Making Sense of Differences in LCMS Data: Integrated Tools

Similar documents
MassHunter TOF/QTOF Users Meeting

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

MassHunter Software Overview

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Agilent All Ions MS/MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Die Nadel im Heuhaufen

QTOF Small Molecule Applications Update. April 10 th, David A. Weil. Application Scientist, Schaumburg, IL

Application Note. Authors. Abstract. Introduction. Environmental

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

The new Water Screening PCDL

Computer-assisted analysis of complex natural product extracts

Agilent MassHunter Quantitative Data Analysis

Agilent MassHunter Quantitative Data Analysis

Extend Your Metabolomics Insight!

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

David A. Weil*, Zoltan Timar and Michael Zumwalt. Agilent Technologies. Schaumburg, IL/ Boulder, CO. Impurity Profiling 2008

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

WADA Technical Document TD2003IDCR

Application Note. Edgar Naegele. Abstract

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Agilent Technologies LCMS Portfolio

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Welcome! Course 7: Concepts for LC-MS

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Identifying Disinfection Byproducts in Treated Water

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Multi-residue analysis of pesticides by GC-HRMS

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

WADA Technical Document TD2015IDCR

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Agilent G3212 GC-APCI Source

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Application Note. Edgar Naegele. Abstract

Workflow Using Hyphenated Mass Spectrometry Techniques

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Compounding insights Thermo Scientific Compound Discoverer Software

Agilent ESI and APCI sources: for polar to non-polar compounds

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

MetWorks Metabolite Identification Software

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

WALKUP LC/MS FOR PHARMACEUTICAL R&D

LC-MS Based Metabolomics

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Impurities Sources, Detection and Measurement HPLC-MS Analyses. Dr Courtney Milner Chemical Analysis

Cerno Application Note Extending the Limits of Mass Spectrometry

Automated and accurate component detection using reference mass spectra

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

MS Interpretation I. Identification of the Molecular Ion

Analysis of Polar Metabolites using Mass Spectrometry

Construction and Use of API Single- Quadrupole MS Spectral Libraries.

Information Dependent Acquisition (IDA) 1

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

SIFT-MS. technology overview

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

LC-MS. Pre-processing (xcms) W4M Core Team. 22/09/2015 v 1.0.0

Accurate Mass Analysis of Hydraulic Fracturing Waters

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

Highly Sensitive and Rugged GC/MS/MS Tool

Mass Spectrometry. Electron Ionization and Chemical Ionization

Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

Finnigan LCQ Advantage MAX

ProMass Deconvolution User Training. Novatia LLC January, 2013

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Metabolomics Workflow. Discovery Workflow Guide

QTOF-based proteomics and metabolomics for the agro-food chain.

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Introduction to GC/MS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Theory and Practical Consequences.

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

FUTURE CONFIRMATORY CRITERIA

Transcription:

Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008

How Clean is our Water?... Page 2

Chemical Residue Analysis.... From the headlines.. PFOA/PFOS Persistent Chemical Fungicides/Pesticides PPCP Steroids and Antibiotics Residuals in Beverages Page 3

Challenges in Differential Analysis Sample Preparation: Extraction Efficiency Separation Methods: Sharper the Better Ionization Efficiency Effects ESI preferential Ionization of polar/acid/base compounds APCI for non-polar compounds Polarity Effects Ionization Suppression: Matrix Effects Mass Spectrometry Sensitivity: Detection vs Relevant Data Analysis: Show me the Data Page 4

Agilent s Solution for Differential Analysis Objective: Detection - ID low-level Impurities in Drugs, Chemical Residues in Water, Food and Carbonated Beverages Volatile Residues GC/MS Analysis Data Analysis Sample Preparation Separations Targeted Quant QQQ Agilent s New SPE Products Non-Volatile Residues LC/MS Analysis Non-Targeted TOF/QTOF Impurity ID Profiling Data Analysis Page 5

The Match Game. Choosing The Mass Spectrometer for the Task Sensitivity, Selectivity, Identification.. Unknown Identification Accurate Mass MS, MSMS MS/MS Sensitivity Unknown Identification Impurity Profiling by Accurate Mass Target Analysis Enhanced Sensitivity by MS/MS Page 6

Agilent Suite of MassHunter Products Qual Quant Profiler MetID Page 7

MassHunter QUAL MSD, QQQ, TOF, QTOF Data Navigator Method Editor Method Parameters Page 8

