Dark Matter - III. Workshop Freudenstadt September 30, GRK 1694: Elementarteilchenphysik bei höchster Energie und höchster Präzision

Similar documents
Technical Specifications and Requirements on Direct detection for Dark Matter Searches

The Search for Dark Matter with the XENON Experiment

Direct Search for Dark Matter

Status of Dark Matter Detection Experiments

Direct dark matter search using liquid noble gases

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

Direct Dark Matter Search with Noble Liquids

The XENON1T experiment

Cryogenic Detectors Direct Dark Matter Search. Dark Matter

Direct Dark Matter Searches

Status of DM Direct Detection. Ranny Budnik Weizmann Institute of Science

Shedding Light on Dark Matter from Deep Underground with XENON. Kaixuan Ni (Columbia)

Direct Search for Dark Matter

The Direct Search for Dark Matter

Dark Matter -- Astrophysical Evidences and Terrestrial Searches

Direct detection: results from liquid noble-gas experiments

Direkte Suche nach Dark Matter

Dark Matter Searches. Marijke Haffke University of Zürich

XMASS: a large single-phase liquid-xenon detector

Esperimenti bolometrici al Gran Sasso: CUORE e CRESST

Direct dark matter search using liquid noble gases

A survey of recent dark matter direct detection results

WIMP Dark Matter Search with XENON and DARWIN

Looking for WIMPs A Review

Down-to-earth searches for cosmological dark matter

Dark Matter Detection with XENON100 Accomplishments, Challenges and the Future

Dark Matter Search with XENON

Direct Detection in the next five years: Experimental challenges and Phonon Mediated Detectors

Chapter 12. Dark Matter

Direct Search for Dark Matter

Dark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

DARWIN: dark matter WIMP search with noble liquids

arxiv:astro-ph/ v1 24 Jun 2004

Dark Matter and the XENON Experiment

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

Direct Detection of Dark Matter with LUX

Direct dark matter search with XMASS. K. Abe for the XMASS collaboration

Luca Grandi.

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

Sensitivity and Backgrounds of the LUX Dark Matter Search

Detectors for astroparticle physics

Darkside-50, DarkSide-20k and the Global Collaboration to reach the Neutrino Floor with liquid argon

DARWIN. Marc Schumann. U Freiburg PATRAS 2017 Thessaloniki, May 19,

Measurements of liquid xenon s response to low-energy particle interactions

Recent results and status of the XENON program

LARGE UNDERGROUND XENON

Status of the EDELWEISS Dark Matter search

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

The XMASS experiment. Y. Kishimoto for the XMASS collaboration March 24 th, 2014 Recontres de Moriond, Cosmology

Dark matter search with the SABRE experiment

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Background and sensitivity predictions for XENON1T

Status and Prospects of China JinPing Deep Underground Laboratory (CJPL) and China Dark Matter EXperiment (CDEX)

Background Modeling and Materials Screening for the LUX and LZ Detectors. David Malling Brown University LUX Collaboration AARM Meeting February 2011

Introduction to Class and Dark Matter

Nuclear Recoil Techniques for the Detection of Dark Matter

Latest Results on Direct Detection of Dark Matter WIMPs - CDMS & SuperCDMS

China JinPing underground Laboratory (CJPL) and China Darkmatter Experiment (CDEX) Qian Yue Tsinghua University Mar.24, 2011

DARWIN. Marc Schumann. U Freiburg LAUNCH 17 Heidelberg, September 15,

Results from 730 kg days of the CRESST-II Dark Matter Search

SuperCDMS: Recent Results for low-mass WIMPS

Low Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016

DarkSide-50: performance and results from the first atmospheric argon run

=> Ωmatter >> Ωbaryon

New Physics Results from DarkSide-50. Masayuki Wada Princeton University on behalf of the DarkSide-50 Collaboration Feb

DARK MATTER SEARCH AT BOULBY MINE

Dark Matter, Low-Background Physics

Direct Detection Lecture 2: Current Results

Direct Detection of Dark Matter. Lauren Hsu Fermilab Center for Particle Astrophysics TRISEP Summer School, June 10, 2014

