ERRORS IN CONCRETE SHEAR WALL ELASTIC STRUCTURAL MODELING

Similar documents
MODEL FOR FLEXIBLE PLATES SUPPORTED ON PILES

THE BEHAVIOUR OF ELASTOMERIC BEARINGS UNDER LOAD COMBINATIONS

A COMPARATIVE ANALYSIS OF WEB BUCKLING RESISTANCE: STEEL PLATE GIRDERS GIRDERS WITH CORRUGATED WEBS

THE EXPERIMENTAL TESTING AND NUMERICAL MODEL CALIBRATION OF A STEEL STRUCTURE

COMPARATIVE ANALYSIS OF THE BENDING THEORIES FOR ISOTROPIC PLATES. CASE STUDY

THE OPERATIONAL FIABILITY IN THERMAL SYSTEMS THE WEIBULL DISTRIBUTION MODEL

FINITE ELEMENT ANALYSIS OF FRICTIONAL CONTACTS

INFLUENCES IN THERMAL CONDUCTIVITY EVALUATION USING THE THERMAL PROBE METHOD; SOME PRACTICAL ASPECTS

CONFERINŢA INTERNAŢIONALĂ DEDUCON 70

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

CAPACITY DESIGN FOR TALL BUILDINGS WITH MIXED SYSTEM

Multi Linear Elastic and Plastic Link in SAP2000

Degree of coupling in high-rise mixed shear walls structures

STUDY REGARDING THE STATIC AND DYNAMIC ANALYSIS OF WOOD BEAMS LOADING BY UNIFORM AND CONCENTRATED FORCES

Seismic design of bridges

MANLEY-ROWE TYPE RELATIONS CONCERNING THE ACTIVE PSEUDOPOWERS

Finite Element Modelling with Plastic Hinges

THERMAL CONDUCTIVITY MEASUREMENT OF CONSTRUCTION MATERIALS USING THE THERMAL PROBE METHOD

M.S Comprehensive Examination Analysis

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

Nonlinear Vibrations of Elastic Beams

VORONOI APPLIED ELEMENT METHOD FOR STRUCTURAL ANALYSIS: THEORY AND APPLICATION FOR LINEAR AND NON-LINEAR MATERIALS

FRAME ANALYSIS. Dr. Izni Syahrizal bin Ibrahim. Faculty of Civil Engineering Universiti Teknologi Malaysia

BIODEGRADABLE POLYMERS AND THEIR INFLUENCE ON ADHERENCE BETWEEN TEXTILE PRODUCTS AND WOOD

HEAT TRANSFER STUDY IN A COAXIAL HEAT EXCHANGER USING NANOFLUIDS

2D AND 3D PROCESSING OF THE INTERDEPENDENCE BETWEEN THE COMFORT MAIN INDICATORS

Delft Applied Mechanics Course: Statics AE1-914-I. 18 August 2004, 9:00 12:00

FORMULA FOR FORCED VIBRATION ANALYSIS OF STRUCTURES USING STATIC FACTORED RESPONSE AS EQUIVALENT DYNAMIC RESPONSE

Due Tuesday, September 21 st, 12:00 midnight

SIMPLIFIED METHOD FOR PREDICTING DEFORMATIONS OF RC FRAMES DURING FIRE EXPOSURE

Validation of the Advanced Calculation Model SAFIR Through DIN EN Procedure

Verification Examples. FEM-Design. version

ΙApostolos Konstantinidis Diaphragmatic behaviour. Volume B

Improving fire resistance of existing concrete slabs by concrete topping

The 5rd International Conference on. COMEC OCTOBER 2013, Brasov, Romania

EVALUATION OF A GENERAL PERFORMANCE INDEX FOR FLEXIBLE ROAD PAVEMENTS

NUMERICAL SIMULATIONS OF CORNERS IN RC FRAMES USING STRUT-AND-TIE METHOD AND CDP MODEL

SIMPLE MODEL FOR PRYING FORCES IN T-HANGER CONNECTIONS WITH SNUG TIGHTENED BOLTS

Inelastic shear response of RC coupled structural walls

LOSS FACTOR AND DYNAMIC YOUNG MODULUS DETERMINATION FOR COMPOSITE SANDWICH BARS REINFORCED WITH STEEL FABRIC

3-D FINITE ELEMENT ANALYSIS OF A SINGLE-PHASE SINGLE-POLE AXIAL FLUX VARIABLE RELUCTANCE MOTOR

Civil Engineering Design (1) Design of Reinforced Concrete Columns 2006/7

A Mathematical Formulation to Estimate the Fundamental Period of High-Rise Buildings Including Flexural-Shear Behavior and Structural Interaction

