Final Report August 2010

Similar documents
BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES

Comparison of V and 10 V DC Voltage References

Interamerican Metrology System (SIM) Regional Metrology Organization (RMO) Capacitance Comparison, Final Report

Final Report. CCEM Comparison of 10 pf Capacitance Standards. Anne-Marie Jeffery Electricity Division NIST May 2000 Revised March 2002

Bureau International des Poids et Mesures, Sèvres, France. *KEBS, Kenya Bureau of Standards P.O. Box , Nairobi, Kenya

Final Report on COOMET Key Comparison of Capacitance at 10 pf (COOMET.EM-K4)

BUREAU INTERNATIONAL DES POIDS ET MESURES. Comparison of Quantum Hall Effect resistance standards of the PTB and the BIPM

by S. Solve +, R. Chayramy +, M. Stock +, D. Vlad*

by A.Tonina*, R.Iuzzolino*, M.Bierzychudek* and M.Real* S. Solve + R. Chayramy + and M. Stock +

Final Report. APMP.EM-K4.1 APMP Key Comparison of Capacitance at 10 pf

metrologia A. Jeffery, R. E. Elmquist, J. Q. Shields, L. H. Lee, M. E. Cage, S. H. Shields and R. F. Dziuba

Ajchara Charoensook, Chaiwat Jassadajin. National Institute of Metrology Thailand. Henry Chen, Brian Ricketts and Leigh Johnson

Mise en pratique for the definition of the ampere and other electric units in the SI

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu

Final Report on COOMET Supplementary Comparison of Capacitance at 100 pf (COOMET.EM-S4)

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Low Frequency Electrical Metrology Programs at NIST

CERTIFICATE OF CALIBRATION

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

The quantised Hall resistance as a resistance standard

792A AC/DC Transfer Standard

For the National Voluntary Laboratory Accreditation Program

NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES

Euramet project 1187 Comparison of Instrument Current Transformers up to 10 ka. Technical protocol (March 2012)

Supplementary Comparison EUROMET.EM-S23 EURAMET PROJECT No 815 FINAL REPORT

AN6783S. IC for long interval timer. ICs for Timer. Overview. Features. Applications. Block Diagram

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Electrical Standards based on quantum effects: Part II. Beat Jeckelmann

Euramet EM-S40. Bilateral Comparison KIM-LIPI / LNE. Final Report

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

For the National Voluntary Laboratory Accreditation Program

MAU200 Series. 1W, High Isolation SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

I. Yang, C. H. Song, Y.-G. Kim & K. S. Gam

LaserTrim Ceramic Chip Capacitor

Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the CMI, Czech Republic and the BIPM in mammography x-rays

CB Series Tantalum Capacitor

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

Essentials of expressing measurement uncertainty

Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

Force Key Comparison EUROMET.M.F-K2. (50 kn and 100 kn) EURAMET Project No 518. Final Report. 14 July Pilot: NPL, United Kingdom

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Electric Double Layer Capacitors Product Specification. To. : DATE : SPECIFICATION WRITTEN CHECKED APPROVED

EUROMET Comparison of a 10 mh Inductance Standard at 1 khz EUROMET.EM-K3. Final Report

Single Phase Parallel AC Circuits

HTS2030SMD Temperature and Relative Humidity Sensor

Development of a Thermal Voltage Converter with Calculable High-Frequency Characteristics

792A AC/DC Transfer Standard

EA-10/17. EA Guidelines on the Calibration of Electromechanical Manometers. Publication Reference

ET4119 Electronic Power Conversion 2011/2012 Solutions 27 January 2012

W_CS-1W5/3W Series. Features. General Description. Functional Diagram. EMC Solution-Recommended Circuit

ALUMINUM ELECTROLYTIC CAPACITORS Capacitor Life

Il nuovo Sistema Internazionale (SI) Le unità elettromagnetiche

Electronics Capacitors

Measurement method for the proficiency testing program

Document No: TR 12 Issue No: 1

Multi Layer Ceramic Capacitor

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

BUREAU INTERNATIONAL DES POIDS ET MESURES

ECE-343 Test 1: Feb 10, :00-8:00pm, Closed Book. Name : SOLUTION

Mass determination of 1 kg silicon spheres for Avogadro project

Uncertainties associated with the use of a sound level meter

TRM Professional Multianode

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

ANNEXE 8. Technical protocols for the interlaboratory comparisons

Chip tantalum capacitors (Fail-safe open structure type)