Axion search with Dark Matter detector

DarkSide-20k and the future Liquid Argon Dark Matter program. Giuliana Fiorillo Università degli Studi di Napoli Federico II & INFN Napoli

Latest results of EDELWEISS II

WIMP Direct Detection: an outlook

The Search for Dark Matter. Jim Musser

The next generation dark matter hunter: XENON1T status and perspective

Prospects for WIMP Dark Matter Direct Searches with XENON1T and DARWIN

Recent results from PandaX- II and status of PandaX-4T

DarkSide new results and prospects

Dark Matter. and TPC Technologies

arxiv:astro-ph/ v1 15 Feb 2005

The EDELWEISS DM search Phase II to Phase III

Direct Dark Matter and Axion Detection with CUORE

Overview of Direct Detection Dark Matter Experiments

Cryodetectors, CRESST and Background

DarkSide. Bianca Bottino Università di Genova and INFN Sezione di Genova on behalf of the DarkSide collaboration 1

XENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg

Recent results from the second CDMSlite run and overview of SuperCDMS SNOLAB project

After LUX: The LZ Program. David Malling, Simon Fiorucci Brown University APS DPF Conference August 10, 2011

The Neutron/WIMP Acceptance In XENON100

Background simulations and shielding calculations

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

The XENON Dark Matter Project: Status of the XENON100 Phase. Elena Aprile Columbia University

Precision Measurement Of Nuclear Recoil Ionization Yields For Low Mass Wimp Searches

Darkside and the future Liquid Argon Dark Matter program

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

Direct Dark Matter Searches. General Overview LUX-ZEPLIN Hans Kraus, Oxford

No combined analysis of all experiments available

DARWIN. Marc Schumann Physik Institut, Universität Zürich. Aspera Technology Forum 2010, October 21-22, 2010

PANDA-X A New Detector for Dark Matter Search. Karl Giboni Shanghai Jiao Tong University

Transcription:

Dark Matter - III GRK 1694: Elementarteilchenphysik bei höchster Energie und höchster Präzision Workshop Freudenstadt 2015 September 30, 2015 Guido Drexlin, Institut für Experimentelle Kernphysik KIT University of the State of Baden-Württemberg and National Research Center of the Helmholtz Association www.kit.edu

outline of today s final afternoon lecture Dark Matter 3: direct detection of dark matter - expected WIMP rates: SUSY (M c, s SI,SD) and astrophysics (F, v) - detection methods: 1- & 2- parameter experiments - underground experiments & background - DAMA s annual modulation - bolometers vs. LXe detectors - 2-phase liquid noble gas detectors: XENON100/1T/ DARWIN - conclusion multi-gev multi-gev e- MeV elastic WIMP-nucleus scattering in kev-range e- 2 Sept. 30, 2015 G. Drexlin DM3 MeV

WIMP detection reaction kinematics: input from astrophysics & SUSY R N ASTRO nuclei F s r DM, local SI / SD Nnuclei s SI / SD 0 M ( c ) v SUSY c 0 c 0 s = 0,1 H, h Z WIMP properties: - kinetic energy (v) - local density r DM,local - flux F (from v & r DM,local ) 3 Sept. 30, 2015 G. Drexlin DM3 N nuclei q q WIMP properties: - cross sections scalar s SI / axial s SD - mass M(c 0 )

WIMP number (rel. units) WIMP velocity profile WIMP energies from DM-halo - v ~ 10-3 c - E kin = ½ M c v 2 - M c = 100 GeV E kin < 100 kev E kin «M c isothermal WIMP velocity profile f(v) f (v) dv 2 4v e 3 v 0 d Maxwell-Boltzmann-velocity distribution v 2 / v 2 0 3 v WIMP halo energies nuclear recoil energies E R kinetic energy (kev) 4 Sept. 30, 2015 G. Drexlin DM3

log dn / de WIMP scattering annual modulation modulation of WIMP recoil spectrum - superposition of velocity vectors v S (sun) & v E (earth) period: T = 1.00 year phase: j 0 = June, 2 WIMP wind June, 2 v(t) v0 v E cos(60 ) cos ( t t0) ~2-7% effect galactic plane December v E = 30 km/s December June recoil energy E 5 Sept. 30, 2015 G. Drexlin DM3

