International Journal of Advance Engineering and Research Development

Similar documents
Effect of bearing characteristics on the response of friction pendulum base-isolated buildings under three components of earthquake excitation

Aseismic design of structure equipment systems using variable frequency pendulum isolator

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

Introduction to structural dynamics

Seismic design of bridges

Preliminary Examination in Dynamics

SEISMIC BASE ISOLATION

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING

SEISMIC RELIABILITY ANALYSIS OF BASE-ISOLATED BUILDINGS

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

Boundary Nonlinear Dynamic Analysis

Preliminary Examination - Dynamics

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

Structural Dynamics Prof. P. Banerji Department of Civil Engineering Indian Institute of Technology, Bombay. Lecture - 1 Introduction

INFLUENCE OF FRICTION MODELS ON RESPONSE EVALUATION OF BUILDINGS WITH SLIDING ISOLATION DEVICES

midas Civil Dynamic Analysis

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

Design of Structures for Earthquake Resistance

PROTECTING PRECISION MACHINERY USING GUIDEWAY SLIDING ISOLATOR WITH GAP SPRING AND DAMPERS

Effective Stiffness and Period of Friction Bearing Devices with one Concave Sliding Surface for Different Load Conditions

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

Structural Dynamics Lecture 7. Outline of Lecture 7. Multi-Degree-of-Freedom Systems (cont.) System Reduction. Vibration due to Movable Supports.

Stochastic Dynamics of SDOF Systems (cont.).

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

RESPONSE SPECTRUM METHOD FOR ESTIMATION OF PEAK FLOOR ACCELERATION DEMAND

Response Analysis for Multi Support Earthquake Excitation

Tuning TMDs to Fix Floors in MDOF Shear Buildings

CE6701 STRUCTURAL DYNAMICS AND EARTHQUAKE ENGINEERING QUESTION BANK UNIT I THEORY OF VIBRATIONS PART A

Codal Provisions IS 1893 (Part 1) 2002

EXPERIMENTAL VALIDATION OF RE-CENTRING CAPABILITY EVALUATION BASED ON ENERGY CONCEPTS

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

1. Multiple Degree-of-Freedom (MDOF) Systems: Introduction

Effect of Dampers on Seismic Demand of Short Period Structures

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

VARIABLE COEFFICIENT OF FRICTION: AN EFFECTIVE VFPI PARAMETER TO CONTROL NEAR-FAULT GROUND MOTIONS

Dynamics of structures

Displacement ductility demand and strength reduction factors for rocking structures

MODELLING OF TRIPLE FRICTION PENDULUM BEARING IN SAP2000

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

Inclusion of a Sacrificial Fuse to Limit Peak Base-Shear Forces During Extreme Seismic Events in Structures with Viscous Damping

SPECIAL DYNAMIC SOIL- STRUCTURE ANALYSIS PROCEDURES DEMONSTATED FOR TWO TOWER-LIKE STRUCTURES

ANALYSIS OF HIGHRISE BUILDING STRUCTURE WITH SETBACK SUBJECT TO EARTHQUAKE GROUND MOTIONS

EQ Ground Motions. Strong Ground Motion and Concept of Response Spectrum. March Sudhir K Jain, IIT Gandhinagar. Low Amplitude Vibrations

NON-LINEAR VISCOELASTIC MODEL OF STRUCTURAL POUNDING


ME 563 HOMEWORK # 7 SOLUTIONS Fall 2010

Address for Correspondence

EARTHQUAKES AND EARTHQUAKE-RESISTANT DESIGN OF STRUCTURES. Er. K. S. BHARGAV LECTURER Department of Civil Engineering, GGSGP CHEEKA

Wire rope springs for passive vibration control of a light steel structure

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS

NUMERICAL ANALYSIS OF ELEVATED FRAMED STAGING SHALLOW TANK BY NEWMARK S STEP-BY-STEP METHOD

CE210 January 3:0 Structural Dynamics

Comparative Study of Impact Simulation Models for Linear Elastic Structures in Seismic Pounding

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION

Finite Element Modules for Demonstrating Critical Concepts in Engineering Vibration Course

