Advancements in Separation Science

Similar documents
QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

LC Technical Information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

LC and LC/MS Column Selection Flow Chart

Comparison of different aqueous mobile phase HPLC techniques

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Packings for HPLC. Packings for HPLC

penta-hilic UHPLC COLUMNS

It s hot! ZIC -chilic

Part 2. Overview of HPLC Media

Hypersil BDS Columns TG 01-05

Too Polar for Reversed Phase What Do You Do?

Guide to Choosing and Using Polymer Reversed Phase Columns!

High Performance Liquid Chromatography

High Performance Liquid Chromatography

High Performance Liquid Chromatography

8. Methods in Developing Mobile Phase Condition for C18 Column

Leaders in Separation & Purification Technologies

penta-hilic UHPLC COLUMNS

Shodex TM ODP2 HP series columns

Chapter content. Reference

for Acclaim Mixed-Mode HILIC-1 Column

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

How proteins separate on reverse-phase HPLC

Chromatography. Gas Chromatography

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Reversed Phase Solvents

Bringing uhplc Performance to the Separation of Peptides

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Cation Exchange HPLC Columns

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Analysis - HPLC A.136. Primesep 5 µm columns B.136

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

ProPac WCX-10 Columns

Acclaim Mixed-Mode WCX-1

Alltech Alltima HP Introduction

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Small Molecule Selectivity Sampler

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

New Product Update. HPLC Columns

Method Development Kits

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

1.7 m Fortis UHPLC Columns

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Acclaim Mixed-Mode WAX-1 Columns

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Evolution of Mixed-Mode

UPLC Method Development and Validation

C18 Column. Care & Use Sheet

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

InertSustainSwift C8

Mechanisms of retention in HPLC

State-of-the-art C18 HPLC Columns

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Optimisil HPLC & UPLC Column catalogue

Dilution(*) Chromatography

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Principles of Gas- Chromatography (GC)

Advantages of polymerbased. an alternative for ODS

Successfully Scaling and Transferring HPLC and UPLC Methods

Routine MS Detection for USP Chromatographic Methods

for Acclaim Mixed-Mode WCX-1

A Plausible Model Correlates Prebiotic Peptide Synthesis with. Primordial Genetic Code

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

LC Columns with Liquid Separation Cell Technology

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

SGE is excited to launch a new HPLC product line under the ProteCol brand.

1.7µm Fortis UHPLC Columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Figure 1. Structures for Vitamin B2 and Vitamin B1.

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

H P L C C O L U M N S

Gemini-NX Performance paired with Axia Technology

Open Column Chromatography, GC, TLC, and HPLC

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

ACE Ultra Inert Base Deactivated HPLC Columns

Transcription:

Advancements in Separation Science Using Silica Hydride Column Technology to Break Limits in Traditional HPLC Presented by: MicroSolv Technology Corporation Welcome Ladies & Gentlemen to our presentation Advancements in Separation Science. I hope to show you how to increase your HPLC capabilities and to help you understand how HPLC is advancing in at least one area. My name is Bill Ciccone from MicroSolv and I am pleased to be here today. 1

Abstract of today s Presentation Review Current HPLC Barriers & Limits Discuss Root Causes of these Limits Introduce You to Silica Hydride HPLC Columns What they do for you and how to you gain as a chromatographer Real Life Applications Today I hope to show you this advancement in HPLC stationary phase technology and how you can do things you could not do with HPLC before. At least not easily. 2

Common Benefits and Features of HPLC Hydrophobic Compounds retain very well when using Reverse Phase Very reproducible Well known and easy to predict and develop methods Retain bases at high ph, Acids at low ph, or Neutral Compounds Rugged Methodologies is possible Can easily validate and automate HPLC Scale from microbore to preparative separations Works with Normal Phase or Reverse Phase Most common & successful analytical technique for quantifying analytes Let s start with a short review of HPLC and why it is still the number one technique for analysis of small molecules after 30 years. Most of these features of HPLC are well know to all of us but so that we don t miss any important points in this lecture, we have listed these here. And they include. This is by no means a complete list. 3

Silica Structure The backbone for over 250 brands of popular HPLC columns since the beginnig of HPLC Silica particles have always been the backbone of HPLC from its beginning. This simplified structure illustrates the surface chemistry of modern HPLC grade silica. In fact most of the today s presentation shows mostly highly simplified structures. 4

Silica Structure The backbone for over 250 brands of popular HPLC columns Even today. Even you favorite columns Even today, the most popular HPLC columns are made with silica. Even your favorite columns are most likely a C18 or C8 that is a modified silica stationary phase. 5

Why is silica the preferred backbone of HPLC columns? This begs the question: Why is silica the preferred backbone of HPLC columns! 6

Why is silica the preferred backbone of HPLC columns? Excellent Physical Properties! Well suited for high pressure & constant flow of liquids The short and simple answer is that silica has physical and chemical properties are very well suited to the high pressure and constant flow of liquids. 7