FLEXIBILITY METHOD FOR INDETERMINATE FRAMES

Beams. Beams are structural members that offer resistance to bending due to applied load

Supplement: Statically Indeterminate Frames

Ph.D. Preliminary Examination Analysis

Verification of a Micropile Foundation

The University of Melbourne Engineering Mechanics

Comparison of Structural Models for Seismic Analysis of Multi-Storey Frame Buildings

MECHANICS OF STRUCTURES SCI 1105 COURSE MATERIAL UNIT - I

3.4 Analysis for lateral loads

A METHOD OF LOAD INCREMENTS FOR THE DETERMINATION OF SECOND-ORDER LIMIT LOAD AND COLLAPSE SAFETY OF REINFORCED CONCRETE FRAMED STRUCTURES

FINITE ELEMENT ANALYSIS OF TAPERED COMPOSITE PLATE GIRDER WITH A NON-LINEAR VARYING WEB DEPTH

Module 3. Analysis of Statically Indeterminate Structures by the Displacement Method

STRESS AND STRAIN ANALYSIS IN CONTINUUM MECHANICS WITH APPLICABILITY IN SOIL MECHANICS

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

Structural Analysis Lab

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

Module 6. Approximate Methods for Indeterminate Structural Analysis. Version 2 CE IIT, Kharagpur

Strength of Material. Shear Strain. Dr. Attaullah Shah

Module 3. Analysis of Statically Indeterminate Structures by the Displacement Method

DIFFERENTIAL EQUATION OF A VISCO-ELASTIC BEAM SUBJECTED TO BENDING

Analysis of Concrete Walls under Earthquake Action Influence from different types of Foundation

Design of AAC wall panel according to EN 12602

Supplement: Statically Indeterminate Trusses and Frames

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

UNIT IV FLEXIBILTY AND STIFFNESS METHOD

A. Belejo, R. Bento & C. Bhatt Instituto Superior Técnico, Lisbon, Portugal 1.INTRODUCTION

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Entrance exam Master Course

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

PRACTICE 2 PROYECTO Y CONSTRUCCIÓN DE PUENTES. 1º Máster Ingeniería de Caminos. E.T.S.I. Caminos, canales y puertos (Ciudad Real) 01/06/2016

Simple Method for Analysis of Tube Frame by Consideration of Negative Shear Lag

This Technical Note describes how the program checks column capacity or designs reinforced concrete columns when the ACI code is selected.

FINITE GRID SOLUTION FOR NON-RECTANGULAR PLATES

Ph.D. Preliminary Examination Analysis

STEEL JOINTS - COMPONENT METHOD APPLICATION

Slenderness Effects for Concrete Columns in Sway Frame - Moment Magnification Method (CSA A )

Codal Provisions IS 1893 (Part 1) 2002

Chapter 12. Static Equilibrium and Elasticity

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

Structural Steelwork Eurocodes Development of A Trans-national Approach

IMPROVING LATERAL STIFFNESS ESTIMATION IN THE DIAGONAL STRUT MODEL OF INFILLED FRAMES

Theory of structure I 2006/2013. Chapter one DETERMINACY & INDETERMINACY OF STRUCTURES

Chapter 11. Displacement Method of Analysis Slope Deflection Method

2012 MECHANICS OF SOLIDS

Dynamic Response of Beams on Elastic Foundation with Axial Load

Plastic design of continuous beams

Fire Analysis of Reinforced Concrete Beams with 2-D Plane Stress Concrete Model

Methods of Analysis. Force or Flexibility Method

twenty one concrete construction: shear & deflection ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

Module 4 : Deflection of Structures Lecture 4 : Strain Energy Method

STRESS FIELD MODELS FOR STRUCTURAL CONCRETE

Static & Dynamic. Analysis of Structures. Edward L.Wilson. University of California, Berkeley. Fourth Edition. Professor Emeritus of Civil Engineering

Civil Engineering Design (1) Analysis and Design of Slabs 2006/7

FINDING THE TRACES OF A GIVEN PLANE: ANALYTICALLY AND THROUGH GRAPHICAL CONSTRUCTIONS

Influence of the Plastic Hinges Non-Linear Behavior on Bridges Seismic Response

Types of Structures & Loads

CHAPTER 4. Design of R C Beams

Transcription:

