Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Similar documents
Dual readout with tiles for calorimetry.

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

Calibration of large water-cherenkov Detector at the Sierra Negra site of LAGO

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

LHCb Calorimetry Impact

Correction for PMT temperature dependence of the LHCf calorimeters

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

ATLAS Tile Calorimeter Calibration and Monitoring Systems

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Luminosity measurement in ATLAS with Diamond Beam Monitor

Particle Energy Loss in Matter

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Performance of New and Upgraded Detectors for Luminosity and Beam Condition Measurement at CMS

A RICH Photon Detector Module with G-APDs

AIRFLY: Measurement of the Air Fluorescence induced by electrons

Simulation and validation of the ATLAS Tile Calorimeter response

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Non-collision Background Monitoring Using the Semi-Conductor Tracker of ATLAS at LHC

A pattern recognition method for the RICH-based HMPID detector in ALICE

Electronic calibration of the ATLAS LAr calorimeter and commissioning with cosmic muon signals

Luminosity determination in pp collisions using the ATLAS detector at the LHC

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

A Gaussian Fitter for the CESR-c Fast Luminosity Monitor

The Fast Interaction Trigger Upgrade for ALICE

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Radioactivity and Ionizing Radiation

Theory English (Official)

Improved luminosity determination in pp collisions at s = 7 TeV using the ATLAS detector at the LHC

Design of Beam Halo Monitor for CMS

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

The HERA-B ring imaging Cherenkov system } design and performance

Neutron pulse height analysis (R405n)

Atlas results on diffraction

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

Direct WIMP Detection in Double-Phase Xenon TPCs

Particle Energy Loss in Matter

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

DUAL NATURE OF RADIATION AND MATTER

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

Performance of the MCP-PMT for the Belle II TOP counter

Luminosity measurement and Hit Efficiencies in ATLAS

Compton Camera with PositionSensitive Silicon Detectors

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

arxiv: v2 [nucl-ex] 6 Oct 2008

The LHCf experiment at LHC

John Ellison University of California, Riverside. Quarknet 2008 at UCR

Lecture LHC How to measure cross sections...

Particles and Universe: Particle detectors

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

PoS(Vertex 2016)004. ATLAS IBL operational experience

XIth International Conference on Elastic and Diffractive Scattering Château de Blois, France, May 15-20, 2005 arxiv:hep-ex/ v1 31 Oct 2005

ATLAS NOTE October 12, 2009

Response uniformity of a large size RPC

Gas Chamber. (for the HERMES collaboration) Nationaal Instituut voor Kernfysica en Hoge-Energiefysica, NIKHEF

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Scintillation Detector

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

ATLAS Hadronic Calorimeters 101

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7!

Zero degree neutron energy spectra measured by LHCf at s = 13 TeV proton-proton collision

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

GEANT4 simulation of the testbeam set-up for the ALFA detector

Forward detectors at ATLAS

Particles and Universe: Particle detectors

Studies of Hadron Calorimeter

THE ATLAS TRIGGER SYSTEM UPGRADE AND PERFORMANCE IN RUN 2

PoS(PD07)031. General performance of the IceCube detector and the calibration results

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

Detectors for Particle Physics. Lecture 2: Drift detectors Muon detectors MWPC, CSC, RPC, TRT, TPC, Cherenkov

Luminosity measurements and diffractive physics in ATLAS

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

SciBar and future K2K physics. F.Sánchez Universitat Aútonoma de Barcelona Institut de Física d'altes Energies

A Complete Simulation of a Triple-GEM Detector

A gas-filled calorimeter for high intensity beam environments

arxiv: v1 [physics.ins-det] 18 Feb 2009

Muon Telescope at BEO Moussala *

nerix PMT Calibration and Neutron Generator Simulation Haley Pawlow July 31, 2014 Columbia University REU, XENON

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

Tracking at the LHC. Pippa Wells, CERN

Y2 Neutrino Physics (spring term 2017)

MEASURING THE LIFETIME OF THE MUON

EEE4106Z Radiation Interactions & Detection

Radiation (Particle) Detection and Measurement

Validation of Geant4 Physics Models Using Collision Data from the LHC

arxiv: v2 [physics.ins-det] 8 Feb 2013

Performance of the CMS drift tube chambers with cosmic rays

Recent CMS results in the forward region with the CASTOR detector. Sebastian Baur for the CMS Collaboration

