Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Similar documents
Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Agilent Application Solution Analysis of acaricides in honey. Authors. Abstract. Food

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Modernizing the USP Monograph for Acetaminophen

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Fast methods for the determination of ibuprofen in drug products

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

The new Agilent 1290 Infinity Quaternary LC

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

The Agilent 1290 Infinity II Multi Method Solution

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

ENVIRONMENTAL analysis

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Agilent LC & LC-MS Cannabis Testing

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Automated Sample Preparation in Quality Control of Eye-Drop Formulation

Application. Gas Chromatography February Introduction

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

CIPAC. CIPAC Free relevant impurities methods:

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Routine MS Detection for USP Chromatographic Methods

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Application Note. Authors. Abstract. Food Testing & Agriculture. Stephen E. Reichenbach University of Nebraska Lincoln, NE, USA

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Analysis of Positional Isomers with Agilent Poroshell 120 PFP Columns

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Application Note. Abstract. Authors. Pharmaceutical. William J. Long Agilent Technologies, Inc Centerville Road Wilmington, DE USA

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

*Correspondence to:

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

CHEM 429 / 529 Chemical Separation Techniques

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Transcription:

Analytical Quantification of Deoxygenated Compounds in Catalytic Reaction Samples as an Evaluation Technique to Detere Reaction Conversion from a Bioderived Oil in Novel Biofuel Testing Application Note Energy & Chemicals, Biofuels & Alternative Energy Authors Dr. Andrés Granados Fócil Universidad Autónoma Metropolitana (UAM) Iztapalapa, Mexico City, Mexico Karen Lorena López Agilent Technologies, Inc. Mexico City, Mexico Abstract This Application Note describes an HPLC method to simultaneously separate and identify deoxygenated compounds from a guaiacol catalytic reaction to evaluate the conversion rate under varied reaction conditions, as part of the novel catalysis processes to obtain renewable biofuels from bioderived oils. The proposed methodology was applied to two different reaction batches, 13 samples were collected to quantify the efficiency of the catalyst proposed. A comparison between a GC method and the one proposed in this Application Note demonstrates time savings with the LC technique as a quality control measurement that could be implemented in biofuel manufacturing process stages.

Introduction Dwindling crude oil reserves, accompanied by rising prices and environmental concerns, have led to increased interest in the use of renewable fuels. Biofuels produced from waste agricultural or forestry material are desirable because they avoid diverting resources from the production of food crops. Oils produced by high temperature treatment of these waste materials, however, contain a large number of oxygenated compounds that result in undesirable properties such as high viscosity and corrosiveness. New approaches describe a series of catalysts that might be used to upgrade these oils by removing the undesirable oxygen-containing functional groups. The compound guaiacol is being used as a model for oxygenated bioderived oils. Guaiacol provides, in a single and easily available compound, the types of oxygen containing functional groups that typically need to be removed. Depending on the catalyst used, varied rate conversions of guaiacol can be obtained. The one proposed in this methodology is rhodium supported in HY zeolite. Chromatographic techniques have been used effectively to identify and quantify this type of compound. Although GC has always been considered as the primary technique, long run times are common, in addition to the equilibration time needed. Alternatively, an LC technique can be used to reduce run times by half, while being able to identify some of the compounds of interest with excellent reproducibility, using solvents more friendly to the environment. Experimental Equipment The Agilent 126 Infinity II LC system used for the experiments comprised the following modules: Agilent 126 Infinity II Quaternary Pump (G714A) Agilent 126 Infinity II Vialsampler (G7167B) Agilent 126 Infinity II Multicolumn Thermostat (G7116B) Agilent 126 Infinity II Variable Wavelength Detector (G4212B) Software Agilent OpenLAB CDS ChemStation Edition, version C.1.7 Column Agilent ZORBAX Eclipse Plus C18, 4.6 1 mm, 3. µm (p/n 99961-92) Chemicals All solvents were LC grade. Acetonitrile was purchased from J.T. Baker, USA. Ultrapure water was LC-grade purchased from J.T. Baker, USA. Samples and sample preparation Six compounds were obtained as individual standards from Sigma-Aldrich: anisole, benzene, toluene, o-xylene, m-xylene, and guaiacol. Each compound was mixed to reach a final concentration of 2, ppm, and labeled as the standard mix solution. From this standard mixture, three dilutions in hexane were performed to obtain a four-level calibration curve, including the stock solution, with the concentrations 1,,, and 1 ppm. Reaction samples were placed into a vial for HPLC injection after being collected under varied reaction conditions such as temperature ( C) and flow of reactive (ml/). Table 1 shows the detailed list of conditions for the 13 total reaction samples. Table 1. Catalytic reaction conditions for each sample. Sample Temperature ( C) RXN_1 1. RXN_2 1 2. RXN_3 1. RXN_1 2 6. RXN_2 2 6.3 RXN_3 2 7. RXN_4 2 1.3 RXN_1 2 11.3 RXN_2 2 11.9 RXN_3 2 12.9 RXN_4 2 16.3 RXN_1 2 17. RXN_2 2 18. Reaction time (hours) 2