BULETINUL INSTITUTULUI POLITEHNIC DIN IAŞI Publicat de Universitatea Tehnică Gheorghe Asachi din Iaşi Tomul LVII (LXI), Fasc. 2, 2011 Secţia CONSTRUCŢII. ĂRHITECTURĂ ERRORS IN CONCRETE SHEAR WALL ELASTIC STRUCTURAL MODELING BY OVIDIU CHELARIU *, IOAN-PETRU CIONGRADI and MIHAI BUDESCU Gheorghe Asachi Technical University of Iaşi, Faculty of Civil Engineering and Building Services Received: February 21, 2011 Accepted for publication: April 7, 2011 Abstract. A requirement for the linear elastic structural concrete wall analysis is represented by the error control during the modeling. The analyst must be aware of the consequences coming from choosing from the diverse design models and take decisions accordingly, in order to maintain the error level as low as possible. The paper is dedicated to the study of some of these errors and investigate their magnitude in few representative cases. Key words: shear walls; concrete walls; coupled walls; structural design; finite element model; shell model; frame model; design method; design errors. 1. Introduction Linear elastic practical modeling of reinforced concrete shear walls is made by idealizing the walls and coupling beams using frame or shell finite elements. Analysing these structures calls for choosing the type of idealizations that would approximate with satisfactory precision the real structure behaviour. The challenge for the analyst is then to maintain the modelling errors at as low level as possible considering the will to fast attain to actual results. * Corresponding author: e-mail: ovidiuchelariu@yahoo.com

42 Ovidiu Chelariu, Ioan-Petru Ciongradi and Mihai Budescu 2. Objectives and Scope of Work The paper wants to show out some errors that could appear through modeling of reinforced concrete shear wall structures in the linear elastic domain and to investigate their magnitude in few representative cases. In Fig. 1 are shown two plane design models witch are frequently used for shear walls with overlapped openings. a b c Fig. 1 a Real structure; b equivalent frame idealization; c shell elements idealization. 3. Designing Hypotesis In order to analyse the errors, there are compared some models of structural walls with a precise model for each situation, so called exact model. The comparison is made on the main results for the structural analysis, such as maximum displacements and forces. Since the purpose of the documentation is to analyse errors in elastic domain, the differences between results will be important, rather than their actual values. In the following steps the wall thickness, their total height and the elastic characteristics of the material are considered constant. Loads are applied concentrated at the slab level. The computation was made in structural design program Etabs, using finite elements having each node six degree of freedom (although there have been used only degrees of freedom in the plan).

Bul. Inst. Polit. Iaşi, t. LVII (LXI), f. 2, 2011 43 3.1. Solid Shear Wall Modeling For start there is considered an example of a solid shear wall having a structure with one level, subjected to superior part by a horizontal concentrated load equal with 1,000 kn (Fig. 2). F = 1,000 kn H = 12 m h = 36 m/24 m/12 m/8 m/6 m/4 m/3 m/2 m b = 0.60 m E = 3 10 7 kn/m 2 ν = 0.2 Fig. 2 Solid shear wall. Model 1A presents a fixed bar (vertical cantilever), 1B presents a finite element, shell type, without mesh, 1C is obtained meshing the previous model in a sufficient number of finite elements, to be considered the exact model (Fig.3). Fig. 3 Computation models for solid shear wall.

44 Ovidiu Chelariu, Ioan-Petru Ciongradi and Mihai Budescu The number and shape of the considered finite elements were chosen for model 1C according to the following principle: the elements have almost square shape and lead to a difference of displacement (maximum) of 1% less than the maximum displacement obtained by dividing the model into four elements, each finite element of the considered model. Maximum displacement of the models with finite elements was given as arithmetic average for horizontal displacements of the nodes situated on the upper side of the wall (Eurocode 8, 2003). Because the maximum displacement in case of model 1A can be directly computed with the relationship presented below, it is observed that the total displacement is obtained by summing the displacement from bending and shear, displacement whose variation is directly influenced by solid wall size, H/h. In accordance with the chosen model, the ratio H/h takes the values 1/3; 1/2; 1/1; 1,5/1; 2/1; 3/1; 4/1; 6/1. Consequently Δ 1A = Δ M + Δ V 3 FH = 3EI + 1.2 FH GA = 0.222 H h 3 + 0.160 H h, [ mm] 3.2. Results for Solid Shear Wall Table 1 presents the maximum displacements and errors obtained for the three types of models depending on different values of the ratio H/h, emphasizing the value of displacements from bending and shear for the model 1A. Table 1 Displacements and Errors for the Models of Solid Shear Wall H/h Error Error ΔM ΔV Δ 1A Δ 1B Δ 1C Δ mm mm mm mm mm 1A Δ 1B % % 0.33 0.008 0.053 0.061 0.049 0.079 27.93 61.23 0.5 0.028 0.080 0.108 0.194 0.300 178.7 55.07 1.0 0.222 0.160 0.382 0.288 0.394 3.01 36.63 1.5 0.749 0.240 0.989 0.742 0.989 0.03 33.29 2.0 1.776 0.320 2.096 1.572 2.079 0.81 32.25 3.0 5.994 0.480 6.474 4.856 6.405 1.07 31.90 4.0 14.208 0.640 14.848 11.141 14.713 0.91 32,06 6.0 47.952 0.960 48.912 36.711 48.434 0.98 31.93

