model SKT05 SKT05L Toll Free: (855) IMPORTANT: Read Before Using IMPORTANT Lire avant usage IMPORTANTE: Leer antes de usar

Similar documents
Fig. 1. instrument is in the case

LT8-300LTU Owner s Guide

DWT-10 Instruction Manual

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

GT-510/510L series Instruction Manual

1 YEAR LIMITED WARRANTY TELESCOPES

Welcome to purchase and use our products and thank you for your confidence in our company s products!

Directions for use

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

STONEX ELECTRONIC THEODOLITE STT SERIES. Instruction Manual

22X Builder s Transit Level Model No Instruction Manual

22X Builder s Level Model No Instruction Manual

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

RP-100 TELESCOPE Instruction Manual

Automatic Level NP-732

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

product manual H-3220A Benkelman Beam

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)

x Builders Level Service Manual

CIV : THEODOLITE ADJUSTMENT

RP-200 TELESCOPE Instruction Manual

SURVEYING INSTRUMENTS DT7C DT20C. Electronic Digital Theodolite OPERATOR'S MANUAL

One-Year Limited Warranty

CASSINI CQR-120 OPERATING INSTRUCTIONS

FIELD GUIDE FOR HORUS SCOPES

EE 1/3.5х14 U EE 1/3.5х14 U

NEVER USE A TELESCOPE TO LOOK AT THE SUN DIRECTLY!

WHEN BRIGHTNESS COUNTS

Carlson CR Robotic/Reflectorless Total Station

Altazimuth Mount. Altazimuth Mount

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM

Digital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee

Instruction Manual. Kite-22 Camera Crane Starter Package (KITE-22-STARTER) Exclusive of Weights

Dual Red or Green Electronic Dot Sight Instruction Manual

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

5-25x56 PMII PSR Illuminated with Double Turn

ZOOM STEREO MICROSCOPE

LEAPERS, INC. RED/GREEN DOTS

C A S S I N I TRACKER

566/568. Infrared Thermometers. Getting Started

Quick Start Guide. The ieq30 Pro GoTo German Equatorial Mount #3000E

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

5-25x56 PMII PSR With Double Turn

10.3 Vertical reticle

Cleveland State University

DT220 DT520 DT520S DT520A DT520AS DT620 DT620S

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

Quick Start Guide. CEM25P Center Balanced GoTo Equatorial Mount Models: #7100P, #7102P

Quick Start Guide. CEM25 Center Balanced GoTo Equatorial Mount Models: #7100E, #7102E

Flexbar 6.3:1 MANUAL ZOOM STEREO MICROSCOPE. 250 Gibbs Road, Islandia, NY (P) (F)

Quick Start Guide. ZEQ25GT Center Balanced GoTo Equatorial Mount Models: #7100, #7101, #7102

AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130

Quick Start Guide. ZEQ25GT Balanced GoTo Equatorial Mount Models: #7100, #7101, #7102

Quick Start Guide. For SmartEQ TM Pro+ (#3200) Portable German Equatorial GOTO Mount

Instruction Manual Meade 70AZ-T 70mm Compact Refractor Telescope Meade Instruments Corporation

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

H050 E 97.1.DF.2. Automatic Levels AS-2 / AS-2C

Series. Quantum 100 Refractor (Equatorial Mount not included) INSTRUCTION MANUAL models s11160

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

CAUTION: BEFORE INSTALLATION, CONFIRM THAT THE CROSSBOW IS UNLOADED AND IS IN SAFE OPERATING CONDITION.

