Direct Exposure Probe Analysis on the Pegasus HT: An Application Compendium

Similar documents
Identifying Disinfection Byproducts in Treated Water

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Determination of Hydrocarbon Components in Petroleum Naphthas

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Automated and accurate component detection using reference mass spectra

Organochlorine Pesticides by GCxGC-ECD

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

JWH-018 and JWH-022 as Combustion Products of AM2201

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Multi-residue analysis of pesticides by GC-HRMS

ACD/Labs Software Impurity Resolution Management. Presented by Peter Russell

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Analyte Targeting for NPS Identification in Seized Drugs and Toxicology

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Determination of Volatile Substances Proof of Food Adulteration

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

U.S. EPA Method 8270 for multicomponent analyte determination

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Introduction. Chapter 1. Learning Objectives

Agilent 385-ELSD Evaporative Light Scattering Detector

Theory and Practical Consequences.

Lecture 15: Introduction to mass spectrometry-i

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Laser desorption/ionization on the layer of graphene nanoparticles coupled with mass spectrometry for characterization of polymer

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Agilent 385-ELSD Evaporative Light Scattering Detector

Application Note. Edgar Naegele. Abstract

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Supplementary Materials: Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

Headspace Technology for GC and GC/MS: Features, benefits & applications

COMPLEX HEROIN COMPARISON INVESTIGATION

3-Fluoromethcathinone Latest Revision: March 29, 2013

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Introduction to GC/MS

Chemical Analysis Problem

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

MassHunter TOF/QTOF Users Meeting

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Bath Salts and Cannabinoids Analyzed by GC-IR

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Cerno Application Note Extending the Limits of Mass Spectrometry

5Cl-AKB48 and 5Br-AKB48

MetWorks Metabolite Identification Software

MassHunter Software Overview

TIME OF FLIGHT GC/MSTOF

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Routine MS Detection for USP Chromatographic Methods

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

M M e M M H M M H. Ion Sources

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

AccuTOF GCx JMS-T200GC. Scientific / Metrology Instruments High Performance Gas Chromatograph Time-of-Flight Mass Spectrometer

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

Accurate Mass Measurements: Identifying Known Unknowns

Technical Note. Introduction

Die Nadel im Heuhaufen

Benzoylecgonine in Urine by SAMHSA GC/MS

Choosing the metabolomics platform

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

Transcription:

Direct Exposure Probe Analysis on the Pegasus HT: An Application Compendium LECO Corporation; Saint Joseph, Michigan USA Key Words: Direct Exposure Probe (DEP), Pegasus HT, Surfactant, Drugs of Abuse, Organometallic, Food and Flavor 1. Introduction Direct exposure probe (DEP) is a technique for the rapid analysis of a compound which utilizes a filament to vaporize analytes directly in the ionization source as opposed to traditional LC or GC chromatographic techniques. Advantages include the ability to analyze non GC-amenable compounds, such as non-volatile, highly polar, or thermally labile compounds, with minimal sample preparation time and fast sample acquisition times (a few minutes or less). This note is a compendium of various DEP/time-of-flight mass spectrometry applications using direct electron ionization (DEI). 20 40 60 80 100 120 140 160 180 Peak True - sample "triton x-114", peak 2, at 9.9844 s 294 8 82 426 470 514 558 602 646 690 74 15 41 57 107 77 95 121 294 40 60 80 100 120 140 160 180 200 220 240 260 280 00 20 Library Hit - similarity 852, "Ethanol, 2-[2-[4-(1,1,,-tetramethylbutyl)phenoxy]ethoxy]-" n = 2 4 5 6 7 8 15 9 1011 12 45 57 67 77 91 107 119 294 40 60 80 100 120 140 160 180 200 220 240 260 280 00 20 Figure 1. The extracted ion chromatograms (XIC) for the molecular ions of the oligomeric distribution of Triton X-114, a non-ionic surfactant, collected by direct exposure probe/time-of-flight mass spectrometry (DEP/TOFMS). The top mass spectrum is of diethylene glycol octylphenol ether by DEP/TOFMS. The bottom spectrum is a corresponding reference spectrum from IST 14. 22 22 Triton X-114 n = 7.5 (avg) Life Science and Chemical Analysis Solutions