WIMP detection reaction kinematics: input from SUSY R N nuclei F s 1 level of partons: q, g DM, local SI / SD Nnuclei s SI / SD 0 M ( c ) c 0 - interaction with quarks, gluons c 0 coupling strength from SUSY model 2 level of nucleons: p, n q, g kinematics within the nucleons is determined by parton distributions (valence- & sea quarks) r v Xe-nucleus nucleon c 0 c 0 3 level of nuclear structure: Ar, Ge, Xe, c 0 - interaction on scale of nucleus (nuclear wave function) - reaction kinematics coherent nuclear recoil 6 Sept. 30, 2015 G. Drexlin DM3

neutralino scattering: scalar interaction scalar interaction: neutralino couples to mass distribution of the nucleus c 0 c 0 s = 0 H, h c 0 c 0 ~ q mechanism: - exchange of a light or a heavy higgs boson H, h - annihilation into squark (q-mixing) ~ q q q s = 0 q - also loop diagrams with (massless) gluons scalar c 0 interaction with a quark (s SI : spin independent) - quark- & gluon functions in nucleon: also heavy quarks contribute - coherent interaction ~ A 2 - s SI dominates the elastic c 0 -cross section in many SUSY models 7 Sept. 30, 2015 G. Drexlin DM3

neutralino scattering: spin-dependent axial-vector interaction: spin of neutralino couples to spin of nucleus c 0 c 0 s = 1 Z 0 J nucl. q q spin-dependent c 0 -interaction (s SD : spin dependent) - spin structure functions: nucleon spin (p,n) from partons - spin matrix elements: nucleons in nucleus ( mean p/n-spin in nucleus) - nuclear shell model: nuclear spin from coupled nucleons in shells 8 Sept. 30, 2015 G. Drexlin DM3

neutralino scattering: spin-dependent s SD ~ s 0 a p S p a n S n 2 J 1 J a p,n : WIMP-proton/neutron couplings (SUSY-model-dependent) J : spin of nucelus via unpaired nucleon (proton / neutron) due to pairing term (Bethe-Weizsäcker) S p,n :expectation value of proton/neutron spin (e.g. 5/2, 1/2) within nulcear shell model p coupling J=0 only J 0 targets are sensitive to spin-dependent WIMP-scattering examples of important target nuclei for s SD (sensitive to a p or a n ): detector type isotope fraction protons neutrons nucl. spin J coupling NaJ (scintillator) 23 Na 11 12 3/2 a p 127 I 53 74 5/2 a p LXe (TPC/scint.) 131 Xe 21.2 % 54 77 3/2 a n 129 Xe 26.4 % 54 75 1/2 a n Ge (bolometer) 73 Ge 7.8 % 32 41 9/2 a n p 9 Sept. 30, 2015 G. Drexlin DM

rate E > E r (events/kg/day) WIMP recoil spectra recoil spectrum for scalar interaction (coherent, form factor) dr de R ds ~ v f (v) dv de R recoil energies of nuclei on kev-scale astrophysics - WIMP-halo model (r CDM, v 0 ) : the larger v 0, the larger the rate - neutralino mass M c detector properties - nuclear target mass M N - nuclear structure (formfaktor F) - very low threshold (few kev) for heay target nuclei (Xe, J) recoil energy E r (kev) 10 Sept. 30, 2015 G. Drexlin DM3

WIMP cross section s [cm 2 ] WIMP plots comparison of results R N nuclei F s r DM, local SI / SD Nnuclei s SI / SD 0 M ( c ) v light WIMPs: nuclear recoil energy below threshold 10-39 10-40 detector threshold E R small (Mc < M N ) heavy WIMPs: W CDM = 0.22 is fixed for large M c the WIMP fluss F decreases, less signal events SUSY region: to cover larger fraction: larger mass & smaller background 10-41 10-42 10-43 10-44 10-45 optimum sensitivity SUSY 10 100 1000 WIMP mass M c (GeV) WIMP flux decreases 11 Sept. 30, 2015 G. Drexlin DM3