Why is silica the preferred backbone of HPLC columns? Excellent Physical Properties! Easily modified by bonded phases Mechanical strength Rigidity Porous, High Surface Area Allows for different selectivity Allows for well packed beds-efficiency Low back pressure-stable beds Allows for small column length Silica not only withstands high pressure in routine use but also its surface can be easily modified to allow retention of hydrophobic compounds. Also, the mechanical strength and rigidity of silica that is made for HPLC allows us to use very high pressure to pack columns and therefore produce highly efficient and reproducible columns. Lastly, silica has enormous surface area which allows columns to have small ID and short length and still have high theoretical plates. 8

Making HPLC Grade Silica To gain some of these features, silica is fired or baked and is hydrated during manufacturing for HPLC to produce surface silanols and form rigidity to product features needed for HPLC. May not be well known What is perhaps not well known is that HPLC grade silica is fired or baked to 600C and then hydroxilated to produce as many surface silanols as possible. This is done so that the silica produces all the features of HPLC and can be chemically modified through the use or organo-silanes. 9

How does this surface structure impact the performance of the columns? Important Property of Silca Impacts Performance positively & negatively. One of the properties of silica that was until now very important and also at the same time a side effect. Is that CLICK 10

How does this surface structure impact the performance of the columns? Simplified Illustration for Presentation Purposes Only Is that the silanols form a very strong association (hydrogen bonding, ionic interaction) with water. Of course, water does not exist in nature as H2O as shown here but as 6H2O and even larger molecular aggregates. 11

HPLC Grade Silica Attracts and holds water and will even adsorb water from your mobile phase until it has reached it s maximum permanent hydration shell Silica is used as a dessicant for non chromatographic purposes Hydration Shell (Adsorbed Water) Since silica attracts and holds water so strongly, a hydration shell or water layer forms on all a silica with silanols. Think in terms of silica loving water and is used as a desiccant and will take water out of your mobile phase until the steady state of this hydration shell is formed. This hydration shell like all nature, is dependant on it environment and therefore is variable in the way it will adsorb or desorb water. This may or may not be obvious and may or may not effect your chromatography. This is the basis for the CLICK.. 12

Some separation mechanisms of silica based HPLC Columns Hydrophobic Interaction Silanophilic Effects Partitioning Adsorption Bonded Phase Required Silanols Hydration Shell/Organic Layer Silica Chemistry Some of the mechanisms in HPLC If you have a bonded phase like C18 or other organo silanes, you can retain hydrophobic compounds but the unmodified silanols have their own place in HPLC and can be desired or not. Partitioning occurs between the hydration shell and the organic layer of your mobile phase. This is responsible for many compounds to retain in HPLC and not the bonded phase like C18. Also, since bonded phases including end capping only covers a very small amount of the surface area, the silica chemistry can play a very big role in the retention of your analytes. So you can see that there are many mechanism, and some that are not listed here, that play a role in HPLC. The more mechanisms working at one time, the more difficult it is to get good peak shapes for complex mixtures and molecules. But HPLC is not the preferred analytical technique for no reason. For many compounds, this type of stationary phase has been extremely successful. 13

Silica is not perfect. Limiting Properties! Unstable at high ph Upper limit is typically ph 9 Surface Acidity Problems for basic compounds Silanols-Surface Chemistry Hydration Shell becomes virtually permanent Trapped Metals Complex with Chelating solutes. Tailing However, as you can see here, silica is not perfect as nothing in life is. Silica has some short comings as we all know and we have listed here some of the main properties of silica that put limits and what you have been able to do with HPLC until now. 14

Common Barriers/Limits of HPLC Summary of what we already know. Hydrophilic Compounds do not retain in RP Loss of RT of very hydrophobic compounds using 100% Water with C18 Need to dry and control moisture in your solvents in NP Chrom Hysteresis when changing chromatographic modes on the same column Long Run Times Long Equilibration times between gradients Low ph instability Short column life when using some MP additives & some analytes Polar & Non Polar Solvent Compatibility Cannot retain bases at low ph or acids at high ph Low MS sensitivity with MP needed for retention in RP or NP On-Column Degradation of analytes due to silanols or surface water layer Bleed of end capping and bonded phases Again, just to summarize what we already know, some of the barriers of silica based HPLC put limits on what we as chromatographers have been able to do with our HPLC. These barriers or limits as we say are not all of the barriers but this represents many of the limits we share with silica based HPLC columns. One of the most common limits for HPLC has been polar or hydrophilic compounds. Using work arounds like high ph or low ph to neutralize compounds above or below their pka to main them more solvophobic has always been a barrier. Other work arounds that have not been successful is to use a completely aqueous mobile phase but ordinary silica columns do not like this and it is difficult to use. If anyone has ever done NP HPLC you know why it is not commonly used anymore. The difficulty in getting reproducible results from run to run is very time consuming and difficult. This is largely due to the silica taking moisture from your MP and chaning the hydration shell on the fly. This can be controlled but it is tedious. Some of the other limits to HPLC have been 15

What are some of the root causes of the Features & Limits of silica based columns? Why has it not advanced or improved on the limits in the last 30 years? What are some of the root causes of these limits? Why have we not improved on this in 35 years? 16