Delivering the Right Results Unique benefits of performing DEP experiments on the Pegasus HT include: 1. Open ion source design provides superior robustness and is extremely low maintenance. 2. Time-of-flight mass spectrometry no mass spectral skewing.. True Signal Deconvolution (TSD ) identify more unique components even without chromatography. 4. The probe installation does not interfere with the ability to run GC or GC GC experiments. The objective of this note was to demonstrate the utility of DEP coupled to LECO's Pegasus HT, time-of-flight mass spectrometer (DEP/TOFMS), for a variety of compound classes. 2. Surfactant: Triton X-114 analysis Triton X-114, polyethylene octyl phenol ether, is a nonionic surfactant with wetting and detergency characteristics that make it suitable for applications like cleaning products, paints and coatings, pulp and paper, textiles, and agrochemicals. A sample of surfactant was introduced to the DEP by touching a wet syringe tip to the DEP filament and allowing to dry prior to analysis. The probe was then inserted into the ion source through the probe vacuum interlock before heating the filament as detailed in Table 1. Full mass range spectra were acquired. Table 1. DEP-Pegasus HT Conditions for Triton X-114 analysis. Scientific Instrument Services (SIS) Direct Exposure Probe PC- Filament Program 0 A to 1.5 A at 0.5 A/min Mass Spectrometer LECO Pegasus HT Ion Source Temperature 200 C Mass Range 5- m/z Acquisition Rate spectra/s Triton X-114 is reported to consist of hepta- and octaethylene glycol octyl phenol ether (OPE-7 and OPE-8), with an average molecular weight of 57. The oligomeric distribution of molecular ions from OPE-2 to OPE-12 are shown between 20 and 140 s in the above chromatogram (Figure 1); the mass difference between peaks are consistent with one polymer repeat unit of ethylene glycol (m/z 44). The number average ( M n ) molecular weight of Triton X-114 can be calculated from the oligomeric distribution of the molecular ions shown in Figure 1. The Mn measured was m/z 82, corresponding to OPE-4. The discrepancy between the measured and reported molecular weight is most likely because ionization and detection efficiencies decrease with increasing mass, biasing the measured 1 calculation low unless a correction factor is applied. The weight average ( M w ) molecular weight can be calculated by + leveraging the [M-C5H 11] fragment ions shown in Figure 2, extending the oligomeric distribution to OPE-17. The M w measured was m/z 56, which correlated well with the reported value (m/z 57). An important note is that this data was collected in mins, highlighting the high-throughput quality of this technique. Peak True [M-C - sample 5 H 11 ] + "Triton X-114", peak 10, at 59.9776 s n = 11 619 [M-C 5 H 11 ] + n = 12 66 n = 7.5 (avg) Triton X-114 [M-C 5 H 11 ] + n = 1 [M-C 707 5 H 11 ] + [M-C 646 n = 14 5 H 11 ] + [M-C 5 H 11 ] + n = 15 690 751 n = 16 [M-C 5 H 11 ] + 6 74 795 89 n = 17 620 640 660 680 700 720 740 760 780 800 820 840 860 880 900 + Figure 2. The mass spectrum of Triton X-114 by DEP/TOFMS showing the oligomeric distribution of the [ M-C5H 11] fragment ions for n = 11 to 17.

