Available online at ScienceDirect. Reynaldo Zoro*

Similar documents
Application of Lightning Location System Data for Designing the External Lightning Protection System

66kV & 220kV Substation Protection From Lightning by Fixed Angle, Rolling Sphere and Early Streamer Method

DIRECT STROKE LIGHTNING PROTECTION DESIGN

This case study also provides recommendations for future lightning protection design for existing (brownfield) substation.

Proposed revisions to IEEE Standard 998 (1996) Guide for Direct Lightning Stroke Shielding of Substations

Assessment of the interception efficiency of CVM-based lightning protection systems

Lightning Effect on Scaled Protected and Un-Protected Building Structures and the Air Terminal Bypasses

APL 2017 The 10 th Asia Pacific International Conference on Lightning May 16-19, 2017, Krabi Resort, Krabi, Thailand

Electricity Review completed.notebook. June 13, 2013

A Roadmap for Evaluation of Lightning Elimination Technologies

Lightning in Florida. Henry E. Fuelberg Department of Meteorology Florida State University

INTRODUCING THE HALO PDCE LIGHTNING SUPPRESSOR. by EMP Solutions, Inc.

EFFECTIVENESS OF WORLDWIDE EXISTING ESE LIGHTNING PROTECTION SYSTEMS MANUFACTURED IN EUROPE

Lightning. Electricity and Charge. Primary types of lightning. Primary types of lightning. How do clouds gain a charge?

Lightning Safety. MANSCEN Safety Office (573)

Lightning Phenomenon, Effects and Protection of Structures from Lightning

3 Severe Weather. Critical Thinking

Identification of engineering bedrock in Jakarta by using array observations of microtremors

EPRI Lightning Protection Design Workstation

Are you prepared for a lightning strike?

Evaluation the impact tilt angle on the sun collectors

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION

IN VEHICLES: Do not try to outrun a tornado. Abandon your vehicle and hide in a nearby ditch or depression and cover your head.

Electricity. What is electricity?

THE INITIATION OF LIGHTNING STRIKES. THE PROTECTION PROVIDED BY LIGHT- NING RODS EQUIPPED WITH DOWN

(part I) Dr. Kim D. Coder. Professor of Tree Biology & Health Care Warnell School, University of Georgia

Total Lightning Protection for Floating Roof Petroleum Storage Tanks

LIGHTNING PHYSICS AND LIGHTNING PROTECTION: STATE OF ART 2013 Prof. Carlo Mazzetti di Pietralata

Section 9: Using a Charged Electroscope to Determine the Charge on Another Object. Examples:

Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs

Lightning Protection Of Wind Turbines. EWEC 2010 Warsaw Poland By Vidyadhar Peesapati

LECTURE #15: Thunderstorms & Lightning Hazards

Estimation of Subsurface Structure in the Western Fukuoka City fromgravity Data

Summary of Wind Turbine Accident data to 30 September 2010

Field Sensitive Air Terminal (F-SAT) Simply the Best Lightning Rod

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

with Implications for Air Terminals

Year 8 Practice Questions for Summative Assessment. NAME:...

While all thunderstorms are dangerous, the National Weather Service (NWS) defines a severe thunderstorm as one that:

THUNDERSTORMS Brett Ewing October, 2003

Lightning Protection Of Wind Turbines

Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Chapter 19, Electricity Physical Science, McDougal-Littell, 2008

Coastal Vulnerability Assessment in Semarang City, Indonesia Based on Sea Level Rise and Land Subsidence Scenarios

CLIMATE CHANGE ADAPTATION BY MEANS OF PUBLIC PRIVATE PARTNERSHIP TO ESTABLISH EARLY WARNING SYSTEM

Information Reception: Decision Support Standards: Public Notification Plan: Protection Program: Education:

Physics 2220 Fall 2010 George Williams THIRD MIDTERM - REVIEW PROBLEMS

Chapter 21. Lightning Facts. Lightning Facts 4/12/17. Lightning

LIGHTNING. If you can see it, take cover

Available online at ScienceDirect. Nuclear power plant explosions at Fukushima-Daiichi. Takashi Tsuruda*

Name: Class: Date: 1. Friction can result in the transfer of protons from one object to another as the objects rub against each other.

Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators. IESO Training

Cold Weather Preparation

Chapter Assignment Solutions

Lecture Notes (Applications Of Electric Fields)

LIGHTNING SAFETY #24 CONSTRUCTION SAFETY EDUCATION PROGRAM

CONTACT SAFETY PROGRAM MAY 2006

Severe Thunderstorms

Predicting Tsunami Inundated Area and Evacuation Road Based On Local Condition Using GIS

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

Chapter 7 Review, pages

Risk. Management. Bulletin. Created by. Insurance Fully Managed Claims Service Financial Advice paveygroup.co.uk

Topic #13: Universal Gravitation and Satellites (Teacher)

Symbol Meaning unit. 2. k 3. q. 4. r. 5. E 6. R Total 7. 1/R Total 8. P 9. V 10. I 11. R. 12. Q 13. N 14. e 15. F magnetic 16. v 17.