Bul. Inst. Polit. Iaşi, t. LVII (LXI), f. 2, 2011 45 3.3. Shear Wall with Overlapped Openings Model There is considered a wall with overlapped openings (Fig.4), subjected to horizontal loads similar to those produced by an earthquake. Equivalent static loads act at floor level (the upper edge of the coupling beam) and are simple distributed according to the first mode of vibration. H = 4H S =12 m; H S = 3 m b w = b b = 0.2m h w1 = h w2 = h w l b = 2 m E = 3 10 7 kn/m 2 ; ν = 0.2 Wall h w, [m] h b, [m] 1 6 0.25 2 5 0.5 3 4 0.75 4 3 1 5 2 1.5 6 1 2 Fig. 4 Structural wall with overlapped openings. Model 2A is obtained by the equivalent frame method; the two walls and coupling beams are idealized by bars having infinite rigid parts at the end, in discontinuity regions (Fig. 5). Model 2B is obtained using shell finite elements, with minimum mesh (Fig. 6). Model 2C ( exact ) is obtained by meshing walls and coupling beams based on the same principles used for model 1C (Fig. 7). At coupled walls the displacements and the stresses depend not only on the bending and shear rigidity of the walls and coupling beams, but also on their rigidity at tension compression. As result, in case of shear wall with openings, the variable chosen for comparison should be a parameter that indicates the coupling degree of the solid walls through the coupling beams. The degree of coupling and its influence has been studied up to now in different ways corresponding computation methods. For example, there was considered size/layout/openings percentage of the shear wall or the ratio between rigidity of the solid shear walls and of the coupling beams.

46 Ovidiu Chelariu, Ioan-Petru Ciongradi and Mihai Budescu Fig. 5 Model 2A. Fig. 6 Model 2B. Fig. 7 Model 2C.

Bul. Inst. Polit. Iaşi, t. LVII (LXI), f. 2, 2011 47 It is proposed, in this paper, as an index (Paulay et al., 1990), named degree of coupling the ratio C = NL/M, where M = M 1 + M 2 + NL. Index values of the coupling degree are obtained considering six variants of shear walls obtained according with the table in Fig.4, considering the association between the different dimensions of the solid walls/coupling beams as follows: a) are constant the height of the walls, the span of the coupling beams and the level heights; b) it is considered the following options for the high of the coupling beams: h b = l b /8; 2l b /8; 3l b /8; 4l b /8; 6l b /8; 8l b /8 (where l b is the span of the coupling beams). The span of the coupling beams, l b, was chosen so that for 1.5l b to have total coupling (1.5l b = H s, where H s is the height of the level); c) the considered options for the sectional height of the solid walls were established by taking into account the ratio h w /H to have the values 6/12; 5/12; 4/12; 3/12; 2/12; 1/12. Increasing the section height of the columns, h w, was made to the exterior of the wall, so that the span of the coupling beams remains constant. The reactions (forces) at the base of the wall are computed by summing /reducing the nodal forces in the center of gravity of the section. It is preferred this option because by integrating the stresses it can be obtained values that do not provide perfect equilibrium with external forces, which could affect the comparison of errors. 3.4. Obtained Results for Shear Walls with Openings Table 2 presents the maximum displacements and errors obtained for the three models depending on the coupling index NL/M ratio, computed for model 1C. In Tables 3 and 4 are presented the maximum values of reaction forces, N and M, and corresponding errors obtained at the base section of the wall for considered models, depending on the coupling index values NL/M. Table 2 The Displacements and Errors for Shear Walls with Overlapped Openings Δ NL/M L, [m] 2A Δ 2B Δ 2C Error Δ 2A Error Δ 2B mm mm mm % % 0.06 8 1.892 1.203 1.879 0.7 56.3 0.28 7 2.125 1.334 2.219 4.4 66.4 0.45 6 2.501 1.693 2.779 11.1 64.1 0.62 5 2.994 2.566 3.678 22.8 43.3 0.80 4 4.038 4.765 5.730 41.9 20.3 0.90 3 8.496 14.158 15.614 83.8 10.3

