Cable Tracking System Proposal. Nick Friedman Experimenta1 Facilities Division. June 25,1993. Advanced Photon Source Argonne National Laboratory

Similar documents
PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

Plasma Response Control Using Advanced Feedback Techniques

PROJECT PROGRESS REPORT (06/16/1998-9/15/1998):

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

Magnetic Measurements of the Elliptical Multipole Wiggler Prototype

APPLICATION SINGLE ION ACTIVITY COEFFICIENTS TO DETERMINE SOLVENT EXTRACTION MECHANISM FOR COMPONENTS OF NUCLEAR WASTE

The photoneutron yield predictions by PICA and comparison with the measurements

Data Comparisons Y-12 West Tower Data

RESEARCH OPPORTUNITIES AT THE CNS (Y-12 AND PANTEX) NUCLEAR DETECTION AND SENSOR TESTING CENTERS (NDSTC)

Experimental Facilities Division, Advanced Photon Source, Argonne National Laboratoty, Argonne, Illinois 60439

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

ust/ aphysics Division, Argonne National Laboratory, Argonne, Illinois 60439, USA

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Excitations of the transversely polarized spin density. waves in chromium. E3-r 1s

(4) How do you develop an optimal signal detection technique from the knowledge of

EXPLOSIVE PARTICLES PARVLENE ENCAPSUTION. lac0 b Sando v a t. Normal Process Development OCTOBER DEVEZOPMENT D I V I S I O N DEZEMBER 1971

Use of Gamma Rays from the Decay of 13.8-sec "Be to Calibrate a Germanium Gamma Ray Detector for Measurements up to 8 MeV

Comparison Between Various Beam Steering Algorithms for the CEBAF Lattice* INTRODUCTION. SVD Based Algorithm

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

Three-Dimensional Silicon Photonic Crystals

ION EXCHANGE SEPARATION OF PLUTONIUM AND GALLIUM (1) Resource and Inventory Requirements, (2) Waste, Emissions, and Effluent, and (3) Facility Size

OAK RIDGE NATIONAL LABORATORY

12/16/95-3/15/96 PERIOD MULTI-PARAMETER ON-LINE COAL BULK ANALYSIS. 2, 1. Thermal Neutron Flux in Coal: New Coal Container Geometry

Quench Propagation Velocity for Highly Stabilized Conductors

Plutonium 239 Equivalency Calculations

Measurement of Low Levels of Alpha in 99M0Product Solutions

ASTER. Dose Rate Visualization of Radioisotope Thermoelectric. Generators. RECElVED BEC OF THIS DOCUMEMT IS UNLlMIi L, Hanford Company

K.M. Hoffmann and D. C. Seely

A Few-Group Delayed Neutron Model Based on a Consistent Set of Decay Constants. Joann M. Campbell Gregory D. Spriggs

Experiment. The Pinhole Neutron. Pinex. c. c. sartain UCRL-ID November 21,1958

EFFECTS OF AXIAL HEAT CONDUCTION AND MATERIAL PROPERTIES ON THE PERFORMANCE CHARACTERISTICS OF A THERMAL TRANSIENT ANEMOMETER PROBE

9 7og$y4- International Conference On Neutron Scattering, Toronto August Spin Dynamics of the reentrant spin glass Fe0.7A10.3.

Abstract of paper proposed for the American Nuclear Society 1997 Winter Meeting Albuquerque, New Mexico November 16-20, 1997

Walter P. Lysenko John D. Gilpatrick Martin E. Schulze LINAC '98 XIX INTERNATIONAL CONFERENCE CHICAGO, IL AUGUST 23-28,1998

National Accelerator Laboratory

SPHERICAL COMPRESSION OF A MAGNETIC FIELD. C. M. Fowler DISCLAIMER

sample-specific X-ray speckle contrast variation at absorption edges $ & ~ 0

Summary Report: Working Group 5 on Electron Beam-Driven Plasma and Structure Based Acceleration Concepts

J. R Creighton and C. M. Truong Org. 1126, MS 0601 P.O. Box 5800 Sandia National Laboratories Albuquerque, NM

Tell uric prof i 1 es across the Darrough Known Geothermal Resource Area, Nevada. Harold Kaufniann. Open-file Report No.