. Organometallic: 1,1'-Bis(diphenylphosphino)ferrocene analysis The bidentate phosphine ligand 1,1'-Bis(diphenylphosphino)ferrocene (DPPF) is an iron-containing organophosphorous compound, marketed as a "greener alternative" catalyst for a number of cross-coupling reactions. A solution of DPPF was prepared for DEP/TOFMS analysis by dissolving 1 mg of DPPF (Sigma-Aldrich) in 1 ml of chloroform. A small droplet was placed on the DEP filament and allowed to dry prior to analysis. Instrumental details are described in Table 2. Table 2. DEP-Pegasus HT Conditions for 1,1'-Bis(diphenylphosphino)ferrocene. Scientific Instrument Services (SIS) Direct Exposure Probe PC- Filament Program 0 A to 1.5 A at 1.2 A/min Mass Spectrometer LECO Pegasus HT Ion Source Temperature 200 C Mass Range 5- m/z Acquisition Rate 4 spectra/s The DEI mass spectrum of DPPF, shown in Figure, was collected and searched against the IST mass spectral database within a few minutes. The similarity score of 872 out of indicates a very good library match, and validates the applicability of this technique for the rapid analysis of organometallic compounds. Peak True - sample "dppf", peak 2, at 21.662 s 554 56 121 171 292 477 226 69 246 99 445 50 100 150 200 250 00 50 400 450 550 Library Hit - similarity 872, "Ferrocene-1,1'-bis-(diphenylphosphine)" 292 171 226 69 56 277 78 1 99 445 50 100 150 200 250 00 50 400 450 550 Figure. The top mass spectrum of 1,1'-Bis(diphenylphosphino)ferrocene, DPPF, was collected by DEP/TOFMS. The bottom spectrum is a reference spectrum from IST 14. 4. Forensics: Synthetic Drugs of Abuse Synthetic cathinones and synthetic cannabinoids are two of the most common classes of synthetic "designer" drugs in the US, often labeled "not for human consumption" to avoid regulation by governing agencies such as the US Food and Drug Administration (FDA). The abuse of these drugs can cause severe health effects, and have resulted in 2 an increasing number of related calls to poison control centers since 2009. The sheer number of these compounds makes their rapid identification critical for treatment as new drugs of abuse rapidly enter the market. A synthetic cathinone, -Fluoromethcathinone (ZX-1), and a synthetic cannabinoid, 1-(5-fluoropentyl)--(1-naphthoyl)indole (AM-2201), were analyzed by DEP/TOFMS; this technique is extremely useful for confirming the identity of a drug in a timely manner. 477 554 Life Science and Chemical Analysis Solutions

Delivering the Right Results About 1 mg of ZX-1 and AM-2201 were each diluted in 1 ml of methanol. Approximately 1 µl of the solution was introduced onto the DEP filament using a syringe. The solvent was allowed to evaporate prior to analysis. Samples were analyzed according to the conditions in Table. Table. Pegasus HT Conditions. Scientific Instrument Services (SIS) Direct Exposure Probe PC- Filament Program 0 A to 1.5A at 1.0 A/min Mass Spectrometer LECO Pegasus HT Ion Source Temperature 200 C Mass Range 5- m/z Acquisition Rate spectra/s ZX-1 TIC (scaled) -Fluoro-iso-methcathinone M.F. = C 10 H 12 FO 1 2 -Fluoromethcathinone M.F. = C 10 H 12 FO 5 10 15 20 Peak True - sample "ZX-1", peak 2 Peak True - sample "ZX-1", 25 peak 0 5 40 95 18 18 58 1 2 800 600 42 95 42 12 75 40 60 80 100 120 140 160 180 200 Library Hit - similarity 817, "-Fluoromethcathinone" 400 58 200 8 97 109 122 40 60 80 100 120 140 160 180 200 95 42 75 50 12 40 60 80 100 120 140 160 180 200 Figure 4. DEP-TOFMS analysis of ZX-1, a synthetic drug of abuse. The total ion chromatogram (TIC) was intensity scaled graphically to be similar to the intensity of the extracted ion chromatograms (XIC) of two ions distinguishable between -Fluoromethcathinone (-FMC) and -Fluoroisomethcathinone (-FisoMC), identified with True Signal Deconvolution. The active component in ZX-1 is reportedly -Fluoromethcathinone (-FMC), a stimulant drug. The presence of -FMC was confirmed within a few minutes by library searching the deconvoluted DEI mass spectra against the IST, Wiley, and Cayman mass spectral databases; however, an additional component was also detected by deconvolution that was not in the database (Figure 4). A literature search indicated that -FMC is enantiomerically impure, often containing -Fluoro-iso-methcathinone (-FisoMC). Peak 1 in Figure 4 matches the mass spectra for -FisoMC available in the literature. True Signal Deconvolution was able to find the two components in ZX-1, all in less than a minute of analysis time.

