Aerogel counter with a Fresnel lens. Guy Paic Instituto de Ciencias Nucleares UNAM Mexico

Similar documents
A Very High Momentum Particle Identification Detector for ALICE

PoS(HIGH-pTLHC)022. The VHMPID detector in the ALICE experiment at LHC. Giacomo Volpe. INFN Bari, Italy

Lecture 16 Light transmission and optical detectors

The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511

Status of the LHCb RICH and hadron particle identification

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Results from R&D of Cherenkov detectors at Novosibirsk

Status of the LHCb RICH detector and the HPD

An Overview of RICH Detectors From PID to Velocity Spectrometers

Cherenkov Detectors in Particle Physics. Brad Wogsland University of Tennessee

Particle Detectors. How to See the Invisible

A METHOD TO ENHANCE THE SENSITIVITY OF PHOTOMULTIPLIERS FOR AIR CHERENKOV TELESCOPES

Particle Energy Loss in Matter

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

Theory English (Official)

A RICH Photon Detector Module with G-APDs

EP228 Particle Physics

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

Interaction of particles with matter - 2. Silvia Masciocchi, GSI and University of Heidelberg SS2017, Heidelberg May 3, 2017

Development of aerogel Cherenkov counters at Novosibirsk

Absorption spectrometry summary

Scintillation Detectors

RICH detectors for LHCb

Cherenkov Detector Simulation

Scintillation Detectors

THE CERN NA62 experiment [1] aims to measure the

Particle Identification with Disc DIRC at PANDA

High Momentum Particle IDentification (HMPID) in ALICE. Pusan National University In-Kwon Yoo For ALICE / HMPID Collaboration

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

The Quark-Gluon Plasma and the ALICE Experiment

Concepts of Event Reconstruction

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

Information about the T9 beam line and experimental facilities

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

Particle Energy Loss in Matter

ALICE results on identified particle spectra in p-pb collisions

arxiv: v1 [hep-ex] 18 May 2015

Cherenkov light imaging in particle and nuclear physics experiments

Revision checklist SP4 5. SP4 Waves. SP4a Describing waves. SP4b Wave speeds. SP4c Refraction

SIDIS Gas CherenkovS. S. Malace, H. Gao et al.

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

Revision checklist. Step Learning outcome Had a look Nearly there Nailed it! Step Learning outcome Had a look Nearly there Nailed it!

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Physics sources of noise in ring imaging Cherenkov detectors

-221. FEATURES OF EXPERIMENTS AT ENERGIES ABOVE 1 TeV

Detectors for astroparticle physics

Single Spin Asymmetries on proton at COMPASS

Laser Optics-II. ME 677: Laser Material Processing Instructor: Ramesh Singh 1

Four-layer aerogel Cherenkov counter

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Big, Fast, and Cheap: Precision Timing in the Next Generation of Cherenkov Detectors LAPPD Collaboration Meeting 2010

Likelihood Methods for Beam Particle Identification at the COMPASS Experiment

AEROGEL AND ITS APPLICATIONS TO RICH DETECTORS

Detector. Matthew Strugari, Dr. Garth Huber 1, Wenliang Li. University of Regina, Regina, SK, S4S 0A2, Canada. August 15, 2016.

THE FORWARD DETECTOR OF THE ANKE SPECTROMETER. SCINTILLATION AND CHERENKOV HODOSCOPES

Measurement of the e + e - π 0 γ cross section at SND

Introduction to Electromagnetic Radiation and Radiative Transfer

DESY Summer Students Program 2008: Exclusive π + Production in Deep Inelastic Scattering

Time of Flight Technique

Particle Detectors. Summer Student Lectures 2010 Werner Riegler, CERN, History of Instrumentation History of Particle Physics

Electromagnetic Waves

7. Particle identification

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Experimental Particle Physics Informal Lecture & Seminar Series Lecture 1 Detectors Overview

Particle Detectors A brief introduction with emphasis on high energy physics applications

CLAS12 at Jefferson Lab

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Recent results at the -meson region from the CMD-3 detector at the VEPP-2000 collider

What detectors measure

Name: Class: Date: Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Review of collective flow at RHIC and LHC

High-energy neutrino detection with the ANTARES underwater erenkov telescope. Manuela Vecchi Supervisor: Prof. Antonio Capone

Particle Physics Beyond Laboratory Energies

The Alice Experiment Felix Freiherr von Lüdinghausen

Picosecond Time-of-Flight Measurement for Colliders Using Cherenkov Light

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

CHAPTER 3 The Experimental Basis of Quantum Theory

Francesco Barile for the ALICE Collaboration. Università degli Studi di Bari & INFN

Identified charged hadron production in pp, p Pb and Pb Pb collisions at LHC energies with ALICE

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Dual readout with tiles for calorimetry.