HPLC Grade Silica The hydration shell is somewhat immiscible with organic solvents needed for HPLC and a bi-layer of liquids is created. The hydration shell is changeable and difficult to control between runs with changing mobile phases and or additives. Mobile Phase Short & Simple Answer Silanols are required for Bonding & Traditional HPLC Hydration Shell (Adsorbed Water) The short answer is that to bond ligands such as C18 and others you need silanols present. Also, without silanols, the surface is not amenable to traditional HPLC. The result is that we have learned to live with limits and barriers and to work around and even use the hydration shell and organic layer of the mobile phase to get many good results. What we are here to learn about today is different silica surface manufactured without silanols that allows for bonded phases to be used. This surface is populated with silica hydrides instead of silanols 17

A Recent Advancement in HPLC! Silica Hydride Based HPLC Columns For the purposes of this presentation and in HPLC terms. what is silica hydride? Click. 18

What is Silica Hydride? Silica Hydride is a highly purified silica particle that has been manufactured to have a surface that is populated with silica hydride instead of silanols. All physical features of HPLC silica are the same for silica hydride but the surface chemistry and resulting capabilities are different. Basically, silica hydride is a high purity silica particle that would normally be used in HPLC that retains all the features of HPLC grade silica but has a somewhat different chemical structure on the surface. 19

Ordinary Silica Silica Hydride O O Si OH O O Si OH O O Si OH O O O Si O O O Si O O O Si O O O Si O Si O Si O H H H Same basic structure with different surface chemistries Ordinary is a term we will use to differentiate silica hydride from silica that is populated with silanols. You can see here that the surface and structure of silica between both silica hydride and ordinary silica is essentially the same in that the siloxane bonds that makes for the rigidity and other physical characteristics are the same. What is different is the terminal silanols are gone and replaced with silicon hydrides or Si-H. 20

This difference may seem small and subtle but think in terms of the apple shown here that has a different chemical structure instead. It will be different. So we like to say that structure impacts the performance even when the difference seems small. 21

How does this structural difference impact the performance of the columns? O O Si OH O O Si OH O O Si OH O O O Si O O O Si O O O Si O O O Si O Si O Si O H H H Here is the comparison again, keep in mind the red boxes and how they are different on the surface and how it impacts HPLC. 22

How Does this structural difference impact the performance of the columns? This slide is really the key to why these two different substrates are structurally similar but the performance is very different. As we have previously shown, ordinary silica retains water and does not desorb it unless it is baked at 600C and kept under non aqueous conditions or you use a lot of non aqueous mobile phase for a long long time. The silica hydride particle however is slightly hydrophobic and will desorb any liquid very differently. Don t misunderstand this weak association with water, the surface can be wetted so to speak but it does not build up any hydration shell. I think the operative word here is shell. To sum this slide, the silica hydride particle has all the physical characteristics of ordinary silica but has different adsorption character. 23

We now need to challenge our bias about HPLC column limits to benefit from this advanced and completely different column technology. Enjoy the benefits of silica hydride without limits that exist with hybrid silica and polymeric columns. What about bonding? Don t you need silanols? What this presentation is about is that we are showing an advance in HPLC column chemistry that breaks many of the barriers and limits due to what seems to be a subtle difference from ordinary silica when in fact, the difference is new limits need to be set in HPLC and what it can do for you and your lab. One question that may seem obvious so far is that I mentioned previously that ordinary silica is made for HPLC and that silanols are created for one use and that is to use organo silation to created needed bonded phase. This was true. Professor Joe Pesek at San Jose State University working under a grant from Nasa, developed the silica hydride surface and developed a new bonding process that uses terminal alkenes or alkynes and bonds directly to the silica hydride. 24

Using hydrosilation on silica hydride, direct silicon carbon bonds (with 2 points of attachment) are produced when derivatizing the hydride surface. Without using Organo-Silation Pesek Method of Bonding with Alkynes & Alkenes Some more of the benefits of this new route to making HPLC columns is that you create silicon-carbon bonds between the silica and the bonded phase. Unlike organo silation which results in silicon-oxygen-silicon-carbon bonds. Direct silicon carbon bonds are extremely stable and when using an aklyne, two points of attachment result. Where as the ordinary bonded phases are suseptible to hydrolysis at low ph, these bonds are not. The bottom line here is that extremely stable HPLC stationary phases result. Take a better look at this.. 25

Direct Silicon-Carbon Bonds Silica Structure & Hydride Surface remain after bonding And you can see that the amount of bonded phase is not 100% like ordinary silica and the surface remains a silica hydride with all these properties and no hydration shell. The bonded phase is extremely stable and there is no end capping. This column with a dual point of attachment and a C18 chain bonded to it is more retentive for hydrophobic compounds then virtually all ordinary C18 and is not limited to use of less than 100% aqueous mobile phase. So you can use this column for compounds that you want to analyze in 100% water, not lose retention and if you need PIC reagents for your method, it will not destroy this column chemistry. This series of columns using silica hydride is commercially available as 26

