HORIBA SPECTROFLUOROMETER CALIBRATION

Similar documents
Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Jasco V-670 absorption spectrometer

How Do We Get Light from Matter: The Origin of Emission

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Photoluminescence Spectrometer (FLS980)

GAMMA RAY SPECTROSCOPY

Scintillation Detector

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

Experiment P30: Centripetal Force on a Pendulum (Force Sensor, Photogate)

Fluorescence Spectrophotometry

Uniformly Accelerated Motion

University of Minnesota Nano Center Standard Operating Procedure

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

THERMAL RADIATION. The electromagnetic radiation emitted by a hot tungsten filament will be studied.

FMSPILL (Fluorescence Spillover Correction) Version 1.2

PhET Light Emission and Lasers (27 points available x 2/3 = 18 points max score)

Protocol for Use of BCMP Jasco J-815 Circular Dichroism Spectropolarimeter

GLD Skill Booster #4:

Quality Measures Green Light Report Online Management Tool. Self Guided Tutorial

Hooke s Law. Equipment. Introduction and Theory

Vibrations of Carbon Dioxide and Carbon Disulfide

Computational Chemistry Lab Module: Conformational Analysis of Alkanes

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Cerno Application Note Extending the Limits of Mass Spectrometry

Zetasizer Nano-ZS User Instructions

Zeeman Effect Physics 481

Kinetics of Crystal Violet Bleaching

Titration of Acids and Bases

Lab Exploration #4: Solar Radiation & Temperature Part II: A More Complex Computer Model

Experiment 10. Zeeman Effect. Introduction. Zeeman Effect Physics 244

Mimir NIR Spectroscopy Data Processing Cookbook V2.0 DPC

ON SITE SYSTEMS Chemical Safety Assistant

Physics 476LW Advanced Physics Laboratory Atomic Spectroscopy

EMISSION SPECTROSCOPY

Applications of Newton's Laws

Two problems to be solved. Example Use of SITATION. Here is the main menu. First step. Now. To load the data.

Z -LYTE Assay Setup Guide on the BMG LABTECH CLARIOstar Reader

iworx Sample Lab Experiment GB-2: Membrane Permeability

General Physics I Lab. M1 The Atwood Machine

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

THE ATOMIC SPECTRUM OF HYDROGEN

Measuring ph with Smart Cuvettes

Impulse, Momentum, and Energy

Extending Transducer Calibration Range by Extrapolation

How to Perform a Site Based Plant Search

Developing a Scientific Theory

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Electric Fields and Equipotentials

Electrons in Atoms. Section 5.1 Light and Quantized Energy Section 5.2 Quantum Theory and the Atom Section 5.3 Electron Configuration

Atomic Emission and Molecular Absorption Spectra

Software BioScout-Calibrator June 2013

Magnetic Fields. Goals. Introduction. Mapping magnetic fields with iron filings

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

Activity P27: Speed of Sound in Air (Sound Sensor)

Boyle s Law and Charles Law Activity

Experiment 3: The Rovibrational Spectrum of HCl (was Experiment 4 in the syllabus, but the original Experiment 3 was canceled)

Coulomb s Law Mini-Lab

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Miniature Fiber Optic Spectrometry StellarNet Tutorial

Using a GIS to Calculate Area of Occupancy. Part 1: Creating a Shapefile Grid

Modeling the UV-Vis Absorption of a Series of Dyes CH342L: Spectroscopy February 15, 2016

Ocean Optics Educational Spectrometers. Getting Started Manual

Student Exploration: Bohr Model: Introduction

Student Exploration: Bohr Model of Hydrogen

Determining C-H Connectivity: ghmqc and ghmbc (VnmrJ-2.2D Version: For use with the new Software)

CRL MASS SPECTROMETRY FACILITY USER MANUAL LCT CLASSIC A & B

CHEMISTRY SEMESTER ONE

Theoretical Background Neglecting air resistance, an object falls a distance proportional to the square of the. d t 2

Experiment 7: Spectrum of the Hydrogen Atom

Emission and Absorption Spectroscopy Background

Lecture 2. Estimating Single Population Parameters 8-1

Tutorial 2. SSMA Cee in Compression: 600S F y = 50ksi Objective. A the end of the tutorial you should be able to

User Manual Chirascan CS/ORD

The Flow of Energy Out of the Sun

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

COLOR MAGNITUDE DIAGRAMS

Free Fall. v gt (Eq. 4) Goals and Introduction

Spectrometer User s Guide

Winmostar tutorial LAMMPS Melting point V X-Ability Co,. Ltd. 2017/8/17

Chemical Kinetics: Integrated Rate Laws. ** updated Procedure for Spec 200 use **

Determining the Concentration of a Solution: Beer s Law

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

( J s)( m/s)

Predictor Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

1. Double-click the ArcMap icon on your computer s desktop. 2. When the ArcMap start-up dialog box appears, click An existing map and click OK.

