Neutronics Experiments for ITER at JAERI/FNS

Similar documents
Integral Benchmark Experiments of the Japanese Evaluated Nuclear Data Library (JENDL)-3.3 for the Fusion Reactor Design

Benchmark Test of JENDL High Energy File with MCNP

Estimation of Radioactivity and Residual Gamma-ray Dose around a Collimator at 3-GeV Proton Synchrotron Ring of J-PARC Facility

FUSION NEUTRONICS EXPERIMENTS AT FNG: ACHIEVEMENTS IN THE PAST 10 YEARS AND FUTURE PERSPECTIVES

(Tandem Collimators for the Tangential GammaRay Spectrometer - KM6T-TC)

Published online: 27 Aug 2014.

SINBAD Benchmark Database and FNS/JAEA Liquid Oxygen TOF Experiment Analysis. I. Kodeli Jožef Stefan Institute Ljubljana, Slovenia

Iron Neutron Data Benchmarking for 14 MeV Source

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

Some Comments to JSSTDL-300

Neutronics experiments for validation of activation and neutron transport data for fusion application at the DT neutron generator of TU Dresden

Tandem Collimators System

Transmutation of Minor Actinides in a Spherical

Present status of fusion neutronics activity and comments to neutron diagnostics for TBM

Issues for Neutron Calculations for ITER Fusion Reactor

This paper should be understood as an extended version of a talk given at the

PoS(FNDA2006)093. Fusion neutronics experiments

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Neutron and Gamma-ray Emission Double Dierential Cross Sections. *5 Energy Conversion Engineering, Kyushu University, Kasuga-koen, Kasuga-shi 816.

Fusion/transmutation reactor studies based on the spherical torus concept

Progress in Nuclear Science and Technology, Volume 6,

Analyses of shielding benchmark experiments using FENDL-3 cross-section data starter library for ITER and IFMIF applications

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

Fusion Neutronics, Nuclear Data, Design & Analyses - Overview of Recent FZK Activities -

anti-compton BGO detector

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

TAGS and FP Decay Heat Calculations( ) -Impact on the LOCA Condition Decay Heat-

Measurements of Neutron Capture Cross Sections for 237, 238 Np

Experimental Determination of Cross Sections for (n,x) Nuclear Reactions

Error Estimation for ADS Nuclear Properties by using Nuclear Data Covariances

Journal of Radiation Protection and Research

Study on Radiation Shielding Performance of Reinforced Concrete Wall (2): Shielding Analysis

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination

Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

P39 A Database for Transmutation of Nuclear Materials on Internet

The possibility to use energy plus transmutation set-up for neutron production and transport benchmark studies

Shutdown dose calculations for the IFMIF test facility and the high flux test module

Neutronics experiments for validation of activation and neutron transport data for fusion application at the DT neutron generator of TU Dresden

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

RESEARCH IN THE FIELD OF NEUTRONICS AND NUCLEAR DATA FOR FUSION

Neutronics R&D Needs and Testing In Fusion Test Facility

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

The Possibility to Use Energy plus Transmutation Setup for Neutron Production and Transport Benchmark Studies

arxiv:physics/ v1 3 Aug 2006

Radioactivity. (b) Fig shows two samples of the same radioactive substance. The substance emits β-particles. Fig. 12.1

Shielded Scintillator for Neutron Characterization

Benchmark Tests of Gamma-Ray Production Data in JENDL-3 for Some Important Nuclides

Status of the AGS Experiment for Mercury Spallation

Measurement of 40 MeV Deuteron Induced Reaction on Fe and Ta for Neutron Emission Spectrum and Activation Cross Section

VERIFICATION OF MONTE CARLO CALCULATIONS OF THE NEUTRON FLUX IN THE CAROUSEL CHANNELS OF THE TRIGA MARK II REACTOR, LJUBLJANA

1 FT/P5-15. Assessment of the Shielding Efficiency of the HCLL Blanket for a DEMOtype Fusion Reactor

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

High Energy Neutron Scattering Benchmark of Monte Carlo Computations

Precision neutron flux measurement with a neutron beam monitor

Shielding for Fusion Reactors

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

An introduction to Neutron Resonance Densitometry (Short Summary)

arxiv: v1 [physics.ins-det] 9 Apr 2018

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

Review of nuclear data of major actinides and 56 Fe in JENDL-4.0

A study of 239 Pu production rate in a water cooled natural uranium blanket mock-up of a. fusion fission hybrid reactor

Activation Calculation for a Fusion-driven Sub-critical Experimental Breeder, FDEB