Magnetic Resonance Imaging of Polymer Electrolytes and Insertion Electrodes*

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Microscale Chemistry Technology Exchange at Argonne National Laboratory - East

4kU. Measurement of Storage Ring Motion at the Advanced Light Source. QSTt ERNESTORLANDO LAWRENCE BERKELEYNATIONAL LABORATORY

Survey, Alignment and Beam Stability at the Advanced Light Source

DE '! N0V ?

AC dipole based optics measurement and correction at RHIC

BASAL CAMBRIAN BASELINE GEOLOGICAL CHARACTERIZATION COMPLETED

m w n? r i OF,THISDOCUMENT IS UNLIMITED

IMAGING OF HETEROGENEOUS MATERIALS BY. P. Staples, T. H. Prettyman, and J. Lestone

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

CQNl_" RESPONSE TO 100% INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES TO LOW ENERGY ELECTRONS AND IONS

~ _- IDOCLRXKT DMSP SATELLITE DETECTIONS OF GAMMA-RAY BURSTS. J. Terrell, NIS-2 P. Lee, NIS-2 R W.

Development of a High Intensity EBIT for Basic and Applied Science

UNDERSTANDING TRANSPORT THROUGH DIMENSIONLESS PARAMETER SCALING EXPERIMENTS

Scaling between K+ and proton production in nucleus-nucleus collisions *

Use of AVHRR-Derived Spectral Reflectances to Estimate Surface Albedo across the Southern Great Plains Cloud and Radiation Testbed (CART) Site

August 3,1999. Stiffness and Strength Properties for Basic Sandwich Material Core Types UCRL-JC B. Kim, R.M. Christensen.

8STATISTICAL ANALYSIS OF HIGH EXPLOSIVE DETONATION DATA. Beckman, Fernandez, Ramsay, and Wendelberger DRAFT 5/10/98 1.

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

PRECISION STUDIES OF NUCLEI

bservice de Physique Nue16aire, CEA-Saclay, F Gif-sur-Yvette Cedex, Ii?ance

A NEW TARGET CONCEPT FOR PROTON ACCELERATOR DRIVEN BORON NEUTRON CAPTURE THERAPY APPLICATIONS* Brookhaven National Laboratory. P.O.

RESONANCE INTERFERENCE AND ABSOLUTE CROSS SECTIONS IN NEAR-THRESHOLD ELECTRON-IMPACT EXCITATION OF MULTICHARGED IONS

J. T. Mihalczo. P. 0. Box 2008

Laser-Modulator System

The temperature dependence of the C1+ propylene rate coefficient and the Arrhenius fit are shown in Figure 1.

Diffractive Dijet Search with Roman Pots at CDF

Manifestations of the axial anomaly in finite temperature QCD

GA A25658 PRECISION X-RAY OPTICAL DEPTH MEASUREMENTS IN ICF SHELLS

Centrifugal Destabilization and Restabilization of Plane Shear Flows

DETECTING AND QUANTIFYING LEWISITE DEGRADATION PRODUCTS I N ENVIRONMENTAL SAMPLES USING ARSENIC SPECIATION*

Hyperon Particle Physics at JHF. R. E. Mischke

GA A26474 SYNERGY IN TWO-FREQUENCY FAST WAVE CYCLOTRON HARMONIC ABSORPTION IN DIII-D

RUDOLPH J. HENNINGER, XHM PAUL J. MAUDLIN, T-3 ERIC N. HARSTAD, T-3

Analysis of Shane Telescope Aberration and After Collimation

SOME ENDF/B-VI MATERLALS. C. Y. Fu Oak Ridge National Laboratory Oak Ridge, Tennessee USA

GA A24166 SUPER-INTENSE QUASI-NEUTRAL PROTON BEAMS INTERACTING WITH PLASMA: A NUMERICAL INVESTIGATION

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

STP-TS THERMOPHYSICAL PROPERTIES OF WORKING GASES USED IN WORKING GAS TURBINE APPLICATIONS

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

Variational Nodal PerturbationCalculations Using Simplified Spherical HarmonicsO

PLASMA MASS DENSITY, SPECIES MIX AND FLUCTUATION DIAGNOSTICS USING FAST ALFVEN WAVE

: Y/LB-16,056 OAK RIDGE Y-12 PLANT

MAGNETIC RESONANCE IMAGING OF SOLVENT TRANSPORT IN POLYMER NETWORKS

in the pinch. This paper describes the computer modeling behind the shielding design of a

