ICP Test Report Certification Packet

Similar documents
ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report. As per applicant s request

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

MATERIAL DECLARATION & RoHS REPORT

ICP Test Report Certification Packet

Test Report. Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

TEST REPORT NUMBER: SHAH DATE: AUG 18, 2008 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

TEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

ICP Test Report Certification Packet

TEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

ICP Test Report Certification Packet


ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report Number: SHAH Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Certificate of non-use of The Controlled Substances

Certificate of non-use of The Controlled Substances

TEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:

ICP Test Report Certification Packet

ICP Test Report Certification Packet

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

Certificate of non-use of The Controlled Substances

TEST REPORT. : The following submitted sample(s) said to be:-

TEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5

Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong

APPLICANT: CACTUS TECHNOLOGIES LTD DATE : JUL 25, 2007 SUITE /F BILLION TRADE CENTER 31 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG

: DAM1-125,DAM1-160,DAM1-400,DAM1-630,DAM1-800, DAM1-1600

ICP Test Report Certification Packet

ICP Test Report Certification Packet

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

ICP Test Report Certification Packet

ICP Test Report Certification Packet

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

ICP Test Report Certification Packet

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

ICP Test Report Certification Packet

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

ICP Test Report Certification Packet

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

TEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

ICP Test Report Certification Packet

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

ICP Test Report Certification Packet

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

ICP Test Report Certification Packet

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Certificate of non-use of The Controlled Substances

ICP Test Report Certification Packet

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No Date : 27/NOV/2017 Page 1 of 5

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

ICP Test Report Certification Packet

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

ICP Test Report Certification Packet

Test Report No. CTSSA/13164/14 Date: 11/07/2014 Page: 1 of 10 CTS Ref. CTSSA/14/2009/Redring

Test Report. Report No. SCL03H Page 1 of 7

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Transcription:

ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Omni Block Fuseholder Product #: 520 OMNI Block series Issue Date: April 14, 2014 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: [Global EHS Engineer] (1) Parts, sub-materials and unit parts This document covers the Fuse Clips RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: 1 Decemeber 01, 2005 Littelfuse, Inc. Page 1

Table 1: List of Raw Materials covered by this report ICP ID Raw Material Part Number Raw Material Description Page(s) ICP-050 057259 Base 3-12 ICP-0639 057256 Base 13-22 ICP-0988 048xxx Base brass strip of 111509 clip 23-28 ICP-0214 010113 Tin plating of 111509 clip 29-34 ICP-0215 010104 Nickel Plating of 111509 clip 35-40 2

Test Report Number : TWNC00297541 Applicant: Littelfuse, S.A. de C.V. Date : Feb 06, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : FUSEHOLDER BODY Part Number : 057259 Date Sample Received : Jan 30, 2013 Date Test Started : Jan 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0297541* Page 1 of 10

Number : TWNC00297541 (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Black RL plastic Heavy Metal Cadmium (Cd) Content ppm With reference to IEC 62321: 2008, by microwave digestion and ND 2 determined by ICP-OES. Lead (Pb) Content ppm With reference to IEC 62321: 2008, by microwave digestion and ND 2 determined by ICP-OES. Mercury (Hg) Content ppm With reference to IEC 62321: 2008, by microwave digestion and ND 2 determined by ICP-OES. Chromium VI (Cr 6+ ) Content ppm With reference to IEC 62321: 2008, by alkaline digestion and ND 1 determined by UV-Vis Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ppm ND 5 Dibrominated Biphenyls (DiBB) ppm ND 5 Tribrominated Biphenyls (TriBB) ppm ND 5 Tetrabrominated Biphenyls ppm With reference to IEC ND 5 (TetraBB) 62321: 2008, by solvent Pentabrominated Biphenyls ppm extraction and ND 5 (PentaBB) determined by GC-MS and Hexabrominated Biphenyls ppm further HPLC-DAD ND 5 (HexaBB) confirmation when Heptabrominated Biphenyls ppm necessary. ND 5 (HeptaBB) Octabrominated Biphenyls (OctaBB) ppm ND 5 Nonabrominated Biphenyls (NonaBB) ppm ND 5 Decabrominated Biphenyl (DecaBB) ppm ND 5 *THJ0297541* Page 2 of 10

Number : TWNC00297541 (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Black plastic RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ppm ND 5 Dibrominated Diphenyl Ethers (DiBDE) ppm ND 5 Tribrominated Diphenyl Ethers (TriBDE) ppm ND 5 Tetrabrominated Diphenyl ppm With reference to IEC ND 5 Ethers (TetraBDE) 62321: 2008, by solvent Pentabrominated Diphenyl ppm extraction and ND 5 Ethers (PentaBDE) determined by GC-MS and Hexabrominated Diphenyl Ethers ppm further HPLC-DAD ND 5 (HexaBDE) confirmation when Heptabrominated Diphenyl ppm necessary. ND 5 Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) ppm ND 5 Nonabrominated Diphenyl Ethers (NonaBDE) ppm ND 5 Decabrominated Diphenyl Ether (DecaBDE) ppm ND 5 Phthalates Di(2-ethylhexyl) Phthalate With reference to EN ppm (DEHP) 14372: 2004, by solvent ND 50 Dibutyl Phthalate (DBP) ppm extraction and ND 50 Benzyl Butyl Phthalate (BBP) ppm determined by GC-MS. ND 50 Halogen Content Fluorine (F) ppm With reference to EN 1741 50 Chlorine (Cl) ppm 14582:2007 by ND 50 calorimetric bomb with Bromine (Br) ppm oxygen and determined 60563 50 Iodine (I) ppm by Ion Chromatograph. ND 50 Others With reference to USEPA Hexabromo cyclododecane 3540C, by solvent ppm (HBCDD) extraction and determined by GC-MS. ND 10 *THJ0297541* Page 3 of 10

