arxiv: v1 [physics.ins-det] 23 Oct 2007

Similar documents
SuperNEMO Double Beta Decay Experiment. A.S. Barabash, ITEP, Moscow (on behalf of the SuperNEMO Collaboration)

NEMO-3 latest results

The NEMO experiment. Present and Future. Ruben Saakyan UCL 28 January 2004 IOP meeting on double beta decay Sussex

Neutrinoless Double Beta Decay. Phys 135c Spring 2007 Michael Mendenhall

Search for neutrinoless double beta decay: status of SuperNEMO project Yu. Shitov, Imperial

Hugon Christophe Université Aix-Marseille, CPPM, IN2P3/CNRS on behalf of the SuperNEMO collaboration. C. Hugon, rencontre du Vietnam 2017

First results on neutrinoless double beta decay of 82 Se with CUPID-0

Measurement of 2b2ν Half-Life of Zr96. and. Lightguide Studies for SuperNEMO Calorimeter

a step forward exploring the inverted hierarchy region of the neutrino mass

CANDLES Experiment Current Status and Future Plan. X. Li for the CANDLES Collaboration

The GERmanium Detector Array

How can we search for double beta decay? Carter Hall University of Maryland

Status of the AMoRE experiment searching for neutrinoless double beta decay of 100 Mo

The NEXT-100 experiment for Neutrino-less Double Beta decay: Main features, Results from Prototypes and Radiopurity issues.

Search for Majorana neutrinos and double beta decay experiments

SuperNEMO collaboration

Status of Cuore experiment and last results from Cuoricino

cryogenic calorimeter with particle identification for double beta decay search

Proposal for the Super-NEMO design study

NEXT ELECTROLUMINESCENCE READOUT

Experimental Searches for Neutrinoless Double-Beta Decays in 76-Ge Alan Poon

Background Free Search for 0 Decay of 76Ge with GERDA

The NEXT double beta decay experiment

THE NEXT EXPERIMENT FOR NEUTRINOLESS DOUBLE BETA DECAY SEARCHES ANDER SIMÓN ESTÉVEZ ON BEHALF OF THE NEXT COLLABORATION

PHYS 3446 Lecture #12

Topological detection of ββ-decay with NEMO-3 and SuperNEMO

arxiv: v1 [physics.ins-det] 3 Feb 2011

GERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge. Allen Caldwell Max-Planck-Institut für Physik

next The NEXT double beta decay experiment Andrew Laing, IFIC (CSIC & UVEG) on behalf of the NEXT collaboration. TAUP2015, Torino, 8/09/2015

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Double Beta Present Activities in Europe

New results of CUORICINO on the way to CUORE

PoS(HQL2018)054. Search for 0νββ Decay with EXO-200 and nexo. Guofu Cao 1. On behalf of EXO-200 and nexo collaboration

arxiv: v1 [hep-ex] 1 Oct 2015

PROJECT STATUS AND PERSPECTIVES

Par$cle and Neutrino Physics. Liang Yang University of Illinois at Urbana- Champaign Physics 403 April 15, 2014

arxiv: v1 [physics.ins-det] 1 Sep 2009

The CUORE Detector: New Strategies

Extension of the LSM: report of the Scientific Advisory Committee Executive summary

PoS(HEP2005)177. Status of the OPERA experiment. Francesco Di Capua. Universita Federico II and INFN.

Neutrinoless Double Beta Decay for Particle Physicists

AMoRE 0 experiment using low temperature 40 Ca 100 MoO 4 calorimeters

Distillation purification and radon assay of liquid xenon

LUCIFER: AN EXPERIMENTAL BREAKTHROUGH IN THE SEARCH FOR NEUTRINOLESS DOUBLE BETA DECAY

GERDA experiment A search for neutrinoless double beta decay. Roberto Santorelli (Physik-Institut der Universität Zürich)

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

arxiv: v1 [physics.ins-det] 4 Mar 2019

Recent Results and Status of EXO-200 and the nexo Experiment

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

DARWIN: dark matter WIMP search with noble liquids

Neutrino Masses and Mixing

K. Zuber, Techn. Univ. Dresden Cocoyoc, Status of double beta decay searches

R. MacLellan on behalf of the EXO Collaboration Department of Physics & Astronomy, University of Alabama, Tuscaloosa AL USA

XMASS 1.5, the next step of the XMASS experiment

Search for Neutrino-less Double Beta Decay with CANDLES

Neutrinoless Double-Beta Decay

the first prototype for a scintillating bolometer double beta decay experiment.

