tip of a current tip and the sample. Components: 3. Coarse sample-to-tip isolation system, and

Similar documents
Scanning Tunneling Microscopy

REPORT ON SCANNING TUNNELING MICROSCOPE. Course ME-228 Materials and Structural Property Correlations Course Instructor Prof. M. S.

Lecture 4 Scanning Probe Microscopy (SPM)

Scanning Tunneling Microscopy

Scanning Tunneling Microscopy

Scanning Tunneling Microscopy. how does STM work? the quantum mechanical picture example of images how can we understand what we see?

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

Instrumentation and Operation

From nanophysics research labs to cell phones. Dr. András Halbritter Department of Physics associate professor

Scanning tunneling microscopy

Surface Studies by Scanning Tunneling Microscopy

MS482 Materials Characterization ( 재료분석 ) Lecture Note 11: Scanning Probe Microscopy. Byungha Shin Dept. of MSE, KAIST

Citation for published version (APA): Mendoza, S. M. (2007). Exploiting molecular machines on surfaces s.n.

Experimental methods in physics. Local probe microscopies I

General concept and defining characteristics of AFM. Dina Kudasheva Advisor: Prof. Mary K. Cowman

Scanning Tunneling Microscopy Transmission Electron Microscopy

672 Advanced Solid State Physics. Scanning Tunneling Microscopy

Scanning Probe Microscopy

Scanning Probe Microscopy. EMSE-515 F. Ernst

Introduction to Scanning Probe Microscopy Zhe Fei

Nanoscale characteristics by Scanning Tunneling Spectroscopy

MATERIAL SCIENCE AND TECHONOLOGY-1. Scanning Tunneling Microscope, STM Tunneling Electron Microscope, TEM HATİCE DOĞRUOĞLU

Scanning Probe Microscopy (SPM)

Bonds and Wavefunctions. Module α-1: Visualizing Electron Wavefunctions Using Scanning Tunneling Microscopy Instructor: Silvija Gradečak

Application of single crystalline tungsten for fabrication of high resolution STM probes with controlled structure 1

STM spectroscopy (STS)

Ecole Franco-Roumaine : Magnétisme des systèmes nanoscopiques et structures hybrides - Brasov, Modern Analytical Microscopic Tools

Lecture 26 MNS 102: Techniques for Materials and Nano Sciences

3.1 Electron tunneling theory

(Scanning Probe Microscopy)

Scanning Tunneling Microscopy

STM: Scanning Tunneling Microscope

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Program Operacyjny Kapitał Ludzki SCANNING PROBE TECHNIQUES - INTRODUCTION

Nanoscale work function measurements by Scanning Tunneling Spectroscopy

2) Atom manipulation. Xe / Ni(110) Model: Experiment:

Techniken der Oberflächenphysik (Techniques of Surface Physics)

CHARACTERIZATION of NANOMATERIALS KHP

Introduction to Scanning Probe Microscopy

Supplementary information

Module 40: Tunneling Lecture 40: Step potentials

Reducing dimension. Crystalline structures

Modern physics. 4. Barriers and wells. Lectures in Physics, summer

Curriculum Vitae December 2006

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

Scanning Tunneling Microscopy (STM)

The interpretation of STM images in light of Tersoff and Hamann tunneling model

Scanning Tunneling Microscopy/Spectroscopy

And Manipulation by Scanning Probe Microscope

MRSEC. Refrigerator Magnet Activity Guide. Quick Reference Activity Guide. a) b) c) = north = south. Activity Materials

Introduction to the Scanning Tunneling Microscope

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

Scanning Tunneling Microscopy Studies of the Ge(111) Surface

High resolution STM imaging with oriented single crystalline tips

SOLID STATE PHYSICS PHY F341. Dr. Manjuladevi.V Associate Professor Department of Physics BITS Pilani

Introduction to Scanning Tunneling Microscopy

The basics of Scanning Probe Microscopy

Control of Dynamics of SPM Probes for Non-destructive Defectoscopy

PY5020 Nanoscience Scanning probe microscopy

Imaging of Quantum Confinement and Electron Wave Interference

Scanning Tunneling Microscopy

NIS: what can it be used for?