WIND DATA REPORT FOR THE YAKUTAT JULY 2004 APRIL 2005

SPH 4U: Unit 3 - Electric and Magnetic Fields

User Manual VX4750 Function Generator Module

Conceptual Questions. Fig.8.51 EXERCISES. 8. Why can t electric field lines cross? 9. In which direction do charges always move in an electric field?

Ta b l e o f C o n t e n t s

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Mark Scheme (Results) January International GCSE Physics (4PH0) Paper 2P

SECTION 1: SHADE IN THE LETTER OF THE BEST ANSWER ON THE BUBBLE SHEET. (60%)

Map Skills Test. 1. What do we call a person who makes maps? a. mapographer b. cartographer c. geologist d. archaeologist

PUB NLH 185 Island Interconnected System Supply Issues and Power Outages Page 1 of 9

Northwest Hydro Tech Session_2017

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

Complete Weather Intelligence for Public Safety from DTN

A Long Term Study on the Performance of Early Streamer Emission Air Terminals in a High Keraunic Region

Your Task: Read each slide then use the underlined red or underlined information to fill in your organizer.

Lightning Parameters for Engineering Applications: Recent Updates and Outlook

GRADE 6 GEOGRAPHY TERM 1 LATITUDE AND LONGITUDE (degrees)

Natural Disasters Spring, LECTURE #8: Earthquake Disasters: Monitoring & Mitigation. Date: 1 Feb 2018 (lecturer: Dr.

Southern California Edison Wildfire Mitigation & Grid Resiliency

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

1 What Is Climate? TAKE A LOOK 2. Explain Why do areas near the equator tend to have high temperatures?

Self-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual

Electric Fields and Potentials

Unit 4 Review Guide: Weather

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

PADANG EARTHQUAKE, WEST SUMATRA ON MARCH 6, 2007

Available online at ScienceDirect. The Malaysian International Tribology Conference 2013, MITC2013


Protection from touch and step voltages for sports grounds

Hurricanes 1. Thunderclouds. cool, dry air falls. warm, moist air rises

NABCEP Entry Level Exam Review Solfest practice test by Sean White

CAPACITORS / ENERGY STORED BY CAPACITORS / CHARGING AND DISCHARGING

Guided Notes Weather. Part 2: Meteorology Air Masses Fronts Weather Maps Storms Storm Preparation

Electricity. Part 1: Static Electricity

HURRICANES AND TORNADOES

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Technology 11 ( 2013 ) 1238 1243 The 4th International Conference on Electrical Engineering and Informatics (ICEEI 2013) External Lightning Protection System for Main Office Building in the Area with High Lightning Density Reynaldo Zoro* Lightning Research Center, School for Electrical Engineering & Informatic, Institut Teknologi Bandung, Indonesia, Jl. Ganesha No.10, Bandung 40132. Abstract In every industry which has main office equipped with a lot of vulnerable equipments that has to be protected against any risk of damages from natural causes and others. One of the possibilities of this risk is coming from weather phenomenon which we called lightning. The number of lightning strikes per square kilometer per year is very high in the area of Subang, west Java, Indonesia. Damages of electronics equipment and the death of human life have been reported. The aim of the research is to evaluate the local lightning activity and to design and install the protection system against the danger of lightning strikes. Lightning Protection System (LPS) is needed to prevent the damages, fire, and death of human life from direct lightning strikes. The main office in this area has unique structure. Due to its unique form of the building some modification is needed for the external protection by implementing the iron plate on the location of the structure which will be hit by lightning. Lightning protection system for the whole area of main office building are analysed by using the electro geometric concept to determine the lightning protection system for the mobilization of the workers and vehicles during their activities in the region which has high lightning activity. 2013 The Authors. Published by by Elsevier B.V. Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of of the the Faculty of of Information Science Science & & Technology, Universiti Universiti Kebangsaan Malaysia. Keywords: high lightning density, unique building and modification of external LPS 1. Introduction Subang is a city located at the west of Java Island in Indonesia. In the north side of this city a 600 hectare complex of industry is build to produced high explosive materials. This area has a very high lightning density with * Corresponding author. E-mail address: zoro@hv.ee.itb.ac.id 2212-0173 2013 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of the Faculty of Information Science & Technology, Universiti Kebangsaan Malaysia. doi: 10.1016/j.protcy.2013.12.319

