Comparision studies on Adsorbants for removal of Hardness from Water by using newly Prepared Zeolite

Similar documents
Kinetic Studies on Removal of Fluoride from Drinking Water by using Tamarind Shell and Pipal leaf Powder

Current World Environment Vol. 4(2), (2009)

STUDIES ON THE REMOVAL OF CATIONIC DYES FROM AQUEOUS SOLUTION BY MIXED ADSORBENTS

ADSORPTION STUDIES OF CHROMIUM (VI) ON ACTIVATED CARBON DERIVED FROM CASURINA FRUIT

Effect of Process Parameters on Adsorption of Methylene Blue from Synthetic Effluent Using Jack Fruit Seed Powder

Removal of Fluoride from Synthetic Water Using Chitosan as an Adsorbent

Adsorption of chromium from aqueous solution by activated alumina and activated charcoal

Removal of Nickel ions from Aqueous Solutions on Packed bed of Zeolite NaX

ADSORPTION OF MALACHITE GREEN DYE ONTO ACTIVATED CARBON OBTAINED FROM THE NATURAL PLANT STEM

Received: 24 th April-2012 Revised: 07 th May-2012 Accepted: 10 th May-2012 Research article

Adsorption Studies of Organic Pollutants onto Activated Carbon

Removal of Organic Contents from Wastewater Using Leusas aspera

Application of Fe 2 O 3 nanoparticles in Heavy Metal Removal

Kinetic and Isotherm Studies of Removal of Metanil Yellow Dye on Mesoporous Aluminophosphate Molecular Sieves

Adsorption of Acid Orange-7 Dye onto Activated Carbon Produced from Bentonite - A Study of Equilibrium Adsorption Isotherm

Evaluation of adsorptive capacity of natural and burnt kaolinitic clay for removal of congo red dye

Removal of Cd (II) and Cr (VI) from Electroplating Wastewater by Coconut Shell

Adsorption of Humic acid on Powdered Activated Carbon (PAC)

Equilibrium, Kinetics and Isothem Studies onthe Adsorption of Eosin Red and Malachite Green Using Activated Carbon from Huracrepitans Seed Shells

Removal of Vanadium (V) from water by adsorption using GAC loaded with ethylene di-amine tetra acetic acid (EDTA) and nitrilo tri-acetic acid (NTA)

Adsorption Studies of Cyanide (CN) - on Alumina

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 3, Issue 4, July 2014

Research in Chemistry and Environment

EQUILIBRIUM ANALYSIS FOR BATCH STUDIES OF ADSORPTION OF FLUORIDE IN WATER USING ACTIVATED ALUMINA R AND D 651-X

What Do You Think? Investigate GOALS. Part A: Precipitation of Calcium

Activated Carbon from Sugar Waste Bagasse is used for Removal of Colour from Dye Solution

ADSORPTION STUDIES OF SOME DYES ON ACACIA CONCINNA POWDER

EFFECT OF CONTACT TIME ON ADSORPTION OF NITRATES AND PHOSPHATES

REMOVAL OF REACTIVE YELLOW DYE USING NATURAL COAGULANTS IN SYNTHETIC TEXTILE WASTE WATER

ENVIRONMENTAL ENGINEERING. Chemical Engineering department

CHAPTER 3. BATCH STUDIES FOR As(III) REMOVAL FROM WATER BY USING MAGNETITE NANOPARTICLES COATED SAND: ADSORPTION KINETICS AND ISOTHERMS

Developing a Low Cost Activated Carbon from Agricultural Waste for the Removal of Heavy Metal from Contaminated Water

Removal of Direct Red Dye Using Neem Leaf Litter

APPLICATION OF METAKAOLIN GEOPOLYMER FOR AMMONIUM REMOVAL IN SMALL-SCALE WASTEWATER TREATMENT SYSTEMS

Removal of Heavy Metals Fe 3+, Cu 2+, Zn 2+, Pb 2+, Cr 3+ and Cd 2+ from Aqueous Solutions by Using Eichhornia Crassipes

