Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Similar documents
PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Selection of a Capillary

Low Bleed Stationary Phases for Gas Chromatography

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

Rely on Rxi -PAH Columns

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

Organochlorine Pesticides by GCxGC-ECD

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

Selection of a Capillary GC Column

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

Certificate of Analysis

Time-Condensed Analyses by Mass Spectrometry

Choosing the Correct GC Column Dimensions and Stationary Phase

Non-Potable Water A2LA Certificate

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of 24 PAHs in Drinking Water

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

APPENDIX G. Data Management Rules. Dioxin Data Report Appendix G. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area

Sample Prep Solutions for Environmental Contaminants

18/05/2010 Soil. 18/05/2010 Soil

Results of a Sediment Survey in the Near Offshore Waters of the Proposed Quarry Site in the Vicinity of Whites Cove, Digby Neck, Nova Scotia

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit

appendix C QUALITY ASSURANCE/ QUALITY CONTROL

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Application of gas chromatography atmospheric pressure chemical ionization mass spectrometry for analysis of contaminants in environmental samples

Andrei Medvedovici, Florina Micăle, Florentin Tache

Application Note. Abstract. Authors. Environmental

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Atmospherically Deposited PBDEs, Pesticides, PCBs, and PAHs in Western US National Park Fish: Concentrations and Consumption Guidelines

The Suite for Environmental GC Analysis

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

POTENTIAL VAPOR INTRUSION ENVIRONMENTAL

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

MULTIRESIDUE ANALYSIS OF PRIORITY POLLUTANTS IN SURFACE WATERS USING EXACT MASS GC-TOF MS

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

TETRA TECH, INC. December 8, Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710

Supporting Information

Date Issued: April 01, 2013 Expiration Date: June 30, 2013

Certificate of Analysis

ENVIRONMENTAL analysis

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

Analysis, fate and risks of organic contaminants in river basins under water scarcity Valencia, 7-8 February POPs by GC-MS

Proposed Inventory of Emissions, Discharges and Losses of Substances, and Chemical Analysis Information

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9000 Gas Chromatograph

Fast, Accurate Environmental Testing

317 Elm Street Milford, NH (603) Fax (603)

Guidance on the Major Source Determination for Certain Hazardous Air Pollutants

Sample Pre-Treatment : Introduction to Commonly Used Techniques for Gas

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Reviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats

Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection. Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti

IAEA/AQ/52. IAEA Analytical Quality in Nuclear Applications Series No. 52

MEASUREMENT OF DRY DEPOSITION AMOUNT OF PAHS IN ZONGULDAK REGION

High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS

KSA Environmental Laboratory Inc.

The direct effect of the harbour. micropollutant concentration. Workshop Characterization of atmospheric pollution in harbour areas 26 June 2013

Semivolatile Organic Reference Materials

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Certificate of Accreditation

Introduction to Gas Chromatography

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Test Report. Report No. ECL01H Page 1 of 5

Certificate of Accreditation

Challenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column

Gas Chromatograph Mass Spectrometer

Pursuant to Chapter 4 of the Code of Ethics, ETAD members may not manufacture or sell dyes referred to in Annexes A and B. Annex A

Environmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons

SEDIMENT QUALITY OF THE NY/NJ HARBOR SYSTEM

Page 1 of 7 ADEQ Water Div NPDES 9/18/2017 8:52 AM

Analysis of trace polycyclic aromatic hydrocarbons and organochlorine compounds in atmospheric residues by solid-phase disk extraction

Port of San Francisco Central Basin Sediment Characterization Report -Revised-

*

ANALYTICAL REPORT. Attn: Dan Spector

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

U.S. EPA Method 8270 for multicomponent analyte determination

Method 8270C PAH. FD- Field Duplicate Samples

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Analysis of Alkyl PAHs And Geochemical Biomarkers

The Era of Mass Surveillance

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

Application of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers

ILLA SpA VIA GHISOLFI GUARESCHI, NOCETO (PR)

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

APPENDIX D Laboratory Analytical Reports

Determination of Polycyclic Aromatic Hydrocarbons (PAH) Adsorbed on Soot Formed in Pyrolysis of Acetylene at Different Temperatures

Transcription:

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups of compounds are separated in a single operation, saving time and increasing productivity. This application note describes a multi-residue method for the assessment of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs), using GC/MS with a VF-Xms column. PAHs, PCBs and OCPs have different origins and belong to different chemical classes. PAHs are formed during incomplete combustion or pyrolysis of organic matter. They contain two or more aromatic rings. PCBs are a group of chemicals containing two phenyl groups but with varying numbers of chlorine atoms. PCBs are used in many industrial and commercial applications because of their non-flammability, chemical stability, high boiling point and electrical insulating properties. OCPs mainly consist of carbon, hydrogen and chlorine. Most persistent OCPs break down slowly and can remain in the environment long after application, and bio-accumulate in living organisms. 16 PAHs, 17 PCBs and 24 OCPs were analyzed in a single operation at different concentrations. The concentration of the PAHs was ten times higher than the concentration of PCBs and OCPs, typical for environmental samples.

