Drive Technology \ Drive Automation \ System Integration \ Services. Data Sheet. Functional Safety Safety Characteristics for BE..

Similar documents
Drive Technology \ Drive Automation \ System Integration \ Services. Data Sheet. Functional Safety Safety Characteristics for Brake BE..

Data Sheet. Functional Safety Characteristic Safety Values for BE.. Brakes * _0715*

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715*

Kinetics of Complex Reactions

Standard BAL Real Power Balancing Control Performance

Provläsningsexemplar / Preview TECHNICAL REPORT INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

Solutions. Number of Problems: 4. None. Use only the prepared sheets for your solutions. Additional paper is available from the supervisors.

Standard BAL-001-0a Real Power Balancing Control Performance

Power supplies for parallel operation Power supplies

62. Power series Definition 16. (Power series) Given a sequence {c n }, the series. c n x n = c 0 + c 1 x + c 2 x 2 + c 3 x 3 +

KMXP MR Position Sensor

Sequences of Definite Integrals, Factorials and Double Factorials

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 6 - Small Signal Stability

Department of Civil Engineering-I.I.T. Delhi CEL 899: Environmental Risk Assessment HW5 Solution

NUMERICAL METHODS FOR SOLVING EQUATIONS

Committee Draft. Ballot ID: mass. Action item Reference Number: API RP 581 RISK-BASED INSPECTION TECHNOLOGY. COF eneff Correction.

) +m 0 c2 β K Ψ k (4)

Magnetic Length Sensor MLS (Hybrid)

Orthogonal Gaussian Filters for Signal Processing

Nernst Equation. Nernst Equation. Electric Work and Gibb's Free Energy. Skills to develop. Electric Work. Gibb's Free Energy

Accuracy of prediction methods for the improvement of impact sound pressure levels using floor coverings

Student s Printed Name:

1 Hash tables. 1.1 Implementation

OBJECTIVES. Chapter 1 INTRODUCTION TO INSTRUMENTATION FUNCTION AND ADVANTAGES INTRODUCTION. At the end of this chapter, students should be able to:

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science. BACKGROUND EXAM September 30, 2004.

NATIONAL SENIOR CERTIFICATE GRADE 12

Solution of EECS 315 Final Examination F09

EXAMINATIONS OF THE ROYAL STATISTICAL SOCIETY

6.867 Machine learning, lecture 7 (Jaakkola) 1

Teaching Mathematics Concepts via Computer Algebra Systems

School of Electrical Engineering. EI2400 Applied Antenna Theory Lecture 9: Broadband antennas

Math 113 Exam 3 Practice

Queueing theory and Replacement model

Measurement uncertainty of the sound absorption

Classification of problem & problem solving strategies. classification of time complexities (linear, logarithmic etc)

WHAT IS THE PROBABILITY FUNCTION FOR LARGE TSUNAMI WAVES? ABSTRACT

Answer: 1(A); 2(C); 3(A); 4(D); 5(B); 6(A); 7(C); 8(C); 9(A); 10(A); 11(A); 12(C); 13(C)

Triatomics-in-molecules method applied to helium cluster cations

CHAPTER I: Vector Spaces

Analysis of the No-Load Characteristic of the Moving Coil Linear Compressor

Rademacher Complexity

Signal Processing. Lecture 02: Discrete Time Signals and Systems. Ahmet Taha Koru, Ph. D. Yildiz Technical University.

577. Estimation of surface roughness using high frequency vibrations

Shock Transducer with Hall Sensing Element

EXPERIMENT OF SIMPLE VIBRATION

TEACHER CERTIFICATION STUDY GUIDE

NATIONAL SENIOR CERTIFICATE GRADE 12

METRO EAST EDUCATION DISTRICT

Butterworth LC Filter Designer

6.867 Machine learning

sin(n) + 2 cos(2n) n 3/2 3 sin(n) 2cos(2n) n 3/2 a n =

Lecture 19: Convergence

C. Complex Numbers. x 6x + 2 = 0. This equation was known to have three real roots, given by simple combinations of the expressions

n m CHAPTER 3 RATIONAL EXPONENTS AND RADICAL FUNCTIONS 3-1 Evaluate n th Roots and Use Rational Exponents Real nth Roots of a n th Root of a

Comparison Study of Series Approximation. and Convergence between Chebyshev. and Legendre Series

