spectrometer 5

Enhanced Sensitivity The new GCMS-TQ8050 triple quadrupole mass spectrometer has been created based on continuously advancing Smart technologies that go beyond what was previously possible. The resulting exceptional analytical sensitivity and robustness increase the value of solutions and open the door to new applications. The newly designed high-sensitivity detector offers excellent reliability even for samples with femtogram-level concentrations of trace components, achieving sub-femtogram IDL * levels. *IDL: Instrument Detection Limit ( 1,000) 5.0 4.5 4.0 3.5 3.0 2.5 2.0 2 fg OFN 8 times IDL: 0.36 fg Quantifiable to femtogram level TQ8050 TQ8040 1.5 1.0 0.5 3.800 3.825 3.850 3.875 3.900 3.925 3.950 3.975 fg/µl pg/µl The superior data stability with the GCMS-TQ8050 provides sensitivity that rivals high-resolution GCMS analysis. This powerful new analytical instrument reliably identifies peaks even for trace quantities of dioxins and other substances previously considered difficult to analyze using a quadrupole GCMS system. 6000 319.90 > 256.90 321.90 > 258.90 303.90 > 240.95 305.90 > 242.95 5000 10000 4000 7500 3000 5000 2000 1000 2500 21.0 22.0 Mass chromatogram of 2,3,7,8-TeCDD (50 fg/µl) 20.0 20.5 21.0 21.5 22.0 Mass chromatogram of 2,3,7,8-TeCDF (50 fg/µl) 6

UF-Transmission High-Sensitivity Detector The GCMS-TQ8050 detects peaks more reliably than previous models, even for substances with fewer ions reaching the detector. That means it can reliably analyze femtogram-level concentrations with fewer ions. GCMS-TQ8050 Previous model OFF-AXIS Ion Optics The OFF-AXIS Ion Optics eliminate noises such as metastable He ions without compromising sensitivity. Shielded Detector Noise from outside the detector was reduced by installing a shield in the secondary electron multiplier. Overdrive Lens Installing two lenses (overdrive lenses) in front of the electron multiplier reduces random noise from helium or argon and improves S/N. Applying voltage to the lenses improves S/N levels by reducing noise near the lenses and helping to focus the ions that pass through the mass filter (Patent No. US6737644). Ion detection signal S/N ratio Noise Sample Noise Applied voltage (V) 1000 Overdrive lens OFF Overdrive lens ON Relationship between voltage applied to overdrive lenses and S/N Noise reduction due to overdrive lenses GCMS-TQ8050 Gas Chromatograph Mass Spectrometer 7

Durable Hardware Reduces maintenance frequency and costs for long-term use. Highly Sensitive and Stable Ion Source The effect of the filament s electric potential on the ion source is reduced by placing more distance between the filament and ion source box. In addition, a shield blocks out radiant heat generated from the filament to ensure the ion source box temperature remains uniform. Since this prevents any active spots within the ion source, it provides higher sensitivity for analysis. (Patent: US7939810) Shield Shield Temperature Low : Filament : Electric field : Heat rays High Long-Life Detector Exhaustive efforts to reduce detector loads during analysis significantly increase the detector's service life. Consequently, the instrument needs to be maintained much less frequently, which also means less downtime. TQ8050 Longer detector life not only in MRM mode, but also in scan mode TQ8050 TQ8040 TQ8040 Scan MRM Oil-Free Pump (Optional) The rotary pump can be replaced with an oil-free pump, which requires no maintenance for three years. This auxiliary vacuum pump not only maintains an oil-free environment inside the vacuum lines, it also eliminates the tedious and time-consuming tasks of replacing and disposing of the oil. Clean exhaust due to dry method using no oil in the pump chambers Year 0 Year 1.5 Year 3 Maintenance-free Overhaul Overhaul Air cooling method using no cooling water Long life with no performance deterioration Maintenance to replace oil Maintenance to replace oil 8