Materials and Methods Technique: GC/MS Column: VF-Xms, 30 m x 0.25 mm, df = 0.25 µm (part number CP8806) Sample Conc: Injection Volume: 1 µl Temperature: Carrier Gas: Results and Discussion OCPs and PCBs 0.1 µg/ml, PAHs 1 µg/ml 70 C, 40 C/min, 185 C, 15 C/min, 250 C (1 min), 5 C/min, 325 C Helium, constant flow, 1 ml/min Injection: 70 C (0.4 min), 600 C/min, 300 C (15 min), 50 C/min, 120 C, splitless Detection: Quadrupole MS, EI in SIM, source 250 C, transfer line 280 C The VF-Xms column provided a multi-residue analysis of PAHs, PCBs and OCPs in 21 minutes (Figure 1). Analyzing 57 compounds in a single run can be quite challenging because every group of compounds presents its own difficulties in separation. Among the PAHs, two pairs are normally difficult to resolve; benzo[b]fluoranthene/benzo[k]fluoranthene, which have the same mass and therefore cannot be separated by MS only, and indeno[1,2,3-cd]pyrene/dibenz[a,h]anthracene. These latter compounds have different masses, 276 and 278, respectively, and are again difficult to resolve using only MS. When analyzing PCBs, PCB 138 and PCB 163 have the same mass spectra and cannot be resolved by MS. OCPs also contain a difficult-to-resolve pair, namely cis-heptachlor epoxide/trans-heptachlor epoxide, which both have m/z 353 in their mass spectra. In SIM mode, a second m/z must be analyzed to confirm the presence of cis- or trans-heptachlor epoxide. Figures 2 to 5 show the peak pairs that can be difficult to resolve. Table 1. Peak Identification and SIM ions Peak Compound Ions 1 Naphthalene 128 2 Acenaphthene 152 3 Acenaphthylene 154 4 Fluorene 166 5 Hexachlorobenzene 284, 249 6 α-hch 183, 219 7 β-hch 181, 219 8 γ-hch 183, 219 9 PCB 18 186, 256 10 Phenanthrene 178 11 Anthracene 178 12 δ-hch 181, 219 13 PCB 28 256, 186 14 PCB 31 256, 186 15 PCB 20 256, 186 16 Heptachlor 272, 100 17 PCB 52 292, 220 18 Aldrin 66, 263 19 PCB 44 292, 220 20 trans-heptachlor epoxide 81, 353 21 cis-heptachlor epoxide 81, 237 22 PCB 155 360, 290 23 PCB 101 326, 254 24 o,p'-dde 246, 318 25 Fluoranthene 202 26 trans-chlordane 373, 237 27 cis-chlordane 373, 237 28 Endosulfan I 237, 205 29 p,p'-dde 246, 318 30 Pyrene 202 31 o,p'-ddd 235, 165 32 Dieldrin 79, 261 33 PCB 149 360, 290 34 PCB 118 326, 256 35 Endrin 263, 345 36 o,p'-ddt 235, 165 37 p,p'-ddd 235, 165 38 PCB 153 360, 290 39 Endosulfan II 239, 195 40 PCB 105 326, 256 41 Endrin aldehyde 245, 347 42 PCB 163 360, 290 43 PCB 138 360, 290 44 p,p'-ddt 235, 165 45 Endosulfan sulfate 272, 389 46 Methoxychlor 227 47 PCB 180 396, 322 48 Benz[a]anthracene 228 49 Chrysene 228 50 PCB 170 396, 324 51 PCB 194 430, 358 52 Benzo[b]fluoranthene 252 53 Benzo[k]fluoranthene 252 54 Benzo[a]pyrene 252 55 Indeno[1,2,3-c,d]pyrene 276 56 Dibenz[a,h]anthracene 278 57 Benzo[g,h,i]perylene 276 2

3 1 2 10,11 4 25,26 30 48,49 52,53 54 55,56 21 min 57 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 13,14 5,6 31 36,37 8,9 7 12 15 17 18,19 24 46 16 20 32 42,43,44 21 22 23 29 27 28 38,39 34 40 33 35 41 45 47 50 51 5.5 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 Figure 1. Total ion chromatogram multi-residue analysis using a VF-Xms column 3

trans-heptachlor epoxide PCB 163 PCB 138 cis-heptachlor epoxide 7.8 7.9 8.0 Figure 2. Selected ion chromatogram (m/z 353) of cis-heptachlor epoxide/ trans-heptachlor epoxide 10.0 10.1 10.2 Figure 3. Selected ion chromatogram (m/z 360) of PCB 138/PCB 163 10.3 benzo[b]fluoranthene benzo[k]fluoranthene indeno[1,2,3-c,d]pyrene dibenz[a,h]anthracene m/z 276 m/z 278 15.0 15.1 15.2 15.3 15.4 Figure 4. Zoomed total ion chromatogram of benzo[b]fluoranthene/benzo[k] fluoranthene 19.7 19.8 19.9 20.0 20.1 20.2 Figure 5. Selected ion chromatogram (m/z 276 and 278) of indeno[1,2,3- c,d]pyrene and dibenz[a,h]anthracene 4

Conclusion A VF-Xms column and optimized oven program delivered a multi-residue analysis of 57 environmental pollutants in 21 minutes. This ultra-low bleed FactorFour column provides exceptionally high selectivity for pesticides, compared to more non-polar ms type phases. References Anon (2005) Report Joint FAO/Who Expert Committee on Food Additives, Sixty-fourth meeting, 8-17 February 2005. Rome, Italy. http://www.epa.gov/epawaste/hazard/tsd/pcbs/pubs/ about.htm http://www.uic.edu/sph/glakes/pcb/whatarepcbs.htm http://www.akaction.org/fact_sheets/organochlorine_ Pesticide_Fact_Sheet.pdf www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc. 2010 Published in UK, October 14, 2010 SI-02443