Reynaldo Zoro / Procedia Technology 11 (2013 ) 1238 1243 1239 more than 10 strike/sq.km/year. A proper lightning protection system has to installed and maintained in the whole area especially in the area where the explosive factory and go down is located. A main office building and a water tower have a unique form of structures and need to be protected by modifying the external lightning protection system.most of the building are built separately within the complex and connected by roads and pedestrian. To protect the people and the vehicles in this main office area the lighting pole along the road have to be utilized by installing the lightning rod at the top of lightning pole to give suitable protection to its surrounding area.to give a good protection for the building and the structures in the complex, the external lightning protection system has to 2. Lightning Parameter Lightning parameter such in tropical area as in Fig. 1 is quite different with the lightning parameter measured in the sub-tropical country due to its weather and geological condition. Indonesia located in the tropical country with is maritime continent and produce a lot of sea salt and moisture. Updraft of air is produce by the heating of ground surface by sun and the updraft can also be produced by to orographic condition of the terrain which have a lot of island. Two lightning current parameter that play an important role for the lightning protection system are lightning peak current ( i ) in kilo ampere and steepness of lightning current (di/dt) in kilo am pere/microsecond. Voltage Elevation in the point of strike in (kilo Volt) = _ (1) Probability for peak lightning current at Subang (1 January 31 December 2000) For office building the calculation is being done by using 50% probability of the lightning peak current probability which is 25 ka For the explosive are the calculation is being done by using 80% probability which is 20 ka Fig. 1. Lightning Current Parameter The second parameter that plays an important role in the lightning protection system is the steepness of lightning current which is recorded in the Measurement Station at Mnt. Tangkuban Perahu as high as 30 ka for 50% probability. Voltage elevation on the structure which has an inductance will give the voltage rise on the structure and grounding system: di v L. dt (2)

1240 Reynaldo Zoro / Procedia Technology 11 ( 2013 ) 1238 1243 Where L = inductance value of the structure or down conductor in micro Henry/metre di/dt = steepness of lightning current in kilo ampere / micro Henry V = voltage in kilo volt 3. Local Lightning Data This building is located in the area which has high lightning density and due to their unique form of the structure the lightning protection system has to be modified to fulfil the requirement of the form of the building. Local lightning data are required to have the proper lightning protection system for calculating the coverage area using electro geometric concept (EGM) according to IEC 61305/2006 standard. The boundary marked on the map (Fig. 2) shows the lightning density in the region. It consists of offices, explosive factory; go down, storage area, etc. This facility has to be protected against lightning direct and indirect strikes, including the conference building, utility area, houses, road, etc and it will be the area protection. To derive local lightning data, the position of latitude and longitude of the area has already been measured by the GPS which are; latitude of 6, 34 longitude of 107, 50 (Fig. 3) and by using the data from Indonesia lightning detection system these following data are derived, such lightning flash density, lightning map and the detail data of polarity of the lightning strike as shown on the following table and figures. Fig. 2. Map of lightning strike at the region of the office building and the explosive region at Dahana Are at the north site of Subang city, west Java, Indonesia. Fig. 3. Lightning Flash Density in the area with show the data of higher than 10 strikes/sq.km/year 3. Striking Distance In order to have the protection good angle of the structure and the coverage area of lightning protection air terminal, the striking distance of the lightning current has to be determined. Striking distance is the striking point where the downward leader tip meets the upward streamer of the grounded object. The distance is between the striking points to the object above the ground. The striking distance ( ) is as a function of peak lightning current: =6,7, (3.1) Or the equation from standard IEC 61302/2006 can be used as follow;

Reynaldo Zoro / Procedia Technology 11 (2013 ) 1238 1243 1241 = 10, (3.2) For the external protection the striking diustance is calculated by using the 80% probability of lightning incidence which is 30 ka. By using the formula of (III-1) the striking distance Becomes; = 6,7 I 0,8 = 6,7 (30) 0,8 = 102 m This distance will be used to have the coverage area by applying the electro geometric concept for the protection of the structure at the whole area, except the explosive area which will be using the 80% probability of lightning peak current. 4. Location of Main Office Building The main office building (Fig. 4) consist of a big auditorium located in the middle of the complex and surrounding by 5 (five) others buildings that has a half round roof (Fig. 5). Fig. 4. View of main office building with 5 building around it Fig. 5. Auditorium and offices around it. By using the local lightning data, the striking distance which is derived from the electrogeometric concept is applied to the structures and has given the protection design as follow; Fig.6. Coverage area using EGM concept by installing one Extended Mast Terminal with high of 40 metre at the top roof of Auditorium Fig. 7. Top view of coverage area of one EMT with h=40 metre The calculated protection has given the fact that to protect the whole building in this office area a 40 metre high extended mast terminal have to be installed at the roof of the auditorium (Fig. 6-8) and it is not possible due to the structure condition. This mast will be very heavy. New calculation was carrried out to be able to have the proper external lightning protection system by using additional lightning rod and the iron plate at the half round building around the auditorium as shown on Fig. 9-12.

