Investigation into the computational techniques of power system modelling for a DC railway

Similar documents
Fault Calculation Methods

It was safe It was economical It worked (in the sense that it met all the specified operating requirements).

16 Appendix 16 Electrical Research Association Report

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur

Harmonic Modeling of Networks

Sinusoidal Steady State Analysis (AC Analysis) Part II

A Study on the Impedance Calculation by using Equivalent Model in Catenary System

EE 3120 Electric Energy Systems Study Guide for Prerequisite Test Wednesday, Jan 18, pm, Room TBA

Changes to ESTA boundaries in London North Eastern Route. Dear colleague,

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

Module 4. Single-phase AC Circuits

Traffic Modelling for Moving-Block Train Control System

Facing the winter challenges for railways in Europe - Winter & Railways Fact Sheet Root Causes Rolling Stock and Infrastructure UIC Survey Evaluation

TRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR)

Reactive Power Solutions

Chapter 8: Unsymmetrical Faults

Chapter 3 AUTOMATIC VOLTAGE CONTROL

UNIT 4 DC EQUIVALENT CIRCUIT AND NETWORK THEOREMS

Sinusoidal Steady-State Analysis

EFFECT OF TEMPERATURE CHANGE ON THE RESISTANCE OF TRANSMISSION LINE LOSSES IN ELECTRICAL POWER NETWORK

Worked Example for the Calculation of Earthing Current and Electric Shock Hazard Potential Difference in a Rod and Grid Earthing System

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

Electric Circuits II Sinusoidal Steady State Analysis. Dr. Firas Obeidat

Calculations of Capacitance for Transposed Bundled Conductor Transmission Lines

Chapter 2 Voltage-, Current-, and Z-source Converters

How to measure complex impedance at high frequencies where phase measurement is unreliable.

Optimising Power Management Strategies for Railway Traction Systems. Shaofeng Lu

Module 3 : Sequence Components and Fault Analysis

Tutorial 2: Modelling Transmission

YMCA UNIVERSITY OF SCIENCE AND TECHNOLOGY, FARIDABAD SCHEME OF STUDIES & EXAMINATIONS B.TECH 2 nd YEAR (SEMESTER IV) ELECTRICAL ENGINEERING ( )

Incorporation of Asynchronous Generators as PQ Model in Load Flow Analysis for Power Systems with Wind Generation

Modelling the Dynamic Line Parameter of 25 kv AC Railway Electric Traction Lines at Earth Cuttings

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

Fundamentals of Electrical Circuit Analysis

QUESTION BANK SUBJECT: NETWORK ANALYSIS (10ES34)

4 Fault Calculations. Introduction 4.1. Three phase fault calculations 4.2. Symmetrical component analysis 4.3 of a three-phase network

GIS data classes used within the November 2013 Environmental Statement Engineering Maps

POWER SEMICONDUCTOR BASED ELECTRIC DRIVES

LO 1: Three Phase Circuits

TRANSIENTS POWER SYSTEM. Theory and Applications TERUO OHNO AKIH1RO AMETANI NAOTO NAGAOKA YOSHIHIRO BABA. CRC Press. Taylor & Francis Croup

Induction_P1. 1. [1 mark]

BFF1303: ELECTRICAL / ELECTRONICS ENGINEERING. Alternating Current Circuits : Basic Law

Impedance relay and protection assemblies

VKES. Contents. Page 2 No 213, 13th Main RBI Layout JP Nagar 7th Phase, Bangalore Vidyuth Kanti Engineering Services

Application Note. Paralleling of EconoPACK TM + Date: Page

COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS

Analysis of factors affecting station capacitor bank switching transients

Module 3 : Sequence Components and Fault Analysis

Typical information required from the data collection can be grouped into four categories, enumerated as below.