SHAKING TABLE DEMONSTRATION OF DYNAMIC RESPONSE OF BASE-ISOLATED BUILDINGS ***** Instructor Manual *****

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

REAL-TIME HYBRID EXPERIMENTAL SIMULATION SYSTEM USING COUPLED CONTROL OF SHAKE TABLE AND HYDRAULIC ACTUATOR

International Journal of Emerging Technologies in Computational and Applied Sciences (IJETCAS)

FORMULA FOR FORCED VIBRATION ANALYSIS OF STRUCTURES USING STATIC FACTORED RESPONSE AS EQUIVALENT DYNAMIC RESPONSE

Three dimensional non-linear analysis of building pounding during earthquakes M. Papadrakakis", H.P. Mouzakis\ A.S. Alevridis^

CE 6701 Structural Dynamics and Earthquake Engineering Dr. P. Venkateswara Rao

Vibration Control Prof. Dr. S. P. Harsha Department of Mechanical & Industrial Engineering Indian Institute of Technology, Roorkee

Behaviour of asymmetric building with double variable frequency pendulum isolator

DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS

Design of Earthquake-Resistant Structures

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

Dynamics of Structures

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

Design Procedures For Dynamically Loaded Foundations

Combined Effect of Soil Structure Interaction and Infill Wall Stiffness on Building_- A Review

EFFECT OF BOUNDARIES ISOLATION ON DYNAMIC RESPONSE OF PILE GROUPS

IMPORTANT FEATURES OF THE RESPONSE OF INELASTIC STRUCTURES TO NEAR-FIELD GROUND MOTION

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

COMPARISON OF LABVIEW WITH SAP2000 AND NONLIN FOR STRUCTURAL DYNAMICS PROBLEMS

Centrifuge Modelling of the Energy Dissipation Characteristics of Mid-Rise Buildings with Raft Foundations on Dense Cohesionless Soil

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

STRUCTURAL DYNAMICS BASICS:

A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP,

Modal analysis of shear buildings

Estimation of damping capacity of rubber vibration isolators under harmonic excitation

Damping from bearing hysteresis in railway bridges

Chapter 14: Periodic motion

BIRLA INSTITUTE OF TECHNOLOGY AND SCIENCE, Pilani Pilani Campus

Harmonized European standards for construction in Egypt

An Evaluation of the Force Reduction Factor in the Force-Based Seismic Design

DEVELOPMENT OF A REAL-TIME HYBRID EXPERIMENTAL SYSTEM USING A SHAKING TABLE

Variable friction pendulum system for seismic isolation of liquid storage tanks

Giacomo Boffi. Dipartimento di Ingegneria Civile Ambientale e Territoriale Politecnico di Milano

INVESTIGATION OF JACOBSEN'S EQUIVALENT VISCOUS DAMPING APPROACH AS APPLIED TO DISPLACEMENT-BASED SEISMIC DESIGN

Investigation of semi-active control for seismic protection of elevated highway bridges

Simple Harmonic Motion Test Tuesday 11/7

DUCTILITY BEHAVIOR OF A STEEL PLATE SHEAR WALL BY EXPLICIT DYNAMIC ANALYZING

Transcription:

Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 11, November -2017 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Study of Friction Pendulum (FPS) Isolation System in Seismic Control of Structures Amit Purohit 1 1 Lecturer, Department of Civil Engineering, Govt. Polytechnic College, Jodhpur, Rajasthan, India Abstract Base isolation systems are very effective in reducing the forces transmitted to the structure, either by detuning the structure from the ground motion as in laminated rubber bearing system or by isolating the structure by introducing a sliding layer between the structure and foundation raft, thereby limiting the forces transferred to the structure. Pure friction system is the simplest sliding isolator consisting of a horizontal sliding surface; however, it may experience large sliding and residual displacements, which are often difficult to incorporate in structural design. Several systems have been suggested in the past to accommodate the restoring mechanism along with sliding in order to reduce the sliding and residual displacements to manageable levels. The FPS is based on an innovative way of achieving a pendulum motion. Based on our research study, it can be concluded that FPS system have several advantages and disadvantages. Thus based on the requirements, optimum choice has to be made in choosing the parameters so that the forces in the structure are reduced without compromising for sliding displacements. Keywords-Friction Pendulum System; Seismically Structure; Structural Control I. INTRODUCTION Seismic isolation is the separation of the structure from the harmful motions of the ground by providing flexibility and energy dissipation capability through the insertion of the so called isolators between the foundation and the superstructure. It is not a long time since the first application of the isolators as the first base-isolated building in the USA was built in 1985, although the idea is more than a century years old. It was found pure friction isolation system these systems are quite effective in reducing forces transmitted to the structure. Their main disadvantage is the large sliding and residual displacements left as there is no restoring mechanism to bring the structure back to its original position. This limitation of isolation system can be overcome by introducing a suitable restoring mechanism in the isolation system to bring the structure back to its original position after the end of ground excitations. One of the most effective mechanisms has been used in the friction pendulum systems. The FPS uses a spherical sliding surface that incorporates restoring mechanism through gravity. It uses geometry and gravity to achieve the desired seismic isolation results. It is based on principles of pendulum motion. In this chapter, it is intended to study the friction pendulum system and compare the response for FPS isolated structure with that of pure friction isolated structure. During sliding the isolator provides restoring force and frictional force. Frictional force is provided by the weight of the structure sliding on the curved surface, which always acts towards the lowest point on the isolator and frictional force acts opposite to the relative sliding velocity. The effect of isolator restoring force and sliding friction can be represented by means of a spring and friction damper respectively. Important parameters affecting the response quantities are structural properties and the isolator properties. The structural properties affecting the response are fixed base time period, mass ratio and damping ratio. The damping ratio is usually unique for a given structure as it depends on the materials used. The investigations have been carried out for a fixed damping ratio of 5%. The isolator properties affecting the response quantities are isolator time period and the coefficient of sliding friction. In addition to these, the behaviour also depends on the ground motion characteristics, like the frequency content and the intensity of ground motion. II. SINGLE DEGREE OF FREEDOM STRUCTURE In the subsequent sections, parametric studies on SDOF structures isolated by two sliding type isolators namely, friction pendulum systems and pure friction isolator subjected to base excitation are carried out. The objective of this study is to critically assess the influencing parameters that control the behaviour of structures isolated by the frictional type isolators with and without restoring force mechanism and determine their relative advantages and disadvantages. Structure is subjected to harmonic excitations and NS component of El Centro 1940 earthquake excitation. The ground motion record used has a digitized data at a time interval of 0.02s and a peak ground acceleration of 0.319g. The duration of the earthquake is 30s. Typical time history plots for sinusoidal excitation for structure isolated by FPS are shown in Figure 1. The plot is for resonant conditions. Coefficient of friction is 0.1, damping coefficient 0.05 and mass ratio 0.5. There is a substantial reduction in the absolute acceleration and relative displacement of the structure as compared to that of the fixed base structure. From the Figure 3, the effect of restoring force of the isolator is evident. A structure isolated using PF system @IJAERD-2017, All rights Reserved 612