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

GY 301: Geomorphology Lab 5: Total Station Mapping Project

R-300 SERIES R-315(N)/R-325(N)/R-335(N) R-322(N)/R-323(N)/R-326. Electronic Total Station. Instruction Manual

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

THE LOSMANDY G-11 MOUNT

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

W-800 TOTAL STATION BASIC INSTRUCTION SERIES MANUAL W-821NX W-822NX W-823NX W-825NX W-835NX

Instruction Manual. Model #: (Reflector) Lit #: / 06-07

Total station LEICA TPS

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

Z650HR SERIES MANUAL ZOOM STEREO MICROSCOPE. 73 Mall Drive, Commack, NY (P) (F)

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

SURVEYING INSTRUMENTS LDT520 LDT520S. Laser Digital Theodolite. Class 3R Laser Product OPERATOR'S MANUAL

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patented ACSS.308/.223 HUD DMR Reticle. Advanced Combined Sighting System

HEAVY DUTY SWING-OUT VALVE

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

product manual H-4204 Proving Ring Penetrometer

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

???? The Vortex Crossfire II Riflescopes

R-1502N R-1503N R-1505N INSTRUCTION MANUAL

RP-300 TELESCOPE Instruction Manual

JC-1000 Instruction Manual

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

HEAVY DUTY SWING-OUT VALVE

Table of Contents. Specifications 1 Adjustments 2 Using the Reticle 8 Maintenance 16 Troubleshooting 18 SS Warranty 19

total station Instruction manual Basic Procedures

Quick Start Guide. The ieq45 Pro GoTo German Equatorial Mount #8000E, #8000EP and #8000E-AZ

Operating Manual 1.1-4x24 Zenith x24 Zenith

Transcription:

Operating / Safety Instructions Consignes de fonctionnement / sécurité Instrucciones de funcionamiento y seguridad IMPORTANT: Read Before Using IMPORTANT Lire avant usage IMPORTANTE: Leer antes de usar model SKT05 SKT05L Toll Free: (855) 354-9881 www.sitepro.us.com

GENERAL SAFETY RULES Working safely with this instrument is possible only when the operating and safety information are read completely and the instructions contained therein are strictly followed. The use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure. DO NOT aim the telescopic tube at the sun directly,which will do harm to eyes. DO NOT carry the instrument while attached to tripod. DO NOT place the instrument in the sun for a long periods of time. DO NOT disassemble the instrument or attempt to perform any internal servicing. Laser class is indicated on the instrument. Repair and servicing of this laser are to be performed only by SitePro or authorized service centers. When attaching the instrument to a tripod, make sure the instrument is securely fixed. The tripod leg clamps should be securely fastened. If not securely fastened or tightened, the main unit could fall off or the tripod could fall over. The instrument should not be stored or used in extreme temperature or during rapid temperature change. Store inside the carry case and place in a dry area not subject to vibration, dust or high moisture. If the storage temperature and ambient temperature for usage vary significantly, leave the laser in its case until it can adjust to the ambient temperature. The instrument should be transported or carried carefully to avoid impact or vibration. The instrument should be stored in the carry case and packed with cushioning material. Always handle the instrument with care. 2

FEATURES 1. Handle 2. Objective Lens 3. Collimator 4. Vertical Adjustment Knob 5. Horizontal Adjustment Knob 6. Focus Knob 7. Eyepiece Lens 8. Battery Compartment 9. Display 10. Instrument Leveling Screws 11. Optical Plummet (SKT05) 1 2 3 4 5 6 7 8 10 9 11 SKT05 Only www.sitepro.us.com 3

DISPLAY SYMBOLS AND KEY FUNCTIONS Display Icon Description % Vertical angle gradient percentage Angle unit (GON) Battery capacity Slope distance Horizontal distance Height difference Distance unit (meter) distance unit(foot) 4

Key Primary Function Other Function 1. Start to initial setting of instrument 2. Start to index error setting of instrument ON 3.Start to compensator setting of instrument Reticle, board illumination, for SKT05L: laser down centering start-up button and OFF Horizontal angle Return to zero Horizontal right and left angle choosing/gradient choosing Horizontal angle memory button 1. Start to initial setting of instrument 2. Start to index error setting of instrument 3. Start to compensator setting of instrument 1. Start to initial setting of instrument 2. Start to compensator setting of instrument 1. Start to initial setting of instrument 2. Start to compensator setting of instrument www.sitepro.us.com 5