Data Collection. Lecture Notes in Transportation Systems Engineering. Prof. Tom V. Mathew. 1 Overview 1

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION

EE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A

3.1 Superposition theorem

In the previous chapter, attention was confined

Fundamentals of Electric Circuits, Second Edition - Alexander/Sadiku

Sinusoidal Steady State Analysis (AC Analysis) Part I

Transmission and Distribution of Electrical Power

11. AC Circuit Power Analysis

Fault Locating PRESENTED BY ERIK SCHELLENBERG IDAHO POWER

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

GENERATOR INTERCONNECTION APPLICATION

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)

Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

The prediction of passenger flow under transport disturbance using accumulated passenger data

Basics of Electric Circuits

Proximity effect on bare buried conductors connecting together MV/LV substations earth electrodes

BASIC NETWORK ANALYSIS

SHORT QUESTIONS AND ANSWERS. Year/ Semester/ Class : III/ V/ EEE Academic Year: Subject Code/ Name: EE6501/ Power System Analysis

Chapter 10 AC Analysis Using Phasors

19.3 Design of Feeders for Industrial Power Systems

Three Core XLPE/LSF/SWA/LSF Power Cable

Power Factor Improvement

Charge/discharge control of a train with on-board energy storage devices for energy minimization and consideration of catenary free operation

Proposal of Lightning Risk Assessment Method Based on the Lightning Current Probability Function for Railway Power Supply System

Thevenin Norton Equivalencies - GATE Study Material in PDF

CURRENT SOURCES EXAMPLE 1 Find the source voltage Vs and the current I1 for the circuit shown below SOURCE CONVERSIONS

Introduction to Synchronous. Machines. Kevin Gaughan

EE 451 Power System Stability

Effective Design of Large Grounding Systems

EE221 - Practice for the Midterm Exam

Faults on Electrical System. A Research

"Transport statistics" MEETING OF THE WORKING GROUP ON RAIL TRANSPORT STATISTICS. Luxembourg, 25 and 26 June Bech Building.

FY2011 Capital Budget Reprogramming

EE 742 Chapter 3: Power System in the Steady State. Y. Baghzouz

Numerical and Experimental Study on Vibration and Noise of Embedded Rail System

Updated: Page 1 of 6

Transformer. Transformer comprises two or more windings coupled by a common magnetic circuit (M.C.).

KINGS COLLEGE OF ENGINEERING Punalkulam

Elevated Neutral to Earth Voltages Due to Harmonics A T&D Update

Notes for course EE1.1 Circuit Analysis TOPIC 10 2-PORT CIRCUITS

ECEN 460 Exam 1 Fall 2018

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 2 DC circuits and network theorems

EE-201 Review Exam I. 1. The voltage Vx in the circuit below is: (1) 3V (2) 2V (3) -2V (4) 1V (5) -1V (6) None of above

ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT

Performance Improvement of the Radial Distribution System by using Switched Capacitor Banks

Bridge Measurement 2.1 INTRODUCTION Advantages of Bridge Circuit

THERE MUST BE 50 WAYS TO FIND YOUR VALUES: AN EXPLORATION OF CIRCUIT ANALYSIS TECHNIQUES FROM OHM S LAW TO EQUIVALENT CIRCUITS

Transcription:

Power Supply System Analysis, Design and Planning 123 Investigation into the computational techniques of power system modelling for a DC railway A. Finlayson 1, C. J. Goodman 2 & R. D. White 1 1 Atkins Rail, UK 2 University of Birmingham, UK Abstract The use of computer simulation techniques is now a fundamental part of the design process for electrified railways and at the feasibility stage clients will often request detailed calculations to be performed for the basic design. This will establish a level of confidence in both the project and basic design parameters that will justify the capital expenditure further on in the project life-cycle. This paper will address how the total impedance of a railway network may be represented, where the impedances of the traction return circuit and traction power system are either combined together to form one impedance or studied independent of one another. The accuracy of the modelling in this manner, particularly how it affects the accuracy of rail voltage results shall be assessed. It will also examine how much impedance is typically in the rails and what proportion this needs to be before it has an unacceptable effect on the numerical results. To assess this, a range of proportions will be studied, for example 70% of the total impedance to be modelled in the conductor with 30% modelled in the rails, 60%/40%, etc. In this way, a proper scientific assessment of the combined or split calculation methods can be made via simplified case studies. Keywords: DC railway, modelling, simulation, computational techniques, accuracy, numerical method, rail voltage, stray current. 1 Introduction DC electrified railway systems across the world are growing, both in passenger and freight traffic, as an alternative solution to increasing road congestion. DC electrified railways account for approximately 50% of electrified railway lines throughout the world [1]. This growth may be in the form of new build railway doi:10.2495/978-1-84564-498- 7/ 13