Supplementary Comparison EURAMET.EM-S19 EURAMET Project No. 688

The Impact of Metallized Electrodes on High Energy Density Pulse Power Capacitors

LaserTrim Ceramic Chip Capacitor

CERTIFICATE OF CALIBRATION

Chip tantalum capacitors (Fail-safe open structure type)

MEASUREMENT OF AC VOLTAGES WITH DIGITAL VOLTMETERS

R SANAS Page 1 of 7

On the axes of Fig. 4.1, carefully sketch a graph to show how the potential difference V across the capacitor varies with time t. Label this graph L.

Introduction to the evaluation of uncertainty

Lab 4 RC Circuits. Name. Partner s Name. I. Introduction/Theory

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

/ NTSSeries NTFSeries Temperature cycle : 1000 cycles

Chip tantalum capacitors

Precision, Low-Power, Low-Dropout, SOT23-3 Voltage References

INSTRUMENT TEST REPORT 679

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-0-U0, WS-UFS-0-U0

Core Technology Group Application Note 3 AN-3

5730A High Performance Multifunction Calibrator. Extended specifications

handbook, 2 columns handbook, halfpage 085 CS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Machine Positioning Uncertainty with Laser Interferometer Feedback

METHODS TO CONFIRM THE MEASUREMENT CAPABILITY OF THE FORCE STANDARD MACHINES AFTER REINSTALLATION

The Journey from Ω Through 19 Orders of Magnitude

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading

Bureau International des Poids et Mesures Comparison of ozone reference standards of the CHMI and the BIPM

Metrology and Environment

Inter-laboratory Comparison of Impedance-Type Hygrometer in the Range from 10 % to 95 % at 5 C to 55 C

Simple calibration for ceramic sensing elements using an ME651

SIM.EM-K2, 1 GΩ SIM.EM-S6, 1 MΩ. RMO COMPARISON FINAL REPORT R. E. Elmquist, D. G. Jarrett, and N. F. Zhang

2160 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 56, NO. 6, DECEMBER /$ IEEE

THE SIMULATION OF RESISTIVE AND CAPACITIVE STRUCTURES

Three Axis Magnetic Field Transducer x-h3x-xx_e3d-2.5khz-1-0.2t

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-4-U0, WS-UFS-4-U0

SMD Aluminum Solid Capacitors with Conductive Polymer

Transcription:

Bilateral Comparison of 100 pf Capacitance Standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the CMI, Czech Republic and the BIPM, January-July 2009 J. Streit** and N. Fletcher* *Bureau International des Poids et Mesures, F-92312 Sèvres Cedex, France **Czech Metrology Institute, Okruzni 31, 638 00 Brno, Czech Republic Introduction Final Report August 2010 This bilateral comparison between the CMI (Czech Republic) and the BIPM was carried out from January to July 2009. One 100 pf travelling standard belonging to the CMI was used. The comparison was carried out with an A-B-A pattern of measurements; the standard was measured first at the CMI for a period of about one month, then for a similar period at the BIPM, and finally again at the CMI. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM- K14.b. Travelling standard The travelling standard was an Andeen-Hagerling model AH11A capacitance module having a nominal value of 100 pf, serial number 01326. The module was hand carried between the two laboratories without an AH1100 frame. During the measurements at the CMI, it was mounted in an AH1100 frame belonging to the CMI (serial number 00055); at the BIPM, the module was mounted in an AH1100 frame belonging to the BIPM (serial number 00104). Previous studies and experience at the BIPM show that AH11A capacitance modules can be moved between different AH1100 frames and reproduce the same capacitance value (after temperature stabilisation) to within at worst a few parts in 10 8 (relative value change). The effect of ambient temperature on standards mounted in an AH1100 frame has also been tested between 20 C to 25 C, and no change in the capacitance values greater than 1 part in 10 8 was detected over this range. Both laboratories measured the travelling standard at an ambient temperature of 23.0 ± 0.5 C. In these conditions, the temperature corrections are negligible. The effects of normal variations in atmospheric pressure and humidity are also negligible. No corrections have therefore been applied for changes in ambient conditions or the change in mounting environment between the two laboratories. The drift and temperature indications of the AH1100 frames were recorded for completeness during all measurement periods, but these are not reported here. A conservative relative standard uncertainty component of 0.058 10-6 (estimated by a rectangular probability distribution covering the range ±0.1 ppm) has been included in the uncertainty of the transfer to cover any differences of the mounting environment in the two laboratories. 1/5