What is Silica Hydride? For the purposes of literature search and to clear up any possible confusion using the internet or industry journals, silica hydride HPLC stationay phases are also commonly known as Cogent TYPE=C Silica which is a trademark of MicroSolv. The term silica hydride was coined by Professor Pesek and used often in the literature interchangeably with TYPE-C Silica Cogent TYPE-C Silica. This is a trademark for HPLC columns based on the silica hydride and the Pesek method of bonding to silica hydride particles. At this point in time, unmodified silica hydride for normal phase HPLC is available along with 4 bonded phases for different uses. We will review each of these phases and how they can be used to break the barriers and limits of traditonal HPLC during the remainder of this presentation. 27

What do we gain from silica hydride HPLC columns? Think in terms of 3 modes of HPLC: Normal Phase Reverse Phase Aqueous Normal Phase You are probably sitting there thinking, okay, this all fine and looks nice but how do I use these columns. What does a chromatographer gain from them and what do we do with this new technology. We are here to present these new columns that are most likely to become a standard of all silica based HPLC columns one day because you can use them for 3 modes of HPLC and break many if not all the barriers of silica based HPLC columns we are discussing today. 28

What do we gain from silica hydride HPLC columns? Normal Phase Easier to do More Reproducible Prep Chromatography Water Free For example, for normal phase HPLC which is very heavily used for preparative methods to avoid water and getting the analytes ready for use in production. Now the barrier of drying solvents and the water poisoning the columns after extended use is eliminated. Remember, it does not remove and therefore change your mobile phase concentration during use. 29

What do we gain from silica hydride HPLC columns? Reverse Phase Limits are Broken 100% Water Mobile Phase ph stability More retentive for hydrophobic compounds Resistant to most additives like PIC reagents No bleed of bonded phases or end capping No on-column degradation of analytes due to acidity Fast equilibration even when using ballistic gradients Excellent for LCMS For reverse phase, there are many limits and barriers that are broken that we all previously lived by. I already mentioned about retention of Hydrophobic compounds with a C18 but you can see that even in our everyday life with C18, using a silica hydride column offers precision and methods that work with shorter run times and longer column life. 30

What do we gain from silica hydride HPLC columns? Aqueous Normal Phase (ANP) Normal Phase with Reverse Phase Solvents Retain polar compounds with precision No hysteresis when changing from RP to ANP Retain bases at low ph Retain acids at higher ph Excellent for LCMS Extremely fast equilibration between runs Very precise from run to run, day to day. Aqueous Normal Phase is a lesser known chromatographic mode that is useful for hydrophilic or polar compounds that normally do not chromatograph well in RP. With ANP you use an inverse mobile phase content from RP since this mode is truly normal phase chromatography but you use RP type of solvents such as Water/Acetonitrile. Since there are no polar groups or the hydration on the surface and therefore equilibrates very fast. Because there are no polar groups on the surface like in an ion exchange or HILIC column, salts and polar compounds do not poison the column. This mode is becoming very popular with metabolomics, drug discovery and analytical methods people that are challenged with polar compounds. 31

Using Silica Hydride stationary phases breaks the limits and barriers of traditional HPLC which results in easier and more productive HPLC labs So, you can see that using a silica hydride stationary phase not only provides for a longer column life and more precise runs but also provides selectivity that until now has been very challenging. 32

How do we use the Silica Hydride Phases? Normal Phase: Standard method development with standard MP to begin with followed by different methods to optimize method objectives by taking advantage of silica hydride column capabilities. So, how does one use the silica hydride based columns? They are very easy but again, you have think in terms of new columns with different barriers or limits. Kind of expands the normal skill set of HPLC. If you want to use normal phase for reasons outside of the scope of this presentation, you would use the unmodified silica hydride commercially called the Silica-C. You would use a standard mobile phase that you would use in normal phase HPLC but you would not have to consider the moisture control steps. What you might find is that you have different selectivity with the silica hydride surface from an ordinary silica surface and you may need to adjust the mobile phase accordingly. One of the costs involved is learning how to optimize your method and think outside the limits. With normal phase on silica hydride columns not only do you not worry about the mositure control but when you change from one mobile phase to another (assuming these are miscible) one column volume equilibration is most likely all you will need. So if you go from Hexane/Ethyl Acetate 90/10 to Hexane/IPA 60-40 the time to equilibrate will be must faster. This really comes in handy when scouting for methods that are optimal not just for results but also for solubility compatibility for greater sample load on the columns. 33

How do we use the Silica Hydride Phases? Reverse Phase or ANP? Many compounds are no longer in the domain of Reverse Phase HPLC Since ANP or aqueous normal phase is so effective for polar compounds, they may no longer be in the domain of reverse phase HPLC as the first method of choice. So you have to evaluate the compounds and the method objectives and decide between these two equally effective, precise and robust methods. If anything breaks the limits or barriers of traditional HPLC it is this opportunity. The good news is that many of the bonded phases, especially the C8 phase can do both. And therefore it is great for complex mixtures such as polar impurities or degradation products of hydrophobic (non polar) analytes. 34