WIMP signal & background rate R N nuclei F s r DM, local SI / SD Nnuclei s SI / SD 0 M ( c ) v Gran Sasso shielding source and shielding events/kg/s events/kg/day natural gamma activity 100 10 7 after passive shielding 10 2 cosmic muons at surface of earth 0.1 10 4 expected CDM detection rate < 10-2 12 Sept. 30, 2015 G. Drexlin DM3

muon rate (muons/m 2 /year) underground labs muon rate & depth 10 6 muon rate and shielding depth Campo Imperatore 10 5 10 4 10 3 DUSEL shallow WIPP Soudan LNGS Kamioka Baksan LSM 10 2 10 1 Sudbury DUSEL - Homestake DUSEL Homestake (deep) 5 6 7 8 9 10 3 2 3 4 5 6 7 8 9 10 4 depth (m water equivalent) 13 Sept. 30, 2015 G. Drexlin DM3

direct dark matter experiments Sanford: LUX, LZ SNOlab: PICASSO DEAP CLEAN Soudan: CDMS-II Boulby: ZEPLIN III, Drift Modane: Edelweiss LNGS: XENON 1T CRESST DarkSide50 DAMA/Libra Kamioka: XMASS Soudan: 2000 m.w.e SNOlab: 6000 m.w.e. Sanford: 4800 m.w.e Canfranc: ANAIS Rosebud ArDM Kamioka: 2700 m.w.e 14 Sept. 30, 2015 G. Drexlin DM3

Where are the detectors? 15 Sept. 30, 2015 G. Drexlin VL04

polyethylen extensive shielding example XENON100 Pb- & Cu-shielding in the XENON100 experiment - against gammas ( 235 U, 238 U, 232 Th, 237 Np, 40 K, ), neutrons (µ-induced) PE H 2 O/polyethylen Low-level Pb Cu Pb Cu LXe- TPC Pb Pb PE polyethylen 16 Sept. 30, 2015 G. Drexlin DM3

Radon background radon emanation in underground laboratories is substantial PE Pb a Cu LXe- TPC PE experiments 17 Sept. 30, 2015 G. Drexlin DM3

WIMP detection methods 1 parameter CRESST-I XMASS CLEAN Zeplin I phonons scintillation c 0 c 0 HDMS, DRIFT DAMA/Libra ANAIS NAIAD KIMS ionization 18 Sept. 30, 2015 G. Drexlin DM3

WIMP detection methods 2 parameters scintillation & phonons CRESST-II ROSEBUD CDMS Edelweiss c 0 c 0 XENON LUX WARP ArDM ZEPLIN II,III phonons & ionization ionization & scintillation 19 Sept. 30, 2015 G. Drexlin DM3

DAMA/LIBRA DArk MAtter experiment: NaJ scintillation detector array target: 9 9.7 kg high-purity NaJ crystals (scintillators) E thres = 2 kev ee ( 20 kev recoil energy of 23 Na nucleus ) Read-out: 2 PMT s / crystal, light yield 5-7 p.e. / kev background: sehr geringe NaJ Eigenaktivität, shielding : concrete, paraffin, 15 cm Boliden-Pb, 10 cm Cu, 1-2 events/kev/kg/day NaJ crystals acrylic box N 2 atmosphere DAMA set-up at LNGS 20 Sept. 30, 2015 G. Drexlin DM3

residuals (events per day/kg/kev) DAMA annual modulation 7 years data taking (107 731 kg-days) from January 1995 July 2002 modulation of event rate with T = 1a & expected phase (t 0 = June, 2) - signal directly above hardware threshold in region E = 2-6 kev - no modulation for E = 6-14 kev, statistical significance (CL) = 6.3 s - interpreted by DAMA as evidence for direct WIMP-detection (??) 0.1 t 0 = 152.5 days, T = 1.00 a 0.05 0-0.05-0.1 21 Sept. 30, 2015 G. Drexlin DM3 500 1000 1500 2000 2500 measurement time (days)