124 Power Supply, Energy Management and Catenary Problems systems or the upgrade of existing railway systems and is inclusive of metro, tramway, light rail and heavy rail systems. However this growth has to be managed to ensure that the proposals for an improved infrastructure are designed both safely and correctly and that the design delivers value for money. Computer simulation is the tool that many consultants and manufacturers, associated with the rail industry, are using to evaluate proposals and validate final designs prior to the launch of the project and any major capital expenditure. The use of computer simulation techniques is now a fundamental part of the design process for electrified railways and at the tender stage clients will often request detailed calculations to be performed for the basic design [2]. This will establish a level of confidence in both the project and basic design parameters that will justify the capital expenditure further on in the project life-cycle. 1.1 DC railway modelling and simulation Modelling and simulation are the names we use for applying the laws of physics and logic via the processing power of computers to predict the behaviour and performance of railway infrastructure [2]. The various levels of engineering modelling and simulation with respect to the DC railway may be considered as; timetable and operational planning, train performance and signalling, traction equipment and the power supply system. These engineering levels are not considered to be exhaustive but what is important is the power system supply, as this paper is primarily concerned with the modelling of the power system for the DC railway. 2 The DC railway 2.1 Operational functions The DC railway usually has the primary operational function of passenger transportation, whereas the AC railway has the dual operational functions of passenger and freight transportation. However the DC railway may also be used within the mining industry, as well as freight transportation [3], so it may be considered to have dual operational functions also. However, for the purpose of this paper the DC railway shall be considered as predominantly suburban railways often referred to as transit systems. Transit systems may be classified based upon the demand for traction current from the power system. For example, a metropolitan railway (metro) may be considered to be a mass transit system as there will be more trains carrying more passengers with short headways between trains and therefore a large demand for traction current from the power system. Conversely, a tram railway may be considered to be a light rapid transit (LRT) system as there will be less trams and also less demand for traction current from the power system than the mass transit system. Either of these systems may utilise an overhead line or third/fourth rail feeding arrangement. The following DC traction supplies are commonly used [4]:

Power Supply System Analysis, Design and Planning 125 3000 V (overhead line) 1500 V (overhead line) 750 V (third rail and overhead line) 630 V (third and fourth rail) 2.2 Components of the DC railway The DC electrified railway comprises of many interacting variables or components. These variables are usually contained within sub-systems such as; civil engineering, permanent way, electrification, signalling, tele-communications, rolling stock, station services and third parties outside the railway environment. Whilst this list is typical (non-exhaustive), all of these variables must be considered both individually and interacting with one another during the design process of a railway system. However, for the purpose of this paper the components that are of most concern are; Electrification Rolling stock Signalling 2.3 Other considerations for modelling In studying the DC railway power system, there are two further technical problems that need to be included in the circuit model of the DC power system. Firstly, there is the variation of rail voltage with respect to the train operational timetable and secondly there is the magnitude of stray current with respect to the train operational timetable. 33kV AC 33kV AC 11kV AC 11kV AC 750VDC 750VDC 750VDC T1 T2 R2 R1 Figure 1: The DC railway represented in a single line diagram. 2.4 DC railway operation Figure 1 shows a typical two track DC railway with one feeder station with a primary voltage of 33 kv AC and a secondary voltage of 11 kv AC. The

