Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Similar documents
Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Modeling of Transmission Line and Substation for Insulation Coordination Studies

EPRI Lightning Protection Design Workstation

Lightning Insulation Coordination Study


The Lightning Study of Overhead Transmission Lines

Lightning Flashover Rates of Overhead Distribution Lines Applying EMTP and IEEE Std.1410

DIRECT STROKE LIGHTNING PROTECTION DESIGN

Fatima Michael College of Engineering & Technology

Experimental and Analytical Studies on Lightning Surge Response of 500kV Transmission Tower

Lightning performance of distribution lines: sensitivity to computational methods and to data

UNIT I - INTRODUCTION SYLLABUS

Electric Field and Potential Distributions along Dry and Clean Non-Ceramic Insulators. Integrated Engineering Software - Website Links

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

Transient analysis of the behaviour of grounding systems consisted by driven rods

Analysis of Very Fast Transients in EHV Gas Insulated Substations

66kV & 220kV Substation Protection From Lightning by Fixed Angle, Rolling Sphere and Early Streamer Method

TRANSIENTS POWER SYSTEM. Theory and Applications TERUO OHNO AKIH1RO AMETANI NAOTO NAGAOKA YOSHIHIRO BABA. CRC Press. Taylor & Francis Croup

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation

TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD.

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

Energy Stored in Capacitors

MODELING OF THE DIRECT LIGHTNING STRIKE ON A TOWERS CASCADE EQUIPPED WITH ITS PROTECTIONS

Power Engineering II. Power System Transients

Comparison of Transient Simulations on Overhead Cables by EMTP and FDTD

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Electricity Review completed.notebook. June 13, 2013

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION

Chapter 2: Capacitor And Dielectrics

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Reinforced Concrete Pole in a Distribution Line

Prof. Dr. Magdi El-Saadawi

The objective of a grounding system are: 1. To provide safety to personnel during normal and fault conditions by limiting step and touch potential.

Experiment FT1: Measurement of Dielectric Constant

Physics 420 Fall 2004 Quiz 1 Wednesday This quiz is worth 6 points. Be sure to show your work and label your final answers.

INSTITUTE OF AERONAUTICAL ENGINERING DUNDIGAL ELECTRICAL AND ELECTRONICS ENGINEERING

Capacitance and Dielectrics. Chapter 26 HW: P: 10,18,21,29,33,48, 51,53,54,68

Finite Element Analysis of Disc Insulator Type and Corona Ring Effect on Electric Field Distribution over 230-kV Insulator Strings

HIGH VOLTAGE ENGINEERING. Electric discharges in electric power engineering

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

TRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR)

CAPACITORS / CAPACITANCE ECET11

Electrodynamics Qualifier Examination

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Overhead lines. 110 kv wood tower with guy wires

PHYSICS 9646/02. NANYANG JUNIOR COLLEGE Science Department JC 2 PRELIMINARY EXAMINATION Higher 2. Candidate Name. Tutor Name.

Lecture (5) Power Factor,threephase circuits, and Per Unit Calculations

Aalborg Universitet. Published in: Cigré International colloquium on lightning and power systems, Lyon Publication date: 2014

ECE 3318 Applied Electricity and Magnetism. Spring Prof. David R. Jackson Dept. of ECE. Notes 25 Capacitance

Calculations of Capacitance for Transposed Bundled Conductor Transmission Lines

Modeling of Overhead Power Lines for Broadband PLC Applications.

Keywords- Metal Oxide Surge Arrester, Model, Transient, Laboratory Experiment, Simulation.

iclicker A metal ball of radius R has a charge q. Charge is changed q -> - 2q. How does it s capacitance changed?

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Physics 3211: Electromagnetic Theory (Tutorial)

Definition of Capacitance

Transmission Line Transients

Lecture 11 Transmission Line Parameters

Graduate Diploma in Engineering Circuits and waves

OR Explain thermal breakdown in solid dielectrics. How this mechanism is

A Roadmap for Evaluation of Lightning Elimination Technologies

Simulation of the Electric Field on Composite Insulators Using the Finite Elements Method

Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid

Chapter 10 EMT1150 Introduction to Circuit Analysis

ELECTRIC FIELD AND VOLTAGE DISTRIBUTION ALONG INSULATORS UNDER POLLUTION CONDITIONS. V T Kontargyri N C Ilia I F Gonos I A Stathopulos

Parallel Plate Capacitor, cont. Parallel Plate Capacitor, final. Capacitance Isolated Sphere. Capacitance Parallel Plates, cont.