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

CHEMISTRY 170. Radioisotopes

SFT3000S Measurement of Sn-Cu Coating

A Guide to Recording Fluorescence Quantum Yields

Compute Redshifts of Quasars Using SPLAT-VO

Physics Labs with Computers, Vol. 1 P05: Free Fall (Picket Fence) A

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Experiment 0 ~ Introduction to Statistics and Excel Tutorial. Introduction to Statistics, Error and Measurement

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Using the Budget Features in Quicken 2008

for a Weak Acid 1-ring stand stir plate and stir bar ph Probe ml burette 1-50 ml and ml beaker Drop counter ph 7.00 buffer 0.

Name Class Date. Activity P21: Kinetic Friction (Photogate/Pulley System)

Transcription:

HORIBA SPECTROFLUOROMETER CALIBRATION Purpose of this Instrument: Essential tool for characterizing the relationship between absorbed and emitted photos at specified wavelengths. Location: 381 Chemistry Research laboratory building Primary Staff Contact: Huiyuan Li (304) 906-5368 (M) (304) 293-0747(O) Office: CRL 381 Huiyuan.Li@mail.wvu.edu Secondary Staff Contact: Dr. Marcela Redigolo (304) 680-3007 (M) (304) 293-9683 (O) Office: ESB G75D Marcela.Redigolo@mail.wvu.edu The Shared Research Facilities are operated for the benefit of all researchers. If you encounter any problems with this piece of equipment, please contact the staff member listed above immediately. There is never a penalty for asking questions. If the equipment is not behaving exactly the way it should, contact a staff member. Figure 1 Horiba Fluorolog-3 spectrofluorometer at 381 CRL

1. Start instrument as described in SOP. 2. Click Measurement. Then choose SPECTRA. Exitation calibration 3. Choose EXCITATION. Figure 2 Measure type window. Figure 3 Choose Excitation. 4. Use all default parameter. Excitation 200-600 nm, Emission 350 nm. Then hit RUN. 1

You will see real time data acquisition window. Figure 4 Use default settings for excitation measurement. 5. Then you will see data window. Figure 5 Real time spectra window. 2

Figure 6 Data file window. 6. Double click on the data window. Figure 7 Data file analysis window. 3

7. You will activate the analytical tool. Place Cursor TOOL on the tip of the peak. You could read the wavelength and intensity of the peak. Figure 8 Data analysis window 8. The peak should be at 467. If this peak is not at 467 nm, you should calibrate. Click on the previous experiment button. Then click RTC (real time control). 4

Figure 9 Run real time control (RTC) 9. Click on the Monos. You will see this window (Figure 10). Choose Excitation tab. Tap the number you read from your last excitation reading. Write the number from your last excitation reading Figure 10 Calibrate excitation 5

Here we write 467 Figure 11 Calibrate excitation Then hit on calibration excitation 1. Write the number it should be. It should be 467. Then hit ok. Then hit CANCEL from the RTC control window. the number that you read 467 nm, the number should be. Figure 12 Calibrate excitation 6

10. Hit the Previous Experiment button. Run again with default settings. CRL Horiba Spectrofluorometer 15 Jan 2016 Figure 13 Run PREVIOUS experiment. 11. Confirm the excitation is at 467 nm. The calibration is done. Figure 14 Check the excitation wavelength. 7

Emission calibration 1. Choose emission. Place MilliQ water sample in sample compartment, and close lid. Figure 15 Check Emission 2. Use default settings for the Emission calibration. Hit RUN. 3. You will see emission spectra. Figure 16 Emission set up window. Use default settings. 8

Figure 17 Emission spectra window 4. Put the cursor on the top of the peak. The emission should be 397 nm. If the number is not 397 nm, the emission should be calibrated. Figure 18 Check emission maximum 5. Click on PREVIOUS experiment button. Click RTC button. 9

Figure 19 Run RTC 6. Write the number what you have seen in the emission, and write 397 nm in the calibration emission window. 7. Run PREVIOUS experiment again with default settings and then double check the emission wavelength. Figure 20 Emission analysis window. Double check the emission is at 397 nm. 10