Optimization studies of photo-neutron production in high-z metallic targets using high energy electron beam for ADS and transmutation

CONCEPTUAL STUDY OF NEUTRON IRRADIATOR-DRIVEN BY ELECTRON ACCELERATOR

Measurement of induced radioactivity in air and water for medical accelerators

Neutronic Design on a Small Accelerator based 7 Li (p, n) Neutron Source for Neutron Scattering Experiments

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

New Neutron-Induced Cross-Section Measurements for Weak s-process Studies

Measurement of activation of helium gas by 238 U beam irradiation at about 11 A MeV

Response of thin foil Faraday Cup lost alpha particle detector in intense neutron and gamma ray radiation fields

MONTE CALRLO MODELLING OF VOID COEFFICIENT OF REACTIVITY EXPERIMENT

Experimental Facility to Study MHD effects at Very High Hartmann and Interaction parameters related to Indian Test Blanket Module for ITER

Hands on LUNA: Detector Simulations with Geant4

Experimental Studies on the Self-Shielding Effect in Fissile Fuel Breeding Measurement in Thorium Oxide Pellets Irradiated with 14 MeV Neutrons

I. Kodeli 1. INTRODUCTION

Benchmark Experiments of Accelerator Driven Systems (ADS) in Kyoto University Critical Assembly (KUCA)

PHYSICS A2 UNIT 2 SECTION 1: RADIOACTIVITY & NUCLEAR ENERGY

Arjan Plompen. Measurements of sodium inelastic scattering and deuterium elastic scattering

Important Remarks on Latest Multigroup Libraries

New irradiation zones at the CERN-PS

Neutronic Activation Analysis for ITER Fusion Reactor

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Fission Fragment characterization with FALSTAFF at NFS

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

MUSE-4 BENCHMARK CALCULATIONS USING MCNP-4C AND DIFFERENT NUCLEAR DATA LIBRARIES

Intercomparison between Monte Carlo codes and experiments for induced activities due to high energy electrons

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Using Neutron Generator with APT/NNA for Detection of Explosives

MCNP CALCULATION OF NEUTRON SHIELDING FOR RBMK-1500 SPENT NUCLEAR FUEL CONTAINERS SAFETY ASSESMENT

Study of High-energy Ion Tail Formation with Second Harmonic ICRF Heating and NBI in LHD

Transcription:

Neutronics Experiments for ITER at JAERI/FNS C. Konno 1), F. Maekawa 1), Y. Kasugai 1), Y. Uno 1), J. Kaneko 1), T. Nishitani 1), M. Wada 2), Y. Ikeda 1), H. Takeuchi 1) 1) Japan Atomic Energy Research Institute (JAERI), Ibaraki-ken, Japan 2) Startcom Co., Ltd., Tokyo, Japan e-mail contact of main author : konno@fnshp.tokai.jaeri.go.jp Abstract. A series of fusion neutronics experiments has been performed at the Fusion Neutronics Source (FNS) facility at JAERI as ITER/EDA R&D Tasks in order to deal with various nuclear problems originating from 14- MeV neutrons in ITER. Recently three experiments were carried out; 1) straight duct streaming experiments, 2) decay heat experiments and 3) development of a fusion power monitor utilizing activation of water. The straight duct streaming experiments suggest that the calculation accuracy for straight duct streaming analyses in ITER nuclear designs is ± 40 %. The decay heat experiments show that the accuracy of the decay heat calculation is within 10 % for copper and type 316 stainless steel, while it is ~ 30 % for tungsten. It is demonstrated that a fusion power monitor utilizing activation of water is applicable to ITER. 1. Introduction A series of fusion neutronics experiments has been performed at the Fusion Neutronics Source (FNS) facility at JAERI as ITER/EDA R&D Tasks in order to deal with various nuclear problems originating from 14-MeV neutrons in ITER. Bulk shielding, gap streaming, nuclear heating and induced radioactivity experiments were presented at the previous IAEA Conference [1]. After these experiments, straight duct streaming experiments were carried out to demonstrate the design accuracy for more complicated shields in ITER. Also new decay heat experiments were started to study safety against loss of coolant accidents. Moreover a reliable fusion power monitor was developed using activation of water. This paper overviews these experimental activities newly conducted for ITER/EDA at JAERI/FNS. 2. Straight Duct Streaming Experiments [2] The aim of the experiments is at investigation of influences of radiation streaming through straight ducts, such as diagnostic ports and neutral beam injector (NBI) ports, and validation of the accuracy of design calculations. To simulate various duct dimensions, small duct and large duct streaming experiments which simulated the diagnostic ports and NBI ports, respectively, were 238 Cavity Cavity 1490 Iron slab block-1 block-2 1050 A' 220 220 1200 800 Iron Iron Iron Iron 1050 1645 357 Height of Neutron Source Direct duct Offset duct 400 150 150 400 207 A (a) Front view (Unit : mm) Cavity 200 : Measuring points in FIG. 2 (b) Side view [Vertical cross section of A-A'] FIG. 1. The small straight duct streaming experimental assembly.