Kagamiyama, Higashi-Hiroshima , Japan. Abstract

THE AMS RICH COUNTER

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

Particle Detectors A brief introduction with emphasis on high energy physics applications

Elastic and Total Cross-Section Measurements by TOTEM: Past and Future

Transcription:

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment Camilla Vittori Department of Physics, University of Bologna, Italy Summer Student Program 2014 Supervisor Dott. Marco Bruschi, ATLAS With a view to the Run II of LHC, 44 Hamamatsu R760 PMTs have been calibrated with a 207 Bi source. The working point of each PMT has been xed in order to equalise the PMT gain at a value smaller than 10 5. Studies on the reproducibility and the stability in time of such calibration permitted to reach a 5% accuracy on PMT gain. In addition, an evaluation of the relative gain of 10 modied PMTs has been performed. Introduction LUCID is the main system which measures luminosity in ATLAS. In order to make the detector performances appropriate for the Run II of LHC, which will start in March 2015 at increased centre-of-mass energy and luminosity, LUCID will be subjected to some technology improvements. In particular, the principal sensors (photomultipliers, PMTs) and the readout electronics will change. The new Hamamatsu R760 PMTs will have a quartz window, which has the properties to be radiation resistant and to emit Cherenkov light when passed through by a charged particle. This implies that the quartz window itself can detect particles and can thus be used as a radiator medium. Before the installation, the new PMTs have been equalised to charge particles, that means nding the high voltage 1

1 LUCID 2 at which each PMT has the same gain (< 10 5 to limit the ageing). PMTs have been calibrated with a 207 Bi source, which emits monochromatic electrons. The signal on PMTs is thus due to the Cherenkov light emitted by electrons passing through the quartz window. For every PMT the working point has been determined in the aim of limit their ageing and avoid the saturation at high voltage. Two dierent techniques have been employed: a scan in the voltage range in which the charge peak is around 300 mv ns (due to the experimental setup) and a linear interpolation of the two closest-to-300 mv ns measurements. A study of the systematics associated to the calibration results has been performed, focusing on the reproducibility and on the stability in time. The nal systematic uncertainties have been evaluated to be 5 V on HV measurements which correspond to a 5% accuracy in PMT gain. The same analysis has been made on a sample of 10 modied PMTs with no success, because of the too small quartz window which make the number of electrons hitting the PMTs decrease. Indeed the relative gain of these PMTs was extrapolated from a linear t of the anodic current measurement as a function of a HV scan and compared with Bologna measurements. Some discrepancies, principally due to the dark current, have been found and are going to be studied. 1 LUCID For experiments at particle accelerators, the measurement of the machine luminosity is essential in the cross-section determination of all processes. Luminosity Cherenkov Integrating Detector (LUCID) is the dedicated luminosity monitor of the ATLAS experiment [1]. It measures inelastic proton-proton interactions in the forward direction, providing bunch-by-bunch luminosity with a precision of 2-4% and beam background information. It is composed by two modules placed around the beam-pipe on both forward ends of ATLAS, 17 m far from the interaction point. Each module is formed by 16 photomultipliers (PMTs) and 4 quartz bre bundles which carry the light produced in them to further PMTs, placed far away from the interaction region. PMTs detect Cherenkov light emitted by charge particles passing through their quartz window; the light is carried on 1.5 m long coaxial cables at low noise to the front-end electronics. In every bunch crossing, PMT signals are discriminated by the acquisition system and converted in digital hits if over the threshold (equivalent on a average of 15 photoelectrons); the event is then dened from specic hit congurations. To measure the bunch-per-bunch luminosity,

