Tri-n-propyltin Chloride Mixture

Similar documents
Metolachlor ESA Sodium Salt Standard

USP Class 1 Residual Solvent Mixture

Certified BTEX in Unleaded Gas Composite

HPLC Reverse Phase Test Mix #1

Delta-9-THC Standard. Catalog # Lot # A082745

Aldehydes/Ketones DNPH Standard

Certified Reference Material - Certificate of Analysis

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Certified Reference Material - Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

STANDARD OPERATING PROCEDURES

Certificate of Analysis

Sulfotepp impurities in Chlorpyrifos EC formulations

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

ANALYSIS CERTIFICATE OF

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Certificate of analysis Certified reference material code: CRM-00-GTX1&4

ASPIRIN (ACETYLSALICYLIC ACID) CERTIFIED REFERENCE MATERIAL

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Certificate of analysis Certified reference material code: CRM-00-NEO

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Appendix II- Bioanalytical Method Development and Validation

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

(RS)-2-(4-isobutyrylphenyl)propanoic acid Ibuprofen Impurity J

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3165 Lot Number: EDTA NIST SRM 928 Lot Number: 928

BUTYL ALCOHOL in urine by GC-FID Code GC05510

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

CERTIFICATE OF. Single Analyte Custom Grade Solution. ICP Assay NIST SRM 3120a Lot Number: Calculated NIST SRM Lot Number: See Sec. 4.

TECHNICAL BRODIFACOUM

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Quantos GraviPrep. Bye Bye, ml Hello, Quantos

The Uncertainty of Reference Standards

Study of Residual Solvents in Various Matrices by Static Headspace

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3103a Lot Number:

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) EDTA NIST SRM 928 Lot Number: 928

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

Technical Procedure for General Laboratory Equipment

ph Calibration Buffers

HIPPURIC ACID and o-m-p- METHYLHIPPURIC ACIDS IN URINE BY UV CODE Z06010

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3122 Lot Number:

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3162a Lot Number:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number: Cr3

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

PHENYLEPHRINE HYDROCHLORIDE CERTIFIED REFERENCE MATERIAL

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Mouse IgE ELISA. Cat. No. KT-401 K-ASSAY. For the quantitative determination of IgE in mouse biological samples. For Research Use Only.

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

Quality? Who Decides? Mitzi M. Rettinger Vice President, Sales & Marketing Cerilliant Corporation Round Rock, TX

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Single Analyte Custom Grade Solution. 999 ± 3 µg/ml g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number:

Hydrogen as a Carrier Gas in the Analysis of Polar/Non-Polar Compounds Using the Polyarc System. Application Note. Author. Introduction.

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

Pesticide Standards. Sadat Nawaz. Pesticides Residues Analyst CSL, York, UK

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

Certificate of Analysis

Single Analyte Mass Spec Solution ± 0.60 µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Certificate of Analysis

Consumables Guide for the Cannabis Testing Lab

IgE (Rat) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

CALIBRATION CERTIFICATE # 503

IgA ELISA. For the quantitative determination of IgA in human serum and plasma. For Research Use Only. Not for Use in Diagnostic Procedures.

Environmental Health. Solution Basics

Human Alpha 1-Anti- Chymotrypsin ELISA

IgD ELISA. For the quantitative determination of IgD in Human serum and plasma. Please See Appendix A for Reference Serum Information

Transcription:

Analytical Reference Materials Tri-n-propyltin Chloride Mixture Catalog # 31476 Lot # A0107262 110 Benner Circle Bellefonte, PA 16823-8812 1-814-353-1300 1-800-356-1168 www.restek.com FOR LABORATORY USE ONLY. READ MSDS PRIOR TO USE. RAW MATERIAL TEST INFORMATION AVAILABLE UPON REQUEST MANUFACTURED UNDER RESTEK'S ISO 9001 REGISTERED QUALITY SYSTEM Page 1 of 6