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Scanning Probe Microscopy (SPM)

Supplementary Information for Solution-Synthesized Chevron Graphene Nanoribbons Exfoliated onto H:Si(100)

INTRODUCTION TO SCA\ \I\G TUNNELING MICROSCOPY

Scanning Tunneling Microscopy. Wei-Bin Su, Institute of Physics, Academia Sinica

Atomic Force Microscopy (AFM) Part I

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

Quantum Condensed Matter Physics Lecture 12

1986 s Nobel Prize in Physics

Scanning Tunneling Microscopy of Diamond Coated Surfaces

Barrier Penetration, Radioactivity, and the Scanning Tunneling Microscope

Lesson Template Subject Area(s) Physics Associated Unit

Surface physics, Bravais lattice

Spectroscopy at nanometer scale

Scanning Probe Microscopies (SPM)

Microscopy and Spectroscopy with Tunneling Electrons STM. Sfb Kolloquium 23rd October 2007

MSE 321 Structural Characterization

Probing Molecular Electronics with Scanning Probe Microscopy

CH676 Physical Chemistry: Principles and Applications. CH676 Physical Chemistry: Principles and Applications

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

Scanning Tunneling Microscopy

Microscopical and Microanalytical Methods (NANO3)

Atomic and molecular interactions. Scanning probe microscopy.

Scanning Tunneling Microscopy: theory and examples

SUPPLEMENTARY INFORMATION

Construction of a Low Temperature Scanning. Tunneling Microscope

Surface Characte i r i zat on LEED Photoemission Phot Linear optics

Spectroscopy of Nanostructures. Angle-resolved Photoemission (ARPES, UPS)

CNPEM Laboratório de Ciência de Superfícies

SUPPLEMENTARY NOTES Supplementary Note 1: Fabrication of Scanning Thermal Microscopy Probes

Spatially resolving density-dependent screening around a single charged atom in graphene

Atomic Force Microscopy

Implementation of spin detection in a commercial low temperature scanning tunneling microscope

Scanning Tunneling Microscopy and its Application

MSE 321 Structural Characterization

Local spectroscopy. N. Witkowski W. Sacks

PHY 114 A General Physics II 11 AM-12:15 PM TR Olin 101

SUPPLEMENTARY INFORMATION

Transcription:

SCANNING TUNNELING MICROSCOPE Brief history: Heinrich Rohrer and Gerd K. Binnig, scientists at IBM's Zurich Research Laboratory in Switzerland, are awarded the 1986 Nobel Prize in physicss for their work in scanning tunnelling microscopy. Binnig and Rohrer were recognized for developing the powerful Scanning Tunnelling Microscopy technique. They shared the award with German scientist Ernst Ruska, designer of the first Electron Microscope. STM can form an image of individual atoms on a metal, semiconductor or other conductive sample surface by scanning the tip of a needle over the surface at a height of only a few atomic diameters, so that tunnel current occurs between the tip and the sample. Purpose: A scanning tunnelling microscope is used to demonstrate the principle of quantum mechanicaltunnelling between the microscope tip and the surface of a conducting sample. Components: 1. Scanning tip 2. Piezoelectric controlled height and x, y scanner 3. Coarse sample-to-tip isolation system, and 5. Computer (Data processing and display unit) control, 4. Vibration Schematic diagram:

Working: Scanning tunneling microscope scans the electrons at fixed distance. First, a voltage bias is applied and the conducting tip is placed closer to the sample to be examined. The tip is also known as stylus, stylus is extremely sharp and usually made up of a finestdiamond, which is switched off when the tip and sample are sufficiently close. When a conducting edge or tip is brought near the surface to be tested, a specific voltage variation is applied which allows electrons to pass through the tunnel in the vaccum.in the result, tunneling current is obtained which is the function of accurate tip position. Information is gathered by monitoring the current according to the tip position which scans across the surface, and this information is usually displayed in form of image. The stylus is moved in the upward direction and then lowered in order to keep the each signal undistorted.this allows it to follow even the smallest data of the surface it is scanning. Storing the vertical movement of the stylus makes it possible to observe the structure of the surface atomically in organized manner. A profile of the scanned surface is created, and with the help of this profile contouring map is generated from the computer system attached to the microscope. The STM works best with conductors. But it can also work with the organic molecules all required is to fix organic molecules on a surface and study their structures. This technique has been used in the study of DNA molecules. Modes of operation: 1. Constant Current Mode: By using a feedback loop the tip is vertically adjusted in such a way that the current always stays constant. As the current is proportional to the local density of states, the tip follows a contour of a constant density of states during scanning. A kind of a topographic image of the surface is generated by recording the vertical position of the tip. 2. Constant Height Mode: In this mode the vertical position of the tip is not changed, equivalent to a slow or disabled feedback. The current as a function of lateral position represents the surface image. This mode is only appropriate for atomically flat surfaces as otherwise a tip crash would be inevitable. One of its advantages is that it can be used at high scanning frequencies (up to 10 khz). In comparison, the scanning frequency in the constant current mode is about 1 image per second or even per several minutes.

