Determination of trace anions in concentrated hydrofluoric acid

Similar documents
Dionex IonPac AS28-Fast-4µm column

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

columns IonPac AS17-C Anion Exchange Column

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Determination of Trace Anions in Organic Solvents

anion-exchange column

The determination of trace anions in concentrated phosphoric acid

Determination of trace anions in concentrated glycolic acid

Determination of trace anions in high-nitrate matrices by ion chromatography

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of Trace Cations in Power Plant Waters Containing Morpholine

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

columns IonPac AS18 Anion-Exchange Columns

Determination of Trace Anions in Concentrated Hydrofluoric Acid

The Determination of Trace Anions in Concentrated Phosphoric Acid

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific. Anion-Exchange Column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Determination of urea in ultrapure water by IC-MS/MS

Determination of Trace Anions in Concentrated Glycolic Acid

Inline sample preparation for the determination of anions in sodium hydroxide

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Expanded capabilities in ammonium and amine detection

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

for IonPac AG11-HC IonPac AS11-HC

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Determination of Adsorbable Organic Halogen in Wastewater

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

ProPac WCX-10 Columns

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

columns IonPac AS22 Anion-Exchange Column

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Determination of Methylamine in Drug Products

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

IonPac Trace Cation Concentrator

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

columns IonPac SCS 1 Silica Cation Separator

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Overcoming Challenging Matrices in Ion Chromatography

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Waters. Ion Chromatography

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

IonPac SCS 1 IonPac SCG 1

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of chlorine, bromine, and sulfur in polyethylene materials using combustion IC with a carbonate/bicarbonate eluent

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Advances in Sample Preparation for Accelerated Solvent Extraction

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Determination of Cr(VI) in Water, Waste Water, and Solid Waste Extracts

Product Manual for Dionex IonPac CS12A and CG12A Columns

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Novel Electrodeionization Devices: Applications in Inorganic Analysis

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

Utility of the Charge Detector in Ion Chromatography Applications

Fast methods for the determination of ibuprofen in drug products

Sample Preparation for Ion Chromatography

ION CHROMATOGRAPHY SYSTEM S 150

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Thermo Scientific Dionex eluent suppressors for ion chromatography

Transcription:

APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion chromatography, IC Introduction The determination of trace anions in concentrated hydrofluoric acid has been a difficult analytical challenge. In the past, labor-intensive manual preconcentration methods were required prior to analytical measurements. Typical preconcentration procedures involved evaporation of a specific large volume of sample for 6 to 10 hours on a hot plate before transfer to a volumetric flask and analysis. Also, a class-100 clean room environment has normally been required during sample pretreatment. An improved method for determining trace anions in concentrated hydrofluoric acid has been developed. Trace anions are separated from the high concentration of fluoride by matrix elimination using a Thermo Scientific Dionex IonPac AC10 concentrator column prior to analytical separation. The retained anions of interest are eluted from the Dionex IonPac AC10 concentrator and separated on the moderate capacity Thermo Scientific Dionex IonPac AS10 column. The detection limits (MDL) using this method are 25 to 50 ppb for most trace anions in 5% hydrofluoric acid.