Two Neutrino Double Beta (2νββ) Decays into Excited States

LUCIFER: Neutrinoless Double Beta decay search with scintillating bolometers

PoS(ICHEP2016)474. SoLid: Search for Oscillations with a Lithium-6 Detector at the SCK CEN BR2 reactor

NINJAExperiment: NINJA. Tsutomu Fukuda(IAR, Nagoya University) on behalf of NINJA collaboration

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

Results from EXO 200. Journal of Physics: Conference Series. Related content PAPER OPEN ACCESS

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

Wavelength Shifting Reflector Foils for Liquid Ar Scintillation Light

Results on neutrinoless double beta decay of 76 Ge from the GERDA experiment

Status and Perspectives of the COBRA-Experiment

Luminescent bolometers for the study of double beta decay. Claudia Nones CEA- IRFU

Search for Neutrinoless Double- Beta Decay with CUORE

Background rejection techniques in Germanium 0νββ-decay experiments. ν=v

Vincenzo Caracciolo for the ADAMO collaboration National Laboratory of Gran Sasso - INFN.

Light ion recoil detector

PoS(NOW2016)003. T2K oscillation results. Lorenzo Magaletti. INFN Sezione di Bari

Status of the EXO double beta decay project. Andreas Piepke for the EXO Collaboration University of Alabama

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

arxiv: v2 [nucl-ex] 6 Oct 2008

Status of CUORE and Results from CUORICINO. SERGIO DI DOMIZIO UNIVERSITÀ & INFN GENOVA On behalf of the CUORE Collaboration

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

Contents. General Introduction Low background activities Pixel activities Summary and Outlook. Kai Zuber

-> to worldwide experiments searching for neutrinoless double beta decay

Double Beta Decay Committee to Assess the Science Proposed for a Deep Underground Science and Engineering Laboratory (DUSEL) December 14-15, 2010

Status of the CUORE experiment at Gran Sasso

Searching for neutrino- less double beta decay with EXO- 200 and nexo

LUCIFER: Neutrinoless Double Beta Decay search with scintillating bolometers

THE CRYOGENIC UNDERGROUND OBSERVATORY FOR RARE EVENTS: STATUS AND PROSPECTS

DOUBLE BETA DECAY OF 106 Cd - EXPERIMENT TGV (Telescope Germanium Vertical) EXPERIMENT SPT (Silicon Pixel Telescope)

Study well-shaped germanium detectors for lowbackground

The next generation dark matter hunter: XENON1T status and perspective

The Majorana Neutrinoless Double-Beta Decay Experiment

Scintillating bolometers for the LUCIFER project. Luca Pattavina INFN-Laboratori Nazionali del Gran Sasso

Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO

RADIOACTIVITY IN THE AIR

arxiv: v1 [physics.ins-det] 20 Dec 2017

Status of the CUORE and CUORE-0 experiments at Gran Sasso

The NEXT experiment Status and prospects, J.J. Gomez-Cadenas on behalf of the NEXT collaboration October, 2015

Searches for Exotic Processes in Double Beta Decay with EXO-200

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Search for Neutrinoless Double-Beta Decay Using Fast Photo-Detectors and Quantum-Dot-Doped Scintillators

The LUCIFER project current status and perspective!!!