International Journal of Advance Engineering and Research Development (IJAERD) displaces itself to an offset from the initial position and starts oscillating about the displaced position, while the structure isolated by FPS immediately comes back to its original position and oscillates. The typical time history plots for a SDOF structure subjected to NS component of El Centro 1940 ground motion are shown on Figure 4-6. Time period of the chosen structure is 0.5s and mass ratio taken as 0.5. Coefficient of damping is 0.02. As it can be seen from Figures 4-6, the response is reduced throughout the time history. In the case of PF system the structure displaces itself to an offset and oscillates about that, but in the case of FPS structure after moving an offset comes back to its original position and oscillates about that. The sliding displacement after the ground motion is over is much less in case of FPS as compared to that of the PF system. This is because of the restoring force which tends to reduce the amplitudes of the sliding displacements. The effectiveness of the restoring mechanism of the isolator is again observed from the residual displacement at the end of the ground motion. As stated earlier, the structure almost comes to its original position in case of the FPS isolated structure whereas the PF system results in a very large residual displacement. 2.1 Effect of Structural Flexibility The structural flexibility is represented by the natural period of the fixed base structure. The effect of structural flexibility can be studied by plotting the maximum response quantities against the fixed-base time period. It is seen that the acceleration response and displacement response of structure isolated with FPS is significantly greater than that with the PF system. This is more evident for structures with higher flexibility. This is because the time period of the fixed base structure approaches that of the FPS isolator time period. It is seen that the acceleration response and displacement response of structure isolated with FPS is significantly greater than that with the PF system. This is more evident for structures with higher flexibility. This is because the time period of the fixed base structure approaches that of the FPS isolator time period. So, there is a possibility of resonance between the structure and the isolator. This is not for the PF system as the force transmitted in this case is limited to the frictional force and the time period of the isolator is infinity. There is a substantial reduction in the sliding and residual displacements in case of FPS isolated structure. The residual displacements are close to zero in case of FPS, which shows the effectiveness of restoring force mechanism. Thus it can be seen that the FPS is not effective when the excitation is of high intensity. In such a case PF behaves in a better way reducing the response significantly but with the major deficiency of large sliding and residual displacements. 2.2 Effect of Coefficient of Friction The coefficient of friction is an important parameter directly affecting the behaviour, as it is mainly responsible for restricting the forces to the structure. The isolators with lesser coefficient of friction are more effective in reducing the peak structural acceleration but at the disadvantage of large sliding displacements. This is because the force transmitted to the superstructure is limited to the sum of the frictional force and the restoring force. As expected, a lower coefficient of friction transfers a lower force to the superstructure. At the same time this is true only if the restoring force component is less in compared to the frictional force. Otherwise there may be an increase in the acceleration with decrease in the coefficient of friction as seen for the high intensity excitation. Due to this there is a significant difference in the behaviour of FPS and PF systems for lower coefficient of friction and higher intensity of earthquake. The sliding displacements in case of FPS are significantly lesser than that of the PF system. There is a marginal increase in the residual displacements with increase in coefficient of friction because there is a higher resistance for the structure to come back to its original position with higher coefficient of friction. From Figure 7-9, it can be seen that for low value of the coefficient of friction PF system is more effective as compared to FPS in reducing the forces in the structure but the displacements are very large. It can also be observed from Figure 5.8 and 5.9 that after some value of coefficient of friction the residual sliding displacement becomes constant, there is no significant change in the sliding and residual displacement whereas the absolute acceleration is still increasing with increasing coefficient of friction. Based on this observation it can be concluded that for an optimum values of different parameters chosen and site condition, the response of the structure can be controlled in an effective way. 2.3 Effect of Isolator Time Period The magnitude of the isolator restoring force is inversely proportional to the isolator time period. The restoring force offered by a PF system is zero and hence its isolator period is infinity. The isolator time period refers to the time period of a rigid body on the isolator without the effect of frictional force. To study the effect of the isolator period on the response, the response spectra are plotted against the isolator period keeping the coefficient of friction constant. Figure 10 show the spectra for coefficients of friction of 0.02, 0.05 and 0.10 for El Centro ground motion. It can be observed that the isolator time period has negligible effect on the peak accelerations of the structure for higher coefficients of friction. This is because for higher coefficient of friction, the sliding displacements are lesser and the low restoring force does not affect the behaviour significantly. But for isolators with lesser friction, the accelerations decrease with the increase in isolator time period. However this decrease is negligible for higher isolator periods. This is because for large isolator time period, the restoring effect reduces and the behaviour approaches that of a PF system. It is also important to note that the response for a lower coefficient of friction is quite high for stiffer isolators. This is due to the high restoring force which leads to additional energy for high intensity excitations. So, a lesser coefficient of friction will not increase the isolation efficiency in case of FPS unlike PF system. @IJAERD-2017, All rights Reserved 613

