Of merica 0 South Powell Road Independence, MO 0 Phone: 0 Fax: Drawing Date : December, 0 Project # : Page # :
OVERRIDE Page Number Equipment over Page Table Of ontents Network ayout ontrol Panel ayouts VV ox ayout nd s RTU ayout nd s RTU- ayout nd s Master ill Of Material Table Of ontents Module Number Page Number Equipment Module Number, Drawing Date : December, 0 Project # : Page # : Special Instruction and Project Scope egend (see bill of material for specific sizes and quantity) Duct veraging erature Sensor Duct erature Probe Duct Humidity Sensor DPDT Freezestat Smoke Detector Flow Sensor Differential Pressure Sensor Well Sensor Room Sensor urrent Sensor O HI Way Valve Electric / Way Valve Way Valve Pneumatic / Way Valve Fan Electronic ctuator Pneumatic ctuator Water Pump D P# HW oils HW Strap On Sensor Transformer ow Voltage wire ine Voltage Wire Pneumatic ine New Terminal T Existing Terminal Pneumatic Point 0 South Powell Road Independence, MO 0 Phone: 0 Fax:
Network ayout E P T D at Ethernet Jack Network Protection oard PROT Terminator (see DIG ) Diagnostic oard DIG entral Site omputer Drawing Date : December, 0 Project # : Page # : aon Unit # ontrol rea aon Unit # ontrol rea T S0 RTU,,, T S0 RTU,,, rc Orange Twisted ed ow ap Wire rc Orange Twisted ed ow ap Wire Phone ine (by others) Modem Roof Field ocate ontrol Panel P RET x G,,, UNI/ RTU- Zones,,, UNet Twisted Stranded lue FP,,, FP,,, FP,,, FPa,,, FP,,, FP,,, FP,,, FP0b,,, FP,,, FP,,, FP,,, FP,,, FPa,,, FP,,,0 FP0a,,, UNI/ RTU- Zones,,, UNet Twisted Stranded lue D P FP,,, FP,,, FP,,, FP,,, FP,,, FP,,, FP,,, FP,,, FP,,, FP0,,,0 FP,,, FP,,, FP,,, FP,,, First Floor FP,,, FP,,, 0 South Powell Road Independence, MO 0 Phone: 0 Fax:
O N UNI UNI n/c 0v n/c n/c Mnet receive Mnet transmit onsole receive onsole transmit onsole receive onsole transmit n/c 0v n/c n/c EI Mnet receive Mnet transmit Unet receive Unet transmit Diag receive Diag transmit dcd rx tx dtr gnd lass Vac 00 Hz.V 0. onductors Only dcd n/c rx 0v tx n/c dtr n/c gnd lass Vac 00 Hz.V 0. onductors Only EI Mnet receive Mnet transmit Unet receive Unet transmit Diag receive Diag transmit dcd rx tx dtr gnd egacy IP ddress Transmit Receive 00/.K aud Default/ssigned R/agacy Gnet ddress 0 / 00 lass Vac 00 Hz.V 0. onductors Only Mnet baud 00.K Mnet baud 00.K O N O N IN0 IN IN0 IN 0 0 Optional 0 0 Optional Universal Input Mode Select 0Vdc Thermistor/ drycontact Universal Input Mode Select 0Vdc Thermistor/ drycontact 00 m.k 00 00.K 00 m.k 00 00.K aud Select aud Select R R aution: To uce the Risk of Fire or Electrical Shock, Do Not interconnect the Outputs of Different lass ircuits. aution: To uce the Risk of Fire or Electrical Shock, Do Not interconnect the Outputs of Different lass ircuits. lass Vac 00 Hz V, 0. onductors Only lass Vac 00 Hz V, 0. onductors Only 0 0 ll Network and I/ O Wiring Main ontrol Panel In Electrical Room RET 0 ontrol Panel ayout 0 Vac RTU ontrols ocated In aon Unit ontrol rea Drawing Date : December, 0 Project # : Page # : ½" X " ½" X " ½" X " G UNI onsole uxiliary Device Diag EI uxiliary Device Ethernet 0 SE T Unet onnection Unet onnection Optional rc 00/.K itch itch Indicator Indicator Off On UNI/ ccess Off On G ccess Ground onnection Vac button Ground onnection Vac button Optional Mnet Net connection Net Optional Mnet Net connection Net T T T T ½" X " MODE NO. TP0 POWER SUPPY N.0 0 HZ V T T U ISTED.0 V 0HZ G M net SHD OFF/ON IR PRODUTS & ONTROS TD N V H NET ON DIG Network Protection oard PWR ED.0 MX HOT WYS OUTET UTION NET OFF ON M P Network Protection oard ½" X " 00 V Vac Factory Supplied Transformer Duct Static