1.1 Updates 3 LUCID exploits event-algorithms or hit-algorithms [2]; additionally another method has been developed for the Run II which measures the charge produced by PMTs. In fact the produced Cherenkov light, and thus the generated charge, is proportional to the charged particle path in the quartz window, if the energy of the particle is above threshold. 1.1 Updates Starting from March 2015, when the LHC centre-of-mass energy will reach the value of s = 14 TeV, the average number of bunch crossings will increase. This implies a large collected charge in the PMTs due to a greater number of particles passing through the detector, resulting in a faster PMT ageing. The increasing particle uxes originate a strong anodic current which causes the PMT saturation, that is the loss of linearity of the PMT gain as a function of the electron current. In order to be ecient at the new experimental conditions, LUCID will be supported by a new readout electronic system to digitalize PMT signals in the neighbourhood of PMTs themselves. These signals will be used to measure the charge generated every 25 ns (bunch crossing spacing); LUCID will be supported by new algorithms for the luminosity measurement based on the collected charge. In addition, LUCID Hamamatsu R762 PMTs have been replaced by the Hamamatsu R760 PMTs, which are smaller, in order to decrease the acceptance and the anodic current. Consequently, the working tension and the gain will be reduced by an order of magnitude, down to 10 5. The diameter of the new photo-cathodes have been reduced from 15 to 10 mm. For a subset of 10 PMTs, a further acceptance reduction to 5 mm has been achieved through an innovative technique implemented by Hamamatsu, consisting in the introduction of a thin aluminium layer between the window and the photo-cathode (modied PMTs). The reduced size will limit the current collected and thus PMT ageing and signal saturation problems. 2 Photomultiplier Characteristics A photomultiplier is a measure instrument which reveals photons belonging to a spectrum slightly larger than the visible one, and converts them in an electric current. Photons cross the quartz window and hit a photocathode, where they generate photoelectrons by photoelectric eect. Photoelectrons are then accelerated by an electric eld and collected on an electrode. The resulting signal is amplied by a dinode chain separated by a

3 Experimental Setup 4 potential dierence. The main PMT parameters on which our attention has been focused are the gain and the charge collected on the anode. The gain is the ratio between anodic and cathodic currents. Assuming a constant potential dierence between each dinode pair, the gain can be expressed as G = δ n, where δ is the average number of secondary electrons generated after the collision with a dinode and n is the number of dinodes (usually 8 < n < 12). The δ term is a function of the tension applied to the PMT δ = A V β, in which A is a constant, V is the potential dierence between two dinodes and β is a parameter which represents the material of which they are made and their geometry (0.7 < β < 0.8). If V is constant of each dinode pair, the working voltage V can be expressed as V = n V and the gain becomes G P MT = (A V ) n = [A ( V n )β ] n = KV βn = KV α, (1) where all the constant terms have been absorbed in K and α will be indicated in the following as relative gain. The charge gathered on the anode can be expressed as Q = N ph G P MT Q e, (2) in which Q e is the electric charge and N ph is the number of primary electrons. In previous tests on the same PMTs with cosmic rays, this number was around 35, according to the thickness of the quartz window and to the chosen G P MT value. Considering the electron emission by 207 Bi source in all the direction, N ph decreases to 30 (the 85% of its value). Inserting Eq.(1) in the expression for the charge, the dependence of the latter from the working voltage is a function of the relative gain α 3 Experimental Setup Q 1 Q 2 = ( V 1 V 2 ) α. (3) In order to nd the best working point, the PMTs calibration necessitated of an experimental setup composed by: - a Black Box totally isolated from the outside environment. PMTs were placed inside the box in order to be sensitive only to the source and not to other lights.

4 Measurement strategy and results 5 - two Hamamatsu R760 PMTs have been calibrated at the same time. They were located in the black box in the same basement coupled with two 207 Bi sources (Fig.1): one was in the vertical position and the other in the horizontal position. Two dierent electronic channels were connected with them. - two disk-shaped 207 Bi sources have been placed in close contact to the PMTs. 207 Bi emits monochromatic electrons from internal conversion with maximum energies of about 1 MeV and dis-excitation photons with an energy between 0.5 and 2 MeV. In order to increase the number of electrons hitting the PMT with a sucient energy to emit Cherenkov light, the source dimensions where larger than the PMTs (Fig.1). - two Power Supplies in a NIM crate both calibrated which give high voltage to PMTs. - a LUCROD prototype in a VME crate. It is made by two FADCs sampling the analogical signal every 3.125 ns, that corresponds to 8 measurements in every bunchcrossing time (25 ns). LUCROD performs 64 digital samplings, 16 after the trigger, and stores them in a readout schedule (FIFO). The trigger has been setted over the signal itself. For the calibration measurements the logic OR of the two input channels has been required as trigger. Figure 1: PMT basement and connection to the source in the black box (right) and the diskshaped 207 Bi source (left). 4 Measurement strategy and results The goal of this measurement is to nd a working voltage for all the PMTs that will be installed in LUCID II at low gain. The two main requirements are:

