DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

Similar documents
ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

MODEL : TX Series (Nom. sizes 15mm to 400mm)

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

( Single Case Construction )

Integral V-Cone Flowmeter VD series

VORTEX FLOWMETER (DELTA FLOWPET)

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

Volumetric Flow Measurement

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Electromagnetic Flowmeter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

AM-1000 Series COMPACT FLOWMETER

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

AM-1000 Series COMPACT FLOWMETER

Target Insertion Flowmeter

14:1400 (0206) KRAL Volumeter - OMG

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves

Field IT 50T Series Transmitters

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

E8EB-N0C2B E8EB-N0B2B

Flare/Vent Metering. Lex Scheers. If you can t t measure, you can t t manage. Advanced Production Management

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

tekcor TKC Multivariable Coriolis Flow Sensors

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

close to performances of the turbine gas meters designed for custody transfer measurements.

Odor Removal Filter Series AMF

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

Measurement of fluid flow in closed conduits

Guidelines for the Installation of SYGEF Pipes, Fittings and Valves

MCE380: Measurements and Instrumentation Lab

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Cooling Water Flow Regulator

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma)

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

Fitting PS P - B - R2

2/3 Port Valves for Fluid Control Model Selection 1

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

2/3 Port Valves for Fluid Control Model Selection 1

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting.

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

Operating Instructions for Digital Manometer. Model: MAN-SD

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

MR medium rating busbar

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

Industrial Pressure Transmitter

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure Transmitter ED 701

V-Cone Flowmeter DATASHEET

Ball screw. Linear. Coupling cover. 1Positioning table of a structure with enhanced sealing property. 3 High corrosion resistance

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

ABB Flowmeters Review of industrial processing flowmeters

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

Oscillation Flow Meter for Gases

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Fundamentals of Flow Metering

Mitigations to Flow Induced Vibration (FIV) in Control Valve Piping System using Visco-Elastic Dampers & Neoprene Pads

ISEmax CAM40/CAS40. Technical Information

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Exam #2: Fluid Kinematics and Conservation Laws April 13, 2016, 7:00 p.m. 8:40 p.m. in CE 118

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Installation guide 862 MIT / MIR

Surface-mounting thermostats Series ATH

CHAPTER THREE FLUID MECHANICS

Flow rates to 485 l/min

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

General Specifications

AT9000 Advanced Transmitter Differential Pressure Transmitters

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Exchangeable measuring insets SensyTemp TSA101

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

Tecnología en Electrónica y Control SRL Ficha Técnica

Provläsningsexemplar / Preview. First edition

Transcription:

DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative flow velocity in the line to obtain the total flow information. It is therefore especifically adaptable for metering flows in large pipelines. The probe consists of a basic unit to which a bluff body containing a thermistor sensor is secured and a mounting adaptor. The mounting adaptor comes in two types: fixed version and hot tap version. This insertion type is applicable to pipeline sizes 00 mm and up. FEATURES. Its capability of metering at high accuracy over a broad range of flow makes the instrument ideal for a wide range of gas metering applications.. Has no mechanically moving parts or elements to wear. It therefore withstands continuous service over extended periods of time with no change in its stated accuracy.. The rate of occurrence of output signal pulses in linear to the rate of flow, which simplifies integration with a total counter.. Unaffected by variations in fluid's temperature, pressure, and physical properties. 5. Small pressure loss, a particularly desirable feature in an age of energy saving. 6. Maintenance and inspection is simple. In the hot tap version, the probe can be withdrawn from the pipeline without interrupting the gas flow. 7. The preamplifier, separate from the basic meter, may be installed in any place for maximum ease of management, free from the particular piping conditions. Units provided with a local indicator which enables the operator to make sure of the flowing conditions locally are also available. GENERA SPECIFICATIONS Basic Meter Type of Installation Pipe Dia. Probe Bore Probe Material Bluff Body Max. Operating Pressure MPa Flange Ratings Operating Temp. Range Temp. Span Velocity Range Accuracy Installation Position Nozzle ength Probe Insertion ength Fixed or Hot tap 00~000 mm (8 ~80 ) 50 mm St. Steel (SCSA, SUS0) St. Steel (SUS0) 0~+0 C 50 C 0m/s Within ±% of full scale Horizontal 00 mm 0.5D where D<500 0.D wher D 500. Hot tap type is applicable in cases where fluid flow cannot be interrupted for maintenance/inspection or where flowmeter removal presents a problem.. meter mounting flanges-probe with respect to valve size 00mm ('').. D = pipe size.8 JIS0KFF.0 JIS0KRF.96 ANSI50RF lifier Type Operating Temp. Range Material Item Finish Sensor to Field Wiring. to Receiver Output Signal Power Supply Current Drain Type of explo- Sensor sion protection. Installation Conduit Connection Indicator Scale Full scale PA separate-mount 0~+60 C (Nonexplosion-proof application, 0~+60 C) Waterproof light metal alloy Munsell.5G8/ -conductor shield cable, 0 meters max. (intrisically construction) Cable: CEVS, CVVS -conductor shield cable, km max. (flameproof construction) 0.75~mm or equivalent Transistor open collector output Max. volt x curr.: 7V DC x 0 ma Pulse width: ms. V DC ± V 0 ma Max. Intrinsic safety ing5 Flameproof idg Mounting on '' pipe stand (clamp and bolts furnished) G/ (female) Flameproof packing type connection possible (cable attachment available as an option). 0 ~ 00% graduations (linear scale) Max. flow rate to be 00% OVA Corporation Head Office: Tokyo; Tel. 8--60-5. Fax 8--65-8605 Beijing Office: Tel., Fax. 86-0-655-60. Tel. 86-0-65-56 Overseas Branch Offices: Seoul. Singapore. Taipei http://www.oval.co.jp