3. Barrier Height Imaging: The Local Barrier Height (LBH) spectroscopy provides information about the spatial distribution of the microscopic work function of the surface, as described below. The tunneling current I T in STM exponentially decays with the tip-sample separation z as where the decay constant is given by I T ~ exp(-2kz), 2k = 2(2mU/h2) 1/2. In the LBH imaging, we measure the sensitivity of tunnel current to the tip-sample separation at each pixel of an STM image. The LBH obtained in this method is the so-called apparent barrier height U defined by U= 0,95(1/I T )2 (di T /dz)2 This U is customarily compared to an average work function U av = (U s + U t )/2, where U t and U s are the tip and sample work functions, respectively. In many cases, experimental U does not precisely agree with U av but tends to be slightly smaller. Nevertheless, it is known that U is closely related to the local surface potential (local work function) and is a good measure of it. The LBH image is obtained by measuring point by point the logarithmic change in the tunneling current with respect to the change in the gap separation, that is, the slope of log I vs. z. In the LBH measurement, the tip-sample distance is modulated sinusoidally by an additional AC voltage applied to the feedback signal for the z-axis piezodevice attached to the tip. The modulation period is chosen to be much shorter than the time constant of the feedback loop in the STM. 4. Density of States Imaging: As long as measured in STM current is determined by the tunneling processes through tipsample surface gap its value depends not only on the barrier height but on the electron density of states also. Accordingly obtained in STM images are not simply images of sample surface relief (topography), these images can be hardly affected by the density of electronic states distribution over the sample surface. Good example of Local Density of States (LDOS) influence on the STM image is well-known image of highly oriented pyrolitic graphite (HOPG) atomic lattice. Only half atoms are visible in STM. Similar case is image of GaAs atomic lattice. LDOS determining can also help to distinguish chemical nature of the surface atoms. LDOS acquisition is provided simultaneously with the STM images obtaining. During scanning the

Bias Voltage is modulated on the value du, the modulation period is chosen to be much shorter than the time constant of the feedback loop in the STM. Suitable modulation of tunnel current di is measured, divided by du and presented as LDOS image. On Example the topography and LDOS image of HOPG sample are presented. Example: With a large band gap, a high break down field and a high saturation drift velocity of the conducting electrons SiC is an interesting material for semiconductor technology. Thus its surface structure and the surface electronic properties are of a great importance for material growth and device fabrication. SiC surface show a variety of surface reconstructions. One of those structures is the (3x3) phase on SiC(0001) whose actual atomic geometry has long been unresolved. STM experiments provided some insight in the structure: 1. There is a single protrusion per unit cell 2. The corrugation is independent of the tunneling voltage 3. Large corner holescannot be seen 3x3 4H SiC (0001) Combining this with results from electron spectroscopy and low-energy electron diffraction (LEED) The surface geometry could be determined in detail.

The properties of the SiC(0001) 3x3 structure are: a compact, planar Si adlayer with sp 2 hybridisation within the layer, a twist rotation of the Si-trimer covering the adlayer and its surrounding atoms within the adlayer, single dangling bond per (3x3) unit cell located at the adatom ontop of the trimer, ideal Si-Si bond lengths (2.31-2.39Å) and fourfold coordination of all other atoms. Some issues regarding STM: 1. STM could be a challenging technique, as it needs very clean and plain and stable surfaces, extra sharp tips, high vibrationcontrol, and efficient and integrated electronic devices. These all specifications make STM expensive. 2. The resolution of the image scanned by STM is limited because radius of curvature is fixed and scanning stylus tip does not support the modification in the resolution. 3. If scanning tip has two tips than there is a chance of occurrence of artifacts instead of single atom display. 4. Because of huge sensitivity of tunnel current, proper vibration and isolation is required for obtaining best results from the STM. 5. At first, Binnig and Rohrer magneticlevitation was used to keep the scanning tunnelingmicroscope free from extra vibrations and now mechanical or gaseous spring systems are usually used for controlling vibrations. Additional mechanisms for reducing current are also required sometime to proper implement the scan.