Results with Hard Probes High p T Particle & Jet Suppression from RHIC to LHC

Produced in nuclear processes (e.g. fusion reactions) Solar neutrinos and supernova neutrinos

High p T Physics with ALICE/EMCal

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Review of photon physics results at Quark Matter 2012

Optic Detectors Calibration for Measuring Ultra-High Energy Extensive Air Showers Cherenkov Radiation by 532 nm Laser

Astronomy 114. Lecture 27: The Galaxy. Martin D. Weinberg. UMass/Astronomy Department

Neutrino induced muons

The Fast Interaction Trigger Upgrade for ALICE

New Results from the DREAM project

Quartz TIR Cerenkov Detectors in Hall C

The HERA-B ring imaging Cherenkov system } design and performance

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

Results on identified particle production in pp, p-pb and Pb-Pb collisions measured with ALICE at the LHC

Particle correlations in such collision?! N=n(n-1)/2. azimuthal, back-to back, multiplicity... close velocity,

3. Anaemia can be diagnosed by (a) 15 P 31 (b) 15 P 32 (c) 26 Fe 59 (d) 11 Na 24. (b) α particle (Alpha particle)

Status report on parity violation in the (1232) resonance

Transcription:

Aerogel counter with a Fresnel lens Guy Paic Instituto de Ciencias Nucleares UNAM Mexico

outline The physics case The constraint on the detector The principle of propagation and focalisation Results of prototypes with cosmics Results at the PS beam conclusions 2

The hadronisation of baryons and mesons The hadronisation is still unexplained We know a lot about the color world but not too much about the transition color world color neutral world RHIC has uncovered the so called Baryon puzzle Anomalous p/π ratios Note: the contribution of protons to the overall particle production in the thermal model is ~9% to become the dominant production above 2 GeV/c at RHIC! Necessary to measure baryon production to high momenta specifically in jets Some theoretical predictions speak of ratios p/π >>1! Necessity to measure above the present limit of ALICE for track by track identification i.e 5 GeV/c for proton kaon 3

The hadronisation scenarios The hadronisation of the thermal part happens according to the statistical model The hadrons issued from jets bear another way of hadronisation. the hadronisation is assumed to occur outside the volume belonging to the thermal part. This is due to the fact the hadronisation length is given by E Production independent of entourage The baryon puzzle at RHIC contradicts in the intermediate momentum range (2 6 GeV/c) 4

Predictions at LHC energies Many models not necessarily in agreement! 5

Change in hadrochemistry Jet quenching can leave signatures not only in the longitudinal and transverse jet energy and multiplicity distributions, but also in the hadrochemical composition of the jet fragments. S. Sapeta and U. A. Wiedemann, arxiv:0707.3494 [hep ph], July 2007. 6

Requirement on the detector a silica aerogel radiator of a very small refraction index, n~1.01. operation Inside magnet The Fine Mesh photomultipliers (FM PMT) that can work in a magnetic field The challenge: minimize the number and size of the PMT while ensuring a good uniformity of acceptance over the aerogel surface. 7

Where is the innovation Traditional light collection scheme: Cherenkov light produced in aerogel scatters in the Light Integration Box, a fraction of light reaches the photomultiplier (PMT). Efficiency: E int = M wall reflectivity ( 90% for teflon) є PMT window relative area 3.0 inch PMT: Eff=22% 1.5 inch PMT: Eff=8% } shows drastical dependence on the PMT size! 8

About photon production in aerogel The number of photons emitted by a charged particle of Z = 1 per unit path per unit wavelength depends on the particle velocity and the refraction index n(λ) of the medium and is given by: the transparency of an aerogel is given by Rayleigh scattering, the cross section of which scales as the 4th power of the photon energy. It is usual to characterize the transparency of an aerogel by the photon mean free path at λ 0 = 400 nm. Good quality aerogel 9

Production of cherenkov photons Z (cm) 5 Two kinds of photons: 0-5 10 Y(cm) 5 0-5 -10-5 0 5 X (cm) The number of photons in the wavelength interval dλ that escapes the aerogel directly without scattering is: Integrating: 10