The synthetic cannabinoid, AM-2201, was analyzed similarly to ZX-1 as detailed in Table. In this case, one clean peak was detected and the mass spectrum was library searched for authentication. The very good similarity score of 859 out of suggested that the synthetic drug was in fact AM-2201. otice that the total run time was minutes. 25.658 O F AM-2201 20 40 60 80 100 120 140 160 180 127 144 22 284 42 59 Peak True - sample "AM-2201", peak 1, at 25.658 s 41 144 22 127 155 116 254 270 69 89 102 184 215 284 59 42 40 60 80 100 120 140 160 180 200 220 240 260 280 00 20 40 60 Library Hit - similarity 859, "AM2201" 41 127 22 284 144 270 116 241 77 102 167 6 89 189 21 296 40 60 80 100 120 140 160 180 200 220 240 260 280 00 20 40 60 Figure 5. The extracted ion chromatograms of the five most abundant ions in the deconvoluted DEI mass spectrum of AM-2201, with its corresponding mass spectral library hit; the mass spectral similarity was 859 out of. 5. Food and flavor The analysis of fructose and caffeine was conducted according to the experimental details in Table. Approximately 1 µl of a 1 mg/ml solution of each analyte was injected onto the DEP filament using a syringe; the solvent was allowed to evaporate before analysis. The fructose DEI mass spectrum had a very good library similarity score of 864 out of, and the caffeine DEI mass spectrum had an excellent library score of 950 out of. Sugars are difficult to analyze by GC without derivatization, and this example for fructose demonstrates the utility of DEP for the direct analysis of sugars, saving sample preparation and analysis time. HO TIC 20 40 60 80 100 120 140 160 180 Peak True - sample "fructose", peak 1, at 2.992 s 4 40 50 60 70 80 90 100 110 120 10 140 150 160 Library Hit - similarity 864, "Fructose" 4 2.992 60 7 55 49 77 86 90 97 10 119 149 61 7 57 10 90 49 77 11 97 121 11 85 149 40 50 60 70 80 90 100 110 120 10 140 150 160 O Figure 6. (Left ) Total ion chromatogram (TIC) of fructose collected by DEP/TOFMS with its corresponding DEI mass spectrum. The bottom spectrum is the matching reference spectrum from IST 14. (Right) The DEI mass spectrum of caffeine with its matching library spectrum. 42 55 67 82 42 59 O TIC 80 100 120 140 160 180 Peak True - sample "caffeine", peak 1, at 111.191 s 20 40 60 80 100 120 140 160 180 200 Library Hit - similarity 950, "Caffeine" 111.191 109 94 122 17 150 165 109 55 67 82 42 28 94 122 17 150 O 20 40 60 80 100 120 140 160 180 200 165 194 194 Life Science and Chemical Analysis Solutions

Delivering the Right Results 6. Conclusion Direct exposure probe coupled to time-of-flight mass spectrometry (DEP/TOFMS) is a very powerful tool for the rapid and reliable analysis of compounds as demonstrated by these examples. An unsurpassed benefit of LECO's system is the ChromaTOF -GC brand software, which includes True Signal Deconvolution that enables the identification of additional components even without chromatographic separation. Furthermore, the open source design of the Pegasus HT provides unmatched robustness and is extremely low maintenance compared to any other ion source on the market. These features enable users to extract more information out of their DEP experiments, and in a very timely fashion. 7. References 1 Barner-Kowollik, C.; Gruendling, T.; Falkenhagen, J.; Weidner, S. Mass Spectrometry in Polymer Chemistry. 2012. Wiley & Sons, Weinheim, Germany; pp 450. 2 ational Drug Threat Assessment. 2011. U.S. Department of Justice ational Drug Intelligence Center. Product o. 2011-Q017-001. http://www.justice.gov/archive/ndic/pubs44/44849/44849p.pdf Davies, S., Archer, R. and Ramsey, J. (2009) Analytical profiles of methcathinone and related compounds, London Toxicology Group, London. http://www.ltg.uk.net/admin/files/methcath.pdf LECO, Pegasus, Chroma TOF, True Signal Deconvolution, and TSD are registered trademarks of LECO Corporation. Triton is a trademark of Sigma-Aldrich. LECO Corporation 000 Lakeview Avenue St. Joseph, MI 49085 Phone: 800-292-6141 Fax: 269-982-8977 info@leco.com www.leco.com ISO-9001:2008 HQ-Q-994 LECO is a registered trademark of LECO Corporation. Form o. 20-821-486 /15-REV0 2015 LECO Corporation