126 Power Supply, Energy Management and Catenary Problems 11 kv AC is then rectified and an output voltage of 750 V DC is produced which in turn will power the rolling stock on the rail network. The rolling stock will draw traction current from T2 and will return traction current through R2. However not all of the traction return current will return through the running rails and this may be due to the earthing and track bonding arrangements associated with the DC railway. 3 Choosing the model and method 3.1 The basic model There are many methods available to us in solving the power system model of a DC railway. Examples of these may include multi-conductor modelling, finite element analysis or transmission line theory to name but a few. However, given the nature of the DC railway, the power system model may be considered to be dynamic, i.e. the electrical load changes with demand and with multiple electrical loads, i.e. trains. Whilst these parameters may appear complex, the DC railway power system is easier to model than the alternative AC railway. This is because the effects of capacitive and inductive reactance in the equivalent steady state circuits may be ignored due to the general principles of DC circuit theory [5]. Applying this to figure 1 will give rise to the equivalent circuit shown in figure 2, where Z c1, Z c2 and Z c3 represent the impedance of the traction power conductor, whilst Z r1, Z r2 and Z r3 represent the impedance of the traction return conductor. Traction Power Z c1 Z c2 Z c3 Substation 1 Zt Zt Zt Substation 2 Train 1 I Train 2 I Train n I Return Rail Z r1 Z r2 Z r3 Figure 2: Electrical circuit for DC railway. Figure 2 may still not be considered to be the simplest model of the DC railway. The electrical substations may be modelled in their Thévinin equivalent model, a voltage source (V s ) with a source impedance (Z s ) and the train may be modelled as an impedance (Z t ) that is dependent upon whether the train is motoring, coasting or braking. Figure 3 now shows two cases of the simplified circuit, with the Thévénin equivalent voltage source representing two electrical substations and a single train represented by an impedance somewhere between the two electrical substations. The circuit shown to the left of figure 3 represents the DC railway where the traction power and traction return conductors are split from one

Power Supply System Analysis, Design and Planning 127 another, whilst the circuit to the right shows them combined. The circuit to the right suggests that the DC railway power system model may be solved as a simple DC circuit, using short transmission line theory [6]. Figure 3: Simplified electrical circuit of a DC railway. Traction Power Conductor Z c1 Z c1 Z c2 Traction Power Conductor I t1 I t1 I t2 Return Rails Z r1u Z r1d Z r1u Z r2d Return Rails 50% I t1 50% I t1 50% I t1 50% I t1 50% I t2 50% I t2 Figure 4: Developing the combined impedance model. 3.2 Representing the traction return conductor in the combined impedance model Figure 3 is representative of a one track railway. In practice, the DC railway, under consideration for this paper, will usually be a minimum of two tracks, namely up (u) and down (d). Considering figure 4, there are two trains present, one on each track and there are four traction return conductors, or as is more commonly known return paths. These return paths are considered to have identical impedance characteristics and the percentage of traction return current (It 1 and It 2 ) in each return path is shown. Considering the configuration shown to the left of figure 4, will give rise to the equivalent impedance of all the return paths combined being expressed as: Zr Zr = 1u n Ω (1) n where n is equal to the total number of traction return conductors in the circuit. However, considering the configuration to the right of figure 4, the equivalent impedance of all the return paths combined will be expressed as: Zr n T * Zr = n 1u Ω (2)

128 Power Supply, Energy Management and Catenary Problems where T is the number of trains present. However, because the number of trains present between electrical substations and on different tracks varies, this will be difficult to program in a computer simulation tool. The equivalent impedance of all the return paths combined may be expressed as an alternative to equation 1 by Zrn = Zr1 u Ω (3) This paper will assess which the accuracy of modelling the equivalent return rail impedance as either equations 1 or 3 for a number of tracks, as these are feasible methods that may be used by computer simulation tools. 3.3 The method Figure 3 may be solved via a number of well known network analysis techniques such as mesh or nodal analysis [5]. For simple circuits such as that shown in figure 3 where there is only 1 train present, the solution may be solved by deriving linear equations and solving them as simultaneous equations. If the circuit contains more electrical loads, it is better to solve the circuit via a series of linear equations represented in matrices where the general equation may be given as [ V ] [ Z] *[ I ] = (4) The computational efficiency of the numerical procedures undertaken by both mesh and nodal analysis may be measured by counting the number of numerical operations (OC) i.e. multiplication, division, addition and subtraction for each equation N to be solved, i.e. N is equal to the number of nodes in the circuit or the number of loop currents in the circuit, dependent upon the network analysis technique chosen. This may be defined as [10]; 3 2 2N 3N 7N OC = + (5) 3 2 6 Table 1 shows the difference in operational counts taking into account the simplified models shown in figure 3. Table 1 illustrates that nodal analysis has a much lower OC when 4 or more linear equations are required to be solved. This can be attributed to the fact that in nodal analysis, each node represents an equation and one node has to be set to zero. Table 1: Summary of OC. Number of Traction Return Paths Mesh Analysis Nodal Analysis N OC N OC 1 2 9 2 9 2 4 62 3 28 4 8 428 5 115 6 12 1354 7 294 8 16 3096 9 527