110 Benner Circle Bellefonte, PA 16823-8812 Tel: (800)356-1688 Fax: (814)353-1309 Certificate of Analysis www.restek.com FOR LABORATORY USE ONLY-READ SDS PRIOR TO USE. This Reference Material is intended for Laboratory Use Only as a standard for the qualitative and/or quantitative determination of the analyte(s) listed. Catalog No. : 31476 Lot No.: A0107262 Description : Tri-n-propyltin Chloride Mixture Container Size : Tri-n-Propyltin Chloride Std 2000µg/mL, Methylene Chloride, 1mL/ampul 2 ml > 1 ml Pkg Amt: Expiration Date : November 30, 2017 Storage: 10 C or colder Elution Order Compound CAS # Percent Purity Grav. Conc. (weight/volume) Expanded Uncertainty (95% C.L.; K=2) 1 Tri-n-propyltin chloride 2279-76-7 99% 2,016.0 µg/ml +/- 18.7477 µg/ml Solvent: Methylene Chloride 75-09-2 99% Specific Reference Material Notes: Derivatization in the sample preparation of this standard is required for internal acceptance testing as a result the acceptance criteria is ±15%. Page 2 of 6

Column: 30m x 0.25mm x 0.25µm Rtx-5 (cat.#10223) Carrier Gas: hydrogen-constant pressure 10 psi. Temp. Program: 75 C (hold 1 min.) to 330 C @ 20 C/min. (hold 10 min.) Inj. Temp: 250 C Det. Temp: 330 C Det. Type: FID This chromatogram represents a general set of testing conditions chosen for product acceptance. For optimal results in your lab, conditions should be adjusted for your specific instrument, method, and application. Date Mixed: 17-Nov-2014 Balance: B345965662 Date Passed: 19-Nov-2014 Manufactured under Restek's ISO 9001:2008 Registered Quality System Certificate #FM 80397 Page 3 of 6

General Reference Material Notes Expiration Notes: Expiration date valid for unopened ampul stored in compliance with the recommended conditions. Uncertainty, concentration, and expiration of the RM are based on the unopened product being stored according to the recommended condition found in the storage field. Purity Notes: Purity and/or chemical identity are determined by one or more of the following techniques: GC/FID, HPLC, GC/µECD, GC/MS, LC/MS, RI, and/or melting point. Compounds with a listed purity of less than 99% have been weight corrected to compensate for impurities and/or salts. A correction factor is used to calculate the amount of compound necessary to achieve the desired concentration of the parent compound in solution. Purity of isomeric compounds is reported as the sum of the isomers. Purity values are rounded to the nearest whole number. Uncertainty Value Notes: Uncertainties are determined using data from balances and glassware, raw material purity, and, when significant, equipment tolerances or calibration results. Manufacturing Notes: Concentration is based upon gravimetric preparation using either a balance whose calibration has been verified daily using NIST traceable weights, and/or dilutions with Class A glassware. Handling Notes: Samples should be transferred into deactivated vials for handling and storage. Restek supplies deactivated vials along with most standards packed in 2 ml ampules. Due to space constraints, Restek does not supply vials for larger volume ampules. Restek sells DMDCS for the purpose of glassware deactivation as catalog number 31861, which includes complete instructions. Restek will also deactivate larger volume vials from our inventory as a custom ordered item. Contact your Restek sales or customer service representative for details. If any undissolved material is visible inside the ampul, sonicate the unopened ampul until the material is completely dissolved. Page 4 of 6

Catalog #: 31476 Target: 2000 ug/ml Description: Tri-n-propyltin Chloride Mixture Solvent: Methylene Chloride Solvent Lot: 146352 Chemical Standard Batch Sheet Lot #:A0107262 Final Volume: 25 ml Made by: Brandon Reish Date: 11/17/2014 2:28:08PM Tested by: Jodi Breon Pass Date: 11/18/2014 5:19:09PM By: Jennifer Pollino Date: 11/19/2014 6:15:40A Packaged by: Brandon Reish / Brandon Reish Date: 11/17/2014 2:48:39P No. Units: 16 Pkg Size: 1 ml Balance Used: BEDEARMBALPC4 XPE504 Serial #: B345965662 Compound CAS Tri-n-propyltin chloride 2279-76-7 Storage Target Location Lot # Purity Conc(ug/mL) Target Actual Calc Conc(ug/mL) Desiccator 26110100 0.99 2,000.00 50.00 mg 50.40 mg 2,016.0 Page 5 of 6

QA Report: Tri-n-propyltin Chloride Mixture (Cat.#31476) Runs of Lot # A088882 Runs of Lot # A0107262 COMPONENT Run #1 Run #2 Run #3 AVG STD DEV % RSD Run #1 Run #2 Run #3 AVG STD DEV % RSD %D MEAN P/F Tri-n-propyltin chloride 473574 470665 465889 470043 3880 0.83 434149 429859 432759 432256 2189 0.51 8.04 PASS Page 6 of 6 11/19/2014 6:17:10 AM 1/1-1