Experimental Equipment* A Thermo Scientific Dionex chromatographic system comprising: Gradient Pump Liquid Chromatography Module, equipped with Model 9010 Rheodyne Injector Conductivity Detector, equipped with 340 kpa (50-psi) back-pressure device Sample Loading Pump * Equivalent or improved results can be achieved using the Thermo Scientific Dionex ICS-5000 + HPIC system. The system configuration is shown in Figure 1. Figure 1. IC system configuration. Conditions Columns: Dionex IonPac AS10 (2 mm) analytical Dionex IonPac AG10 (2 mm) guard Dionex IonPac AC10 (2 mm) concentrator Thermo Scientific Dionex IonPac ATC-1 trap (2 mm), 2 required Deionized water 400 mm Sodium hydroxide 70% v/v Methanol Eluent 1: Eluent 2: Rinsing Reagent: Eluent Flow Rate: 0.25 ml/min Rinsing Flow Rate: 1.0 ml/min Injection Volume: 10 ml Detection: Suppressed conductivity Regenerant: 50 mn Sulfuric acid (needed for AMMS only) Suppressor: Thermo Scientific Dionex AMMS (2 mm) or Thermo Scientific Dionex Anion Self-Regenerating Suppressor (ASRS) (2 mm) Regenerant Flow Rate: 10 ml/min Gradient Program: Time E1 E2 V5 V6 0.0 75 25 0 0 2.5 75 25 1 0 12.0* 75 25 0 1 *Begin sampling Reagents and standards Sodium hydroxide, 30% Suprapur Sulfuric acid, concentrated Methanol, HPLC grade Note: This application note uses Dionex IonPac microbore (2 mm) columns, but the analysis can also be performed using standard 4 mm diameter columns. For more information about microbore analyses, please contact your Thermo Scientific sales representative. Preparation of solutions and reagents 400 mm sodium hydroxide High purity sodium hydroxide, 30% Suprapur sodium hydroxide containing less than 1 mg/l (ppm) of chloride and 5 mg/l (ppm) of sulfate (VWR Scientific), or equivalent is required. Anion contaminants (commonly chloride and sulfate) will have a significant effect on the accuracy, precision, and detection limits of this technique. Degas 960 ml of 18 MW water in a clean 1 L eluent bottle by vacuum degassing while sonicating (15 min). Add 53.4 g (40.2 ml) of 30% Suprapur sodium hydroxide into the solution and mix well. 2

50 mn sulfuric acid (regenerant required for AMMS) Place 3 L of deionized water in a clean 4 L polyethylene container. Add 10.3 g (5.6 ml) of sulfuric acid (conc.) to the solution. Dilute to 4 L with deionized water. This regenerant is not required if an Anion Self-Regenerating Suppressor (ASRS) is used. 70% v/v methanol Place 700 ml of HPLC-grade methanol in a clean 1 L eluent bottle. Add 300 ml of 18 MW water and mix well. Degas before using. Sample preparation Samples of up to 5% hydrofluoric acid (1:10 v/v) can be injected directly. Higher concentrations should be diluted to 5% with high purity water. Discussion of results The determination of trace anions in concentrated acids and bases by ion chromatography has long been an analytical challenge. Ion chromatography has not been applied to sample matrices of extreme ionic strength due to low column capacity and the low ionic strength eluents used in most analytical separations. A several-fold dilution of the concentrated acids is usually required to determine the trace anion contaminants, which typically compromises the detection limits. found in the eluent are a limiting factor in analyzing trace anions. The system blank caused by a high ionic strength sample is illustrated in Figure 2. At equilibrium (A), where the analytical column is in the hydroxide form, the chloride present in sodium hydroxide eluent is also equilibrated in the column. The concentration of chloride in the stationary phase is determined by the distribution coefficient of the anion exchanger for chloride and the level of chloride impurity in the eluent used. Upon injection of concentrated hydrofluoric acid (B), the high concentration (percent level) of fluoride behaves similar to an eluent, eluting blank chloride from the stationary phase along with the analyte chloride (C). Table 1 presents the results of determining trace anions in various concentrations of hydrofluoric acid. Note that the system blank induced by the hydrofluoric acid at various concentrations is not consistent and is sometimes more than twice the analyte concentration. Ultrapure eluents are required to accurately determine anions at mg/l (ppb) concentrations. Suppressed microbore ion chromatography (IC) offers analysts a solution for trace anion determination in concentrated weak acids. Greater suppression capacity can be achieved at the low flow rates of the microbore system. Improved background suppression allows higher capacity analytical columns to be used. As a result, higher capacity columns permit higher concentration of acids to be injected onto the column without overloading, thus improving trace anion detection limits. The matrix effect remains a serious problem in the determination of trace anions in concentrated reagents. The term matrix effect is defined as the interference imposed by the matrix on the analytical separation and detection. In this case, the matrix disrupts the equilibrium concentrations of trace anion contaminants in the ion exchange column causing the elution of those contaminants (system blank) along with the analyte anions. Consequently, the major contaminants commonly Figure 2. Analytical blank caused by high ionic strength sample. Table 1. Spike recovery of chloride in hydrofluoric acid using direct injection (no matrix elimination). % HF Expected Found % Recovery 0.25 0.039 0.039 100 0.50 0.078 0.190 250 1.00 0.156 0.590 380 2.00 0.312 0.880 280 3.13 0.487 1.440 290 4.17 0.649 2.000 310 3