Power Supply System Analysis, Design and Planning 129 If using mesh analysis, each loop current represents an equation and each and every loop current must be used. This means that for an equivalent circuit that requires 4 or more equations to be solved, mesh analysis will always have one more equation to be solved than nodal analysis, thus meaning that nodal analysis is the more efficient method. 3.4 Injecting train currents If the combined impedance circuit of figure 3 is used to solve the power system then it presents us with a problem as the technical issues cited in section 2.3 are not represented in the model, whereas the rail voltage is represented and calculated directly in the split impedance model. This problem may be overcome by either including these parameters in the model for real time simulation or they can be accounted for in a post processing program, i.e. a separate program that operates on the results from the initial simulation [7]. This may be done by injecting the train currents (I t ) into a homogenous rail. The ground impedance (Z e ) is represented as a lumped parameter that ignores the effect of ground capacitance, because any reactive component represented by the ground will be so small that it can be ignored [4, 8, and 9] and in any case is only relevant for transient conditions, as is shown in figure 5. The current flowing in the earth (I e ) represents the stray current and this may also be studied as part of the post processing program. Figure 5: Post process injecting train currents model. 4 Case studies The theoretical analysis of railway modelling techniques discussed in section 3 may be applied to the practical railway, where numerical analysis can be applied to ascertain the accuracy of modelling between the split impedance method (with the traction return path impedance modelled as per equation 2) and the combined impedance method with the equivalent traction return path impedance modelled as per equations 1 and 3. The network analysis technique chosen was nodal analysis as this calculates the train voltage directly and is considered to be more efficient than mesh analysis, as defined in section 3.4. The following railway types have been identified as case studies; 1500 V DC Overhead Line Railway (OHL) 750 V DC 3 rd Rail Conductor Railway 750 V DC Overhead Line Railway

130 Power Supply, Energy Management and Catenary Problems Practical traction return circuits, traction power system and voltage source impedances have been used in the case studies. A range of proportions have been studied, for example 60% of the total impedance to be modelled in the traction conductor (α) with 40% modelled in the rails etc., where the summation of the traction powers system and return circuit impedances is equivalent to the loop impedance Z L. Each case study includes six traction return circuit with up to six trains present, i.e. one on each track. 4.1 Calculating the error The train voltage may be expressed as a percentage of the supply voltage derived by the electrical substation. This may be expressed generally as; Vtrain Vt = 100 % (6) Vs 1 where V train is the train voltage and Vs 1 is the electrical substation voltage. Equation 6 will satisfy both the split and combined impedance analyses. The error in train voltage calculation may be expressed as; % combined error = Vt split Vt % (7) where Vt split is the result of equation 6 for the split impedance model and Vt combined is the result for the combined impedance method. A back calculation may be performed using the result of equation 7 to calculate the error in terms of voltage magnitude if required, as shown in equation 8. 4.2 Summary of results % error = Vs V (8) 100 V 1 Table 2 shows the percentage error (%) in train voltage calculation, using equation 7. 5 Discussion and conclusion 5.1 Discussion The results in table 2 suggest that either equations 1 and 3 for the equivalent traction return path impedance are satisfied when there is only one train present, as in the case of equation 1 and six trains being present, as in the case of equation 3. This does not definitively define which equivalent rail return impedance should be used. Therefore an intermediate step was introduced by assessing three trains being present. The choice for three trains is purely

Power Supply System Analysis, Design and Planning 131 System Voltage V DC 1500 750 750 750 Type OHL OHL 3rd rail 3rd rail ZL Ω/m 0.0784 0.1472 0.0651 0.0828 α% 60 55 37 50 Table 2: Summary of case study results. Train Current A Substation Spacing km Error for 1 Train and six return paths Eqn. (1) Eqn. (3) Error for 3 Trains and six return paths Eqn. (1) Eqn. (3) % error % error % error % error 4000 2 0 1.668-0.667 1.001 1000 1.5 0 2.705-1.082 1.623 5000 3 0 17.086-6.834 10.252 5000 3 0 17.112-6.845 10.267 Error for 6 Trains and six return paths Eqn. (1) Eqn. (3) % error % error -1.668 0-2.705 0-17.086 0-17.112 0