Qualitative Analysis: Compound Centric Data Mining and Navigation Several automated algorithms to find compounds or sample components from LC/MS and LC/MS/MS datasets Chromatogram Linking of panes for easier browsing and navigation Navigation Tree Spectrum Page 9

Qualitative Analysis: Molecular Feature Extraction Compound Chromatogram List of Compounds Compound Spectrum Page 10

How To Determine Complexity of Sample/Matrix Acquire MS or AutoMSMS Modes Base Peak Chromatogram Exclude Major Component Find Compounds by Molecular Feature Extraction x10 6 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 + BPC(150.00000-800.00000) Scan CoffeeSpiked12.d 1 1 x10 6 1.4 1.2 1 0.8 0.6 0.4 0.2 + BPC(150.00000-800.00000 [-1]) Scan CoffeeSpiked12.d 1 1 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 Counts vs. Acquisition Time (min) Base Peak Chromatogram with Exclude m/z 195.09145 +/- 100 ppm Page 11

Molecular Feature Extraction (MFE) Automated Data Reduction Software Finds Features in TOF/QTOF Data 3D 3D Plot Plot Before No Coeluting Features Background Original TIC Processed TIC Data Reduced sum intensities of isotopes, adducts, clusters and multiply charges ions together. Page 12

Processing large amount of data with MFE Display filtering: - S/N > 2 -m/z150 to 800 - [M+Na] and [M+NH 4 ] Adducts - At least 2 ions - Relative intensity > 0.01% 5131 features Processed TIC Intensity (10^6) 15 10 5 Original TIC TIC Intensity (10^6) 15 Processed TIC 10 5 0 min 2 4 6 8 10 12 14 min 0 2 4 6 8 10 12 14 Page 13

In MassHunter Qual Select Find by Molecular Feature Page 14

Method Editor: Parameters for Molecular Feature Display Filters Page 15

Mass Defect Filtering Page 16

Executed Compound Table Page 17

Find Compounds by Molecular Feature x10 6 Cpd 279:+ ECC Scan CoffeeSpiked12.d 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 Counts vs. Acquisition Time (min) Over 280 Compounds Found in Coffee Spiked with Pesticide Page 18

Prednisolone: C 21 H 28 O 5 360.193674 OH CH 3 O CHOH 3 O O CH 3 O 2 year old Suspension Page 19

Sequential Neutral Water Losses Detected x10 5 + ECC Scan Prednisolone0002.d 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 13.421 23081.8 0.1 0 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 Counts vs. Acquisition Time (min) Page 20

12 Potential Degradation Products in Prenisolone CH 2 O Loss -H 2, -H 2 O, -CO 2 H 2, +H 2, +CH 4 +H 2 -O, Page 21

Molecular Formula Generation.. Technical Overview 5989-7409EN Page 22

Generate Formulas Parameters Page 23

Theoretical Isotope Pattern Page 24

Accurate Mass of Compounds Page 25

Identify Compounds by Database Searching Search database by mass or by molecular formula Select either exact mass or Personal Metlin database Page 26

Automated Compound Search Metlin Database Page 27

Mass Profiling Version 2.0 Processed Processed TIC Processed TIC Group TIC A (Impure) Processed Processed TIC Processed TIC Group B TIC (Control) Aligns Data RT, Mass, Abundance What s Changed? Mass/RT >2 Fold Change What s All Unique!! Data RT/Mass Impurity Control Page 28

How to Create a Project Select 2 Groups for Differential Select 1 Group for Concentration Change Need at least 3 replicates Page 29

Develop a Method Select Retention Time and Mass Range For Small Molecules Exclude Multiply Charged Species Set Relative Intensity Limit Mass Defect Option Special Masses: Exclude ions present in blank Display only Targeted Ions Page 30

Results Filters Application of Results Filters will reduce the number of features displayed in the graph To Display only Features with Greater than 2 fold change set Min Log2 value to 1.0 Relative Frequency filter by presence in samples. Exclude Saturated Features Page 31

Multiple Display Options Mass vs RT (Average of Features) Page 32

Differential Display by Retention Time Page 33

Unique Features.. Page 34

Single Group Example: Compounds Spiked into Plant Extract Page 35

Feature Table Single Group Example For Single Group: Large SD of abundance indicates compounds that have concentrations that vary over the samples Page 36