The Radiological Hazard of Plutonium Isotopes and Specific Plutonium Mixtures

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

National Accelerator Laboratory

RWM FEEDBACK STABILIZATION IN DIII D: EXPERIMENT-THEORY COMPARISONS AND IMPLICATIONS FOR ITER

INTERMOLECULAR POTENTIAL FUNCTIONS AND HIGH RESOLUTION MOLECULAR SPECTROSCOPY OF WEAKLY BOUND COMPLEXES. Final Progress Report

STI. ANL-HEP-CP June 10, 1997 ISOLATED PROMPT PHOTON PLUS JET PHOTOPRODUCTION AT HERA a

Multi-Scale Chemical Process Modeling with Bayesian Nonparametric Regression

Start-up Noise in 3-D Self-AmpMed

N. Tsoupas, E. Rodger, J. Claus, H.W. Foelsche, and P. Wanderer Brookhaven National Laboratory Associated Universities, Inc. Upton, New York 11973

Turbulent Scaling in Fluids. Robert Ecke, MST-10 Ning Li, MST-10 Shi-Yi Li, T-13 Yuanming Liu, MST-10

Colliding Crystalline Beams

Using the X-FEL to understand X-ray Thomson scattering for partially ionized plasmas

Contractor Name and Address: Oxy USA, Inc. (Oxy), Midland, Texas OBJECTIVES

DISCLAIMER BASIN, WEST TEXAS AND NEW MEXICO

Transcription:

LS224 by i contractor of the U.S Government under contract No. W31104ENG38. Accordingly, the U. S Government retains a nonexclusive, royaltyfree license to publish or reproduce the published form d this contribution, or allow others to do w, for Cable Tracking System Proposal Nick Friedman Experimenta1 Facilities Division DSCLAMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. June 25,1993 Advanced Photon Source Argonne National Laboratory

DSCLAMER Portions of this document may be illegible in electronic image products. mages are produced from the best available original document.

CABLE TRACKNG SYSTEM PROPOSAL Nick Friedman Experimental Facilities Division Advanced Photon Source October 19, 1992. ntroduction The Experimental Facilities Division requires a labeling system to identify and catalog the instrumentation, control, and computer cables that will run throughout the building. Tom Sheridan from the MS Group has already made some general suggestions about the information that could be included in an Oraclebased Cable Tracking System (Email text distributed by Gary Gunderson on the 27th of August). Glenn Decker s LS Note No. 191 is also relevant to the subject since it addresses name assignment rules for the storage ring devices. The intent of this note is to recommend a mechanism for tracking wiredcables, with enough specifics, to which all groups in the Division would adhere when pulling cables. Because most cables will run between various beamline devices, hutch safety components, and equipment racks, any method of tracking cables is related to the Fquipment Tracking System. That system has been developed by the APS Project personnel and is described in the APS Project Equipment Tracking System Guidelines (DRAFT).t can be adopted to XFD s needs. Two essential features of the Cable Tracking System are: 1) Each cable shell have a unique dentifier, and 2) Cable label must contain information that is helpful during troubleshooting in the field. The dentifier is an alphanumeric string of characters that will originate in the Oraclebased Cable Tracking System. t is not necessary for the identifier to carry a lot of intelligence its primary purpose is simply to provide a link to the database. Barcoding the dentifier would make it easy to combine cable information with the Equipment Tracking System. Oracle database, running under VAXNMS operating system, is a multiuser projectwide system. As such, it will eliminate the possibility of duplicate entries. Additional benefits are expected from the ease of interface to the Equipment Tracking System, which is based in Oracle. For the purpose of troubleshooting, it is very helpful to be able to access detailed cable data while working in any area of the experimental floor. A laptop computer equipped with an Ethernet interface card will provide such capability. Page of 6