4 Measurement strategy and results 6 ˆ PMT gain less than 10 5, in order to reduce the ageing; ˆ signal induced by the 207 Bi source well separated from the electronic noise. The expression for the collected charge is Q(mV ns) = 10 12 50(Ω) Q e N ph G P MT G F ADC. (4) With the chosen LUCROD settings G F ADC = 13.92, G P MT = 0.89 10 5 is the gain corresponding to a charge of 300 mv ns. It allows to a single-track amplitude in the PMT of less than 4 mv; this implies that at least 25 tracks are needed to reach the saturation voltage. For each PMT ve 207 Bi signal measurements have been taken with a 10 V spread, starting from the high voltage value at which the charge distribution peaked around 300 mv ns. For each HV value, FADC thresholds have been setted in order to reach the best signal from the source in both channels. Fig.2 shows the measured signal and the integrated charge distributions; Fig.3 illustrates the amplitude of the signal. In particular the request of the logic OR of the two channels implies the presence of the distributions of both PMTs: in Fig.3 the pedestal is due to the second PMT in the box, while the gaussian curve indicates the amplitude of the PMT in exam. Finally there is another eect caused by the electrons belonging to the source and emitting photons without passing through the quartz window. The interesting signal is due to electrons losing their energy inside the PMT window, easily discriminable from the other eects regulating the FADC threshold. Figure 2: Measured signal (right) and charge (left) at 670 V for the EA3393 PMT. The HV working point has been obtained through two dierent techniques. First, it was derived according to Eq.(3): the charge measurements Q i and the relative gain α have

4.1 Systematics 7 Figure 3: Amplitude distribution for 3393 PMT at 640 V. Some features can be observed: the pedestal trigger from the second PMT in the box (red), the FADC threshold (black), the 207 Bi signal outside (green) and inside (blue) the PMT quartz window. been employed to evaluate the voltage corresponding to a 300 mv ns charge. Subsequently in the charge distribution as a function of the HV, the two closest-to-300 mv ns have been linearly interpolated; the HV working point is again the tension value referring to the peak charge (see Fig.4). Finally, a comparison of the two methods has been made. The results of the calibration measurements are summarized in Tab.1, where the values of the HV working point are listed for each PMT. In addition, after inserting charge and amplitude measurements in Eq.(3), a check on the relative gain has been made, in order to verify the previous evaluation with cosmic rays: the obtained value α = 0.08 is compatible with prediction for each PMT. 4.1 Systematics In order to verify the stability on time of the results, EA3375 and EA3388 PMTs charge measurements have been repeated 30 min and 10 h after they switched on (see Fig.5). Fixing their tension to the HV working voltage, the t on charge distribution should give a charge value around 300 mv ns; the obtained charge values are

4.1 Systematics 8 Table 1: Relative gain and HV working point calibration results for each PMT for LUCID II PMT α HV (V) PMT α HV (V) EA3362 7.94 ± 0.08 672 +2 EA3395 8.38 ± 0.08 645 +1 EA3363 8.11 ± 0.08 641 +2 EA3396 7.98 ± 0.08 654 +3 EA3365 8.10 ± 0.08 629 +2 EA3397 8.34 ± 0.08 652 +1 EA3366 8.01 ± 0.08 637 +2 EA3398 8.14 ± 0.08 637 +1 EA3367 8.31 ± 0.08 645 +2 EA3399 8.30 ± 0.08 638 +2 EA3368 8.34 ± 0.08 644 +1 EA3400 8.13 ± 0.08 645 +2 EA3373 8.20 ± 0.08 641 +1 EA3401 8.15 ± 0.08 667 +3 EA3375 8.18 ± 0.08 614 +1 EA3402 8.21 ± 0.08 675 +4 EA3376 8.31 ± 0.08 663 +1 EA3403 8.40 ± 0.08 637 + EA3378 7.76 ± 0.08 648 +3 EA3404 8.28 ± 0.08 634 +2 EA3379 8.19 ± 0.08 649 +2 EA3405 8.13 ± 0.08 642 +2 EA3383 8.22 ± 0.08 634 +1 EA3406 8.22 ± 0.08 645 +1 EA3384 8.26 ± 0.08 654 +1 EA3407 7.83 ± 0.08 636 +3 EA3385 8.14 ± 0.08 646 +3 EA3408 8.27 ± 0.08 638 +1 EA3386 8.37 ± 0.08 643 +2 EA3419 8.19 ± 0.08 620 +2 EA3387 8.17 ± 0.08 594 +2 EA3410 8.21 ± 0.08 617 +1 EA3388 8.37 ± 0.08 610 +1 EA3411 8.13 ± 0.08 642 +2 EA3390 8.14 ± 0.08 614 +1 EA3412 8.25 ± 0.08 654 +1 EA3391 8.26 ± 0.08 651 +3 EA3414 8.10 ± 0.08 621 +1 EA3392 8.08 ± 0.08 633 +1 EA3415 8.33 ± 0.08 623 +2 EA3393 8.17 ± 0.08 653 +2 EA3416 8.34 ± 0.08 612 +1 EA3394 8.08 ± 0.08 668 +1 EA3420 8.17 ± 0.08 713 +1 EA3375 Q 30 min = 287.9 ± 1.0 mv ns Q 10 h = 287.9 ± 1.1 mv ns EA3388 Q 30 min = 312.7 ± 1.2 mv ns Q 10 h = 310.3 ± 1.3 mv ns in agreement with expectations. Fitting the PMT charge peak at the working voltage, a charge measurement with a maximum spread of 15 mv ns from the expected value has been obtained. Therefore 15 mv ns for 300 mv ns charge imply a gain accuracy of 5%. In order to study the dependence of the measurement from the coupling with the source, HV scans have been repeated for EA3401, EA3402, EA3405, EA3406 and EA3414 PMTs: as shown in Tab.2, the nal systematic uncertainties on the working voltage is about 5

4.2 Modied PMTs 9 Figure 4: Linear interpolation technique for the EA3392 PMT. V, which corresponds to a 5% level of systematic error on PMT gain, in agreement with the previous check. Table 2: Comparison between HV working point evaluated in two dierent scan for some PMTs. PMT HV I scan (V) HV II scan (V) EA3401 663 667 EA3402 670 675 EA3405 643 642 EA3406 649 645 EA3414 613 621 4.2 Modied PMTs The equalisation of the modied PMTs with the 207 Bi source has not been possible. In fact because of their smaller window, the number of electrons passing through the quartz is not enough to produce an easily recognisable anodic current and thus a visible peak in the amplitude and charge distributions, as illustrated in Fig.6. Due to the impossibility to nd their HV working point, a dierent study on the determination of the relative gain through the anodic current was performed. The current in fact is linearly proportional to the gain and thus to the voltage (I G V α ): this means that from a linear t of the I measurements as a function of HV, the relative gain can be inferred, as shown in Fig.7. The voltage scan has been performed in a range

4.2 Modied PMTs 10 Figure 5: Charge distribution repeated 30 min (left) and 10 h (right) after the switching on of the EA3375 (top) and EA3388 (bottom) PMTs. between 500 V and 800 V in steps of 50 V, both increasing and decreasing the tension. In Tab.3 the relative gain for each modied PMT is compared with the same measurement taken in Bologna, with a dierent setup (studies ongoing). Table 3: PMT α α Bo PMT α α Bo XN1839 8.58 ± 0.08 / XN1849 8.30 ± 0.08 / XN1843 8.30 ± 0.08 8.53 ± 0.08 XN1851 8.33 ± 0.08 8.49 ± 0.08 XN1844 8.53 ± 0.08 / XN1852 8.12 ± 0.08 8.26 ± 0.08 XN1846 8.50 ± 0.08 / XN1853 8.37 ± 0.08 8.75 ± 0.08 XN1848 8.36 ± 0.08 7.78 ± 0.08 XN1854 8.30 ± 0.08 /

5 Conclusions 11 Figure 6: Amplitude (left) and charge (right) distributions of XN1843 modied PMT. Figure 7: Linear t of anodic current distribution as a function of the increasing HV for XN1852 modied PMT. 5 Conclusions With a view to the LHC Run II, some LUCID characteristics have been improved in order to be ecient for the new experimental conditions. In particular the new Hamamatsu R760 PMTs will be installed on LUCID II coupled with a new electronic system. 44 PMTs have been equalised to charged tracks: the HV working point has been xed in order to well separate signal from noise and to equalise the PMT gain at a value smaller than 10 5 to reduce their ageing. The calibration measurements have been obtained using a 207 Bi source. Studies of the reproducibility and the stability in time have been performed

REFERENCES 12 reaching a nal systematic uncertainty of 5 V on HV measurements which corresponds to a 5% accuracy on PMT gain. In conclusion, the relative gain of 10 modied PMTs have been evaluated through anodic current measurements with a HV scan and compared with Bologna previous measurements. References [1] ATLAS Collaboration, The ATLAS Experiment at the CERN Large Hadron Collider, JINST 3 S08003, 2008. [2] ATLAS Collaboration, Updated Luminosity Determination in pp collision at 7 TeV using the ATLAS Detector, ATLAS-CONF-2011-011.