132 Power Supply, Energy Management and Catenary Problems academic and is used to define a utilisation factor of the traction return circuits, although in reality the number of trains may vary. This now shows that the error is lower when using equation 1 to derive the equivalent traction return impedance. However, whilst the error is acceptable for the overhead line railways, it is not so for the 3 rd rail railway. The impedance is too low in the traction power conductor, allowing a large voltage drop to occur between the train and the electrical substation, mainly due to the high values of current drawn by the trains. Furthermore, the impedance in the traction return circuit is more dominant and the inconsistency in the assumptions of equations 1 and 3 suggest that this impedance must be modelled accurately, i.e. as per equation 2 and the split impedance method. Therefore this type of railway should be modelled as a split impedance railway, such that the train and rail voltages are calculated correctly. Furthermore, it is noticeable that the magnitude of percentage error increases as the number of tracks occupied increases. This must also be considered when deriving the power system model, with respect to split or combined impedance method. 5.2 Conclusion The case studies confirm that the most efficient method for solving the power system model is to combine the traction power and return conductor impedances such that the OC of the circuit is reduced to as low as reasonably possible. This will allow post process simulation of the data obtained from the real time solution and allow effective management of the computing overhead that is always the fundamental driver with computational techniques and the desired accuracy. This statement is true, with the exception of the 3 rd rail traction conductor railway, where the most appropriate method would be to model the impedances of the railway separately. Acknowledgement and disclaimer Information and guidance given in this paper are views held by the authors. The authors would like to thank colleagues within Atkins Rail and the University of Birmingham for their support and advice in writing this paper and for their kind permission in allowing this work to be published as part of the collaborative agreement to develop a DC multi train simulator. The authors, Atkins Rail and the University of Birmingham accept no liability to anyone for any loss or damage caused by any error or omission in the work, whether such error or omission is the result of negligence or any other cause. References [1] Profillidis, VA. (2000). Railway Engineering. 2 nd Edition. Aldershot: Ashgate Publishing Ltd. Chapter 13 pp252. ISBN 0 7546 1279 1.

Power Supply System Analysis, Design and Planning 133 [2] Goodman, CJ, (2005). Modelling and Simulation. The IEE Second Residential Course on REIS 2005. Wrightsons. Chapter D3. ISBN 0 86341 511 3. [3] BS EN50122-1:1998 Railway applications - Fixed installations Part 1: Protective provisions relating to electrical safety and earthing. [4] Kiessling, F, Puschmann, R, Scmeider, A. (2001). Contact Lines for Electric Railways. 1 st Edition. Munich Erlangen: Publicis Coproate Publishing Ltd. Chapter 1 pp33.isbn 3 89578 152 5. [5] Bird, J. (2004). Electrical Circuit Theory and Technology. Revised 2 nd Edition. Newnes. Chapters 30, 31, 33, 44 pp 531 559, 575 598 and 869 900. ISBN 0 7506 5784 7 [6] Stevenson, WD Jr. (1982). Elements of Power System Analysis. 4 th Edition. McGraw Hill. Chapters 5, pp 88 126. ISBN 0 07 066584 2 [7] Yu, JG, (1992). Computer Analysis of Touch Voltages and Stray Currents for DC Railways. PhD Thesis submitted to the University of Birmingham, UK [8] White, RD, Zhang, Z (2003) Atkins Rail internal report. Predictions of 50Hz induced voltage into lineside cables on 25kV railway. Report Number: BF 5001270/RDW/001. Issue 4.0 August 2003 [9] Case, S, (2005). Earthing, Bonding and Stray Current Mitigation - Principles. The IEE Second Residential Course on REIS 2005. Wrightsons. Chapter D4. ISBN 0 86341 511 3. [10] Gerald CF, Wheatley PO. (2004). Applied Numerical Analysis. 7 th Edition. Pearson/Addison Wesley. Chapter 2 pp 88 100. ISBN 0 321 1909 X