How do we decide between? Rule of Thumb or Quick Start Method to determine best mode for unknown analytes. 1. Gradient 100% A to 40% B 2. Equilibrate for one column volume 3. Gradient from 95% B to 40% A with acid or base added There are a few really good ways to determine which of the modes would be best for your compounds. If the chemical structures are known, you can determine by a simple rule of thumb: Polar Compounds, use ANP Non Polar Compounds use RP But if they are not known and you are looking for a host of possible analytes from your sample, you can use a simple method on the Diamond Hydride, C8, Cholesterol or the C18 column. This methodology utilizes one column, two injections and one set of solvents for you mobile phase. Basically, you inject your compounds with a gradient from 100% water (A) to 40% Acetonitrile (B). Then one column volume to equilibrate the column and the re inject the sample. This time run the Inverse Gradient from 95% Acetonitrile (B) to 40% Water (A). This gradient will retain and you will see your polar compounds. In both solvents, you would add 0.5% formic acid or 0.5% ammonium formate during the second run. Total run time depending on your column length is typically about 30 minutes for each gradient. From this point you then optimize your run with either a gradient or an isocratic method. 35

More about ANP Cyano or Phenyl Columns can do it. Precision and Column Life Times Questionable The mode called ANP or aqueous normal phase is not new. For years, you probably did ANP when you used a cyano or amino columns. The problem is that when you use ordinary silica, the mode is not reproducible When you use silica hydride columns, ANP is extremely precise and accurate. Some mass spec companies are building metabolite data bases using the Diamond Hydride column because according to them, it is the only column on the market that can retain polar compounds precisely enough to plot Retention time v. Accurate Mass and use this plot to identify the identity of the metabolite. 36

More about ANP What is it? Normal Phase Adsorption Ion Interaction (Not Ion Exchange) Use RP Solvents Not HILIC ANP is a type of ion interaction NOT ION EXCHANGE where the retention is due to the adsorptive properites of silica without the water shell. The elution order and the predictability of analytes is truly normal phase. Except you use Reverse Phase solvents instead of non polar solvents. 37

Real Life Applications of using the silica hydride columns and how you can benefit from the new technology in RP, ANP & NP At this point, I would like to show you some applications that have resulted from laboratories using the silica hydride columns. For the sake of time, I will limit these to a well rounded sampling but if you have further interest, I would be happy to show you many others. 38

Real Life Applications of using the silica hydride columns and how you can benefit from the new technology Nucleotide Bases Glyphosate Highly polar compound Melamine and Cyanuric Acid Amino Acids ATP from AMP Succinic Acid Generic Pharmaceuticals Metabolites from human urine Isobaric Compounds for LCMS Organic Acids Cytochrome-C Guanidine Citric Acid from IsoCitric Acid Leucine from Iso-Leucine Biogenic Amines Purine Bases & Nucleosides Some of the areas I will show today are shown here. I will not spend too much time on these but if you would like me to stop and discuss any of these methods, let me know. 39

Application-Reverse Phase Furazolidone: API & Related Compounds Generic Pharmaceutical Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18 4um, 100 Å 4.6mm i.d. x 150mm 2% Acetonitrile, 88% DI Water w/ 10ml/L acetic acid 2.0 ml/min. Isocratic You can use a silica hydride column for the unique selectivity shown compared to other C18 columns as well for the column life. Here you see a method that was developed for impurity testing. Furazolidone is an antibiotic. The detection was 365nm UV and was done at 30C with a 20ul injection. 40

Application-Reverse Phase Guanfacine HCl & Degradants on a C8 mau 600 Guanfacine HCL 500 Degradation Product 1 Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C8, 4um, 100 Å 4.6mm i.d. x 150mm 30% Acetonitrile, 70% DI Water w/conc/phos Acid, SDS 1.5 ml/min. Isocratic 7 minute separation 400 300 Degradation Product 2 200 100 0 0 1 2 3 4 5 6 7 8 9 min Here you can see that using the silica hydride C8, you can use a mobile phase with additives such as SDS that does not effect a silica hydride column. Ordinary C8 columns experience very short shelf life when using SDS. Also, the micelles in this case are very compatible with a silica hydride surface and offer good efficiency. 220 nm UV detection, 20ul injection at 25C. 41

Application-Reverse Phase Peptides: 1. Gly Tyr; 2. Val Tyr Val; 3. Met-enkephalin 4. Leu-enkephalin; 5. Angiotensin II Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18, 4um, 100 Å 4.6mm i.d. x 75mm 25% acetonitrile/75% DI water + 0.1% formic acid 1.0 ml/min. Isocratic 5 minute separation This is a quick method that not only shows the value of the silica hydride C18 column for speed and ease but this shows the precision. This is 8 chromatograms laid on top of each other. Base line separations were not the goal of this method. Just to ID them was sufficient. This is not a fuzzy chromatogram. 42