Sensor PX-00 ½" X " S0 Input Select Net Net IN IN IN IN IN IN IN IN IN RS IN0 RTU- ontrols ocated In aon Unit ontrol rea Rx net Over RNET Kaud ccess ½" X " 0's 's Module ddress S0 ONTRO MODUE V Max. Max. DO DO DO DO DO DO uto Off On O O O O On Off Vac ½" X " UNI Diag EI uxiliary Device Unet onnection Unet onnection Optional rc 00/.K itch Indicator Off On UNI/ ccess Ground onnection Vac button Optional Mnet Net connection Net T T Modem ½" X " 00 V Vac Factory Supplied Transformer ½" X " S0 ½" X " Input Select IN IN IN IN IN IN IN IN IN IN0 Rx 0's 's Module ddress S0 ONTRO MODUE V Max. Max. DO DO DO DO DO DO uto Off On O O O O ½" X " Net Net net Over RNET Kaud Duct Static Sensor PX-00 RS ccess ½" X " On Off Vac 0 South Powell Road Independence, MO 0 Phone: 0 Fax:
OVERRIDE H00 Fan Status If box fan is fractional horsepower motor, the motor lead will need to be rapped around the solid core ct as many times as necessary to reach. running mps Fan ed Vav ox Tag T Quantity Part Number Uv SPRO /0KD ill Of Material Part Description Uine ontroller With Flow Sensor Digital Outputs, Universal Inputs, nalog Output. Thermostat With Setpoint djust, nd ocal Override, nd Display. Supply ir erature Sensor 0k Thermister H00 urrent itch. mp Trip Fan Status Drawing Date : December, 0 Project # : Page # : Motor T STTUS OPEN STTUS OSED IN Sequence Of Operation Return ir Primary ir Hi ow 0 EM M Motor Voltage: 0...VD urrent imit: md Made in itzerland by elimo utomation M ¼ Poly Tube ¼ Poly Tube T- IN- Uv UTION: This product was designed to be mounted inside the building envelope. Warranty voided if mounted outside. ow Supply ir o Flow Hi Hi lass V 0 0 Hz 0.0 V 0. onductors Only net MSTP Outputs V Max, Max Single lass Source Only for D.O.'s Motor Dir. V On V Off Rx Unet Unet O W W Ones Tens 0 V o g i S t a t VV ontroller Uv DO DO DO USS IN IN Sv US DO- DO- DO- RX TX PWR RUN W W DO DO DO US Duct Heater nd Fan Enable ON V OFF Vac DO- DO- DO- TENS ONES US IN- IN- 0V O- Sv Use Vav box control power transformer provided by the Vav box manufacturer. Green T T DO EETRI HET STGE DO EETRI HET STGE DO IN IN SPORT FN STRT / STOP FN STTUS SUPPY IR TEMPERTURE Supply ir erature Sensor To e Mounted In The Field OGISTT ox Terminals (example) Green Vac Fan Heat Heat If electric duct heater has more than stages of heating tie stage and to DO-. See Duct Heater nd Fan See Duct Heater nd Fan See Duct Heater nd Fan See H00 Wiring Sv ZONE ONTRO (GENER) The zone served by the room sensor will be scheduled. There are modes for each zone: occupied and unoccupied as determined by an operator defined schedule, and override demand levels as determined by the kilowatt meter and operator defined parameters. Each mode has individually adjustable heating and cooling set points. Each zone will have a color associated with the condition of the zone with respect to temperature and the applicable set point. The color will be green when the temperature is between the heating and cooling set point. The color will change progressively from green to yellow, orange, and then red as the temperature rises progressively above the cooling set point. The color will change progressively from green to light blue, dark blue, and then red as the temperature drops progressively below the heating set point. Gray will represent the unoccupied mode. The color changes combined with PID control will execute the required control for the zone (see below for the specific requirements of each type of zone control). Occupied If the zone needs heating the damper will maintain the minimum airflow setpoint. If the zone temperature