FOW RANGES Gases with kg/m density and 5.8 mm /s, and down, kinematic viscosity Unit in m /h Probe Bore 50 mm ( ) - Pipe Dia. mm rate Min. Max. 00 ( 8 ) 5 00 50 (0 ) 6 500 00 ( ) 8 7700 00 (6 ) 860 000 500 (0 ) 50 000 600 ( ) 90 000 800 ( ) 0 55000,000 (0 ) 580 85000,500 (60 ) 00 9000,000 (80 ) 500 9000 <In case density and kinematic viscosity of gas to be measured are different from those condition listed in the left> () Minimum flowrate shall be caliculated from the following equation. Qmin = 600 (V or V) A...() Where: Qmin: Minimum rate (m /h) A: Sectional Area of the pipe (m ) : Kinematic viscosity of a liquid in use (mm / S ) : Density of the liquid in use (kg/m ) V, V: velocity (m/s) arger value V = 0., or V =.9(/ ) / is used. () Qmin/Qmax shall be larger than :/m Where: m = Q/Qmin Q: Application minimum flowrate Qmin: Minimum flowrate obtained from the equation () PERFORMANCE CHARACTERISTICS Output Frequency Characteristics by Size Output Freq. (Hz) 500 00 00 00 00 50 Pipe Dia. 00mm (8'') 50mm (0'') 00mm ('') 00mm (6'') Probe Bore 50 mm ('') 500mm (0'') 600mm ('') 800mm ('') 000mm (0'') 500mm (60'') 000mm (80'') Q f(hz).6k Q: rate m /h K: Meter Factor /P 0 00 500 000 5000 rate m /h (actual) 0 5 0 0 5 5 0 5 Pressure Drop 0 0 Pressure Drop Coeff. 5 0.5 0. 0.05 00mm (8'') 50mm (0'') 00mm ('') Probe Bore 50 mm ('') 500mm (0'') 600mm ('') 800mm ('') 00mm (6'') 000mm (0'') 500mm (60'') 000mm (80'') Meter Factor Pipe Dia. mm Nominal Meter Factor /P Pulse Freq. at Max. rate Hz Max. rate m /h 00 ( 8 ). 90 00 50 (0 ).88 87 500 00 ( ) 5.7 7 7700 00 (6 ) 0.6 66 000 500 (0 ) 8.9 000 600 ( ) 7.6 000 800 ( ) 9. 55000 0.0 500,000 5,000 0 5 0 0 5 5 0 5 rate Q (m /h) (actual) C P = 00 P: Pressure Drop (kpa) : Density (kg/m ) To determine pressure drop, convert the flow rate in m /h (normal) into an actual flow rate under pressure in m /h (actual), find the point C where the actual flow rate intersects a given pipe size (slant line), and substitute it into the equation above. 000 (0 ) 76.8 07 85000 500 (60 ) 7 07 9000 000 (80 ) 08 06 9000

Hot Tap Type Fixed Typeon Conduit Connection G/ ø00 Unit in mm Terminal Box Terminal Box Unit in mm ø98 75 ø98 Conduit Connection G/ V Dimension JIS0K 9 JIS0K 05 ANSI50 9 Vent valve (5mm) Ball valve Stroke: s s=y+n+v+5 V t : 50 Y+n+v+559 meter Mtg. Flange Bore 00 mm Direction of Probe ød (Pipe Dia.) 6.5 0, Approx +Y+8, Approx. Mounting Nozzle ength =00mm Std. Insert ength Y= 0.5D or 0.D meter Mtg. Flange Mounting Nozzle ength n (00mm Std.) Direction of Probe ød(pipe Dia.) Insert Y ength 0.D or 0.5D 6.5 Approximate Mass Unit in kg Flange Ratings Hot Tap Varsion Fixed Version JIS0K 97 JIS0K 0 ANSI 50 97 lifier Terminal Description Units in mm flow indicator 57 85 Conduit Connection G/ 5(86) 5(06) 80 8 Input Terminal Box ø8 Output Terminal Box +V+V - DC SIG COM 8 5 meter Terminal Box Be sure to ground housing of 6 76 ø98 Conduit Connection G/ Input Terminal Box 66 Max. 0 m Input Terminal Box NOTE: Figures in brackets ( ) apply to the unit without flow indicator