International Journal of Advance Engineering and Research Development (IJAERD) On the other hand, the sliding displacements and the residual displacements increase with the increase in isolator period. This is expected, as the effect of restoring force is lesser for higher isolator periods. The sliding displacements are higher for lower coefficient of friction. But the residual displacements are lesser for lower coefficient of friction. This is because the sliding surface offers less resistance for the structure to come back. However the restoring force should be sufficiently large to bring the structure back to its original position. Both the sliding and residual displacements approach that of the PF system for higher time periods. It is interesting to note that the sliding displacement may be even greater than that of a PF system in certain cases. This is possible for a low coefficient of friction and high intensity of earthquake. This is because in such a case, the high restoring force may act as a driving force inducing higher sliding displacements. From the above discussion, it is clear that the response is affected by the total isolator force (restoring force and frictional force). For a given coefficient of friction and given isolator period the restoring force increases almost linearly with sliding displacement which means the effectiveness of the FPS is questionable for higher sliding displacements. This is not the case with PF system as there is no restoring force and so the acceleration transmitted is limited to making the response independent of the frequency content of excitation. So, in case of FPS the high magnitude of the restoring force feeds additional energy into the structure for high intensity excitations whereas in case of PF system there is no additional energy fed into the structure due to the absence of the restoring force. The curved sliding surface provides the restoring force by gravity and the isolator period represents the magnitude of this force. The total isolator force governs the isolator performance. For lesser restoring force or higher frictional force, the FPS isolator acts similar to a PF system and the frictional force primarily governs the behaviour. The relative values of these two forces depend upon the extent to which the structure slides. So, it is quite clear that for large sliding displacements as in case of a high intensity earthquake and a lower coefficient of friction, the restoring force component feeds more energy into the structure. III. MULTIPLE DEGREE OF FREEDOM STRUCTURE In this paper it is intended to study various aspects of the behaviour of a MDOF structure isolated by FPS system subjected to earthquake ground motion. The effect of various parameters influencing the response is studied. In this section the effectiveness of FPS system on response of MDOF structures subjected to earthquake excitations has been considered. The NS component of El Centro 1940 earthquake has been chosen for the study and time history analysis is carried out for a five storey shear structure. The model of the example shear building is shown in Figure 11. The structure is represented as a lumped mass model with equal masses of 60080 kg and equal storey stiffness of 112600 kn/m. The results are compared with the same with the same structure isolated with PF system. The FPS used has a time period of 2.0s (R = 1m). 3.1 Time History Response The time history plots for response quantities are shown in Figure 12. The response quantities of interest are acceleration of the top storey and sliding displacement. In the case of FPS the force transmitted to the superstructure is directly proportional to the isolator displacements. For example, the base shear transmitted in FPS is higher when the sliding displacement is more. The accelerations in the case of FPS is little higher than that of PF system. From Figure 12, it is observed that for FPS the sliding displacements increase, which is due to the fact that the effective isolator force in FPS can act either as restoring force or driving force depending on the direction of motion. 3.2 Modal Contributions In this section the response contributions in different modes are discussed for the example system. If modes of the superstructure are considered in the analysis then the complex modal analysis is required to be carried out for an order of However, the analysis is carried out for normal modes in the case of non-sliding phase. It is observed that the first mode of the isolated structure predominantly consists of the displacement at the isolator level whereas the first mode of the fixed base structure is dominated by the displacement in the structure. The deformation in the structure in the first mode of the isolated structure is negligible. The second mode in the isolated structure is dominated by the deformation in the structure. These two modes have a significant contribution in the overall behaviour of the structure and the isolator. So the first two modes of the isolated structure are usually found sufficient for the assessment of the various response quantities. In the isolated structure the first mode is virtually a rigid-body mode corresponding to the isolator displacement and the second mode is due to the deformation in the structure. So, the response of a MDOF structure primarily depends on the first two modes. However it should be noted that the total response consists of successive non-sliding and sliding phases and the effective participation of higher modes may be significant. IV. RESULT DISCUSSION Though FPS has several advantages but it cannot serve as a suitable isolator, for structures under a variety of dynamic loads. Any isolator for the structure has to serve two basic purposes: 1. It has to be stiff enough under ambient vibrations and minor earthquakes 2. It should provide a fail-safe mechanism under extreme earthquake loading conditions @IJAERD-2017, All rights Reserved 614