continues to fall the supply fan will be started and run continually. If the temperature continues to fall the electric heater will be staged to maintain the zone heating setpoint. If the zone needs cooling the vav box damper will be modulated open within design cfm limits. The associated rooftop unit will provide degree (adj.) supply air year round. Unoccupied When the zone is in the unoccupied mode the box damper will close, the fan will be off and the electric heat will be de-energized. If in the unoccupied mode the zone is below the unoccupied heating setpoint the box will start the fan and stage on the electric heating to provide heat to the controlled zone. The air-handling unit will not be started in unoccupied mode. Default vav program will be the same program sequence that will run in the vav controller during normal operation. Fan ed Vav ox 0 South Powell Road Independence, MO 0 Phone: 0 Fax:
Outside Drive Speed 0 Drive Start / Stop 0 M D 0 T 0 H0 VFD (example may not be drive provided) High Duct Static itch FS0DSS N itch NO itch Freeze Stat 0H M N D 0 NO Return Twisted ed Pair Twisted ed Pair HI Safeties such as fire alarm. normally closed, jumper if no safeties exist S 0 O T 0 To Drive Safety See Drive F : 0 Manual ow imit X X 0 0 OM H0 Terminals Twisted Pair Twisted Pair uto ow imit F 0 Start / Stop : 0 Status :0 Speed :0 S 0 Rooftop Unit ll Wire To nd From Drives Will e Twisted ed Wire ll s Will e Grounded t The Drive (Do Not and s In The ontrol Panel). Twisted ed Pair DX Stage - -0- Stage - -0- Stage - -0- Stage - -0- Drive Status 0 High Duct Static 0 T 0 Freeze Stat Status 0 ¼ Poly Tube To PX00. See PX For 0m Wiring Y R DS 0 Range in. in in 0 in m Volts Not Used Relief Supply D 0 P Filter DP V/0V I/UNI JP JP DS Twisted Pair PX-00 Twisted Pair ¼ Poly Tube From Duct Static Pressure Pickup. 0G ow imit N ontacts ine M 0 Exhaust Fan Starter Start / Stop 0 0 ocate PX00 in the control area of the aon unit with the S0. NO ontacts ine 0 M Twisted Pair 0 Tag T D F S S DS 0 Vac Vac itch eg Of Fractional Hp Exhaust Fan Motor QT N.. lock Part Number /0KD S0 G.U 0G P FS0DSS PX00 H0 H0/H K RED N.O. lock H0/H H0 The current switch is not adjustable H The current switch is adjustable Status Output uto Off Hand ill Of Material RED K Part Description " Duct erature Sensor 0 T /0K ' Duct veraging erature Sensor ontrol Module Damper ctuator, Spring Return, 00vdc Modulating ontrol, vac uto Reset Freezestat DPDT F 0H Manual Reset Freezestat DPDT Filter Status itch High Duct Static Safety itch, Manual Reset djustable Static Pressure Sensor 0m urrent itch With Start / Stop Relay Drawing Date : December, 0 Project # : Page # : See PX00 Wiring See 0G- See P See H0 Wiring See rcnet SUPPY FN VFD STTUS 0 SUPPY IR TEMPERTURE 0 MIXED IR TEMPERTURE 0 DUT STTI PRESSURE 0 HIGH DUT STTI SWITH 0 UTO OW IMIT 0 MNU OW IMIT 0 FITER STTUS 0 EXHUST FN STTUS 0 OUTSIDE IR TEMPERTURE 0 RNET OW P ORNGE WIRE IN- IN- IN- IN- IN- IN- IN- IN- IN- IN-0 Net Net- Shld S0 Input Select IN0 IN IN IN IN IN IN 0 IN IN IN IN IN0 0 Net Net Optional RS Sv Rx Thermistor/ drycontact net Over RNET Kaud ccess Universal Input Mode Select 0Vdc 0's 's Module ddress 00 m aud Select.k 00 00.K R S0 ONTRO MODUE V Max. Max. aution: To uce the Risk of Fire or Electrical Shock, Do Not interconnect the Outputs of Different lass ircuits. lass Vac 00 Hz V, 0. onductors Only DO DO DO DO DO DO 0 uto Off On O O O O On Off Vac DO- 0 DO- DO- DO- DO- DO- O- O- O- O- v T T T T T T T T 0 0 0 0 0 EXHUST FN STRT STOP DX OOING STGE DX OOING STGE DX OOING STGE DX OOING STGE See H0 See aon for onnections (not Included) 