Chapter 3. Strong convergence. 3.1 Definition of almost sure convergence

PROFICIENCY TESTING ACTIVITIES OF FREQUENCY CALIBRATION LABORATORIES IN TAIWAN, 2009

6.003 Homework #3 Solutions

Test One (Answer Key)

To the use of Sellmeier formula

THE SYSTEMATIC AND THE RANDOM. ERRORS - DUE TO ELEMENT TOLERANCES OF ELECTRICAL NETWORKS

SHAFTS: STATICALLY INDETERMINATE SHAFTS

A. Much too slow. C. Basically about right. E. Much too fast

GRADE 12 SEPTEMBER 2015 MATHEMATICS P1

TRACEABILITY SYSTEM OF ROCKWELL HARDNESS C SCALE IN JAPAN

Supporting information to. and Ruben Kretzschmar. Institute of Isotope Geochemistry and Mineral Resources, ETH Zurich, NO, 8092 Zürich, Switzerland

Using SAS to Evaluate Integrals and Reverse Functions in Power and Sample Size Calculations

Exmple Questions for the Examination for 4041 OPTICAL COMMUNICATION ENGINEERING

DESCRIPTION OF THE SYSTEM

CUMULATIVE DAMAGE ESTIMATION USING WAVELET TRANSFORM OF STRUCTURAL RESPONSE

Appendix: The Laplace Transform

Design and Analysis of ALGORITHM (Topic 2)

ESTIMATION OF QUALITY PARAMETERS IN THE RADIO FLIGHT SUPPORT OPERATIONAL SYSTEM

Summary: CORRELATION & LINEAR REGRESSION. GC. Students are advised to refer to lecture notes for the GC operations to obtain scatter diagram.

ln(i G ) 26.1 Review 26.2 Statistics of multiple breakdowns M Rows HBD SBD N Atoms Time

Robust Default Correlation for Cost Risk Analysis

1 Adiabatic and diabatic representations

Building Blocks Problem Related to Harmonic Series

Exponents. Learning Objectives. Pre-Activity

PH 411/511 ECE B(k) Sin k (x) dk (1)

Math 31B Integration and Infinite Series. Practice Final

Probabilistic Classifiers Using Nearest Neighbor Balls. Climate Change Workshop, Malta, March, 2009

Sample Size Determination (Two or More Samples)

NATIONAL SENIOR CERTIFICATE GRADE 12

1 1 2 = show that: over variables x and y. [2 marks] Write down necessary conditions involving first and second-order partial derivatives for ( x0, y

Probability, Expectation Value and Uncertainty

Lesson 10: Limits and Continuity

Math 113 Exam 4 Practice

Office: JILA A709; Phone ;

METRO EAST EDUCATION DISTRICT NATIONAL SENIOR CERTIFICATE GRADE 12 MATHEMATICS PAPER 1 SEPTEMBER 2014

Multilayer perceptrons

MCT242: Electronic Instrumentation Lecture 2: Instrumentation Definitions

1 Review of Probability & Statistics

Unit 5. Gases (Answers)

Chapter 6 Infinite Series

CS / MCS 401 Homework 3 grader solutions

MISCELLANEOUS SEQUENCES & SERIES QUESTIONS

CHM 424 EXAM 2 - COVER PAGE FALL

Physics Supplement to my class. Kinetic Theory

Transcription:

Drive Techology \ Drive Automatio \ System Itegratio \ Services Data Sheet Fuctioal Safety Safety Characteristics for BE.. Brake Editio 12/2010 17062810 / EN