International Journal of Advance Engineering and Research Development (IJAERD) FPS has a constant time period and a linearly varying restoring force. The high stiffness required under normal working conditions can be provided, by decreasing the radius of curvature. But this may affect the performance of the isolator under medium and high intensity excitations as high amount of restoring force induces additional energy into the structure. So the basic purpose of isolating the structure may not be served. On the other hand, the radius can be increased so that the isolator performs well under higher level of excitations. Again, a too low stiffness will affect the performance of the isolator under normal working conditions. In fact the isolator may act similar to a PF system at low level of excitations also, leading to unacceptable sliding and residual displacements. So, FPS isolator can perform at its best under a minor range of excitations for which it has been designed In case of a PF system, lower value of coefficient of friction will lead to lower response and correspondingly with higher sliding displacements. But this is not necessarily possible in the case of FPS system. This is because the force transmitted to the structure in the case of FPS is the sum of frictional and restoring force. The restoring force will govern the response for a lower frictional force. If the frictional force is less, it leads to higher sliding displacements and hence higher restoring force. This feeds more energy in the structure and increases the response. Limitations of the FPS can be summarized as follows: 1. A properly designed FPS can perform well only under a small range of excitations 2. If the response is to be fairly independent of frequency if frequency content and amplitude of excitation for a wide range of excitations, the radius of the isolator has to be quite large and this may affect the stability under normal working conditions 3. A low level of coefficient of friction may not be beneficial to FPS and hence the low friction isolating capability cannot be used effectively On the other hand the PF system has the major advantage that the behaviour of structures isolated by PF system is independent of the frequency and amplitude of base excitation. The PF system acts like an isolator for all levels ground excitation. The PF system is always detuned with the ground motion giving a very satisfactory performance under a variety of base excitations. But this has a major disadvantage of large sliding and residual displacement. Figure 1 Absolute Acceleration for FPS isolated SDOF system subjected to harmonic acceleration Figure 2 Structural displacement for FPS isolated SDOF system subjected to harmonic excitation @IJAERD-2017, All rights Reserved 615

Relative Displacement (m) Absolute Acceleration (g) International Journal of Advance Engineering and Research Development (IJAERD) Figure 3 Sliding displacement for FPS isolated SDOF system subjected to harmonic excitation 0.8 0.6 0.4 0.2 0.0-0.2-0.4-0.6-0.8 Figure 4 Absolute Acceleration for FPS isolated SDOF system subjected to El Centro (1940) 0.06 0.02-0.02 - -0.06 Figure 5 Relative displacement for FPS isolated SDOF subjected to El Centro (1940) @IJAERD-2017, All rights Reserved 616

Sliding Displacement (m) Absolute Acceleration (g) Sliding Displacement (m) International Journal of Advance Engineering and Research Development (IJAERD) 0.08 0.06 0.02-0.02 - -0.06-0.08 Figure 6 Sliding displacement for FPS isolated SDOF subjected to El Centro (1940) 0.40 0.36 0.32 0.28 0.24 0.20 0.16 0.12 0.08 PF FPS 0.05 0.10 0.15 0.20 Coefficient of Friction Figure 7 Effect of coefficient of friction on peak acceleration 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 PF FPS 0.02 0.05 0.10 0.15 0.20 Coefficient of Friction Figure 8 Effect of coefficient of friction on peak sliding displacement @IJAERD-2017, All rights Reserved 617

Absolute Acceleration (g) Residual Sliding Displacement (m) International Journal of Advance Engineering and Research Development (IJAERD) 0.20 0.16 0.12 0.08 PF FPS 0.05 0.10 0.15 0.20 Coeff of Friction Figure 9 Effect of coefficient of friction on peak residual displacement 0.8 Coefficient of friction 0.6 0.02 0.05 0.10 0.4 0.2 0.0 1 2 3 4 5 6 Isolator Time Period (s) Figure 10 Effect of isolator time period on peak acceleration for FPS Figure 11 Five storey example shear structure isolated by sliding type isolator @IJAERD-2017, All rights Reserved 618

Sliding Displacement (m) Absolute Acceleration (g) International Journal of Advance Engineering and Research Development (IJAERD) 0.3 0.2 0.1 0.0-0.1-0.2-0.3 (a) Absolute acceleration 0.20 0.15 0.10 0.05-0.05-0.10-0.15-0.20 (b) Sliding displacement Figure 12 Response quantities for five storey shear building subjected to El Centro V. CONCLUSION The dynamic behaviour of FPS and PF isolated structures are examined through a parametric study on SDOF structural models. A five storey shear building is also considered for the study to compare the effectiveness of FPS and PF system for MDOF systems also. Friction pendulum system also uses friction in reducing the forces transferred to the structure. It uses its weight as a restoring force. They behave similar to the pure friction system in reducing the forces with an additional advantage of smaller residual displacements. In FPS the restoring force is directly proportional to the sliding displacement; therefore, in case of large sliding displacements the restoring force acts as driving force thus introducing increased energy content of the structure. Thus FPS is not very useful in case of low coefficient of friction and high excitations. Based on the results obtained for the FPS isolated structures, following conclusions can be made: 1. In the FPS system, the restoring force is provided by gravity and is dependent on mass of the structure and geometry of the isolator. This makes the system more reliable than the other restoring force mechanisms like spring, elastic material like rubber 2. The structure can be subjected to a ground motion which has a wide range of frequencies. The behaviour of FPS is fairly independent of frequency content of excitation for low magnitudes of restoring forces. 3. As the isolator time period depends on the geometry of the isolator the calculated time period is quite reliable and can be decided simply by choosing the radius of the isolator. The isolator time period is independent of mass of the structure. REFERENCES [1] Cheng, F.Y. (2001). Matrix Analysis of Structural Dynamics, First Edition, Marcel Dekker Publication, New York, USA. [2] Chopra, A.K. (2001). Dynamics of Structure, Second Edition, Pearson Education Asia, New Delhi. [3] Clough,R.K., and Penzien, J (1993). Dynamics of Structures, Second Edition, McGraw-Hill Book Co., Singapore. @IJAERD-2017, All rights Reserved 619