Number : TWNC00297541 Remarks: ppm = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jan 30, 2013 Test Period : Jan 30, 2013 to Feb 05, 2013 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0297541* Page 4 of 10

Number : TWNC00297541 (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MSD Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0297541* Page 5 of 10

Number : TWNC00297541 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0297541* Page 6 of 10

Number : TWNC00297541 (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0297541* Page 7 of 10

Number : TWNC00297541 (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0297541* Page 8 of 10

Number : TWNC00297541 (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0297541* Page 9 of 10

Number : TWNC00297541 Photo *THJ0297541* Page 10 of 10

Test Report Number : TWNC00297542 Applicant: Littelfuse, S.A. de C.V. Date : Feb 06, 2013 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : KNOB SCREW SLOT Part Number : 057256 Date Sample Received : Jan 30, 2013 Date Test Started : Jan 30, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0297542* Page 1 of 10

Number : TWNC00297542 (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Gray RL plastic Heavy Metal Cadmium (Cd) Content ppm With reference to IEC 62321: 2008, by microwave digestion and ND 2 determined by ICP-OES. Lead (Pb) Content ppm With reference to IEC 62321: 2008, by microwave digestion and ND 2 determined by ICP-OES. Mercury (Hg) Content ppm With reference to IEC 62321: 2008, by microwave digestion and ND 2 determined by ICP-OES. Chromium VI (Cr 6+ ) Content ppm With reference to IEC 62321: 2008, by alkaline digestion and ND 1 determined by UV-Vis Spectrophotometer. Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ppm ND 5 Dibrominated Biphenyls (DiBB) ppm ND 5 Tribrominated Biphenyls (TriBB) ppm ND 5 Tetrabrominated Biphenyls ppm With reference to IEC ND 5 (TetraBB) 62321: 2008, by solvent Pentabrominated Biphenyls ppm extraction and ND 5 (PentaBB) determined by GC-MS and Hexabrominated Biphenyls ppm further HPLC-DAD ND 5 (HexaBB) confirmation when Heptabrominated Biphenyls ppm necessary. ND 5 (HeptaBB) Octabrominated Biphenyls (OctaBB) ppm ND 5 Nonabrominated Biphenyls (NonaBB) ppm ND 5 Decabrominated Biphenyl (DecaBB) ppm ND 5 *THJ0297542* Page 2 of 10

Number : TWNC00297542 (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Gray plastic RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ppm ND 5 Dibrominated Diphenyl Ethers (DiBDE) ppm ND 5 Tribrominated Diphenyl Ethers (TriBDE) ppm ND 5 Tetrabrominated Diphenyl ppm With reference to IEC ND 5 Ethers (TetraBDE) 62321: 2008, by solvent Pentabrominated Diphenyl ppm extraction and ND 5 Ethers (PentaBDE) determined by GC-MS and Hexabrominated Diphenyl Ethers ppm further HPLC-DAD ND 5 (HexaBDE) confirmation when Heptabrominated Diphenyl ppm necessary. ND 5 Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) ppm ND 5 Nonabrominated Diphenyl Ethers (NonaBDE) ppm ND 5 Decabrominated Diphenyl Ether (DecaBDE) ppm ND 5 Phthalates Di(2-ethylhexyl) Phthalate With reference to EN ppm (DEHP) 14372: 2004, by solvent ND 50 Dibutyl Phthalate (DBP) ppm extraction and ND 50 Benzyl Butyl Phthalate (BBP) ppm determined by GC-MS. ND 50 Halogen Content Fluorine (F) ppm With reference to EN 2054 50 Chlorine (Cl) ppm 14582:2007 by ND 50 calorimetric bomb with Bromine (Br) ppm oxygen and determined 42356 50 Iodine (I) ppm by Ion Chromatograph. ND 50 Others With reference to USEPA Hexabromo cyclododecane 3540C, by solvent ppm (HBCDD) extraction and determined by GC-MS. ND 10 *THJ0297542* Page 3 of 10

Number : TWNC00297542 Remarks: ppm = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jan 30, 2013 Test Period : Jan 30, 2013 to Feb 05, 2013 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0297542* Page 4 of 10

Number : TWNC00297542 (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MSD Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0297542* Page 5 of 10

Number : TWNC00297542 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0297542* Page 6 of 10

Number : TWNC00297542 (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0297542* Page 7 of 10