performed. Integrated neutron flux [1/cm 2 /source neutron] 10-6 10-8 10-10 10-12 10-14 10-16 Large Duct Expt. Bulk without cavity (DORT Calc.) Small duct Small duct Large duct -400-200 0 200 400 Distance from height of D-T neutron source [mm] For the small duct streaming experiment, as shown in FIG. 1, two ducts of mm in diameter were embedded in an iron slab of 1200 mm in thickness. One of the ducts (direct duct) viewed a point D-T neutron source located on the duct axis 1700 mm from the iron slab, and the other (offset duct) was located at a position shifted lower by mm from the direct duct. One straight duct of 400 mm x 400 mm cross section was made at the same height as the D-T neutron source in the iron slab for the large duct streaming experiment. A cavity region was located behind the iron slab for simulation of a measurement or an ion source room at the end of a port. Neutron spectra, various reaction-rates, gamma-ray spectra and gamma-ray heating rates of iron were measured along the duct and inside the cavity. Distributions of measured neutron flux above 10 MeV and gamma-ray heating rate of iron along the vertical line on the rear surface of the iron slab are presented in FIG. 2. Rough DORT calculations [4] with FENDL/MG-1.1 [5] for the bulk experimental assembly without ducts and cavity are also plotted for comparison in this figure. This figure shows that the ducts and cavity increase the neutron flux above 10 MeV by 10 7 and 10 6 times at the ends of the direct small and large ducts, and the offset small duct, respectively. It is noted that the neutron flux above 10 MeV increases by 10 3 times even at the shaded positions located 400 mm from the direct small duct. However, the increase of gammaray heating rate of iron due to the ducts and cavity is less than a few hundred times. Experimental analyses were carried out by the Monte Carlo transport code MCNP4A with several transport cross section data; FENDL/E-1.1 [6], FENDL/E-2.0 [7] and JENDL Fusion File [8]. As a result, calculations predicted mostly within ± 40 % the complicated neutron and gammaray flux distributions in the ducts and cavity observed in the experiments for both small and large duct assemblies. Accordingly, it was demonstrated that the calculation accuracy for straight duct streaming analyses in ITER nuclear designs with MCNP4A and these data was ± 40 %, which is sufficiently accurate for radiation shielding calculations. 3. Decay Heat Experiments Small Duct Expt. Although accurate estimation of decay heat values is essential for safety analyses of fusion reactors against loss of coolant accidents, no experimental work has been devoted to validating the estimation. To ameliorate this situation, a decay heat measurement experiment was per- Gamma heating rate [Gy/source neutron] 10-17 10-18 10-19 10-20 Large Duct Expt. Bulk without cavity (DORT Calc.) Small Duct Expt. Small duct Small duct Large duct -400-200 0 200 400 Distance from height of D-T neutron source [mm] (a) neutron flux above 10 MeV (b) gamma-ray heating rate of iron FIG. 2. Distributions of measured (a) neutron flux above 10 MeV and (b) gamma-ray heating rate of iron along the vertical line on the rear surface of the iron slab in the streaming experiments.