SEW-EURODRIVE Drivig the world

Data Sheet Safety otes kva i P f Hz 1 1 Data Sheet INFORMATION 1) We reserve the rights to make techical chages. This data sheet applies i additio to the "DR.71-225, 315 AC Motors" operatig istructios. Please observe the data specified i this publicatio. This documet does ot replace the detailed operatig istructios "DR.71-225, 315 AC Motors". Observe the other applicable documetatio 1) : "DR.71-225, 315 AC Motors" operatig istructios "DR. Series AC Motors" catalog 1.1 Safety otes INFORMATION Meaig of the value "MTTF d ": MTTF d is a statistical value. It is defied i the stadard EN ISO 13849-1 as "expected value of the mea time to dagerous failure". Statistical value meas that it is a value that has bee determied empirically. The value does ot imply a "guarateed operatig life" or a "failure-free time". For the BE.. brake, the value MTTF d refers to its capability of performig the mechaical switchig operatio, that is to move the pressure plate. Wear of the brake liig, which is caused by the coversio of kietic eergy durig the brakig process, does ot affect this value. The values differ for every applicatio because the value MTTF d depeds o the mea umber of actuatios per year. INFORMATION Observe the techical data for the brake i the "DR.71-225, 315 AC Motors" operatig istructios, i particular the maximum permitted work doe by the brake. INFORMATION Usage i safety-relevat applicatios: The system/machie maufacturer is resposible for compliace of the system/ machie with applicable safety regulatios. If a BE.. brake is used to fulfil a safety fuctio, the the brake is to be regarded as compoet (elemet) ad ot as safety-related subsystem. Usually, the BE.. brake aloe is ot sufficiet to execute a safety fuctio i compliace with the stadard. Data Sheet Fuctioal Safety Safety Characteristics for BE.. Brake 3

1 kva i P f Hz Data Sheet Characteristic safety values 1.2 Characteristic safety values Defiitio of the characteristic safety value B 10d : The value B 10d specifies the umber of cycles at which 10% of compoets have failed dagerously (defiitio accordig to stadard EN ISO 13849-1). Failed dagerously meas i this cotext that the brake is ot applied whe required. This meas the brake does ot deliver the ecessary brakig torque. Size B 10d Switchig cycles BE05 16.000.000 BE1 12.000.000 BE2 8.000.000 BE5 6.000.000 BE11 3.000.000 BE20 2.000.000 BE30 1.500.000 BE32 1.500.000 BE60 1.000.000 BE62 1.000.000 BE120 250.000 BE122 250.000 Defiitio of the categories: The categories classify safety-related compoets regardig their resistace to errors ad their respose i the evet of a error based o the reliability ad/or the structural arragemet of the parts. A higher resistace to errors meas a higher potetial to reduce risk. Brake type Category BE.. brake without safety techology Category B (accordig to EN ISO 13849-1) Safety characteristics BE.. brake (FS) Category 1 (accordig to EN ISO 13849-1) 1.3 Sample calculatios Below some examples for how to use the value B 10d to calculate the mea time to dagerous failure (MTTF d ). I the examples, the values MTTF d are calculated for size BE11 based o 2 differet switchig frequecies. The equatios used are described i stadard EN ISO 13849-1. The followig sample calculatios are based o two selected applicatios. The calculatio has to be adjusted for other applicatios. Also, other parameters might ifluece the calculatio. If you have ay questios o calculatig the values, please cotact SEW-EURODRIVE. 4 Data Sheet Fuctioal Safety Safety Characteristics for BE.. Brake

Data Sheet Sample calculatios kva i P f Hz 1 1.3.1 Example 1 Iput data: Iput data for the BE11 brake: B 10d = 3 000 000 Operatig days per year: d op = 300 d/a Daily operatig period: h op = 24 h/d Cycle time: t cycle = 87 s Startig frequecy: 41.4 per hour Calculatio: MTTF d B10d = 01. x op op d = op s xhop x 3600 h t cycle Isertig the values: d h s 300 24 3600 a d h op = 87s = 297. 931 1 a MTTFd = 3 000 000 a = 100. 7a 0. 1x 297 931 Result: MTTF d = 100 years The result is assiged to "High" accordig to stadard EN ISO 13849-1 as show i the followig table. Desigatio Low Medium High Rage 3 years MTTF d < 10 years 10 years MTTF d < 30 years 30 years MTTF d 100 years Data Sheet Fuctioal Safety Safety Characteristics for BE.. Brake 5

1 kva i P f Hz Data Sheet Sample calculatios 1.3.2 Example 2 Iput data: Iput data for the BE11 brake: Same values as i example 1 but with reduced cycle time Cycle time: t cycle = 25 s Startig frequecy: 144 per hour Calculatio: Make the calculatio as show i example 1. Result: MTTF d = 29 years The result is assiged to "Medium" accordig to stadard EN ISO 13849-1. 6 Data Sheet Fuctioal Safety Safety Characteristics for BE.. Brake

SEW-EURODRIVE Drivig the world SEW-EURODRIVE Drivig the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D-76642 Bruchsal/Germay Phoe +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com