Number : TWNC00297542 (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0297542* Page 8 of 10

Number : TWNC00297542 (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0297542* Page 9 of 10

Number : TWNC00297542 Photo *THJ0297542* Page 10 of 10

Test Report Number : TWNC00290372 Applicant: Littelfuse, S.A. de C.V. Date : Dec 18, 2012 Blvd. Fausto Z. Martinez #1800 Col. Magisterio Seccion 38 C.P. 26070 Piedra Negras, Coahuila, Mexico Sample Description: One (1) group of submitted samples said to be : Part Description : BRASS STRIP Part Number : 048290 Date Sample Received : Dec 11, 2012 Date Test Started : Dec 12, 2012 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0290372* Page 1 of 6

Number : TWNC00290372 (Ⅰ) Test Result Summary : Heavy Metal Test Item Result (ppm) Golden metal Cadmium (Cd) content ND Lead (Pb) content 17 Mercury (Hg) content ND Chromium VI (Cr 6+ ) content (mg/kg with 50cm 2 ) Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm 2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received : Dec 11, 2012 Test Period : Dec 12, 2012 To Dec 13, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0290372* Page 2 of 6

Number : TWNC00290372 (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 0.02 mg/kg with 50cm 2 *THJ0290372* Page 3 of 6

Number : TWNC00290372 (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ0290372* Page 4 of 6

Number : TWNC00290372 Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0290372* Page 5 of 6

Number : TWNC00290372 Photo *THJ0290372* Page 6 of 6

Test Report Number : TWNC00340093 Applicant: Littelfuse Philippines Inc. Date : Nov 07, 2013 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Tin Anode Part Number : 010113 Date Sample Received : Oct 30, 2013 Date Test Started : Oct 31, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0340093* Page 1 of 6

Test Report Number: TWNC00340093 Test Result Summary: Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Test Item Unit Test Method Chromium VI (Cr 6+ ) content ppm ppm ppm mg/kg with 50 cm 2 With reference to IEC 62321-5: 2013, by microwave or acid digestion and determined by ICP-OES. With reference to IEC 62321-5: 2013, by microwave or acid digestion and determined by ICP-OES. With reference to IEC 62321-4: 2013, by microwave or acid digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. Result Silvery metal RL ND 2 108 2 ND 2 Negative 0.02 Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, quantitation limit of analyte in sample mg/kg with 50cm 2 = Milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of test. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Oct 30, 2013 Test Period : Oct 31, 2013 to Nov 07, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100ppm) Lead (Pb) content 0.1% (1000ppm) Mercury (Hg) content 0.1% (1000ppm) Chromium VI (Cr 6+ ) content 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0340093* Page 2 of 6

Test Report Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:Cd/Pb: IEC 62321-5:2013; Hg: IEC 62321-4:2013; Chromium (VI): IEC 62321:2008 Number: TWNC00340093 Sampling Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 By spot test Weigh sample and add alkaline solution Confirm the tested samples are totally dissolved Negative *2 Get 50cm 2 sample Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0340093* Page 3 of 6

Test Report Number: TWNC00340093 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0340093* Page 4 of 6

Number: TWNC00340093 *THJ0340093* Page 5 of 6

Number: TWNC00340093 *THJ0340093* Page 6 of 6

Test Report Number : TWNC00340094 Applicant: Littelfuse Philippines Inc. Date : Nov 07, 2013 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Nickel Anode Part Number : 010104 Date Sample Received : Oct 30, 2013 Date Test Started : Oct 31, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0340094* Page 1 of 6

Test Report Number: TWNC00340094 Test Result Summary: Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Test Item Unit Test Method Chromium VI (Cr 6+ ) content ppm ppm ppm mg/kg with 50 cm 2 With reference to IEC 62321-5: 2013, by microwave or acid digestion and determined by ICP-OES. With reference to IEC 62321-5: 2013, by microwave or acid digestion and determined by ICP-OES. With reference to IEC 62321-4: 2013, by microwave or acid digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. Result Silvery metal RL ND 2 ND 2 ND 2 Negative(#) 0.02 Remarks: ppm = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of test # = Due to the insufficient sample area, reduced total sample surface of 10 cm 2 was used and the dilution factor was adjusted accordingly. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Oct 30, 2013 Test Period : Oct 31, 2013 to Nov 07, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100ppm) Lead (Pb) content 0.1% (1000ppm) Mercury (Hg) content 0.1% (1000ppm) Chromium VI (Cr 6+ ) content 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0340094* Page 2 of 6

Test Report Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:Cd/Pb: IEC 62321-5:2013; Hg: IEC 62321-4:2013; Chromium (VI): IEC 62321:2008 Number: TWNC00340094 Sampling Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 By spot test Weigh sample and add alkaline solution Confirm the tested samples are totally dissolved Negative *2 Get 50cm 2 sample Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0340094* Page 3 of 6

Test Report Number: TWNC00340094 End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for anyparticular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and onlyaccepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes nowarranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conductthe Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0340094* Page 4 of 6

Number: TWNC00340094 *THJ0340094* Page 5 of 6