INITIAL SETTING The instrument has many functions. In order to be appropriate to different observation, please do initial setting before observation. Setting Items Unit of angle setting: (degree) (cent) (second) (360 degrees one circle) GON (400G one circle) mil (6400mil one circle) Factory setting Vertical angle 0 way setting: horizontal: 0 degree (zenith distance :90 degree) zenith distance: 0 degree (horizontal: 90 degree) factory setting: zenith distance: 0 degree Power auto off function: 30 min or deactivate Factory setting: 30 mins Minimum unit of angle displayed: 1 or 5 Factory setting: 1 Vertical index zero compensation setting: Auto compensation or uncompensated Factory setting: Auto compensation Horizontal angle reading passes through 0, 90 m, 180, 270, with audible ON or OFF 6 Factory setting: No beeps

Setting method Press key to turn power on and hold it until all the symbols displayed,then loose the key. After three beeps, loose the key. The instrument will be into initial setting mode. Press key to move the cursor to the next figure. Press key to change the figure. When all the initial setting is finished, press [0SET] key to come back to measurement mode. Steps as follows: 1. Press key to turn power on,entering into initial setting status. 2. Buzzer prompt of horizontal angle position: NO BEEP - no buzzer prompt in horizontal angle, Press key and for choosing 90 BEEP - the horizontal angle is close to 0, 90, 180, 270, buzzer sound. 3. Unit of angle, Press key and for page turning. UNITA 360 UNITB 400G UNITC 6400mil 4. Vertical angle 0 position, Press key and for page turning. ZEN=0 zenith angle is 0 ZEN=90 zenith angle is 90 5. Auto power off time, Press key and for page turning. NO OFF non auto power off 30 OFF auto power off after 30 mins without any pressing www.sitepro.us.com 7

6. Minimum unit of angle displayed, Press key and key for page turning. DSP 1 mini display 1 DSP 5 mini display 5 7. Vertical compensator setting, Press key and key for page turning. VTILT ON turn on compensator VTILT OFF turn off compensator 8. When the initial setting is finished, the key must be pressed to confirm and save the setting. Otherwise, the setting will be the former setting before. PREPARATION FOR SURVEYING Battery This series electrical theodolite adopt rechargeable lithium battery, The battery is 3.7v,1400mAh. Insert and remove battery Turn off power,press the top button of battery box and then remove battery.insert the battery box into the groove and then press the top button of battery. Battery message Fully recharged new battery can be used 15 to 20 hours continuously. Right down message display consumption message. Each segment indicates about four hour s consumption energy. and indicate that battery level is abundant. indicates that the battery can be used only about two hours. Recharge the battery or replace with a recharged battery. When flickers then disappears indicates the battery level is low and. The instrument only can be used approximately 20 minutes. Stop operating and change the battery as soon as possible. 8

Battery recharging Battery should be recharged with the special charger. Insert the battery charger into the power source with 220V or 110V, remove the on-board battery from the main body, and connect the plug of the charger to the charging connector on the battery. The indicating red lamp is on that indicates the battery is been recharging and recharge will be completed after green lamp indicated. Then remove the plug from the charging connector. setup instrument Adjust the tripod legs to obtain a suitable height. Make sure the surveyed point is under the centering hole of tripod head. Level the tripod head and lock. Put the instrument on the tripod head and lock with the screws. Leveling Level the instrument with circular vial Turn B and C to let the bubble move to centre line. Turn knob A to let bubble stay at center of circular vial. Level the instrument with plate vial Loose level clamping knob and turn knob B and C to let bubble center. Rotate the instrument 90 and then turn knob A to let bubble center Repeat above steps in each 90 degrees rotating,and check if bubble have been centered Centering the instrument Turn on laser plummet, and make sure the laser land mark can been seen clearly, make sure that the land mark coincides with the center of the reticule,then lock the instrument. Repeat above steps and make sure the land mark definitely coincides with the center of the reticule. www.sitepro.us.com 9