11. General Labeling Rules Each cable label will consist of three rows. The first row is the Cable dentifier assigned for each Group by the Oraclebased Cable Tracking System. The second row, System dentifier, states to which system the cable belongs, for example, PLC 1st Ph. Shutter or PLC FOE Rad. Safety. The third line, let s call it Location dentifier, identifies the source, destination, and termination type of the cable. More specific information about terminal plock pins may be included on this line to facilitate quick location. All three lines can be customized to include additional information as found appropriate by the individual Groups the System will prevent the use of duplicate dentifiers.. Cable Labeling Standards 1. Cable dentifier will consist of a two character group identifier followed by a sixdigit number, for example, EC000221 or D000093. 2. System dentifier is the second line, beneath the Cable dentifier. t describes to what system the cable belongs. This is an English description of what the cable is used for. For example, Connects 2nd Ph. Shutter to PLC, or Fast Valve Sensor to Controller (40character max). 3. Location dentifier, the third line on the label, will consist of two codes which refer to the point of origin and the location of the destination of the two ends of the cable. Each end of the cable is described by a sevenfield code. The line will consist of two codes separated by a dash (). An example of this line would be: 1!B _ 2 ; : T B 2 1 : 7, 8 1 2 B M l K : P L 5 : 2, 3 Pin numbers B l o c k number CPL P l u g ) Section of t h e S e c t o r n d i c a t e s the L e v e l B e n d i n g Magnet Sector number ig. 1 Page 2 of 6

Below is an example of a cable labeled with this system: Cable E q u i p m e n t No. EC12BM002 1 PS2 to PLC Chain A 12BUZFE:TB21:7.8 1ZBYlFE:PU :2.3 E q u i p m e n t No. EC12BY0045 PS2 t o PLC Chain A 12BYlFE :PLS:2.3 \ CL aa bb leel s Ends on / \ l2byzfb:tb21 r 7. 8 Fig. 2 Page 3 of 6

Next, to define the Location dentifier more precisely, we'll use the same example as above. f t h a c a b l a i s a t t a c h e d t o beamline d a v i c a t h e n t h e s e 3 f i e l d s s h o u l d be r e p l a c e d by t h e b e a r l i n e d e v i c e nape p r e c e d e d by a s l a s h. f 1 B Y : F V r e p l a c e s lzbyz C N e.g.. F a s t Valve). f t h e c a b l e i s a t t a c h e d t o s o m e t h i n g i n a r a c k and t h a t r a c k a l r e a d y h a s a l a b e l a s s i g n e d t o i t t h e n u s e i t s l a b e l i n place of t h e s e 4 f i e l d s. f a r a c k Ens PO l a b e l t h e n u s e t h e r e six c h a r a c t e r s t o assign one f o l l o w i n g t h e r u l e s b e l o v T h i s f i e l d C 2 c h a r a c t e r s > i n d i c a t e s Sector number U s e t h i s f i e l d t o i n d i c a t e t h e t y p e of a b e a m l i n e BLL Bending YPgnet. D n s e r t i o n Device. T h i s numbis t h a f l o o r l e v e l : 1 = Kain Floor 2 S t o r a g e x n g Roof 3 = Above R o o f Lave1 C R a f t s r. e t =. > 4 Basement 12 B M 2 FE : TB 21 7,i D e s i g n a t i o n of t h i s f i e l d is a s f o l l o w s : FE = F r o n t End FOE F i r s t Optics Enclosure BL = B e a m Line etc. A c o l o n is used i s o delizaitet TB Use +o s e p a r a t e f i e l d s when a d j a c e n t f i e l d s are b o t h l e t t e r s or b o t h No. T e r m i n a l B l o c k. PL Plug '00' i f t h r e r e is no p l u g n o r t e r m i n a l block T h i s is the P l u s or T e r m i n a l Block number This f i e l d i n d i c a t e s p i n number. t c a n b e longer t h a n 2 c h r r r c t e r s. t Page 4 of 6

V. Cable Definition Data Form At this point, it is not necessary to establish strict procedures for pulling and labeling cables. However, it is important to emphasize that a Cable Definition Data Form must be filled out, to the extent possible, before actually pulling the cable. This Form has to be completed immediately after cable terminations are made. An example of such form is shown below. S a b l e D e f i n i t i o n Data F o r m Cable Label AEnd T e r m. No. Date Database N o. / BEnd T e r m. No. Sheet Author of Cable F u n c t i o n System AEnd C a b l e Type Connector Location BEnd C o n n e c t o r Location Pin C o r r e s p o n d e n c e Wire C o l o r / No. AEnd Pin N o. BEnd P i n No. W i r e Signal Description Fig. 4 Page 5 of 6

V. Database Program The Cable Definition Data Form serves as the main source of information for entering data into the database system. Types of pertinent information to store in the database can be: Cable dentifier Code Cable Size Number of Conductors Wire Color Code nsulation Material and Rating Connector Type and Pinout Function System Cable Serves Resistance to Radiation Date nstalled Wireway: Tray, Conduit nformation Drawings Numbers Problems Observed Comments EtC. Page 6 of 6