Application-Reverse Phase Peptides: 1. Gly Tyr; 2. Val Tyr Val; 3. Met-enkephalin 4. Angiotensin II 5. Leu-enkephalin; Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C8, 5um, 300 Å 4.6mm i.d. x 75mm A: DI Water + 0.1% TFA B: Acetonitrile + 0.1% TFA 1.0 ml/min. Fast 20 minute Gradient Gradient Time %B 0.0 9 5.0 21 20.0 27 21.0 9 This slide shows how using a silica hydride based column with wide pores (300A) and modified with C8, you can achieve baseline separation. This gradient was done with 214nm UV. RP gradient takes 21 minutes starting with 9% B for 5 minutes to 21% B. This is not a fuzzy chromatogram. 43

Application-Reverse Phase Cytochrome c: Horse & Bovine on a C8-300 Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C8, 5um, 300 Å 4.6mm i.d. x 75mm A: DI water + 0.1% TFA B: Acn + 0.1% TFA 0.5 ml/min. Fast RP Gradient 5.0min Post Time 1. Cytochrome c from Horse Heart 2. Cytochrome c from Bovine Heart Using the same silica hydride column with C8 with 300A pores results in a great separation of cytochrome c. This was done with a UV detector at 214nm Graident Time %B 0.0 20 16.0 40 18.0 40 18.1 20 44

Application-Reverse Phase Sulfonamide Retention on a C18 Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18, 4um, 100 Å 4.6mm i.d. x 75mm A: DI water + 0.1% formic acid B: Acetonitrile 0.4 ml/min. Fast RP gradient Retention of sulfonamides can be challenging for ordinary C18 columns since they are somewhat limited to use with UV detectors. But using a silica hydride column you can see that good retention is very possible and very compatible with an LCMS over coming the detection limits normally seen for ordinary C18/UV. In this case APCI was used and is superior to ESI ionization method. Gradient Time %B 0 30 0.230 5.0 100 10. 0 30 15.0 30 45

Application-Reverse Phase Dipyridamole:Tablet Formulation From Excipient on a C18 Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18, 4um, 100 Å 4.6mm i.d. x 75mm A: DI water + 0.1% Phos acid B: 80:20 Can:0.1% PhosA 1.5 ml/min. Fast RP Gradient This example shows a very nitrogenous compound as you can see. HPLC with ordinary silica based columns have hard time retaining a compound like this. Here you can use a silica based C18 to retain this compound at low ph with good efficiency and capable of good sensitivity. The other peaks shown are excipients. UV 280nm, 10ul injection at 40C. 46

Application-Reverse Phase Diphenhydramine HCL on a Diamond Hydride Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4um, 100 Å 4.6mm i.d. x 150mm A: DI water + 10mM pyridine B: Acn 10mM pyridine 0.4 ml/min. Fast RP Isocratic @ 25% B Using a silica based diamond hydride column, this antihistaminic drug will stay on the column at 80% B. When you change the MP to one shown here, the compound elutes. This opens a wide range of possibilities for this including on column SPE. This can be very beneficial for isolation of Dph from complex mixtures or for preparative scale use for compounds having similar properties. 47

Application-Reverse Phase 100% Aqueous Mobile Phase on a C18 Column Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18, 4 mm, 100 Å 4.6mm i.d. x 75mm 100% 0.05% v/v H3PO4 1.0 ml/min. Isocratic 1- OXALIC ACID 2- FORMIC ACID 3- ACETIC ACID 4- SODIUM AZIDE 5- URACIL 6- FUMARIC ACID 7- PROPIONIC ACID This is an example of breaking the barrier of using 100% water as a mobile phase on a C18 column. Using a silica hydride column that has been modified with a C18 phase, you can do 1,000 s of injections like this one with no change of RT. If you have compounds that require extremely high water diluents, you can match it to the mobile phase. 215 nm UV detection ws used for this. 48

Application- ANP Melamine & Cyanuric Acid on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 2.1mm i.d. x 150mm A: DI Water 0.1% Acetic Acid B: Acetonitrile + 0.1% Acetic Acid 0.4 ml/min. Fast 15minute Inverse Gradient Melamine and other metabolites of Cryamazine has been investigated by many using many different HPLC or ion chrom methods. You can see here that with a silica hydride based Diamond Hydride column, the separation of two very polar compounds is easy. Great peak shapes for such difficult compounds is another barrier of HPLC that can be broken. 49

Application- ANP Xanthine, Uric Acid & Hypoxanthine on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 2.1mm i.d. x 150mm A: DI Water 0.1% Formic Acid B: Acetonitrile + 0.1% Formic Acid 0.4 ml/min. Fast 12minute Inverse Gradient Samples from human urine, these metabolites are easily identified using the Diamond Hydride silica hydride column. In this case, we added 100ul of Acetonitrile to human urine and centrifuged. 20ul of the supernatant was mixed with 10ul of B component of the MP. Gradient Time % B 0.095 0.295 8.080 9.080 10.0 50 12.0 50 50

Application- ANP Monitoring Patient Levels of Methotrexate on a C18 Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18, 4 mm, 100 Å 2.1mm i.d. x 150mm A: DI Water 0.5% Formic Acid B: Acetonitrile 0.4 ml/min. Fast 12minute Inverse Gradient Methotrexate is a chemotherapy drug that is very difficult to retain on most ordinary C18 columns with good peak shapes. This antimetabolite is used for cancers such as leukemia, osteosarcoma and breast cancer. This was an LCMS method in the positive mode with both specificity & sensitivity. Gradient Time %B 0.0 90 1.0 90 5.0 20 10.0 20 10.01 90 12.0 90 51