Power on instrument To turn power ON, Press red power is on. key and hold it until all the symbols are displayed. The Sight target Turn telescope to bright background,turn eyepiece knob until reticle can been seen clearly. Use coarse sighting device to sight target. Rotate vertical and horizontal brake knob and focus knob of telescope until target can be seen clearly. Rotate vertical and horizontal fine knob until center of reticle precisely aim at target. Eliminate parallax. View the target in up and down,left and right position through scope. If there is relative displacement between target and both cross line images, rotate telescope focus knob until both images relative rest and can be seen clearly. ANGLE MEASUREMENT Normal/reversed position telescope Normal position telescope means that the shaft disc is on the left side of the telescope when observers face eyepiece lens. Reversed position telescope means that the shaft disc is on the right side of the telescope when observers face eyepiece lens. Averaging the value of normal/reversed position can effectively eliminate the instrument systematic errors. So when measure angle,please rotate telescope 180 and observe with reversed position telescope after observing with normal position telescope. Horizontal angle 0 setting Sight the telescope at object A, press 0 00 00., set the horizontal angle reading as 10 Note: The key is valid only for horizontal angle. Horizontal angle can be set to 0 at any time except when key is locked.

Horizontal and vertical angle measurement Set the mode for horizontal right, Press mode. to change horizontal angle from right to left If display left,turn the alidade at clockwise to add horizontal angle. If display left,turn the alidade at counterclockwise to add horizontal angle. Choosing left and right measuring style are decided by observers preference. Vertical angle measurement setting There are two way of measuring vertical angle: zenith 0 degree and 90 degrees Measurement Sight target 1 with cross line centered Press, horizontal angle setting of target 1 is 0 00 00 Turning clockwise, sight target 2 with cross line center, horizontal angle between target 1 and 2 (turning right) will be displayed. Example: Sight Target 1 Press Vertical angle of target 1 (zenith distance) Horizontal angle of target 1 has been set to 0 Choose the direction of the horizontal angle measurement, sight target 2 Vertical angle of target 2 (zenith distance) Horizontal angle, right turning direction target 1 has been set to 0 www.sitepro.us.com 11

Press, choose right, turn telescope at counterclockwise, then sight target 1 with cross line center. Press,horizontal angle of Target 1 turn to be 0 position, then sight target 2 with cross line center,display horizontal angle between 1 and 2 (turning left). Rotate telescope 180 degree, repeat steps. Horizontal angle lock and release In the procedure of horizontal angle observation, if you want to retain the measured value,press. left, right, horizontal characters flicker at lower left of the display and the horizontal angle value will not change even if you rotate the instrument when you sight at any direction. Press again to release lock function. Note: lock and release of is only valid for horizontal angle. Horizontal angle quadrant setting Sight at the first object and then press to set the horizontal angle to zero. Turn the instrument around the vertical axis until the beep starts, displaying. Lock the instrument by the clamp screw and set the horizontal angle to 90 00 00 by the tangent screw. Then, fix the quadrant target direction by the telescope reticule. Repeat to setting quadrant target point of 180, 270. The buzzer beeps when the reading passes any of 0, 90, 180, 270. Note: The beep can be canceled when we do initial setting. 12

Vertical angle 0 setting In initial setting, vertical 0 setting is zenith 0 /horizontal 0. ZEN=0 (zenith 0 ) ZEN=90 (zenith 90 ) Measurement of zenith distance and vertical angle Zenith Distance If vertical angle is 0 for zenith direction, the vertical angle measured in this way is the zenith distance. Target 1 Zenith (0 00 00 ) Q Zenith distance: Q = (L+360 -R) /2 Index difference: I = (L+R-360 ) /2 Horizontal direction (90 00 00 ) www.sitepro.us.com 13

Vertical Angle Target 1 Zenith (90 00 00 ) Q Horizontal direction (00 00 00 ) Vertical Angle: Q = (L+180 -R) /2 Index difference: I = (L+R-180 ) /2 or I = (L+R-540 ) /2 If vertical angle is 0 in horizontal direction, then, the vertical angle measured in this way is the perpendicular angle. Note: If index difference I 10, adjustment should be made as 8.6. Gradient percentage The vertical angle can be converted into gradient percentage in angle measurement mode. S Gradient percentage value = tg a * 100% = H/D * 100% H a D The range of gradient is from horizontal direction to ±45 (except 45 ). Otherwise the instrument will not display the grade percentage. Method: Press until two beeps, the display panel shows vertical angle or gradient percentage alternately. 14

