Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT
OUTDOOR SENSOR FEATURES Buttons: MODE,,,MEM, CH, HISTORY, 5 day weather forecast in the following combinations: Sunny, Partly cloudy, Cloudy, Rainy, Stormy, Snowy, Freezing point indicator Barometric pressure ( inhg and HpA selectable) with history tracing function Altitude height and first day weather forecast settable Connect with max 3 outdoor sensors Outdoor temperature with high and low temperature alert function Outdoor humidity Indoor temperature and humidity In & outdoor temperature and humidity trend In & outdoor temperature in or Time in 12/24H format Dual alarms with snooze function (each with two alarm modes: Monday-Friday/Saturday-Sunday) Built-in calendar in D-M order Weekday in 7 languages: English, German, French, Italian, Spanish, Dutch and Danish Real time moonphase Low power indicator USB cable for perpetual backlight ( 3*AA back-up batteries for memorizing time when cutting off DC power) GETTING POWERED Open the battery compartment cover. Insert 3 x AA back-up batteries to main unit or connect it with USB cable, and insert 2 x AAA batteries to transmitter according to the correct polarity showed in the compartment. RF (Outdoor Temperature and Humidity) Hygrometer will automatically receive signal sending back from the external sensor after powering on, the receiving status will last for max 3 minutes, the receiving antenna signal will flash, if no signal received in 3 minutes, will exist and stop receiving outdoor signal. If no signal matched within 1 hour, no outdoor data --- will be displayed on the screen.
Press CH button on main unit to change channel display. The channel switch order is CH1 --> CH2--> CH3 -->Channel scan (from CH1 to CH2 to CH3, 10 seconds intervals). Press and hold CH button more than 3 seconds, then manually enter into RF re-registration. Remarks: 1. The distance of main unit or transmitter should be at least 5~6.5 feet (1.5~2 meters) away from any interfering sources such as computer monitors or TV sets. 2. The main unit cannot stand close to metal window frames. 3. Please do not use other electrical products such as headphones or speakers operating at the same signal frequency, which may cause interference. 4. Neighbors using electrical devices operating on the same signal frequency can also cause interference. TEMPERATURE AND HUMIDITY 1. Indoor temperature range: 0 ~+50 +32 ~+122 2. Outdoor temperature range: -20 ~+50-4 ~+122 Remarks: LL.L or HH.H will display when out of the above range 3. Indoor and outdoor humidity range: 20%~95% Remarks: 20% or 95% will display when out of range 4. Press MEM to check maximum and minimum data OUTDOOR TEMPERATURE ALERT SETTING In normal time mode, press to check alert temperature value; press and hold to enter alert setting, the digits begin flashing. Press MODE to set items. The sequence is ON/OFF temperature upper limit lower limit exit. Default temperature upper limit is +70 /lower limit is -50 /the alert function defaults to be OFF. When outdoor temperature reaches the preset alert value, it will start sounding; the temperature and alert icon flash simultaneously. Press any button will stop the alert, but the temperature and alert icon will still flash. When the temperature returns to the range within two limits, the alert stops. Users could set the temperature alert function to be off to stop the function. BAROMETRIC PRESSURE AND WEAHTER SETTING In normal time mode, press HISTORY to trace the barometric pressure data of the past 12 hours. In normal time mode, press and hold HISTORY to set altitude height weather status air pressure unit exit. Press or to set desired values. The default value is 1012hpa/70M. Air pressure unit is either hpa or inhg. The sequence of weather status setting is partly-cloudy, cloudy, rainy, stormy and sunny. WEATHER FORECAST Weather forecast will appear in one of following combinations: Sunny Partly cloudy Cloudy Rainy Stormy Snowy Freezing Point Icon Real time weather forecast is based on the change of air pressure. Therefore the weather icon changes according to the alteration of air pressure value: if the air pressure changes by +/- 2 hpa, when it goes up the unit displays sunny; it turns to rainy while it goes down. The following four days forecast are based on change of present trend. Remarks: 1. When temperature is lower than 3.9 and it rains, then the forecast would change to Snowy status. 2. Freezing point indicator will appear when RF temperature is lower than 3.9.
TIME SETTING In normal time mode, press and hold MODE button for 3 seconds, the digits begin to flash. Press or to set the clock by sequence to the desired year month date weekday language 12 or 24 hour hour minute exit. Press or for advancing/ backwarding by one step per second; press and hold or for fast advancing/ backwarding by eight steps per second. Press MODE to confirm present item and proceed to next. If there is no operation in 20 seconds, it will quit setting. While setting the language of weekday, the sequence is English German French Italian Dutch Spanish Danish. 7 LANGUAGES WEEKDAY DISPLAY Language German English Italian French Dutch Spanish Danish GER ENG ITA FRE DUT SPA DAN SUNDAY SON SUN DOM DIM ZON DOM SON MONDAY MON MON LUN LUN MAA LUN MAN TUESDAY DIE TUE MAR MAR DIN MAR TIR WEDNESDAY MIT WED MER MER WOE MIE ONS THURSDAY DON THU GIO JEU DON JUE TOR FRIDAY FRE FRI VEN VEN VRI VIE FRE SATURDAY SAM SAT SAB SAM ZAT SAB LOR ALARM SETTING & SNOOZE FUNCTION In normal time mode, press MODE once to switch to AL1 or AL2, then press and hold MODE for 3 seconds, the alarm time begins flashing. Choose the alarm mode between (Monday to Friday) and ( (Saturday and Sunday). Press or to set the alarm to the desired hour and minute. Press or for advancing/ backwarding by one step per second; press and hold or for fast advancing/ backwarding by eight steps per second. While setting, press MODE to confirm present item and proceed to next. If there is no operation in 20 seconds, it will quit setting. To turn on or off the alarm, press MODE again to switch to AL1 or AL2 preset alarm time and press ; when the alarm is on, the alarm symbol or appears or appear. The alarm sound lasts 2 minutes. When it sounds, press for 5 minutes snooze; press any other button to stop alarm or quit snooze.
MOON PHASE PRECAUTIONS 1. Do not clean any part of the product with benzene, thinner or other solvent chemicals. When necessary, clean it with a soft cloth. 2. Never immerse the product in water. This will damage the product. 3. Do not subject the product to extreme force, shock, or fluctuations in temperature or humidity. 4. Do not tamper with the internal components. 5. Do not mix new and old batteries or batteries of different types. 6. Do not mix alkaline, standard or rechargeable batteries with this product. 7. Remove the batteries if storing this product for a long period of time. 8. Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.