Chromatographic conditions The separation was achieved using a binary linear elution gradient with (A) water and (B) acetonitrile. Table 2 shows the chromatographic conditions for the HPLC gradient. Results and Discussion A mix of six standard compounds was separated using an HPLC binary gradient. The relative standard deviation (RSD) of retention time (RT) and area were evaluated over seven subsequent runs. Figure 1 shows the results of the separation. The analysis showed excellent precision of RT and area. The RSD for RT was <.2, and the area RSD was < 2. for all standard compounds. Table 2. Chromatographic conditions, HPLC gradient. Parameter Value Binary gradient Time () A: Water B: Acetonitrile. 9.. 1. 77. 23. 11. 2. 8. 13. 2. 8. 14. 9.. Stop time Post time Flow rate Injection volume 1 µl Sample temperature 17. utes 2. utes.6 ml/ Ambient Column temperature 6 C Detection 1,7 27 nm, peak width >.1 utes (2 second response time), Hz 1 2 1, 1,2 1, 7 2 3 4 6 2 4 6 8 1 12 14 16 Peak no. Compound % RSD RT % RSD area 1 Guaiacol.2 1.732 2 Anisole.2.634 3 Benzene.284.7262 4 Toluene.6 1.3988 o-xylene.7.3721 6 m-xylene.4.8718 Figure 1. Chromatogram obtained by HPLC gradient for the Standard Mix sample where the six compounds are separated. 3

The Standard mix solution was diluted from 2, ppm down to ppm to obtain the calibration curve. Table 3 shows the results of the evaluation for the HPLC method. The 13 samples collected at varied reaction conditions were analyzed. The deoxygenated compound content was quantified by external standard method. Comparison with the results previously obtained by a GC method was performed. Some of the samples, which showed a high conversion, occurred under high temperature and longtime reaction, such as the RXN2_2C, RXN4_2C, and RXN7_2C. Consistently, two compounds apart from guaiacol were quantified in these samples: m-xylene with a total quantification range from 33 to 3 ppm, and o-xylene from 28 to 3 ppm. Figure 2 shows the chromatograms corresponding to these samples. Table 3. Linearity results for HPLC conditions. Compound Guaiacol.98929 Anisole.98996 Benzene.97918 Toluene.9861 o-xylene.9928 m-xylene.98686 - -1-1 A RXN_2_2C B RXN_4_2C Correlation coefficient UHPLC 2 4 6 8 1 12 14 16 - -1-1 1 C RXN_7_2C 2 4 6 8 1 12 14 16 - -1-1 2 4 6 8 1 12 14 16 Figure 2. Chromatograms of three different reaction samples collected at the same temperature (2 C). 4

Toluene and anisole were only identified under lower temperature conditions (1 C) and shorter reaction times; however, conversion kept decreasing until the temperature was raised again. Quantification for these two compounds ranged from 8 to 1,1 ppm for toluene, and approximately 2 ppm for anisole. Figure 3 presents an example of one sample reaction at this temperature condition. After quantification, results were obtained and analyzed for every sample, and compared with the results obtained with the implemented GC method. Results were consistent with the GC technique. This was confirmed by reaction conversion calculation, and compared with the LC results obtained in this analysis for the evaluation of conversion of guaiacol. Figure 4 shows the final comparison between the two chromatographic techniques monitoring the conversion of guaiacol. Although both methods are comparable, the analysis time of the HPLC method was considerably shorter. With only 18 utes run time, the separation and quantification was performed precisely, whereas the GC method took approximately 4 utes to accomplish the same goal. 1 8 6 4 2-2 2 4 6 8 1 12 14 Figure 3. Magnification of the chromatogram for the RXN_7_1C sample reaction, collected at 1 C. Conversion of guayacol (%) 1..9.8.7.6..4.3.2.1 1 C, 4 bar WSHV =1. 2 C, 4 bar 2 C, 4 bar WSHV =1. 2 C, 4 bar WSHV =2. 1 C, 4 bar WSHV =1. GC HPLC. 1 2 3 4 6 7 8 9 1, 1,1 1,2 1,3 1,4 1, Reaction time () 1 C, 6 bar WSHV =1. Figure 4. Comparison between LC and GC methods to monitor the conversion of guaiacol.

Conclusion An analytical methodology for the analysis of deoxygenated compounds was developed for HPLC using a binary gradient with the Agilent 126 Infinity II LC. Thirteen reaction samples were collected and analyzed under the described analytical conditions to demonstrate that LC is an effective chromatographic technique for the identification and quantification of compounds involved in biofuel production. This could help increase laboratory productivity with shorter analysis times in comparison with available GC methods. The results obtained with the LC methodology agreed with the ones obtained by traditional GC methods, confirg the variation of guaiacol conversion according to the different reaction conditions tested by researchers so far. The LC technique reduces run times, with excellent reproducibility, and uses environmentally friendly solvents. The technique can be considered an alternative approach to the identification of some of the compounds of interest currently involved in novel approaches developing alternative fuels to overcome the huge day-to-day demand on crude oil reserves. References 1. Kunkes, E. L.; et al. Catalytic conversion of biomass to monofunctional hydrocarbons and targeted liquid-fuel classes, Science 28, 322(9), 417 421. 2. Chang, J.; et al. Hydrodeoxygenation of Guaiacol over Carbon-Supported Metal Catalysts, Chem. Cat. Chem. 213, (1), 341. 3. Mortensen, P. M.; et al. A review of catalytic upgrading of bio-oil to engine fuels, Appl. Catal. A 211, 47, 1 19. 4. Mortensen, P. M.; et al. Screening of Catalysts for Hydrodeoxygenation of Phenol as a Model Compound for Bio oil, ACS Catal. 213, 3, 1774 178.. Nimmanwudipong, T.; et al. Design of a High-Pressure Flow-Reactor System for Catalytic Hydrodeoxygenation: Guaiacol Conversion Catalyzed by Platinum Supported on MgO, Energy Fuels,214, 28, 19 196. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 217 Published in the USA, April 1, 217 991-7948EN