Application- ANP Monitoring Patient Levels of Catecholamines on a C18 Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18, 4 mm, 100 Å 2.1mm i.d. x 75mm 90:10 Acetonitrile/DI Water w/ 0.5% FA 0.5 ml/min. Fast isocratic runs 200ng of each sample in 1ml of DI Water This was another clinical example of using silica hydride columns. This C18 was injected with only 200ng dissolved in 1ml of DI Water from actual patient samples in this LCMS method. 52

Application- ANP Choline from Acetylcholine on a UDC Cholesterol Column: Dimensions: Mobile phase: Flow rate: Cogent UDC-Cholesterol, 4 mm, 100 Å 4.6mm i.d. x 75mm 90:10 Acetonitrile/DI Water w/ 0.5% FA 0.5 ml/min. Fast isocratic runs Here is another limit or barrier that is broken using silica hydride columns in HPLC. These challenging Quaternary amines are easy to retain and separate now. This is an example of LCMS of acetylcholine and choline. Normally these compounds are really hard to separate but in 90% Acetonitrile and Water on the cholesterol phase, these compounds separate. 53

Application- ANP Amino Acids, underivatized on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 4.6mm i.d. x 75mm A: DI Water + 0.1% Formic Acid B: Acetonitrile + 0.5% Formic Acid 0.4 ml/min. Fast Inverse Gradient Amino acid analysis is normally done with pre column and post column derivatization kits. With silica hydride columns, it is possible to retain and separate all amino acids without derivatzinging them. This is an exmaple of a very fast method that is consolidated so you can see how these acids retain on the Diamond Hydride column. For baseline separation of specific amino acids, some changes to the method will be required but the method remains simple and easy. It is possible to separate the most difficult amino acids such as leucine from isoleucine. 54

Application- ANP Citric Acid from iso-citric Acid on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 4.6mm i.d. x 75mm A: DI water + 5 mm ammonium acetate; B: 90% acetonitrile/10% DI water/10 mm ammonium acetate C: 90% acetonitrile/10% DI water, D: 50% DI water/50% methanol/0.1% formic acid (wash) 0.4 ml/min. Fast 14 min Inverse Gradient Citric acid and isocitric acid are very important metabolites that have the same empirical formula. They different chemically by the position of a hydroxyl group. A slight modification of solvent gradient A to gradient B resulted in near baseline separation of the two isomers. As can be seen in Fig. each compound has trace amounts of the other isomer in it. This is not a fuzzy chromatogram. 55

Application- ANP Amino Acids on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 4.6mm i.d. x 75mm A: DI water + 5 mm ammonium acetate; B: 90% acetonitrile/10% DI water/10 mm ammonium acetate C: 90% acetonitrile/10% DI water, D: 50% DI water/50% methanol/0.1% formic acid (wash) 0.4 ml/min. Fast 14 min Inverse Gradient San Jose State University, Agilent Technologies and MicroSolv are involved in a joint program to develop a generic method for posiitive and negative ions with either the Diamond Hydride column or the Bidentate C18. With this generic method, a database of metabolites will be generated by plotting RT v. Accurate Mass. Using a quaternary system or two binary pumps and a TOF mass spectrometer, this gradient is used for compounds like these. This method is fast and easy. Another barrier that is broken is using HPLC for metabolite identification. Since the silica hydride columns are easy to equilibrate and therefore precise, it is possible to use RT as a parameter of identification. These amino acids are analyzed with positive mode ESI. 56

Application- ANP Organic Acids on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 4.6mm i.d. x 75mm A: DI water + 5 mm ammonium acetate; B: 90% acetonitrile/10% DI water/10 mm ammonium acetate C: 90% acetonitrile/10% DI water, D: 50% DI water/50% methanol/0.1% formic acid (wash) 0.4 ml/min. Fast 14 min Inverse Gradient Another class of compounds that are normally difficult for HPLC are small organic acids. Using the same generic method, you can analyze these compounds in the negative mode. 57

Application- ANP Carbohydrates on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 4.6mm i.d. x 75mm A: DI water + 5 mm ammonium acetate; B: 90% acetonitrile/10% DI water/10 mm ammonium acetate C: 90% acetonitrile/10% DI water, D: 50% DI water/50% methanol/0.1% formic acid (wash) 0.4 ml/min. Fast 14 min Inverse Gradient To analyze most carbohydrates by HPLC, amino columns or other special columns are used that usually do not have long useful lifetimes. Here you can see that using a silica hydride based Diamond Hydride, you can retain and separate and identify these small carbohydrates. Again, this is the same generic method that was used for the amino acids and the organic acids. These sugars were monitored in the positive mode. 58