XMASS - overview XMASS: strategy: Xenon detector for Weakly Interacting MASSive Particles operated in Kamioka mine in the Japanese alps gradual increase of Xe target mass improved self absorption of background via LXe (10-4 events/kg/kev/day) method: UV-scintillation light in liquid-xenon (LXe) (T = 165 K) at l = 175 nm, but: Rayleigh scattering limits position resolution 100 kg (3 kg fid.) Ø=0.3m 800 kg (100 kg fid.) Ø=0.8m 23 t (10 t fid.) Ø=2.5m 22 Sept. 30, 2015 G. Drexlin DM3

XMASS - results XMASS: strategy: Xenon detector for Weakly Interacting MASSive Particles operated in Kamioka mine in the Japanese alps gradual increase of Xe target mass improved self absorption of background via LXe (10-4 events/kg/kev/day) method: UV-scintillation light in liquid-xenon (LXe) (T = 165 K) at l = 175 nm, but: Rayleigh scattering limits position resolution status: new 2015 results with 832 kg x 16 months exclude DAMA/Libra 23 Sept. 30, 2015 G. Drexlin DM3

DAMA/Libra results excluded DAMA/Libra data (favoured regions) and exclusion limits from Xe-experiments (spin-independent iinteraction) NaJ Xe DAMA/Libra CDMS-II (Si) CRESST-II CoGeNT DAMA/Libra CRESST-II CDMS-II (Si) XENON-100 LUX LUX 10 100 1000 5 6 7 8 9 10 12 WIMP mass M c (GeV) WIMP mass M c (GeV) 24 Sept. 30, 2015 G. Drexlin DM3

2-phase detectors: mass vs. surface bolometers: only few kg, very low threshold large surface, good discrimination noble gases: leading technology for WIMPs deploy multi-ton detectors sensitivity of a dark matter experiment scales with its mass LXe Ge systematics & bg of a dark matter experiment scales with its surface bolometers liquid noble gases 25 Sept. 30, 2015 G. Drexlin DM3

cryogenic bolometers cryo-bolometer at low temperature in mk regime (CRESST, CDMS, ) advantages: - good sensitivity to nuclear recoils (phonons) - very low energy threshold - good energy resolution (~150 ev @ 6 kev) - different target materials (Ge, Si, CaWO 4 ) - combine phonons with ionisation & scintillation: very good separation of gammas & electrons - modular set-up ( scalable & sequentiel extension replace sub-optimal single detectors, new detectors) Ge disadvantages: - extensive mk-cryotechnology (long runs) - limited target mass (~ 30 kg so far) - modular setup ( large inner surface) CaWO 4 26 Sept. 30, 2015 G. Drexlin DM3

Cryo-bolometers measurement principle principle of a cryogenic bolometer (µ-calorimeter): - energy deposition E R of recoil of target nucleus from c 0 -scattering leads to small, but measurable temperature increase DT in absorber - absorber (Ge, Si, CaWO 4 ) with masse M ~ 300-800 g at T 0 = 10-20 mk - thermometer to measure temperature increase DT in absorber - heat bath (weak couplinng) to decrease T(bolometer) to T 0 DT ER V C V important: small specific heat capacity C V of asorber limits mass M of a cryogenic bolometer to ~ 1kg heat bath 27 Sept. 30, 2015 G. Drexlin DM3

cross section s SI (GeV) Bolometers for low-mass region - future bolometer experiments (Super-CDMS, CRESST) will use few kg of detectors (Ge, Si) with low threshold to explore low-mass WIMP region 10-40 10-41 10-42 CoGeNT DAMA/Libra CRESST-II CDMS-II (Si) 10-43 XENON-100 LUX 5 6 7 8 9 10 12 WIMP mass M c (GeV) 28 Sept. 30, 2015 G. Drexlin DM3

cross section s SI (GeV) Bolometers for low-mass region - future bolometer experiments (Super-CDMS, CRESST) will use few kg of detectors (Ge, Si) with low threshold to explore low-mass WIMP region 10-40 10-41 10-42 CoGeNT DAMA/Libra CRESST-II CDMS-II (Si) 10-43 XENON-100 LUX 5 6 7 8 9 10 12 WIMP mass M c (GeV) 29 Sept. 30, 2015 G. Drexlin DM3