PoS(KAON)049. Testing the µ e universality with K ± l ± ν decays

Transcription:

1 arxiv:0710.4279v1 [physics.ins-det] 23 Oct 2007 The SuperNEMO double beta decay experiment I. Nasteva on behalf of the SuperNEMO Collaboration School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester, M13 9PL, UK E-mail: Irina.Nasteva@manchester.ac.uk The SuperNEMO project studies the feasibility of employing a technique of tracking plus calorimetry to search for neutrinoless double beta decay in 100 kg of enriched isotopes. It aims to reach an effective neutrino mass sensitivity of 50 mev. The current status of the SuperNEMO R&D programme is described, focusing on the main areas of improvement. Keywords: SuperNEMO, neutrinoless double beta decay, neutrino mass. 1. Introduction Neutrinoless double beta decay is the most sensitive process for probing lepton number violation. Its discovery would prove that neutrinos are Majorana particles, and would give access to their mass scale. NEMO 3 1 4 is a neutrinoless double beta decay experiment currently running in the Modane Underground Laboratory. Based on its experience and technological expertise, the SuperNEMO project investigates the design of the next generation double beta decay experiment. 2. Goals of the SuperNEMO project SuperNEMO aims to extend and improve the experimental techniques used by the current NEMO 3 experiment to search for neutrinoless double beta decay. It will extrapolate the successful NEMO 3 technology over one order of magnitude by studying about 100 kg of double beta decay isotopes, probably 82 Se or 150 Nd. The experiment will benefit from a relatively short R&D programme, and its first modules can start taking data in 2010. By 2015, SuperNEMO will reach a sensitivity on the half-life of neutrinoless double beta decay of T 1/2 > 2 10 26 years, corresponding to an effective neutrino mass reach of m ν < 50 90 mev.

2 Fig. 1. Preliminary design of the SuperNEMO detector: view from above (left) and three-dimensional cut-away view (right). 3. SuperNEMO detector design To fulfil these physics goals, SuperNEMO will build upon the NEMO 3 technology choice of combining calorimetry and tracking. This gives the ability to measure individual electron tracks, vertices, energies and time of flight, and to reconstruct fully the kinematics and topology of an event. Particle identification of gamma and alpha particles, as well as distinguishing electrons from positrons with the help of a magnetic field, form the basis of background rejection. An important feature of NEMO 3 which is kept in SuperNEMO is the fact that the double beta decay source is separate from the detector, allowing several different isotopes to be studied. SuperNEMO will consist of about twenty identical modules, each housing around 5 kg of isotope. A preliminary design of a SuperNEMO detector module is shown in Fig. 1. The source is a thin ( 40 mg/cm) foil inside the detector. It is surrounded by a gas tracking chamber followed by calorimeter walls. The tracking volume contains more than 2000 wire drift chambers operated in Geiger mode, which are arranged in nine layers parallel to the foil. The calorimeter is divided into 1000 blocks which cover most of the detector outer area and are read out by photo multiplier tubes (PMT).

3 Table 1. Comparison of the main NEMO 3 and SuperNEMO parameters. NEMO 3 SuperNEMO isotope 100 Mo 150 Nd or 82 Se mass 7 kg 100 200 kg signal efficiency 8% > 30% 208 Tl in foil < 20µBq/kg < 2µBq/kg 214 Bi in foil < 300µBq/kg < 10µBq/kg ( 82 Se) energy resolution at 3 MeV 8% (FWHM) 4% (FWHM) half-life T1/2 0ν years T1/2 0ν years neutrino mass m ββ < 0.3 1.3 ev m ββ < 50 90 mev 4. Status of the SuperNEMO R&D programme The SuperNEMO collaboration was formed in 2005 with the goal of carrying out a three-year design study programme (2006 2009) and producing a Technical Design Report (TDR) as outcome. The SuperNEMO R&D programme is currently underway, supported by funding agencies in France, the UK and Spain. The expected improvement in performance of SuperNEMO compared to its predecessor NEMO 3 is shown in Table 1 which compares the parameters of the two experiments. The most important design study tasks are described in the sections that follow. 4.1. Energy resolution An excellent energy resolution is vital for discriminating the neutrinoless double beta decay peak in the energy sum of the two electrons from the background of two-neutrino beta decay. The energy resolution is determined by two factors, the electron energy losses in the foil and the calorimeter resolution. SuperNEMO aims to improve the calorimeter energy resolution to 7%/ E at FWHM (compared to the NEMO 3 resolution of 14%/ E). To reach this goal, several ongoing studies are investigating the choice of calorimeter parameters such as scintillator material (organic plastic, liquid, or non-organic), and the shape, size and coating of calorimeter blocks. These are combined with dedicated development of PMTs with low radioactivity and high quantum efficiency. Initial studies obtain excellent resolution ( 6.5% at 1 MeV) for calorimeter samples of small size; the focus now is to retain this property in larger blocks.