Identification File of Type ZE64G23

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B

3D modeling of Electrical Field and Electrical Potential in different contamination condition in Polymeric Insulator

Level 1 Physics, 2010

Proposal of Lightning Risk Assessment Method Based on the Lightning Current Probability Function for Railway Power Supply System

ELECTRICITY AND MAGNETISM, A. C. THEORY AND ELECTRONICS, ATOMIC AND NUCLEAR PHYSICS

General Physics (PHY 2140)

CAPACITORS / ENERGY STORED BY CAPACITORS / CHARGING AND DISCHARGING

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

Name: Class: Date: 1. Friction can result in the transfer of protons from one object to another as the objects rub against each other.

Chapter 2: Capacitors And Dielectrics

Phys 2025, First Test. September 20, minutes Name:

Lecture 12. Microwave Networks and Scattering Parameters

IEC Type Test Report Report No. EU1527-H-00.1 PH3 Series Polymer-housed Arrester 10,000 A Line Discharge Class 3

Physics 196 Final Test Point

PHYS 241 EXAM #2 November 9, 2006

Physics 222, Spring 2010 Quiz 3, Form: A

, times the dielectric constant of the material, k d. . With these definitions, Eq. 1 can be written as:

Capacitance, Resistance, DC Circuits

Capacitors. David Frazier and John Ingram

Lightning Protection Of Wind Turbines

Physics Electricity & Op-cs Lecture 8 Chapter 24 sec Fall 2017 Semester Professor

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Thermal and temperature cycling tests on solid dielectric switches, interrupters, and reclosers

Field Sensitive Air Terminal (F-SAT) Simply the Best Lightning Rod

Proposed revisions to IEEE Standard 998 (1996) Guide for Direct Lightning Stroke Shielding of Substations

INSTITUTE OF AERONAUTICAL ENGINERING DUNDIGAL ELECTRICAL AND ELECTRONICS ENGINEERING

Study of Time Correlation Between Lightning Data Recorded by LLS and Relay Protection

Review. Spring Semester /21/14. Physics for Scientists & Engineers 2 1

On the Influence of Earth Conduction Effects on the Propagation Characteristics of Aerial and Buried Conductors

ECE 325 Electric Energy System Components 5 Transmission Lines. Instructor: Kai Sun Fall 2015

Transcription:

Electrical, Electronic and Computer Engineering ENEL4HB - High oltage 2 Main Examination October 2016 Instructions Answer all questions, show all working and include all necessary comments (it is your reasoning that is being assessed, not the numerical answer) Time allowed = 2 hours Full marks = 100 Question 1 Consider the insulator shown, the insulator consists of a fibreglass rod and a silicon rubber coating. The ends of the insulator have metal end fittings one of which is connected to a high voltage and the other connected to a tower. Live End Fitting Dead End Fitting Sheath Shed Figure 1: Polymeric Insulator What are the advantages of polymeric insulators over ceramic insulators? Where would one expect the highest electric field to be and why? What are the issues with a high electric field? [Hint: Consider short term problems and long term problems in your answer] [8 Marks] How would one measure if there are any problems? What can one do to lower the electric field? [Hint: Consider Gauss law] [Total Marks: 25] 1

Question 2 Describe the 6 phases of the pollution flashover mechanism for ceramic insulators. [12 Marks] Describe two cases (different types of insulators, different types of pollution) where this mechanism is not applicable and why. [Total Marks: 15] Question 3 An overvoltage travels on a 132 k overhead line with a propagation velocity of v = 0.8c and steepness of S = 1500 k/µs. A metal oxide surge arrester is to be installed in front of a transformer with a U BIL = 550 k. The distance between the arrester and transformer is 25 m. Describe the operation and use of a metal oxide surge arrester for protection. Determine the voltage at the transformer if the surge arrester has a residual voltage of 330 k. [2 Marks] Comment on why there is an increase in voltage across the terminals of the transformer and whether the transformer is protected or not. Given that there is one incoming line with a single conductor and a span of 300 m, determine the protection distance that should be used and whether the transformer is currently protected or not. Table 1: Performance factor for incoming overhead line Line Type Factor A (k) Transmission lines (1φ to earth flashover) Single conductor 4500 Double conductor bundle 7000 Four conductor bundle 11000 Six and eight conductor bundle 17000 [Total Marks: 15] Question 4 A 275 k transmission tower with a height of 32 m has a surge impedance of 240 Ω connected to a single shield wire of 480 Ω and an earth resistance of 60 Ω. The phase conductor is connected to the tower by a 2 m long insulator. The transmission tower is struck by lightning with a peak current of 30 ka. The coupling coefficient is 0.1. Determine the peak voltage across the insulator string and if flashover occurs. (You may assume that the duration of the overvoltage is 2.5 µs) [9 Marks] Determine the number of insulator discs required if each has an expected flashover voltage of 125 k in dry weather based on U 50. [2 Marks] Determine the number of strikes of 30 ka to the a 100 km line if the ground flash density is 6 strikes per km 2 /year and comment on what this means. Determine the peak voltage across the insulator if the earth resistance is decreased to 20 Ω. [Total Marks: 20] 2