LSM Laboratoire Souterrain de Modane Fréjus (2900m) 4800 m.w.e. 4 muons/m 2 /day Italy France entry road tunnel NEMO-III 0nßß Ge gate Modane France Italy Nemo s.b. Höhe Abstand 1228 m 1263 m 1298 m 0 m 6210 m 12 868 m Edelweiss 30 Sept. 30, 2015 G. Drexlin DM3

EDELWEISS Experiment Expérience pour détecter les WIMPs en Site Souterrain French-German experiment at LSM with Ge-/Si-bolometers - 2000-2003: Edelweiss-I M = 1 kg 3 detectors - 2008-2010: Edelweiss-II M = 4 kg 10 detectors 400 g each - 2011-2015: Edelweiss-III M = 32 kg 40 detectors 800 g each cryostat 31 Sept. 30, 2015 G. Drexlin DM3

CDMS Cryogenic Dark Matter Search cryo-bolometers in the Soudan mine in North-Minnesota (2000 m.w.e) absorber: 250 g germanium (Ø = 7.5 cm, h = 1 cm) and 100 g Si-crystals ZIP-detector technology: Z-sensitive Ionisation and Phonon mediated detector signals: ballistic phonons (4 1036 TES: Al and W) use phonon-timing to discriminate against surface events Kryostat: 5 Türme ZIP detector with 4 1036 TES 32 Sept. 30, 2015 G. Drexlin DM3

Liquid noble gas detectors LXe & LAr detectors based on ultra-pure liquid noble gases - operated as 2-phase detectors: liquid & gaseous phase advantages: - large detector volumina (10 kg 100 kg 1 t 50 t ) - particle identification: chage & scintillation, pulse shape challenges: - low threshold, further reduction of background rate Z (A) properties of liquid noble gases as DM-detectors boiling T s [K] at p = 1 bar density at T s [g/cm 3 ] ionisation [e-/kev] scintillation [photons/ kev] scintillation light [l in nm] l-shifter Neon 10 (20) 27.1 1.21 46 7 85 (WLS) Argon 18 (40) 87.3 1.40 42 40 128 (WLS) Xenon 54(129/131) 165.0 3.06 64 46 175 33 Sept. 30, 2015 G. Drexlin DM3

2-phase LXe-experiments principles of LXe 2-phase-detectors: - scintillation light: detection via PMTs in LXe - ionisation signal: drift of electrons in E-field to Xe gas phase gas anode LXe S1 E R PMT Array S2 hn T drift 5 µs / cm electrons hn PMT array in LXe E ext E D signals S1 (prompt) & S2 (delayed): - S1: primary Xe-excitation due to recoiling nucleus (prompt scintillation light) - S2: detection of drifting electrons via extraction to gas phase, there acceleration of e - in strong field electro-luminescence via scattering processes of fast electrons off gas delayed light detection in upper PMT coincidence of S1 and S2: - S1 + S2: particle-id & point of interaction 34 Sept. 30, 2015 G. Drexlin DM3

particle identification (PID) discrimination among WIMP-recoils of Xe-nuclei & electron/gamma-bg particle identification: electron: S2/S1 is large (no quenching) WIMP: S2/S1 is small (less ionisation) energy of Xe-recoil: intensity S1 (primary excitation) position reconstruction: PMTs (x,y), drift time (z) WIMP drift time ratio S2/S1 used for PID MC-simulation of light signales WIMP scattering drifted electrons Kernrückstoß Gamma drift time primary scintillation: S1 secondary scintillation S2 35 Sept. 30, 2015 G. Drexlin DM3