Measurement principle CMI capacitance standard and measurement method Czech Metrology Institute (CMI) use following standards to maintain the value of capacitance and to provide high precision measurements: Set of four fused silica capacitors AH11 of nominal value 100 pf (s. n. 1323, 1324, 1325 and 1326), accommodated in frame AH1100, s. n. 00055. One AH11 of nominal value 10 pf (s. n. 1181), accommodated in a transport box (the power supply circuits are identical with original frame AH1100). The reference standard (AH11, 100 pf, s.n. 1323) was calibrated by BIPM in years 2002, 2003, 2005, and the last calibration was provided 17. 4. 2007. Standards are periodically compared by means of 1 khz ultra-precision capacitance bridge AH2500A, option E, s. n. 000549. The period of measurements is approximately 30 days. The measuring voltage was set to 15 V. The frequency was set to 1 khz. First, the predicted value of reference standard and value measured by AH2500A were compared. Next, the value of the unknown standard was measured by AH2500A and actual value calculated. These measurements were repeated as mentioned above. BIPM capacitance standard and measurement method The BIPM maintains a reference group of four fused silica 10 pf capacitors (one of the NBS type and three of the GR 1408-A type). Since 1999, the mean value of the group has been measured twice a year using a measurement chain linking the 10 pf capacitances to the recommended value of the von Klitzing constant, R K-90 = 25 812.807 Ω. The chain includes a capacitance bridge with ratio 10/1, a multi-frequency quadrature bridge, an ac-dc coaxial resistor with calculable frequency dependence of resistance, and a quantum Hall device operated at 1 Hz. The relative drift rate of the mean value of the reference group is about -3.5 parts in 10 8 per year. The travelling standard was measured in terms of the BIPM 10 pf reference group using a coaxial bridge for two terminal-pairs capacitances with a calibrated 10/1 ratio. The measurements were made using the standard BIPM conditions: nominal frequency of 1592 Hz and nominal voltage of 100 V. The frequency and voltage coefficients of the travelling standard were separately measured against the known properties of a 10 pf reference. Results Table 1 gives the values assigned to the capacitance of standard 01326 on 29/03/2009 by BIPM and CMI, along with the resulting relative difference, Δ, and the corresponding uncertainties. All the uncertainties are given as relative standard uncertainties (1σ estimates). 29/03/2009 is the mean date of the BIPM measurements. The uncertainty on Δ is the combination of the CMI and BIPM uncertainties with the uncertainty of the transfer. Details of all three uncertainty budgets are in the annex. The BIPM value is calculated as the simple mean of 6 measurements over the period 17/03/2009 to 14/04/2009. A linear fit has been made to the CMI before and after measurements, and the CMI value is the value predicted by this fit for the date 29/03/2009. 2/5