Question 5 A transmission line is situated in an area with ground flash density of 3 strikes/km 2 /year and has 2 shielding wires at a height of 35 m spaced 7.5 m apart and phase conductors at a height of 25 m. The phase conductor has an insulator flashover voltage (U 50 ) of 820 k and a surge impedance of 240 Ω. Determine the number of strikes per 100 km per year to the line. Determine I crit (ignore the effect of the tower impedance). Using the equation for attractive radius, describe a shielding failure and the concept of perfect shielding. [6 Marks] Determine the optimal separation distance for perfect shielding. Determine the probability of a lightning strike causing a shielding failure. [Total Marks: 20] Question 6 Sketch the standard partial discharge measurement system (including the device under test and measurement instrument) and discuss each component in the circuit. Include in your answer typical measurement quantities. [Total Marks: 10] 3

Useful Formulae Constants Standard temperature: t 0 = 20 o C Standard pressure: P 0 = 760 torr Permittivity of free space: ε 0 = 8.85 10 12 F/m Formulae Electric field in layer k in a uniform dielectric with multiple layers and permittivities: E k = ε k ε1 d 1 + ε k ε2 d 2 +... Electric field in layer k in a coaxial system with multiple layers and permittivities: E k = [ ] r εk k ε1 ln r2 r 1 + ε k ε2 ln r3 r 2 +... Electric field in relation to a line charge q: E = q r The equivalent bundle radius: θ r eq = ( nrr n 1) 1 n Relationship between Q and : [P ][Q] = [ ] [Q] = [P ] 1 [ ] Average bundle gradient: E a = q 1 n 2πɛ 0 r Average maximum bundle gradient: [ E am = E a 1 + (n 1) r ] R Peek s empirical expressions: E positive = 33.7mδ(1 + 0.24 ) δrc E negative = 31mδ(1 + 0.308 ) δrc E acpeak = 29.8mδ(1 + 0.301 ) δrc Relative air density: δ = P P 0 273 + t 0 273 + t oltage across cap and pin insulator string: n = sinh sinh Cp C s n Cp C s N Efficiency of cap and pin insulator: η = N N Resultant electric field: E R = 1 [P ] 1 [ ][ 1 r θ + 1 r θ ] Method of determinants: [ ] a11 a = det 12 = a 21 a 22 a 11 a 12 a 21 a 22 = a 11a 22 a 21 a 12 Self potential coefficient: P ii = 1 ln 2h i r i Mutual potential coefficient: P ij = 1 ln D ij d ij D ij = d ij = ((x i x j ) 2 + (y i + y j ) 2 ((x i x j ) 2 + (y i y j ) 2 = det a 11 a 12 a 13 a 21 a 22 a 23 = a 31 a 32 a 33 = a 11 a 22 a 33 + a 12 a 23 a 31 + a 13 a 21 a 32 a 31 a 22 a 13 a 32 a 23 a 11 a 33 a 21 a 12 Probability of negative lightning stroke: P = 1 1 + ( Ip 31 )2.6 Average number of strikes to line: ( 28h 0.6 ) + b N s = N g 10 a 11 a 12 a 13 a 21 a 22 a 23 a 31 a 32 a 33 4

Attractive radius: R a = 0.67h 0.67 t I 0.74 Flashover current: I crit = 2U 50 Z 0 Shielding separation: X sp = R s Rp 2 (Y s Y p ) 2 Reflection co-efficient: ρ r = Z 2 Z 1 Z 1 + Z 2 Insulator flashover volt-time curve: ( U(t) = 400 + 710 ) t 0.75 W Switching impulse strength of airgaps: U 50 = k 3400 1 + 8 d oltage at protected equipment: U equip = U a + 2 (d + a) S v Protective zone: L p = N ( ) UBIL A 1.15 U a L sp Paschen s eqn: b = 6.72 pd + 24.36(pd) 5