Sample pretreatment techniques prior to analytical measurements have long been used to eliminate the matrix effect. Unfortunately, most anion exchange resins are not effective due to poor selection for anions of the same charge. Another approach is the separation of matrix components from analytes based upon hydrophobicity differences. Weak acids such as hydrofluoric acid, formic acid, propionic acid, and acetic acid have pka s between 3.5 and 4.8. Below this range they remain protonated and uncharged. Using methanol/water as a wash at low ph, most of the weak acid matrix component can be removed prior to analytical measurement. Since high purity grade methanol (trace anion grade) is not commonly available, further purification is required. First, clean the two Dionex IonPac ATC-1 trap columns by pumping 0.5 M sodium hydroxide/50% methanol at 5.0 ml/min for 15 min, followed by rinsing with 200 ml of deionized water. Then, place one of the two Dionex IonPac ATC-1 trap columns between the DQP outlet check valve and valve 6 (BF-2 double stack pneumatic valve in the LCM-3 or LC-20). Place the other Dionex IonPac ATC-1 trap column between the eluent glass bottle (E1) and the AGP. The two Dionex IonPac ATC-1 trap columns will help to reduce trace anion contaminants in the reagents used in this method. The matrix reduction of weakly retained anions is performed by the Dionex IonPac AC10 concentrator column. The Dionex IonPac AC10 concentrator column contains a solvent-compatible, highly crosslinked substrate, layered with Thermo Scientific Dionex MicroBead latex resin (see Figure 3). The sample is injected onto the Dionex IonPac AC10 concentrator column, which has previously been equilibrated with 70% methanol/water. The weak acid matrix component is eluted with methanol, while chloride, sulfate, bromide, and nitrate are retained in the column (phosphate in its acid form is not quantitatively retained under this condition). The retained anions are then eluted from the Dionex IonPac AC10 concentrator column to the Dionex IonPac AS10 analytical column, where they are resolved. Although the matrix component may not be completely eliminated using the Dionex IonPac AC10 concentrator column, it is reduced sufficiently to minimize the matrix effect. Figure 4 shows the comparison of a direct injection versus the column pretreatment technique for a 3.33% hydrofluoric acid matrix. This technique can measure hydrofluoric acid concentrations up to 5% (see Figure 5). The matrix effect is determined by analyzing various concentrations of hydrofluoric acid. The results in Table 2 show that the experimental anion concentrations agree well with the expected values after incorporating the pretreatment technique. Figure 3. Diagram of the Dionex IonPac AC10 MicroBead microporous resin. 4

Figure 5. Determination of trace anions in 5% hydrofluoric acid by IC. Table 2. Spike recovery of chloride, sulfate, bromide and nitrate in 3.33 to 5% hydrofluoric acid. Anion Chloride Sulfate Bromide Nitrate % HF Spike Found 3.33 0.46 0.54 ± 0.01 4.17 0.57 0.57 ± 0.03 5.00 0.69 0.67 ± 0.02 3.33 0.86 0.98 ± 0.03 4.17 1.07 1.01 ± 0.02 5.00 1.29 1.17 ± 0.07 3.33 1.66 1.75 ± 0.03 4.17 2.08 1.89 ± 0.04 5.00 2.50 2.42 ± 0.06 3.33 1.66 1.75 ± 0.02 4.17 2.08 2.10 ± 0.07 5.00 2.50 2.50 ± 0.04 Figure 4. Determination of trace anions in 3.33% hydrofluoric acid by IC. Find out more at thermofisher.com/ic 1994, 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Suprapur is a registered trademark of Merck KGAA. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. AN72535-EN 1017S