XENON100 experiment XENON-100: at LNGS LXe-detector with 161 kg mass (~99 kg as veto, 62 kg as target) - detector: Ø = 30 cm, h = 30 cm (maximum drift distance for electrons) - 242 PMT for read-out of scintillation- & electro-luminescence- light - factor 100 less background (selection, cleaning, self absorption) factor 10 more mass than predecessor XENON10 LXe cryostat enclosure PMTs 36 Sept. 30, 2015 G. Drexlin DM3

XENON100 experiment XENON-100: measurements at LNGS upper PMT array lower PMT array 37 Sept. 30, 2015 G. Drexlin DM3

log (S2/S1) XENON100 experiment: results Inital results from XENON100: - 224.6 days of data taking: 2323.7 kg days - energy window for WIMPsearch: 6.6 43.3 kev (Xe-recoil energy) 0.4 scintillation S1 (PE) 5 10 15 20 25 30 0.0-2 events observed background expectation N bg = (1.0 ± 0.2) events -0.4-0.8 - s SI < 2.0 10-45 cm 2 at WIMP-mass M c = 55 GeV 5 10 15 20 25 30 35 40 45 50 energy (kev reoil energy ) 38 Sept. 30, 2015 G. Drexlin DM3

Large Underground Xenon (LUX) experiment 2-Phase-Xenon experiment at Sanford Lab: - similar technology as in XENON (S1-S2) H 2 O shielding instrumented as muon veto - detector with 370 kg mass (100 kg fiducial volume ) - expected initial WIMP-sensitivity: s SI = 2 10-46 cm 2 (for R bg = 0.5 events/month/100 kg) thermosiphon watershield sources cryostat 39 Sept. 30, 2015 G. Drexlin DM3

WIMP-nucleon xsec s SI (cm 2 ) WIMP results: actual status 10-40 10-41 DAMA (Na) CDMS (Si) excess: exclusion: DAMA, CRESST, CDMS (Si) LUX, XENON100, CDMS (Ge) 10-42 CRESST 10-43 10-44 LUX (±1s) 10-45 10 20 30 4 50 100 200 300 1000 WIMP mass (GeV) 40 Sept. 30, 2015 G. Drexlin DM3

XENON1T experiment next-generation-xenon experiment at LNGS: - construction period: autumn 2013 autumn 2015 - total (active) LXe mass: 3.3 t (2.0 t), 1 m electron drift, 248 3-inch PMTs - bg-goal: 100 x lower than XENON100 (~ 5 10-2 evts to. -1 d -1 kev -1 ) 41 Sept. 30, 2015 G. Drexlin DM3

DARWIN R&D and design study DARWIN: Dark matter Wimp search in Noble liquids - goal: ultimate DM-experiment: 30-50 tons LXe - reach sensitivity where bg is dominated by neutrinos s SI ~ 10-48 cm 2 Experimental design parameters - TPC diameter > 2 m - electron drift length > 2 m - few x 10³ photosensors Physics goals - WIMP spectroscopy: mass and cross section - others: pp-neutrinos, 0nßß of 136 Xe, axions and ALPs, bosonic SuperWIMPs 42 Sept. 30, 2015 G. Drexlin DM3

s SI (cm 2 ) number of WIMP signals DARWIN R&D and design study DARWIN: Dark matter Wimp search in Noble liquids - goal: ultimate DM-experiment: 30-50 tons LXe - reach sensitivity where bg is dominated by neutrinos 10-43 10-44 WIMP events 10 1 10 0 for M W = 100 GeV s SI = 10-46 cm 2 10-45 10-1 10-46 10-47 10 t Ar 1 t Xe sensitivity 0 1 2 3 4 5 measuring time (years) 43 Sept. 30, 2015 G. Drexlin DM3

WIMP-nucleon xsec s SI (cm 2 ) actual & future WIMP sensitivities 10-40 10-42 10-44 10-46 10-48 10-50 solar neutrinos (MeV) 1 10 10 2 10 3 10 4 WIMP mass (GeV) neutrinos (multi-mev) LXe/LAr n s dominate background 44 Sept. 30, 2015 G. Drexlin DM3

Searching for dark matter a needle in a haystack 45 Sept. 30, 2015 G. Drexlin DM3

Conclusion 46 Sept. 30, 2015 G. Drexlin DM3