Light collection scheme with a Fresnel lens. The Fresnel lens is placed right under the aerogel block The focal length equals to the optical path between the lens and the PMT The lens focuses the unscattered photons on to the PMT window 11

Cherenkov light emission and passage through the aerogel (absorption) Light emission spectrum The spectral density goes as ~1/λ 2, the majority are shortwavelength photons. Light absorption L abs >1m for λ>350 nm is quite small. NIMA 494 (2002) 491 494 XI Elba conference

Cherenkov light emission and passage through the aerogel (scattering) Light scattering is dominated by Rayleigh scattering, L scat ~ λ 4 Short-wavelength photons scatter more Flat aerogel block transmission : T~exp(-1/λ 4 ) Average transmission factor for the photons emitted along the particle path in the aerogel: d n x Lscat ( λ) T = exp( L ( λ )) dx = scat L scat ( λ ) d n 0 d aerogel block thickness, n refraction index ( 1 exp( )) n d 13

Cherenkov light transmission Available Matsushita Electric Works aerogel sample SP 30, produced in 2003. n=1.030, L scat =0.9 cm @400nm, it is not very transparent. Nowadays produced SP 30 has a better optical quality: L scat >3.0 cm @400nm 14

Transmitted photon spectrum Available aerogel sample, L scat =0.9 cm @400nm; 6 photoelectrons (due to unscattered photons), expected with a PMT with bialkali photocathode. Aerogel of higher transparency, L scat =3.0 cm @400nm; 18 photoelectrons (due to unscattered photons), 3 times as much! 15

prototype the Cherenkov light emitted in a cone is focused by a Fresnel lens into a ring that fits into a PMT window. For vertical particle tracks, the location of the ring does not depend on the impact point of the track. The PMT window is located in the focal plane of the lens The Fresnel lens was produced by Edmund Optics (part number NT32 684) and has F=5 inch focal distance and 10 cm diameter. Note: the lens material has refraction index n = 1:49, the Cherenkov threshold in the lens is much lower than in the aerogel, and this may produce a background signal. The walls were covered by black paper to absorb these photons 16

Spectrum of photons & PMT 17

Light transmittance through the Fresnel lens losses of the Cherenkov light in the Fresnel lens: absorption light in the lens, light reflection at the lens surface and a multiple refraction of photons on the lens grooves. the lens optical grade acrylic, transparent in the visible and nearinfrared region and has a shortwavelength cut off at 350 nm. 18

The ring diameter and the PMT Aerogel n=1.03 Cherenkov cone half opening angle θ for particles of β~1 : 0.24 rad, F=5" Fresnel lens Ring diameter d=61 mm at the PMT window, fitting the 3" PMT Aerogel n = 1:008, the opening angle θ = 0.126 rad Ring diameter would be around 32 mm, which fits into a 1.5" Fine Mesh PMT window. 19

Cosmic muon setup and results. aerogel No aerogel 20

Results with aerogel 1.015 and 1.008 Particle tests at PS accelerator aerogel samples of n=1.015 and 1.008. For both aerogels we used a Fresnel lens with focal length and a 2 in. PMT. The diameters of the Cherenkov rings are 25 and 18 mm for n=1.015and 1.008, respectively. The active diameter of the PMT photocathode was 52 mm. We were using masks of various diameters put in front of the PMT window to measure the efficiency of the light collection as a function of the PMT effective diameter. 21

22

Results for 6 GeV pions @ PS 23

Signal vs. the PMT mask diameter Signal collected with Fresnel lens and LIB, aerogel n=1.008, as a function of the PMT effective diameter. The size of the Cherenkov ring for this aerogel is 18 mm. 24

Signal collected with Fresnel lens and LIB, aerogel n=1.015, as a function of the PMT effective diameter. The size of the Cherenkov ring for this aerogel is 25 mm. 25

Position dependence of the output signal 26

27

Possible improvements Better quality aerogel. With state of the art aerogels of 1.015 we would get twice better signal Fresnel lens made of UV transparent acrylic, increasingthe photon yield by ~ 20 %. Machine the flat part of the lens to reduce the background multialkali photocathode instead of the bialkali. The multialkali photocathode has a wide spectral sensitivity range, from ultraviolet to near infrared region around 850 nm, which is particulary beneficial because long wavelength Cherenkov photons undergo much less scattering in the aerogel, 28

Conclusion The use of aerogel in conjunction with Fresnel lenses has been studied. The results show that for n< 1.015 one may get satisfactory results focusing onto a small PMT With better aerogel and Fresnel lenses promising results could be achieved. 29