Table 1: Final values for standard 01326 CMI BIPM C 01326 on 29/03/2009 99.999 586 pf 99.999 593 pf Relative total uncertainty (1σ est) 0.095 10-6 0.051 10-6 Transfer uncertainty (relative) 0.058 Δ=(C CMI -C BIPM )/C BIPM 0.07 10-6 Combined uncertainty on Δ (1σ est) 0.12 10-6 Figure 1 shows all the individual measurements of both the BIPM and the CMI. The mean value of the BIPM measurements is shown, along with its uncertainty bar (1σ). The linear fit to the CMI before and after measurements is also shown, along with the 1σ uncertainty bar for the predicted value at the time of the BIPM measurements. The result can be summarised in the form of a degree of equivalence, D CMI, between CMI and BIPM for measurements of 100 pf standards at 1 khz and 15 V, with its associated expanded uncertainty, U CMI (k=2, 95% confidence): D CMI = (C CMI C BIPM ) / 100 pf = 0.07 10 6 U CMI = 0.24 10 6-4.00-4.05 CMI BIPM 10 6. (C-100 pf) / 100 pf -4.10-4.15-4.20-4.25 01/01/2009 01/03/2009 01/05/2009 01/07/2009 Date Figure 1: all results for standard 01236, showing CMI measurements and linear fit, plus BIPM measurements with mean and 1σ uncertainty bars. 3/5

Comments The CMI takes its capacitance traceability from the BIPM, via regular calibrations of a 100 pf standard (another AH11a type, serial number 01323). The purpose and interpretation of this bilateral comparison may therefore not be clear. It is true that there is no independent realisation of the farad at the CMI which is being tested. What is being tested however is the ability of the CMI to use the periodic calibrations at the BIPM to provide a continuous calibration service to clients. The last calibration provided by the BIPM was in April 2007, so this comparison is a good test of the ability of the CMI to extrapolate the value of the reference, and of the uncertainty budgets that cover this and the use of the equipment required for capacitance scaling. During the same period as the BIPM measurements for this comparison, a regular calibration of the standard 01323 was carried out; obviously, the results of this calibration were not released to the CMI until after the completion of the present comparison report. The travelling standard here, 01326, has also been previously measured at the BIPM on two occasions (in 2005 and 2007), but any extrapolation of its behaviour based on only two points was not considered reliable enough to compromise the blind nature of the comparison. (The usual procedure of using travelling standards belonging to the BIPM was not used in this case, as the standards were not available at a time that coincided with the possibility for hand transport between the CMI and the BIPM). The before and after measurements at CMI demonstrate an excellent behaviour of the transport standard during this comparison (no doubt due to it being transported by hand between the two laboratories). The different measurement frequencies and voltages in the two laboratories are significant, but the frequency and voltage coefficients of the travelling standard were measured at the BIPM, so the required corrections could be applied with confidence. A conservative uncertainty component has also been included to account for the different mounting environment of the capacitance module at CMI and BIPM, but again this has not been a limiting factor in the overall uncertainty. An identical comparison of 10 pf standards was carried out at the same time as this comparison; the corresponding report is being published simultaneously, and shows very similar results to those presented here. 4/5

Annex: Uncertainty budgets BIPM Uncertainty Budget Component Relative uncertainty/10-9 Values at 1 Hz of 51.6 kω resistors used in quadrature bridge, with 14 respect to R K-90 1 Hz 1541 Hz difference of 51.6 kω resistors 22 Operation of quadrature bridge at 1541 Hz 13 Scaling from 2000 pf capacitors of quadrature bridge to 10 pf reference 15 Extrapolation of the value of the 10 pf reference group 14 Link between unknown and 10 pf reference group 15 Uncertainty on voltage correction (change from 15 V to 10 V) 20 Uncertainty on frequency correction (change from 1592 Hz to 1000 Hz) 26 Stability of standard at BIPM 4 Total 51 All values are standard uncertainties (1σ estimates). CMI Uncertainty Budget Source of Uncertainty Contribution to combined Degrees of Freedom relative standard uncertainty in parts in 10 6 Prediction of reference 0.062 14 standard Repeatability 0.009 8 Noise and Ripples of 0.050 861 reference standard Noise and Ripples of 0.058 723 unknown Temperature stability of 0.005 50 reference standard Temperature stability of 0.005 50 unknown Temp. stability of bridge 0.001 50 Combined relative standard uncertainty 0.095 30 Uncertainty of the Transfer Component Relative uncertainty /10-8 Uncertainty due to mounting and ambient conditions 58 Possible step change of standard on transport negligible Total 58 All values are standard uncertainties (1σ estimates). 5/5