48 Ovidiu Chelariu, Ioan-Petru Ciongradi and Mihai Budescu Table 3 Values of the Maximum Reaction Forces, N ( Axial Force at the Base Sections of the Walls), for Shear Walls with Overlapped Openings NL/M L, [m] N 2A kn N 2B kn N 2C kn Error N 2A % Error N 2B % 0.06 8 53 406 68 28.3 83.3 0.28 7 330 679 359 8.8 47.1 0.45 6 705 950 681 3.4 28.3 0.62 5 1,127 1,292 1,119 0.7 13.4 0.80 4 1,730 1,841 1,753 1.3 4.8 0.,90 3 2,686 2,729 2,700 0.5 1.1 Table 4 Maximum Reaction Force Values, M (Overtuning Moment Reactions at the Wall Base), for Shear Walls with Overlapped Openings. Value of M was Obtained with the Relation M = M 1 +M 2 +NL, where M 1 and M 2 are Overtuning Reaction Moments at the Wall Base NL/M L, [m] M 2A kmm M 2B knm M 2C knm Error M 2A % Error M 2B % 0.06 8 8,586 4,844 8,457 1.5 74.6 0.28 7 6,688 4,245 6,483 3.1 52.7 0.45 6 4,758 3,296 4,908 3.2 48.9 0.62 5 3,400 2,538 3,404 0.1 34.1 0.80 4 2,033 1,632 1,985 2.4 21.6 0.90 3 992 812 899 9.4 10.7 4. Conclusions At solid shear wall is observed near perfect correlation between the maximum displacements corresponding to vertical cantilever model ( 1A ) and the reference model ( 2C ) for ratio values H/h > 1, regardless the value of the bending and shear deformations. In this domain model 1B gives large errors of over 30% due the lack of discretization. In domain H/h < 1 is observed high values of the errors for both models. On this domain is recommended the exclusive use of the exact model for analysis in which displacements has an important role. At shear walls with overlapped openings are observed important differences between maximum displacement of the reference model ( 2C ) and those corresponding to the other models. In case of the model with equivalent frame ( 2A ), these differences are the consequences of the fact that the infinite rigid areas do not contribute at general displacement. Therefore, to compute displacements it should assign to these areas a proper rigidity. At the model

Bul. Inst. Polit. Iaşi, t. LVII (LXI), f. 2, 2011 49 with minimum mesh ( 2B ) the difference arises from insufficient discretization, the bending deformation being insufficiently emphasized. From errors analysis of reaction forces at the section base can be noticed a very good correlation between the reference model ( 2C ) and equivalent frame model ( 2A ) for coupling index values between 0.45 and 0.80. For the rest of domain, for weak or strong couplings, it is recommended the exact model ( 2C ). The minimum mesh model ( 2B ) presents large errors regardless the coupling degree, from insufficient discretization. REFERENCES Agent R., Postelnicu T., Calculul structurilor cu diafragme din beton armat. Vol. I, Edit. Tehnică, Bucureşti, 1983. Diaconu M., Teoria aplicată a elasticităţii liniare. Vol. I, II, Edit. Cermi,1999. Paulay T., Bachmann H., Moser K., Erdbebenbemessung von Stahlbetonhochbauten. Birkhäuser Verlag, Basel, 1990. Rombach G.A., Finite Element Design of Concrete Structures. Thomas Telford, London, 2004. Smith B.S., Coull A., Tall Building Structures: Analysis and Design. John Wiley & Sons, Inc., NY, 1991. * * * Design of Structures for Earthquake Resistance. Eurocode 8, 2003. * * * Technical Papers, Design Manuals. Comp. A. Struct. Inc., ETABS, Univ. Avenue Berkeley, California, 2010. ERORI LA MODELAREA ELASTICĂ A STRUCTURILOR CU PEREŢI STRUCTURALI DIN BETON ARMAT (Rezumat) O necesitate în analiza structurilor cu pereţi structurali din beton armat este reprezentată de controlul erorilor de modelare în domeniul liniar elastic. Analistul trebuie să cunoască consecinţele care decurg din alegerea diferitelor modele de calcul şi să ia decizii care să ducă la menţinerea erorilor la un nivel cât mai scazut. Se urmareşte evidenţierea unelor dintre aceste erori şi investigharea dimensiunilor acestora în câteva cazuri reprezentative.