0 SUPPY FN VFD STRT / STOP 0 SUPPY FN VFD SPEED T T 0 REIEF IR DMPER Vac T T 0 MIXED IR DMPERS Signal Relief Damper Vac will be provided by the aon unit control transformer. See aon documentation for wiring terminations. Vac Signal Outside Damper Vac Signal Return Damper Sequence Of Operation Unoccupied During the unoccupied mode the supply fan will be off the outside air damper will be closed the return air damper will be open and the DX cooling will be de-energized. The Rooftop unit will not be started in the unoccupied mode. Occupied During the occupied mode the supply fan will run continually. The supply fan VFD will be modulated to maintain the duct static pressure setpoint of." W (adj.). When the outside air temperature is below the economizer enable setpoint of 0 F (adj.), the mixed air damper will modulate open to the outside air to maintain the cooling supply air temperature setpoint. The relief air damper will lag the outside air damper by 0% (adj.). When the outside air temperature is above 0 F (adj.) the dx cooling will stage on to maintain the supply air temperature setpoint (adj.). ll DX cooling stages will have a minute anti-recycle timer to limit compressor cycling. During the occupied mode the outside air damper will be modulated open to 0% to allow for fresh air requirements. n auto-reset low limit temperature controller will be set at F (adj.) to close the outside air dampers and alarm the central workstation should the mixed air temperature be below F (adj.). If the mixed air temperature continues to fall the manual-reset low limit temperature controller set for F (adj.) will shut down the supply fan and alarm the central workstation. The supply air temperature setpoint will be F (adj.). 0 South Powell Road Independence, MO 0 Phone: 0 Fax:
Outside Drive Speed 0 Drive Start / Stop 0 M D 0 T 0 H0 VFD (example may not be drive provided) High Duct Static itch FS0DSS N itch NO itch Freeze Stat 0H M N D 0 NO Return Twisted ed Pair Twisted ed Pair HI Safeties such as fire alarm. normally closed, jumper if no safeties exist S 0 O T 0 To Drive Safety See Drive F : 0 Manual ow imit X X 0 0 OM H0 Terminals Twisted Pair Twisted Pair uto ow imit F 0 Start / Stop : 0 Status :0 Speed :0 S 0 Rooftop Unit ll Wire To nd From Drives Will e Twisted ed Wire ll s Will e Grounded t The Drive (Do Not and s In The ontrol Panel). Twisted ed Pair DX Stage - -0- Stage - -0- Stage - -0- Stage - -0- Drive Status 0 High Duct Static 0 T 0 Freeze Stat Status 0 T Range in. in in 0 in m Volts Not Used Thermistor Sensor ¼ Poly Tube To PX00. See PX For 0m Wiring V/0V I/UNI DS 0 JP JP DS Twisted Pair Relief Supply PX-00 Thermistor Twisted Pair ¼ Poly Tube From Duct Static Pressure Pickup. 0G ow imit N ontacts ine M ontrol Module Thermister Thermister Gravity Relief Damper Y R Exhaust Fan Starter Start / Stop 0 0 P Filter DP 0 ocate PX00 in the control area of the aon unit with the S0. NO ontacts ine 0 M Twisted Pair Twisted Pair 0 Tag T D F S S DS 0 Vac Vac itch eg Of Fractional Hp Exhaust Fan Motor QT N.. lock Part Number /0KD S0 G.U 0G P FS0DSS PX00 H0 H0/H K RED N.O. lock H0/H H0 The current switch is not adjustable H The current switch is adjustable Status Output uto Off Hand ill Of Material RED K Part Description " Duct erature Sensor 0 T /0K ' Duct veraging erature Sensor ontrol Module Damper ctuator, Spring Return, 00vdc Modulating ontrol, vac uto Reset Freezestat DPDT F 0H Manual Reset Freezestat DPDT Filter Status itch High Duct Static Safety itch, Manual Reset djustable Static Pressure Sensor 0m urrent itch With Start / Stop Relay Drawing Date : December, 0 Project # : Page # : See PX00 Wiring See 0G- See P See H0 Wiring See rcnet SUPPY FN VFD STTUS 0 SUPPY IR TEMPERTURE 0 MIXED IR TEMPERTURE 0 DUT STTI PRESSURE 0 HIGH DUT STTI SWITH 0 UTO OW IMIT 0 MNU OW IMIT 0 FITER STTUS 0 EXHUST FN STTUS 0 OUTSIDE IR TEMPERTURE 0 RNET OW P ORNGE WIRE IN- IN- IN- IN- IN- IN- IN- IN- IN- IN-0 Net Net- Shld S0 Input Select IN0 IN IN IN IN IN IN 0 IN IN IN IN IN0 0 Net Net Optional RS Sv Rx Thermistor/ drycontact net Over RNET Kaud ccess Universal Input Mode Select 0Vdc 0's 's Module ddress 00 m aud Select.k 00 00.K R S0 ONTRO MODUE V Max. Max. aution: To uce the Risk of Fire or Electrical Shock, Do Not interconnect the Outputs of Different lass ircuits. lass Vac 00 Hz V, 0. onductors Only DO DO DO DO DO DO 0 uto Off On O O O O On Off Vac DO- 0 DO- DO- DO- DO- DO- O- O- O- O- v T T T T T T T T T T 0 0 0 0 0 EXHUST FN STRT STOP DX OOING STGE DX OOING STGE DX OOING STGE DX OOING STGE 0 SUPPY FN VFD SPEED See H0 See aon for onnections (not Included) 0 SUPPY FN VFD STRT / STOP 0 MIXED IR DMPERS Vac will be provided by the aon unit control transformer. See aon documentation for wiring terminations. Vac Signal Outside Damper Vac Signal Return Damper Sequence Of Operation Unoccupied During the unoccupied mode the supply fan will be off the outside air damper will be closed the return air damper will be open and the DX cooling will be de-energized. The Rooftop unit will not be started in the unoccupied mode. Occupied During the occupied mode the supply fan will run continually. The supply fan VFD will be modulated to maintain the duct static pressure setpoint of." W (adj.). When the outside air temperature is below the economizer enable setpoint of 0 F (adj.), the mixed air damper will modulate open to the outside air to maintain the cooling supply air temperature setpoint. When the outside air temperature is above 0 F (adj.) the dx cooling will stage on to maintain the supply air temperature setpoint (adj.). ll DX cooling stages will have a minute antirecycle timer to limit compressor cycling. During the occupied mode the outside air damper will be modulated open to 0% to allow for fresh air requirements. n auto-reset low limit temperature controller will be set at F (adj.) to close the outside air dampers and alarm the central workstation should the mixed air temperature be below F (adj.). If the mixed air temperature continues to fall the manual-reset low limit temperature controller set for F (adj.) will shut down the supply fan and alarm the central workstation. The supply air temperature setpoint will be F (adj.). 0 South Powell Road Independence, MO 0 Phone: 0 Fax:
Master ill Of Material Drawing Date : December, 0 Project # : Page # : ill Of Material QT Part Number Part Description /0KD " Duct erature Sensor /0K ' Duct veraging erature Sensor S0 ontrol Module G.U Damper ctuator, Spring Return, 00vdc Modulating ontrol, vac 0G uto Reset Freezestat DPDT 0H Manual Reset Freezestat DPDT P Filter Status itch FS0DSS High Duct Static Safety itch, Manual Reset PX00 djustable Static Pressure Sensor 0m H0 SPRO H00 UNI/ G urrent itch With Start / Stop Relay VV ontroller Thermostat With Setpoint djust, nd Timed ocal Override and Display urrent itch With. mp Trip Point ontrol Module for Networking Gateway ontroller For The utomated ogic ontrol System RET 0 South Powell Road Independence, MO 0 Phone: 0 Fax: ontrol Panel TP0 Vac ontrol Transformer PROT Network Protection oard DIG Network Module With Terminator Resisters Modem K Modem With Modem able Dell omputer Dell omputer, Windows 000 Operating System With Printer