1242 Reynaldo Zoro / Procedia Technology 11 ( 2013 ) 1238 1243 Fig. 8. Coverage area using EGM concept with 1 EMT 15 metre high and 3 conventional rod with 3 metre high each at the top roof of Auditorium. Iron Plate are installed at the surrounding building Fig. 9. Top view of coverage area with one 15 metre EMT and 3 Conventional rods. Iron plate is installed at the surrounding building. Rolling sphere method as stated on the standard have given the proper external lightning protection system that can protect not only the whole building but also the people around it. At 15 metre air terminal which installed at auditorium an early streamer emmision terminal is intalled as air terminal to gain more effective protection. To allow the lightning current flow to the grounding system which is embedded on the foundation structure, a double shielded down conductor was installed. It will give low inductance of down conductor and produce no side flash to the structure or humanbeing around the down conductor, it is also can be equipped with a lightning counter installed inside a panel at the bottom of the cable. Fig. 10. Iron plate is installed as air terminal at half round roof building to give good protection. Fig. 11. Complete protection system for the whole building in main office One of the important point of this external lightning protection system is the use of the lightning counter at the bottom side of the down conductor cable. This counter will count when the lightning strike hit the LPS and it show that lightning protection system at the this main office building has work properly. The cause of the damages of the equipment inside the building such as PABX, telephone system, computer system, closed circuit tv etc can be monitored from this lightning counter. The internal Lightning Protection System, which is not reported in this research, have to be installed to protect the vulnerable equipment inside the building and minimize the equipment damages.

Reynaldo Zoro / Procedia Technology 11 (2013 ) 1238 1243 1243 4. Conclusion This complex located in the area which has a very high lightning density. The influence of lightning strikes can damage the vulnarable equipments inside the buildings and can cause death to human being due to direct lightning strikes. A suitable and proper external LPS is very important to protect the main office and the people around it. The electro geometric concept give the possibilty to modify the installation of air terminal in this very unique form of office building in order to give the optimal protection against direct lightning strike. The use of double shielded down conductor cable which connect the lightning rod at the top of 15 metre tower to the gounding system at the foundation structures of the auditorium will let the lightning current flow safely inside this cable without producing induction or side flash to the serrounding area. Due to it s very low inductance, this cable give a lot of advantages; such are, reducing voltage elevation at the grounding system that can minimize the damages of electronic equipments inside the buildings, preventing the danger of step and touch voltage in the area and recording the lightning current by using counter at the bottom of cable. This counter can gives the information about the effectivenes of external LPS and the maintenance purposes of the Lightning Protection System. Acknowledgement The Author like to thank PT. Dahana, Subang, West Java, Indonesia as the explotion material factory, belongs to the Ministry of Defence for their support and cooperation in doing this research at their premises. References [1] Berger,G. A Modified Version of The Rolling Sphere Theory. 29 th ICLP, Sweden, 2008. [2] Horvarth, Tibor. False Application of the Rolling Sphere Method in the International Standards, 29 th ICLP, Sweden, 2008. [3] IEC Standard 62305-2005, Electrical and electronic systems within structures, Protection against lightning. Italy, 2005 [4] IEC Standard 62305 2005, Physical damage to structures and life hazard, Protection against lightning. Italy, 2005 [5] Standard Nasional Indonesia (SNI) 03-7015-2004, Pemilihan bahan proteksi. Jakarta, 2004 [6] Eritech, Lightning Protection Handbook [7] Kokkinos,N. Application of Foundation Earthing Protection in Structure Equipped with Watertight Insulated Layer-Bitumen Insulation. 29 th ICLP, Sweden, 2008. [8] Petrov N., G.N. Petrova, Determination of attractive area and collection volume of earthed structures Proc. Royal Society. A, 1995. p: 450. [9] Rison, William. Lightning Air Terminals Is Shape Important. New York: Institute of Electrical and Electronics Engineers, Inc. 2004. [10] Zoro, R., Lightning Parameters in Tropical Country Measured at Mnt. Tangkuban Perahu Indonesia, Proc. in Lightning and Mountains, Chamonix Mont-Blanc. 1997 [11] Zoro, Reynaldo. Advance Course on Lightning Protection and Grounding System. Lightning Research Centre School for Electrical Engineering and Informatics, Institute of Technology Bandung, Bandung. 2012.