International Journal of Advance Engineering and Research Development (IJAERD) [4] Guiraud, R., Noelleroux, J.P., Livolant, M. and Michalopoulos, A.P. (1985) Seismic Isolation Using Sliding- Elastomer Bearings. Nuclear Engineering and Design, 84, 363-377 [5] Hoffmann, G.K. (1985). Full Base Isolation for Earthquake Protection by Helical Springs and Viscodampers. Nuclear Engineering and Design, 84, 331-338. [6] Mostaghel, N., Hejazi, M. and Tanbakuchi, J (1983). Response of Sliding Structures to Harmonic Support Motion. Journal of Earthquake Engineering and Structural Dynamics, 11, 355-366. [7] Mostaghel, N., Hejazi, M. and Tanbakuchi, J (1983). Response of Sliding Structures to Earthquake Support Motion. Journal of Earthquake Engineering and Structural Dynamics, 11, 729-748. [8] Mostaghel, N. and Khodaverdian, M. (1987). Dynamics of Resilient-Friction Base Isolator (R-FBI). Journal of Earthquake Engineering and Structural Dynamics, 15, 379-390. [9] Pranesh, VFPI: An Innovative Device for Aseismic Design, PhD Thesis, IIT Bombay, 2002 [10] Pranesh, M. and Sinha, R. (2002). Earthquake Resistant Design of Structures using the Variable Frequency Pendulum Isolator. Journal of Structural Engineering, 128, 870-880. [11] Robinson, W.H. (1982). Lead-Rubber HystereticBearings Suitable for Protecting Structures During Earthquakes. Journal of Earthquake Engineering and Structural Dynamics, 10, 593-604. [12] Sinha, R. (1993). Non-Classically Damped Structures. One Week Interaction Programme on State-of-the-Art On Seismic Qualification of Structures and Systems. Lecture Notes, Complied by R.S.Soni, 71-80. [13] Skinner, R.I., Beck, J.L. and Bycroft, G.N. (1975). A Practical System for Isolating Structures from Earthquake Attack. Journal of Earthquake Engineering and Structural Dynamics, 3, 297-309. [14] Skinner, R.I., Kelly, J.M. and Heine (1975). Hysteretic Dampers for Earthquake-Resistant Structures. Journal of Earthquake Engineering and Structural Dynamics, 3, 287-296. [15] Skinner, R.I., Robinson, W.H., McVerry, H. and Rahardio, H.(1993). Introduction to Seismic Isolation, Second Edition John Wiley & Sons. [16] Su, L. and Ahmadi, A. (1989). A Comparative Study of Performances of Various Base Isolation Systems, Part I: Shear Beam Structures. Journal of Earthquake Engineering and Structural Dynamics, 18, 11-32. [17] Su, L., Ahmadi, G. and Tadjbakhsh (1989). Comparative Study of Base Isolation Systems. ASCE Journal of Engineering Mechanics, 115, 1076-1992. [18] Vafai, A., Hamidi, M. and Ahmadi, G (2001). Numerical Modelling of MDOF Structures with Sliding Supports Using Rigid-Plastic Link. Journal of Earthquake Engineering and Structural Dynamics, 30, 27-42. @IJAERD-2017, All rights Reserved 620