formed as a task of the ITER/EDA [9]. A new detector shown in FIG. 3, the Whole Energy Absorption Spectrometer (WEAS), was developed [10] for accurate and efficient measurements of decay heat. In the first phase experiments [11], decay heat produced in the thirty-two sample materials which were irradiated by 14- MeV neutrons was measured with WEAS for a long range of cooling time periods from 1 min to 400 days. Accordingly, the first experimental data for decay heat were obtained in the field of fusion neutronics. The validity of decay heat calculation codes such as ACT4 [12], activation cross section libraries of FENDL/A-2.0 [13] and JENDL Activation File [14], and decay data was investigated through analyses of the experiment. As a result, several points that should be modified were found in the codes and data. After solving the problems, it was demonstrated that decay heat values calculated for most of the samples were in good agreement, typically within 20 %, with the experimental data. For the two most important materials in ITER, copper and type 316 stainless steel (FIG. 4), it was found that the decay heat could be accurately predicted within 10 % with codes and nuclear data which were used in safety analyses. The data were further utilized for validating decay heat calculation codes and data used in other institutes through an international benchmark study [15]. The second phase experiments were devoted to decay heat produced in ITER baffle plates made of tungsten. In ITER-like neutron environments, the main decay heat source in the baffle plates is 187 W produced by the 186 W(n,γ) 187 W reaction with low-energy neutrons. Hence, a decay heat experiment featuring low-energy neutron induced 187 W production [16] was performed. Tungsten foil samples were irradiated in an ITER-like neutron field, and the decay heat produced in the samples was measured with WEAS with experimental errors of ~ 5 %. The analyses of the experiments were performed with the MCNP transport calculation code. It was found that the use of an effective activation cross section calculated by MCNP was essential for properly treating the self-shielding effect of cross sections having sharp resonance peaks. When a result calculated with the FENDL cross section library was compared with the experimental data, the calculated decay heat was 21 % smaller than the experimental data. In conclusion, the safety margin Photomultiplier Tube (PMT) Dark Box 120φ x mm BGO Scintillator X-Ray Shield Copper (5mm) +Acryl (5mm) HV Signal PMT HV Signal Lead Shield Detector Support Irradiated Sample (~ 25 x 25 x 0.01 mm) FIG. 3. Schematic diagram of the Whole Energy Absorption Spectrometer (WEAS). 10 0 SS-316 5 Min. Irradiation 10-1 SS-316 7 Hours Irradiation Decay Heat [µw/g] 10-1 Expt. ACT4 & JENDL-Act96 ACT4 & FENDL/A-2.0 10-2 1 1 0 Cooling Time [min] Decay Heat [µw/g] 10-2 10-3 10-4 Expt. ACT4 & JENDL-Act96 ACT4 & FENDL/A-2.0 1 1 0 Cooling Time [days] FIG. 4. Measured and calculated decay heat values for SS-316 samples irradiated for 5 minutes and 7 hours.

of 15 % used in the safety designs has to be increased to 25 % ~ 30 % for the ITER baffle plates. 4. Development of Fusion Power Monitor based on Activation of Water Flow Neutron activation methods using solid metal samples are used for accurate measurements of the neutron yield in many fusion devices without temporal resolution. We have developed a neutron activation detector with water flow based on the 16 O(n,p) 16 N reaction for accurate fusion power monitoring with reasonable time resolution for fusion experimental reactors such as ITER. When water is irradiated by 14 MeV neutrons, radioactive 16 N nuclei are produced by the 16 O(n, p) 16 N reaction. A 16 N nucleus emits 6.13 (68.8%) or 7.12 (4.7%) MeV γ-rays accompanied by disintegration with half-life of 7.13 seconds. Since the 16 O(n, p) 16 N reaction has a threshold energy at 10.4 MeV, 16 N nuclei are practically produced only by 14 MeV neutrons generated by D-T reactions in a fusion reactor. The ITER requirements for this fusion power monitor are a temporal resolution of ms and 10 % uncertainty. In the previous work [17], the temporal resolution was confirmed to be less than 10 s. We carried out experiments to investigate the temporal resolution more precisely at FNS. The experimental setup is shown in FIG.5. Part of a water pipe loop was placed in front of a neutron generation target with the center axis of the water pipe 1.5 cm from the target. The distance between the target and the γ-ray detector was chosen to be 10 m, which is the shortest practical distance from ITER-FEAT. As the γ-ray detector, a large BGO (Bi 4 Ge 3 O 12 ) scintillation detector was adopted, because BGO has very high effective atomic numbers suitable for counting high-energy γ-rays of 6.1 and 7.1 MeV from 16 N. The FNS accelerator was operated in a pulse mode for the time response measurement, with a pulse width of 10 ms. The flow velocity range was 2-11 m/s, which corresponds to a Reynold s number range of 2 x 10 4 to 1.2 x 10 5. We obtained a temporal resolution of 50 ms at a flow velocity of 10.7 m/s. It was found that the measured temporal resolution was described well by a turbulent dispersion model in this range of flow velocities [18]. In a real fusion experimental reactor, the irradiation end of the water loop will be installed in a blanket module. We investigated the effect of the surrounding material of the irradiation end to evaluate the accuracy of this fusion power monitor. A shielding blanket mock-up assembly consisting of multi-layers of type 316 stainless steel (SS316) and water with a source reflector (see FIG. 6) was utilized for simulating the neutron field at the shielding blanket region of ITER. The irradiation end was embedded in the first SS316 layer. The FNS accelerator was operated in a DC mode. The true neutron yield was monitored with an associated alpha detector mounted at the target assembly. Otherwise the setup was the same as that of the temporal resolution measurement. The neutron spectrum at the irradiation end and the detection efficiency of the γ-ray detector were calculated by the MCNP4B [19] code with the FENDL/E- 2.0 library. The cross section data of the 16 O(n,p) 16 N reaction was taken from the FENDL/A-2.0 file. The neutron yield from the 16 N activity was about 10% smaller than that from the associated alpha detector. The statistical error of the gamma-ray measurements was less than 1%. The uncertainty of the neutron yield from the associated alpha detector was 3%. The evaluated values of the 16 O(n,p) 16 N cross-section have 5% difference among FNS facility (JAERI) D-T Neutrons Target Shielding wall Measurement room Lead shield Irradiated water BGO Scintillator Flow meter Target room Water loop 2 m Water Pump Water reservoir FIG. 5. Experimental set-up of the neutron monitor using activation of water flow for the temporal resolution.