Superior Performance The new turbomolecular pump and high-efficiency collision cell enable a variety of high-sensitivity analyses. New Large-Capacity Differential Vacuum System A more stable vacuum system was achieved by using a new turbomolecular pump that offers higher evacuation efficiency. Consequently, it is able to maintain a high vacuum level even during MRM analysis with a collision gas introduced, which enables highly accurate trace analysis. High-Efficiency Collision Cell UFsweeper Shimadzu's proprietary UFsweeper technology achieves high-speed MRM analysis at speeds up to 800 transitions per second. It sweeps residual ions from the collision cell to provide high-efficiency CID and fast ion transport. Rapid ion removal minimizes cross-talk and enables trace analysis (patent pending). SIM 290.00 MRM 290.00 > 204.00 290.00 > 118.00 15.1 15.2 15.3 15.0 15.1 15.2 15.3 Analysis of residual pesticides (Isoprothiolane 1 pg/µl) Sensitivity and Repeatability in Single GC/MS Mode The high-efficiency ion source provides the foundation of an ion generation and transmission system, which creates and then delivers ions to the detector, resulting in a GC/MS with the maximum possible sensitivity and repeatability. These features are not realized just for MRM measurements by GC-MS/MS, but also for scan and SIM measurements in single quadrupole modes, even with the most reactive compounds. Q1 with post-rod achieves outstanding ion transfer efficiency 100.00 72.00 100.00 72.00 277.00 UFsweeper provides high ion transfer efficiency 12.75 13.00 13.25 13.50 %RSD = 1.76 % 12.75 13.00 13.25 13.50 %RSD = 1.44 % Thiobencarb 5 pg/µl Left: GCMS-QP2020, Right: GCMS-TQ8050 (for RSD determination, n = 5) 79 93 63 125 150 169 214 277 260 247 79 93 63 125 150 169 214 277 260 247 O N O S O P O O 12.25 12.50 12.75 13.00 0 50 100 150 200 250 300 350 Scan mass spectrum of Fenitrothion 0 50 100 150 200 250 300 350 Mass spectrum registered in NIST library GCMS-TQ8050 Gas Chromatograph Mass Spectrometer 9

Reliable Operation High Accuracy from Method Creation to Data Analysis Smart MRM The Smart MRM function automatically creates methods with measurement times optimized for each component. When creating methods for simultaneous multicomponent analysis, the complicated process of configuring measurement parameters made it difficult to prepare appropriate methods. By using the Smart MRM function, however, it is possible to automatically create methods with which data is acquired only during the elution time of the target components. In addition to MRM methods, SIM methods can also be created. Smart Database Information about optimal transitions is preregistered in the Smart Database. That means Smart MRM can be used to create optimized methods without having to evaluate analytical conditions. The Smart Database provides powerful support for performing highly reliable analysis. Environmental Pollutant Analysis Forensic Toxicological Analysis Pesticide Residue Analysis Metabolic Component Analysis In particular, the "Smart Environmental Database" is extremely useful for analysis of environmental pollutants, which require trace analysis. Not only are MRM information and stable isotope labeled compounds (IS) for target analysis components registered in the Smart Environmental Database, but also the optimal columns for separating each compound are set, so trace analysis can be smoothly performed without having to set the conditions for each compound. 6.0 ( 10,000) 5.0 4.0 3.0 2.0 #81 #77 #118 #114 #123 #105 #167 #126 #156 #157 #169 #189 1.0 39.0 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0 Dioxin-Like PCBs (50 fg/µl concentration) 10