MODE CODE NUMBER Code No. Item Description Model V F Thermister Type Delta meter Probe Bore Size 0 5 0 50mm ( ) Insertion, fixed type Style 5 Insertion, hot tap type Meter body material D St. steel SCSA JIS 0K Pressure rating JIS 0K, ANSI 50 Bluff body material D St. steel SUS0 Sensing Construction Standard lifier construciton Non-explosion proof. mounting 6 Explosion proof lifer model PA 0 None ocal indication indicator provided 0 None Output signal Unfactored pulse output TYPICA PIPING INSTRUCTIONS In making flow measurements with inferential flowmeters, it is generally desired that the flow pattern of fluid coming into the meter be as uniform as possible. For this reason, take flow straightening into consideration when you plan to install a Dealta meter. With OVA flow straightening devices (flow straightener (up to ") and downstream pipe), straight pipe sections are in most cases not required. But if you plan to use straight pipes only, secure the straight pipe section required in accordance with the ISO standards, using a Sch. 0 pipe, as shown in the table. Mounting: Pipeline hold-down span in areas where the meter is installed should be short enough to minimize vibration to the meter. Pulsation: If pulsation is present, adhere to the following condition: 0.7 V N < 00 where N: Pulsation pressure (kpa) : Density of fluid in service (kg/m ) v: Minimum flow velocity (m/s) Piping Condition Req d of ength Straight Pipe() Description Reducer 5D min. A concentric reducer upstread of meter. D min. An elbow upstream of meter. Elbow 5D min. Two elbows in horiz. plane upstream of meter. 0D min. Two elbows in vert. plane upstream of meter. Sluice Valve 5D min. A fully open sluice valve upstream of meter. Secure downstream straight pipe length greater than 5D. "D" denotes pipeline diameter, not probe bore.

HOOKUP WITH RECEIVING INSTRUMENTS Actual Totalization and Instantaneous Indication ine temperature and pressure are considered approximately constant and correction factor can be multiplied as constant: Total Indication Converter (SU08) Totalizer (E0) Instantaneous Indication Converter (SU5) Indicator (E) Total and Instantaneous Indication ~ 0 ma DC or ~ 5 V DC Converter/ Compensator (E08 ) Pulse output ine temperature and pressure are automatically compensated, and total and instantaneous flow readout output) are obtained: Total and Instantaneous Indicator ~ 0 ma DC OVA MODE E000 Unfactored Pulse Computer (E000) Factored Pulse Pressure Transmitter Thermometer Bulb V DC power source is required for the preamplifier. In case of using a receiving instrument incapable of furnishing V DC, use OVA pulse repeater Model SU08. For details of individual receiving instruments, refer to respective general specification sheets. 5

When making inquiries, please advise the following: (fill in the blanks or check [ ] with mark). Name of gas:. range:. Temperature range:. Pressure range: 5. Sp. weight or sp. gr. 6. Viscosity: 7. Connections: 8. straightening devices: 9. Flange rating: 0. ocal indication:. Compensation: Max. Normal Min. [ ] m /h (normal) [ ] m /h (actual) Max. Normal Min. C Max. Normal Min. [ ] MPa (gauge) [ ] Density kg/m (normal), [ ] kg/m (actual) Sp. Gr. [ ] mpa s [ ] mm /s at C Bore [ ] inch [ ] mm [ ] Req d [ ] Not req d (If not required, please prepare the straightening pipe and downstream pipe of specific length, bore and sch. no.) [ ] JIS K, [ ] ANSI Class [ ] FF [ ] RF [ ] Req d [ ] Not req d [ ] Temp. and press. compensation [ ] Press. compensation [ ] Temp. compensation. Compensation range:. Compensation referance:. Compression coefficient: 5. Individual accuracy testing: Temp. ~ C Ref. temp. C [ ] Req d [ ] Not req'd Press. ~ MPa (gauge) Ref. Press. MPa (gauge) 6. Receiving instruments: [ ] Totalizer [ ] Indicator [ ] Indicating recorder [ ] Others ( ) 7. Other information: (Types, specifications, etc. of electrical instruments to be coupled) The specification as of June, 006 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: