IT Series Infrared thermometer Using manual Wuhan Dikai Optic-electronic Technology Co., ltd
Before using the thermometer, please read the manual carefully, for the purpose of better exert its function and prolong service life. Please keep the manual carefully for consult later. If appear these problems: Appearing the abnormality, please turn off the power, and contact us in time. That take apart yourself will not have after service and won t have servicing for free If this manual altered, forgive us won t inform you
Catalogue 1 Summary 2 Technology parameter 3 Figure structure 4 Model naming and selection 5 Usages 6 Maintenance and molar assurance 7 Notice 8 Selection of infrared thermometer Attach: the emissivity list of familiar materials on temperature measuring
1 Summary IT series infrared thermometer has the same optical axis on the measurement and collimation. For satisfying the different requirements of customers, the meter can be segmented between 300 and 3000 discretionally. Because of using SMT on the part of circuit transformation and MCU on the part of data processing, the accuracy and Repeatability can be guarantee better. Especially, the meter is suit to locomotors objects, electriferous conductors vacuum environment or other objects that have special request to be non-contact measured. The measure is without influence to the temperature field. The product can be applied to foundry, powder metallurgy, steel rolling, power supply, chemical industry, glass, ceramic production, heat treatment, intermediate/high frequency induction heating, wire production, sinter, hot-pressing sinter, jointing industry and so on. 2 Technology parameter Measuring range 300 ~3000 (subsection) Measuring accuracy ±0.5%,±0.2%(Reading) Measuring distance 0.2m~5m Mini object φ2mm(298mm),φ0.5mm (80mm) Distance coefficient 145:1,160:1 Repeatability ±0.2 Response time <10 ms Resolution 0.5 Sighting system Laser sighting Sensing head size φ50 100mm Emissivity 1.0,0.9,0.8,0.7 (IT-6) 0.10~1.00 (IT-8) Output 0~5V,4~20mA Power ±12VDC Weight 0.5kg Working environment 0 ~60,Humidity<90% Installation 1/4 inch bolt Communication RS485(IT-8)
3 Figure structure IT-6 unit:mm IT-6 Back cover : IT-8 unit:mm
IT-8 Back cover: Key-press definition: SET key: using for parameter setting, on the state of waiting or working, press the key for 5 sec, enter the state of parameter setting, on the course of parameter setting, press the key for 5 sec, back to the state of temperature displaying. Without any action for 15 min, the display will shut down automatically. On the state of blank screen, pressing the key can activate the temperature display. key:on the state of parameter, using the key for moving radix point, meanwhile, the position of radix point effect. key: Using for program the position of selected. Parameter setting manual table Parameter Meaning Range Default E1 Emissivity 1 0.01~1.00 1.00 E2 Emissivity 2 0.01~1.00(ITW only) 1.00 AHd Peak value 0~120 sec 0 keeping time defd Difference value 0~120 sec 0 keeping time CoEF Filter coefficient 0~20 0 Ad Interface address 1~100 1 rad Measuring mode 0:Continious measuring;1:peak measuring ;2:Difference measuring 0 4 Model naming and selection (1)Model naming IT X X X X English Letter output sorts V:0~5V;I:4~20mA Number Temperature range 1: 400 ~1200 Number Accuracy level 1:0.5 level Number Series code 6: no laser collimation; 8: laser collimation English abbreviate(infrared-thermometer)
express:lentoid infrared thermometer Example:IT 612V means:no laser collimation 0.5 level 800 ~2500 output 0~5V lentoid infrared thermometer (2)Selective list Model Manual Remark IT- Infrared English abbreviate 6 Ordinary Sort Emissivity can be adjusted 8 Enhanced peak value can be kept 0 1 level(fs%1) Tiptop 0.2 level(fs% 0.2) Precision 1 0.5 level (FS% 0.5) 0 300~800 1 400~1200 2 500~1400 Can be disjoined at will Range( ) 3 600~1400 between 300~3000 4 800~1800 5 800~2500 6 1000~3000 V 0~5VDC Output I 4~20mA Communication c RS485/RS232 interface 5 Usages (1) Installation:fixing by the 1/4 inch bolt (2) Derivative wire defined: Derivative wire Link Derivative defined spinouts wire color Simulate output RS485 1 Red +12V +12V 2 Blue -12V -12V 3 Black Terra terra 4 Yellow Output A 5 Green B Shielded wire link to the shell of the meter, or can be linked to the earth of the equipment. When it is unable to link, can be linked to the terra of power