Graphical Display of Concentration Change of Feature Change Plot Style to Colored by Feature Page 37

Abundance and Feature Details Page 38

Batch Chemical Composition and Database Search from Mass Profiler Page 39

Batch Molecular Formula Generation and Database Searching from Profiler Page 40

Web Searching of Compounds NIST, ChemIDPlus, PubChem, Page 41

MetID Software For Impurity Profiling Page 42

MassHunter Workstation - Metabolite ID Quickly Identify More Metabolites with Greater Confidence Powerful Sample-Control Comparison Algorithm based on Molecular Feature Extraction (MFE) Find Metabolites via Mass Defect Filter Empirical Formula Generation supports MS/MS data Confirm Metabolites via Noviatia Autoshift of MS/MS data Applications beyond Metabolites Impurity and Environment Profiling Page 43

Metabolite Table w/ Find + Confirm Results Metabolite Chros + Spectra Molecular Formula Generation MS and MSMS Data Page 44

Overview MetID 1. Parent Compound: MW, Formula and Structure 2. Transformations: List Proposed Degradation Products 3. Identification Criteria: Vary Importance of Tests 4. Find Compounds by MFE: Molecular Feature Extraction 5. Find Compounds by AutoMSMS: For MSMS data 6. Sample Comparison: Mass Profiler What is Different 7. Isotope Pattern Filtering: Best for Halogenated Species 8. Mass Defect Filtering: From Proposed Compounds 9. EIC Generation: Confirms Presence of Compounds Page 45

Page 46

Method Input Parent Compound Propose Degradation Products Page 47

Proposed Degradation Products Qualified by Mass Defect and Isotope Pattern Let s Determine Composition of MW 411 Page 48

Accurate Mass Generates Composition Acid Hydrolysis (H 2 O+CO 2 H-OH) Accurate Mass of Fragments Ions Page 49

Overlay MSMS Spectrum Parent/Product Page 50

3D of MSMS Spectra Fragmentation Pattern Page 51

METLIN Personal Database Search Capabilities Manual searches Search on neutral or charged monoisotopic mass User-specified search tolerance Optionally restrict by retention time Molecular formula Compound name Retention time (user defined) Batch and manual mass searches from Agilent products GeneSpring MS MassHunter Qual Mass Profiler Page 52

Personal Metlin Database Page 53

METLIN Personal Database Initial View User search mode Page 54

METLIN Manual Single Mass Search Single mass search settings Active metabolite structure Hyperlinks to Metabolite websites Metabolite search results Page 55

METLIN Batch Search Load file for batch search Active metabolite structure Active mass Active mass search results Page 56

METLIN Batch Summary Active metabolite structure Batch summary best metabolite match Exportable list of best metabolite search results Page 57

Creating a New METLIN Database METLIN is read only and can not be changed Create a new personal database from METLIN Page 58

Edit Metabolite Database Update Entry Add retention time to existing metabolite Page 59

METLIN Mass Search With Retention Time Adds Specificity Only 1 metabolite instead of 3!!!! Adding retention time eliminates isobaric metabolites Page 60

Edit Metabolite Database New Entry Select add new then type new metabolite information Page 61

METLIN Search from Mass Hunter Qual Identify compounds: search database Specify the METLIN database Set search parameters Manual search options Select ion in spectra Select MFE compound(s) Batch search Automate by Find and Identify Find compounds by MFE Search database Generate formula (optional) Name and CAS number Set Parameters Database and MFG results View detailed results Page 62

METLIN Searching From Mass Profiler Mass Profiler METLIN searching is virtually the same as METLIN Mass Profiler can optionally add MFG MFG is used to assist METLIN search METLIN results are exportable Database customization is done only in METLIN Retention time changes New compounds New database METLIN search integrated into Mass Profiler Page 63

Summary Accurate Mass and Reproducible Retention Time are Critical for Differential Analysis and Trace Level Impurity Detection Data Mining Software Tools Provide Unbiased Automated Data Analysis Feature Extraction: MassHunter Profiler: MetID: Find Compounds in Complex Matrix Differential Analysis Software Metabolite ID and Impurity Profiling Metlin Database: Personalize Destktop Database Searching Page 64

THANK YOU.. Page 65