Application- ANP Glyphosate, un-derivatized on a Diamond Hydride Column Column: Dimensions: Mobile phase Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 2.1mm i.d. x 150mm A: DI water + 5 mm ammonium acetate; B: 90% ACN/10% DI water/10 mm amm acetate 0.5 ml/min. Fast Inverse Gradient Glyphosate is an extremely difficult compound to retain and normally requires pre column derivatization to get it to retain. Another barrier is broken, retain compounds like this without derivatizing them. Figure one is the first injection, figure 5 is the 5 th injection. Notice the RT is almost identical. Gradient Time %B 0.0 80 1.0 80 1.1 5 5.0 5 5.0 80 59

Application- ANP ATP from AMP on a Diamond Hydride Column Column: Dimensions: Mobile phase Flow rate: Cogent Diamond Hydride, 4 mm, 100 Å 2.1mm i.d. x 100mm A: DI water + 0.1% ammonium acetate; B: 90% ACN/10% DI water/0.1% amm acetate 0.3 ml/min. Fast Inverse Gradient 1 = adenosine-3,5 -cyclic monophosphate; 2 = adenosine 5 -monophosphate 3 = adenosine 5 -triphosphate. Nucleotides such as ATP, AMP and Cyclic AMP are other examples of limits of HPLC. However, using silica hydride stationary phases, you can use retain and separate these compounds. Gradient Time %B 0.095 10.0 70 15.0 70 60

Application- ANP Mepiquat from Chlormequat on a Diamond Hydride Column Column: Cogent Diamond Hydride, 4 mm, 100 Å Dimensions: 2.1mm i.d. x 100mm Mobile phase A: DI water + 20mM ammonium acetate; ph 3 B: Acetonitrile Flow rate: 0.5 ml/min. Fast isocratic run These two chemicals are listed on the World Health Organizations list of hazardous chemicals and are used as plant growth regulators. Monitoring their presence in food is very important. HPLC is unable to analyze these and the current accepted method is to use ion chromatography. Using a silica hydride column, Diamond Hydride, you can retain and separate with good peak shape and efficiency both compounds. Repeatability and reliability are extremely high with silica hydride columns. Now you can use HPLC for these compounds. 61

Application-ANP Organic Acids on a Diamond Hydride Column Column: Dimensions: Mobile phase: Flow rate: Cogent Diamond Hydride HPLC Column, 4 mm, 100 Å 2.1mm i.d. x 150mm A: DI Water 0.1% Am Formate B:90% ACN/10% DI Water/0.1%Am Formate 0.4 ml/min. Fast 8minute Inverse Gradient 1- MALEIC ACID 2- trans ACONITIC ACID 3- cis ACONITIC ACID 4- IMPURITY 5- FUMRAIC ACID 6- CITRIC ACID 7- OXALOACETIC ACID Another example of organic acids by HPLC using a silica hydride column. Notice this is very Mass Spec friendly. 62

Application-Normal Phase Pro Drugs in NP on a C18 Column Column: Dimensions: Mobile phase: Flow rate: Cogent Bidentate C18 HPLC Column, 4 mm, 100 Å 4.6mm i.d. x 75mm 95:5 Hexane/Ethyl Acetate 1.0 ml/min. Isocratic There are many typical methods in Normal phase that you can transfer to a silica hydride column such as the silica-c and take advantage of no need to control sovlent moisture and the column is not poisoned by the water. Here is one example of using a silica hydride column that is modified with a C18 and you can still do Normal Phase with it. This is the same column that you can use for RP (100% Water or typical RP solvents) or ANP (Inverse gradient) and you can switch from non polar solvents to polar solvents and back. Due to the low hysteresis or even lack of it, these columns can be changed back and forth if desired. Another barrier that is broken is that you can use non polar solvents to wash a column that might have been contaminated by a sample. Of course, you can also wash with polar solvents. You just have to pass a miscible solvent such as THF or IPA through the column each time you convert it. In this case, the customer used a C18 with non polar solvents due to the fact that water would degrade or activate these compounds and they wanted to monitor them during manufacturing and still have hydrophobic retention ability. Another barrier in HPLC. You can use solvents that your compounds are most likely to be stable in or maximize the solubility and still do HPLC and match the diluent to the mobile phase. 63

Review of Previous Barriers/Limits of HPLC Summary of what we already knew. Hydrophilic Compounds do retain in RP No Loss of RT of very hydrophobic compounds using 100% Water with C18 No Need to dry and control moisture in your solvents in NP Chrom No Hysteresis when changing chromatographic modes on the same column Shorter Run Times then before Very Short Equilibration times between gradients Low ph Stability Long column life even when using some MP additives & some analytes Polar & Non Polar Solvent Compatibility Retain bases at low ph & acids at high ph Increased MS sensitivity Minimal On-Column Degradation of analytes due to silanols or surface water layer No Bleed of end capping and bonded phases Here is a review of the advancements in HPLC column technology we discussed today. Are there any questions? 64

Change your bias about HPLC Limits The possibilities for new methods are limitless Questions? 65

About MicroSolv MicroSolv started in 1992 Formed to work with technology transfer departments at universities Role MicroSolv plays in product development Tech Transfer Product Development and Marketing R&D Production Design QC Marketing and Sales Distribution of Wide Array of Products Education and Technical Support Product Line Extension 66