(3)Output selection Simulate signal output:0~5vdc 4~20mA RS485(IT-8) Serial interface s usage: The sending mode of serial interface is simplex system, speed: 9600 baud When process controlling or long distance communicating,rs485 serial interface It need the RS485 RS232 conversion machine when need to communicate to calculator 6 Maintenance and quality guarantee (1)In the normal conditions, the thermometer need not special maintenance, keep off dampness please. And clean the lens surface of the thermometer regularly (using lens paper or soft cloth, wipe carefully and do not hurt the lens); (2) When the thermometer is not used, cut off the power and cover the lens saving in the dry and clean circumstances (3) The malfunction causing by quality problem of products,free repair within 12 month after leave the factory Repair lifetime 7 Notices (1) When setup the thermometer,the light axis must be vertical to the object, otherwise will causing measuring error (2) The effective distance of laser aim is no more than0.3m (3) The thermometer has good response speed and good sensitivity, when the heat source (object)is instable,it s normal that the display meter of thermometer will move up and down follow; (4) The thermometer needs fixed, avoiding vibration 8 Selection of infrared thermometer Confirming the range of measuring: The range of measuring is one of the thermometer s most important capability quota, every type of thermometer has each special range of temperature measuring. Narrower the thermometer s range is, the monitor temperature output signal resolution is higher, and the reliability is resolved easily. That the range is too wide will lower the accuracy of temperature measuring. Size of object: According to the principle of infrared thermometer, it s divided into homochrome infrared thermometer and bicolor infrared thermometer When using homochrome infrared thermometer, it s better that the area of object exceed the sight-field by 50% And to the small and moving or vibrant object, bicolor infrared thermometer is the best choice.
Distance coefficient(optical resolution):distance coefficient is the ratio of D (the distance between head and the object) and the diameter of the object. If the distance to the object is far, and the object is small, you should choose the high distance coefficient thermometer, on the other hand, you should choose low distance coefficient thermometer. Confirming response time::response time express the response speed that the infrared thermometer responses to the temperature being measured, defined as the time needed that arrive 95% of the last reading power It has relations with photo-electric detector, signal process circuit and the time constant of display system If the speed of moving object is very quick and measuring the object that heated quickly, you should choose the high-speed response infrared thermometer, otherwise, it won t achieve the enough signal response speed and will lower the measuring accuracy. But not all of applications need quick response infrared thermometer. To the quiescent object or the object that on the course of heat has heat inertia, the response time can be loosen. Therefore, the infrared thermometer s selection must be adapted to the state of the object. Confirming circumstance:the circumstance of the thermometer will affect the measuring result a lot., so the problem should be considered and be solved properly, otherwise, this will affect the accuracy of thermometer even damage the thermometer On the conditions of high temperature, existing dust, smoke and steam, you should choose the accessories supplied by factory such as protect cover, water-cool, air-cool, air-cool system, air-blow etc These accessories can solve circumstance influence effectively and protect the thermometer, realizing temperature measuring exactly. When choosing accessory, you should request standard service as far as possible to reduce the cost of setup. It would be the best to choose bicolor infrared thermometer on the conditions of smoke, dust or other situation that grain will lower the power of measuring signal. Also, on the conditions of noisy, electromagnetic field, shaking or the circumstance that difficult to be closed or other bad conditions, bicolor infrared thermometer is the best. On the conditions of bad and complex, choosing the system that the thermometer head and the monitor is divided is convenience to setup and equip. You should choose the signal modality that matching the control equipment actual Emissivity of material(emissivity):when there are many kinds of material measured and their emissivity is different, it s better to choose the infrared thermometer that the emissivity is adjustable.
Attach: the emissivity list of familiar materials on temperature measuring Material Emissivity Material Emissivity polished 0.04~ 0.06 Asbestos 0.95 Aluminum Anode oxidized 0.55 Asphaltum 0.95 Oxidized 0.11~ 0.70~ Paper 0.25 0.90 Polished 0.02~ 0.05 Concrete 0.92 Brass Unoxidized 0.20 Water icewater 0.95 Oxidized 0.6~0.88 Gypsum 0.80~ 0.90 Polished 0.10 Skin 0.98 board Steel 0.40~ Slab Carbon 0.95 0.60 Nonmetal 0.80~ Metal Tungsten 0.05 Paint 0.98 Electroplate 0.90~ 0.05 Soil polished 0.98 Nickel Electroplate unpolished 0.11 Rubber 0.95 Oxidized 0.30~ 0.50 Ceramic 0.93 Polished 0.05~ 0.07 Wood 0.93 plumbum Roughened 0.40 Ice 0.98 Oxidized 0.30~ 0.60 Fiberboard 0.95 Unoxidized 0.05 Lampblack 0.96 Zinc Galvanized iron plate 0.25 Sand 0.90