nuclear data libraries. We need further investigations on the cross-section to improve the smaller neutron yield from the 16 N activity. Finally, we can conclude that the fusion power monitor using water activation can measure the D-T neutron flux within 10% uncertainty with a temporal resolution smaller than ms, and that the water-flow activation detector is applicable to ITER as a fusion power monitor. References Target Room D-T Neutron Source SS316 (Unit: mm) Shielding Wall Water Loop Irradiation end 711 Water φ1200 FIG. 6. Shielding blanket mock-up assembly to simulate the ITER neutron field. [1] IKEDA, Y., et al., Proc. 17 th IAEA Fusion Energy Conference, ITERP2/03. [2] KONNO, C., et al., Overview of straight duct streaming experiments for ITER, to be published to Fusion Eng. Des. [3] RHODES, W.A. and F. R. MYNATT, F.R., The DORT two-dimensional discrete ordinates transport code, Nucl. Sci. Eng. 99 (1988) 88. [4] PASCHENKO, A.B., et al., IAEA-NDS-169, Rev. 3, IAEA, Vienna (1996). [5] BRIESMEISTER, J.F.(Ed), MCNP - A general Monte Carlo n-particle transport code Version 4A, LA-12625-M, Los Alamos National Laboratory (1993). [6] GANESAN, S., et al., IAEA-NDS-128, Rev. 3, IAEA, Vienna (1996). [7] PASCHENKO, A.B., et al., IAEA-NDS-175, Rev. 3, IAEA,Vienna (1998). [8] CHIBA, S., et al., Evaluation of JENDL Fusion File, JAERI-M 92-027, Japan Atomic Energy Research Institute (1992), 35-44. [9] MAEKAWA, F., WADA, M. and IKEDA, Y., Decay heat experiment and validation of calculation code systems for fusion reactor, JAERI-Research 99-055, Japan Atomic Energy Research Institute (1999). [10] MAEKAWA, F., WADA, M. and IKEDA, Y., Development of whole absorption spectrometer for decay heat measurement, Nucl. Instrum. Meth. A 450 (2000) 467. [11] SEKI, Y., et al., THIDA-2 : An advanced code system for calculation of transmutation, activation, decay heat and dose rate, JAERI 1301, Japan Atomic Energy Research Institute (1986). [12] PASCHENKO, A.B., IAEA-NDS-173, IAEA, Vienna (1998). [13] Nakajima, Y., Status of the JENDL activation file, JAERI-Conf 96-008, Japan Atomic Energy Research Institute (1986) 50-55. [14] MAEKAWA, F. and IKEDA, Y., Fusion Eng. Des. 47 (2000) 377. [15] TAYLOR, N.P., et al., Experimental validation of calculations of decay heat induced by 14 MeV neutron activation of ITER materials, Fusion Eng. Des. 45 (1999) 75. [16] MAEKAWA, F., et al., Decay heat experiment featuring low-energy neutron induced tungsten-187 production in ITER baffle plates and its analysis, to be published to Fusion Eng. Des. [17] IKEDA, Y., et al., An investigation of the activation of water by D-T fusion neutrons and some implications for fusion reactor technology, Fusion Eng. Des. 37 (1997) 107. [18] KANEKO, J., et al., Technical feasibility study on a fusion power monitor base on activation of water flow, to be published in Rev. Sci. Instrum. [19] BRIESMEISTER, J.F.(Ed), MCNP - A general Monte Carlo n-particle transport code version 4B, LA-12625-M, Los Alamos National Laboratory (1997).