Solutions for Analyzing Ultra-Trace Hazardous Substances in Foods and the Environment Dioxins and other persistent organic pollutants (POPs) in foods and the environment are normally detected at femtogram-level concentrations, which requires high sensitivity and high quantitative accuracy. Because the new detector used in the GCMS-TQ8050 can detect much lower quantities of ions than previous models, it is able to analyze femtogram-level concentrations of hazardous substances with high sensitivity. Also, the detector's improved sensitivity provides high accuracy for quantitative analysis of femtogram-level concentrations of hazardous substances. Furthermore, sensitivity and quantitative accuracy were enhanced by making improvements to the input of ions into the detector. Therefore, the GCMS-TQ8050 can be used to analyze ultra-trace concentrations of hazardous substances, which were difficult to analyze using previous GC-MS/MS systems. ( 1,000) ( 10,000) 5.5 5.0 319.90 > 256.90 321.90 > 258.90 1.75 271.80 > 236.90 273.80 > 238.90 %RSD = 6.74% (Injected 6 consecutive times) 4.5 1.50 4.0 3.5 1.25 3.0 1.00 2.5 2.0 0.75 1.5 0.50 1.0 0.5 0.25 19.0 19.5 20.0 20.5 21.0 21.5 2,3,7,8-TeCDD content in fish meat (120 fg/µl quantitation value) 12.25 12.50 12.75 13.00 Heptachlor (50 fg/µl concentration) A type of female hormone, estrogen persists in the environment at low concentrations as an endocrine disruptor, which requires high sensitivity for analysis. To analyze estrogen, it is first derivatized and then a GC/NCI-MS system is used to selectively analyze compounds with high electron affinity. The GCMS-TQ8050 proves its worth in ultra-trace analysis using not only EI, but CI and NCI ionization methods as well. In particular, the GCMS-TQ8050 can analyze femtogram-level concentrations of estradiol, which is one type of estrogen, with high sensitivity and accuracy using NCI. Therefore, it eliminates the previously required step of first concentrating samples. 9.0 8.0 7.0 6.0 5.0 ( 1,000) 343.20 > 253.20 N = 8 %RSD = 7.4% Area 900000 800000 700000 600000 500000 400000 4.0 3.0 2.0 1.0 14.1 14.2 14.3 14.4 14.5 14.6 Mass chromatogram of α-estradiol (50 fg/µl concentration, MRM mode) 300000 200000 100000 0 0 100 200 300 400 Concentration Calibration curve from 5 to 500 fg/µl R 2 0.999 GCMS-TQ8050 Gas Chromatograph Mass Spectrometer 11

LabSolutions Insight Smart Processing of Hundreds of Data Files Multi-analyte Data Review With LabSolutions Insight software, quantitative results for a complete series of data files can be displayed side-by-side for comparison and QC review. All of the chromatograms for a selected target compound can be displayed simultaneously, making it easy to review the detected peaks and confirm the quantitative results. Color-coded QA/QC flags quickly identify any outliers that require further examination. Color-coded Quantitative Flags In LabSolutions Insight, quantitative results can be compared to established criteria, and any outliers are color-coded for easy identification and further review. Five color-coded criteria levels can be defined, making it easy to determine which data points are outliers, and which specific QC criteria were not met. Any changes made to calibration curves or manual peak integration are immediately reflected in the color-coded flags. Status Review Function This function can be used to specify the status of all compounds and samples for their management. By specifying a status, the progress of data analysis work can be accurately recorded and reported. Rerun Pending Accept 12

Enhanced Accuracy Controls Accuracy control results, such as retention time differences, calibration curve linearity and peak shapes (tailing), can be assessed visually. In addition, the QC chart function in LabSolutions Insight allows visual confirmation of variations in target compounds across multiple data sets. This is useful when evaluating variations in internal standard substances between samples, for example. System Configurations Using Multiple Client Computers Data acquired from multiple systems can be reviewed or confirmed using client computers connected via a LAN or other network. If multiple systems are used, data obtained from each system can be reviewed from any client computer. Even in the case of multiple analysts using the same system, the ability to separate analytical work from measurement work improves work efficiency. Laboratory GC/MS analysis LC/MS analysis Operator Operator Office Data review File Server Client PC Analysis administrator Data confirmation Client PC Operator Client PC Operator Client PC Operator File management on a file server is recommended for systems with more than five users. GCMS-TQ8050 Gas Chromatograph Mass Spectrometer 13