4 Counting rate [Hz] 80 70 60 50 cell 5 cell 2 cell 9 40 30 20 10 0 1550 1600 1650 1700 1750 1800 1850 Applied Voltage Fig. 2. The 9-cell tracker prototype. On the left is a photo of the prototype endplate, containing the cathode rings and the terminations of the anode and ground wires. On the right is a plot of the counting rate dependence on anode voltage. 4.2. Tracker design The SuperNEMO tracker consists of octagonal wire drift cells operated in Geiger mode. Each cell is around 4 m long and has a central anode wire surrounded by 8 12 ground wires, with cathode pickup rings at both ends. Signals can be read out from the anode and/or cathodes to determine the position at which the ionising particle crossed the cell. The tracking detector design study looks at optimising its parameters to obtain high efficiency and resolution in measuring the trajectories of double beta decay electrons, as well as of alpha particles for the purpose of background rejection. The tracking chamber geometry is being investigated with the help of detector simulations to compare the different possible layouts. In addition, several small prototypes have been built to study the drift chamber cell design and size, wire length, diameter and material, and gas mixture. The first 9-cell prototype is shown in the photo on the left of Fig. 2. The prototype was successfully operated with three different wire layouts, demonstrating a plasma propagation efficiency close to 100% over a wide range of voltages (the Geiger regime operational plateau shown in the flat region on the right plot of Fig. 2). The next step is to construct a 100-cell prototype which will test the mechanics and large-scale operation of the drift cell system. A SuperNEMO module will contain several thousand drift cells with

5 8 12 wires each. The large total number of wires has lead to the need of automated wiring. A dedicated wiring robot is being developed for the mass production of drift cells. 4.3. Choice of source isotope The choice of isotope for SuperNEMO is aimed at maximising the neutrinoless signal over the background of two-neutrino double beta decay and other nuclear decays mimicking the process. Therefore the isotope must have a long two-neutrino half-life, and high endpoint energy and phase space factor G 0ν (T1/2 0ν G 1 0ν ). The enrichment possibility on a large scale is also a factor in selecting the isotope. The main candidate isotopes for SuperNEMO have emerged to be 82 Se and 150 Nd. A sample of 4 kg of 82 Se has been enriched and is currently undergoing purification. The SuperNEMO collaboration is investigating the possibility of enriching large amounts of 150 Nd via the method of atomic vapour laser isotope separation. 4.4. Radiopurity of the source SuperNEMO will search for a very rare process, therefore it must maintain ultra-low background levels. The source foils must be radiopure, and their contamination with naturally radioactive elements must be precisely measured. The most important source contaminants are 208 Tl and 214 Bi, whose decay energies are close to the neutrinoless signal region. In order to evaluate their activities, a dedicated BiPo detector is being developed which can measure their signature of an electron followed by a delayed alpha particle. The first BiPo prototype was installed underground in 2006. 5. Conclusion An extensive R&D programme is underway to design the next-generation neutrinoless double beta decay experiment SuperNEMO. It will extrapolate the successful technique of calorimetry plus tracking to 100 kg of source isotope, aiming to reach a neutrino mass sensitivity of 50 mev. Due to its modular approach, SuperNEMO can start operation in stages, with the first module installed as early as 2010, and all twenty modules running by 2012 2013. References 1. R. Arnold et al., Nucl. Instrum. Meth. A536, 79 (2005).

6 2. R. Arnold et al., Phys. Rev. Lett. 95, p. 182302 (2005). 3. R. Arnold et al., Nucl. Phys. A765, 483 (2006). 4. R. Arnold et al., Nucl. Phys. A781, 209 (2007).