DISTANCE MEASUREMENT Distance measurement with stadia hair of the telescope The distance from the measuring object to the instrument can be obtained by using the stadia hair (up and down or left and right) of the telescope, with the accuracy of 0.4%L(L: the distance of the target). Measurement methods: 1. Set up the instrument at point A and put the surveying rod on point B. 2. Read the intercept of apparent lines from up and down(or left and right) from the reticule on the survey rod. 3. The horizontal distance (L) between A and B equals L=a l00. INSPECTION AND ADJUSTMENT Let the plate vial be in parallel with a line joining any two of leveling screws. Adjust the two leveling screws and position the bubble in the center of the vial by turning the screws in opposite directions at the same time. Rotate the instrument 180. If the bubble is in the center and always in the center while the plate vial is moved to any directions, the plate vial is set correctly and the instrument is leveled. Adjustment Leveling with plate vial, bring it half way back to the center by adjusting the leveling screw which is parallel to the plate vial. Correcting the remaining half by adjusting the bubble adjusting screws with the adjusting pin. Confirm that the bubble does not move from the center when the instrument is rotated by 180.If not,repeat above steps. Turn the instrument around 90 and adjust the third screw to center the bubble in the vial. Repeat inspection and adjustment steps until the bubble remains in center in any directions. www.sitepro.us.com 15

Circular vial Ajustment is unnecessary if the bubble of the circular vial is in the center after inspection and adjustment of the plate vial. If not,it is necessary. If the bubble of the circular vial is not in the center, bring the bubble to the center by using adjusting pin or adjustable wrench to adjust the bubble adjusting screw. When adjusting, first loosen the screw on the Opposite of the offset side, then, tighten the adjusting screw on the offset side, bring it to the center. After the bubble stays in the center, keep the fastening strength of the three screws in uniformity. Reticule gradient of telescope Fix the instrument on tripod and level. Sight at an object A, approximately 50m far from instrument, through the telescope and lock the horizontal and vertical clamp screws. Move point A to the edge of the field of view by the vertical tangent screw. No adjustment is necessary if point A moves along the vertical line of the reticule. If the point A does not move along the vertical line, first, remove the reticule cover between eyepiece and focusing screw, and you can see the four screws. Loosen the four reticule adjusting screws uniformly with an adjusting pin. Rotate the reticule around the aiming axis, and align the vertical line of the reticule with point A.Tighten the reticule adjusting screw uniformly. Repeat the inspection and adjustment to check that if the adjustment is correct. Cover the reticule cover back. A Vertical hair A Sight axis A A 16

Perpendicularity of aiming axis to horizontal axis(2c) Fix the instrument on tripod and level. Sight at the object A in normal position (left or right ways turning are all acceptable,just keep in same way during inspecting,and please not press ) and read the horizontal angle left 1. Loosen vertical and horizontal clamp screws, and reverse the telescope. Sight at the object A in reversed position and read the horizontal angle value left 2 So: 2C = left 1 -(left 2 180 ) If 2C < 16, needless to adjust. If 2C 16, need to adjust. In the inverted position rotate flat mirror micro hand wheel so that the inverted mirror reading Left 2 = left 2 +C Take down the cover of the reticule. Adjust the two adjusting screws by loosening one and tightening the other. Move the reticule to sight at the object A exactly. Repeat inspection and adjustment until 2C <16. Cover the cover of reticule back. Vertical index zero compensation The instrument with vertical disc which be equipped with auto compensation and zerostoring device,please make inspection as follows: After precisely leveling the instrument,make the direction of telescope coincide with the line between center of instrument and screw of any tripod leg (setting as M),then tight the horizontal clamping knob. Turn power on,sight at target A and tight the vertical clamping knob,then instrument will display the vertical angle. Rotate the screw M slowly in one direction until it gets about 10mm and the instrument display TILT,it means the vertical incline has been out of compensation range. Then rotate the screw M in the opposite direction,the instrument is operating smoothly if vertical angle is redisplayed,otherwise, the compensator is abnormal or failure. The adjustment of the compensator is complicated, please send it to factory for repairing if it is abnormal or failure. www.sitepro.us.com 17