Wide Variety of Optional Products for Supporting Trace Analysis Chemical Ionization and Negative Chemical Ionization In addition to commonly-used electron ionization (EI), both chemical ionization (CI) and negative chemical ionization (NCI) are available for the GCMS-TQ8050. The CI mode is a soft ionization technique, used to detect many compounds not possible by EI, and is suited for confirmation of molecular weight. The NCI mode can be used to detect functional groups having a high electron affinity such as halogens. Any of three types of reagent gases (methane, isobutane, or ammonia) can be used. Methyl erucate; C22:1 n-9 EI-GC-MS % C22:1 n-9 ( 1,000,000) 125 55.0 100 7.5 69.0 75 43.0 320.3 5.0 50 25 152.1 236.2 264.3 352.3 2.5 0 100 75 50 50 100 150 200 250 300 350 PCI-GC-MS/MS % 97.2 71.2 149.2 163.2 Precursor m/z 353.3 CE:9V 303.3 321.3 25 247.2 353.3 0 50 100 150 200 250 300 350 400 0.25 320.30 264.00 C20:3 n-3 54.50 54.75 55.00 55.25 ( 10,000) 1.50 321.30>289.30 321.30>271.30 C20:3 n-3 1.25 1.00 0.75 0.50 55.75 56.00 56.25 56.50 HS-20 Headspace Sampler In combination with the HS-20 headspace sampler, the GCMS-TQ8050 can perform quantitative analysis for impurities in pharmaceuticals. In particular for highly toxic compounds for which trace determination is required, accurate quantitative analysis can be carried out down to low concentrations with MRM analysis using the GCMS-TQ8050. AOC-6000 Multifunctional Autosampler For target substances that require femtogram-level trace analysis, it is difficult to perform sample preparation, such as dilution and adding internal standards, due to the high toxicity. The AOC-6000 features a robotic tool changer (RTC) function that performs all steps from adding the internal standard to diluting samples automatically. Using this autosampler allows the user to perform everything from sample preparation to analysis as a continuous process, which can dramatically increase analytical throughput. Internal standard Automatic addition Area 0.6 R = 0.9999167 0.5 0.4 0.3 Area R = 0.9999812 0.75 0.50 Sample 0.2 0.1 0.25 Automatic dilution 0.0 0.00 0.25 Concentration Diazinon 0.00 0.00 0.25 Concentration Iprobenfos Calibration curve prepared from 1 to 100 pg/µl using automatic dilution function 14

High-Quality Consumables Comprising the GC/MS Flow Path The sensitivity and stability of measurements with GC/MS depend on how much adsorption and other losses can be suppressed in the flow line from sample injection to the detector. The flow lines in the GCMS-QP series and the TQ series consist of high-quality, highly reliable consumable parts, so even trace-quantity concentrations can be detected with high sensitivity and favorable repeatability. Micro-syringe Autosampler syringes feature improved durability, clarity, and accuracy, achieving reliable injection accuracy. GC septum Our lineup now includes low bleed septa, which maintain optimal seal performance even when the injection cycles are increased, and can be used even at high temperatures. This reduces sensitivity variations due to leaks. Glass liner The Restek glass liner recommended for GCMS analysis uses a proprietary inactivation technology to dramatically suppress active sites. After packing into the insert, the wool is subjected to a complete inactivation treatment. This product is controlled throughout from production to final inspection to provide 100 % satisfaction. 17 16.5 16 15.5 Ferrules and gold gasket The high-quality Vespel ferrule is easily attached and designed to resist leaking. The gold gasket is inactive, and adsorption does not occur. 15 14.5 14 13.5 13 7.8 8 8.2 8.4 8.6 8.8 min Capillary columns For the SH-Rxi series, a high-quality fused silica like no other is used as the raw material. Our proprietary surface inactivation technology and optimal process to mask silanol groups result in a low-bleed column with very impressive inactivation performance, even with respect to polar compounds comparable to acidic and basic substances. Blue: Sky liner (with wool) Red: A liner other than Sky liner (with wool) An ultra-low-bleed SH-Rxi column, compared to columns of other manufacturers, can improve sensitivity and accuracy for low-concentration samples. 20.0 17.5 1 ng Tridecane peak 330 C 350 C Brand A Brand B SH-Rxi-5MS 15.0 12.5 10.0 7.5 Brand C 5.0 Brand D Brand E 2.5 Brand F 0.0 pa 0 2 4 6 8 10 12 14 16 18 20 22 24 Time (min) GCMS-TQ8050 Gas Chromatograph Mass Spectrometer 15

GCMS-TQ8050 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2016 First Edition: August 2016, Printed in Japan 3655-08607-30ANS