Vertical index difference and vertical index zeroing Note:After making adjustments make the inspection as following: Leveling the instrument and turn the power on. Then, sight at a reference A with normal position telescope and obtain the vertical angle (L). Reverse the telescope and sight at the object A again and obtain the vertical angle (R). If vertical angle is zero at zenith, then, vertical index difference I = (L+R-360 ) / 2 If vertical angle is zero at horizontal, then, I = (L+R-360 ) / 2 or (L+R-540 ) / 2. If I l0, vertical index zeroing should be set again. After leveling the instrument, press + key and,release when display characters and release + until three beeps,the instrument displays: In normal position, Sight at a clear and stable object A, which is nearly the same height as the instrument, turn the telescope around near the horizontal direction until vertical angle of A appears. Press key, displaying FACE-2. Reverse the telescope and sight at the object A again. Press key to finish vertical index zeroing setting. The instrument returns to angle measurement mode. Repeat the inspection procedure until index difference (I) meet the requirement, If the vertical index difference does not meet the standard yet after being adjusted repeatedly, the instrument should be sent to factory to be repaired. 18

TECHNICAL DATA Telescope Angle Measurement Compensation Image Erect Magnification 30 Objective Aperture Resolving Power 45mm Electronic (±5º) Field of View 1 30 Shortest Focusing Distance 1m Stadia Ratio 100 Resolving Power 3 Angle Measurement Mode Minimum count 1, 5 Mode of detection Precision 5 Measure-ment Unit Display Inclination sensor Working range ±3 Plummet Precision of plate vial Precision of circular vial Working Temperature Instrument weight Absolute Angle Encoder System H:double-line V:double-line DEG MIL GON LCD two sides Auto vertical compensation SKT05: Optical; SKT05L: Laser 30 /2mm 8 /2mm -25 C to +50 C 11lb (5kg) Volume 7.5 x 6.1 x 13.6 (190mm X 155mm X 345mm) www.sitepro.us.com 19

LASER PLUMMET (SKT05L) Press the twice to activate the laser plummet. To turn off the laser plummet, press the twice. ERROR MESSAGE Display TILT: If vertical disc compensator out of range, re-level instrument. If no change, send the instrument to an authorized service dealer for repair/maintenance. Note: the instrument can measure data even turn off compensator in initial status. Instruction: if there are error messages, fully check instrument firstly and repeat steps in the instruction manual. 20

www.sitepro.us.com 21

22 WARRANTY Limited Warranty Program SitePro warrants the Digital Theodolite to the original purchaser for a period of two (2) years from date of purchase against any defects in material or workmanship. This warranty does not cover part failure due to normal wear or tool abuse. For more details of warranty coverage and warranty repair information, call (855) 354-9881. This warranty does not apply to accessories items or damage caused where repairs have been made or attempted by person other than SitePro or authorized service center. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces. This Limited Warranty does not apply to accessory items such as tripods, rods, poles, prisms, hand levels, field supplies, instrument accessories and other related items. These items receive a 90 day limited warranty. To make a claim under this Limited Warranty, you must return the tool, transportation prepaid, along with any relevant paperwork (RGA number, if you have obtained one, proof of purchase, contact information, and any request for new accessories, etc.) to our Service Department or an Authorized Service Center. SitePro/Service Department, 7619 S 1150 E, Otterbein, IN 47970 IMPLIED WARRANTIES ARE EXPRESSLY LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING BUT NOT LIMITED TO LIABILITY FOR LOSS OF PROFITS) ARIS- ING FROM THE SALE OR USE OF THIS PRODUCT. SOME STATES IN THE U.S., AND SOME CANADIAN PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. SOME STATES IN THE U.S. AND SOME CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE EXCLUSION OR LIMITATION OF SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THESE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE/PROVINCE TO STATE/PROVINCE.

www.sitepro.us.com 23

Dave White s SitePro, LLC Otterbein, IN UM-29SKT05 12/12 mq Printed in China