EXPERIMENTAL PROCEDURE

ELIMINATION OF NICKEL (I) FROM SYNTHETIC WASTE WATER USING BAGASSE PITH WITH COLUMN STUDIES

Removal of crystal violet from waste water

Equilibrium and Kinetics of Adsorption of Cationic Dyes by STISHOVITE Clay TiO2 Nanocomposite

IRON AND ALUMINIUM OXIDES POROUS MATERIALS FROM LATERITE: EFFICIENT ARSENIC ADSORBENTS

1997 P a g e. Keywords: Adsorption, banana peel, Colour removal, orange peel

Treatment of a Selected Refinery Wastewater Compound (Benzene) by Chitin and Chitosan by Dr Maryam Mohamed

Supporting Information

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.7, pp , 2015

KINETICS FOR REMOVAL OF FLUORIDE FROM AQUEOUS SOLUTION THROUGH ADSORPTION FROM MOUSAMBI PEEL, GROUND NUT SHELL AND NEEM LEAVES

Removal of Basic Dyes from Aqueous Solutions by Sugar Can Stalks

Adsorption study on pomegranate peel: Removal of Ni 2+ and Co 2+ from aqueous solution

Adsorption of Free Fatty Acid from Crude Palm Oil on Magnesium Silicate Derived From Rice Husk

REMOVAL OF SYNTHETIC DYE ACID RED 186 FROM WATER BY ACTIVATED CARBON. Libya

Katarzyna Zielińska, Alexandre G. Chostenko, Stanisław Truszkowski

Screening of Algae Material as a Filter for Heavy Metals in Drinking Water

GROUNDNUT SHELL: EFFECTIVE ADSORBENT FOR DEFLUORIDATION FROM AQUEOUS SOLUTION

Removal of Metal Iron from Groundwater Using Aceh Natural Zeolite and Membrane Filtration

Removal of Cr(VI) from Wastewater using Fly ash as an Adsorbent

Preparation and Regeneration of Composite of Cationic gel and Iron Hydroxide for Adsorbing Arsenic from Ground Water

Feasibility of Acid Activated Moringa Oleifera Leaves as an Adsorbent for Defluoridation of Water

Adsorption of Fluoride from Drinking Water on Magnesium substituted Hydroxyapatite

Int.J.Curr.Res.Aca.Rev.2016; 4(6): Biosorption of Lead (II), Nickel (II) Iron (II) and Zinc (II) on Flyash from Dilute Aqueous Solution

Chapter 7 Adsorption thermodynamics and recovery of uranium

Batch Adsorption Test of Phenol on Soils

Journal of Babylon University/Engineering Sciences/ No.(4)/ Vol.(25): 2017

RESOLUTION OIV-OENO CONSIDERING the work of the Specifications of Oenological Products Expert Group,

AMMONIA ADSORPTION FROM AQUEOUS SOLUTION USING NATURAL ZEOLITES. Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 31490, Thailand

a variety of living species. Therefore, elimination of heavy metals/dyes from water and

Hexavalent Chromium Removal by Quaternized Poly(4-Vinylpyridine) Coated Activated Carbon From Aqueous Solution

Development of a New Method to Replace the Foam Index Test

CHARACTERIZATION AND DEFLUORIDATION STUDIES OF ACTIVATED DOLICHOS LAB LAB CARBON

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

Acid Orange 7 Dye Biosorption by Salvinia natans Biomass

Effect of different molarities of Sodium Hydroxide solution on the Strength of Geopolymer concrete

Adsorption behavior of methylene blue onto gellan gum-bentonite composite beads for bioremediation application

Journal of Chemical and Pharmaceutical Research, 2012, 4(10): Research Article

CEE 371 Water and Wastewater Systems

Adsorption Studies of Nitrate by Geo-Physical Environment (Laterite soil) of the Study Area Bidar Urban & its Industrial Area, Karnataka State, India

Removal of Arsenic Using Mango, Java Plum and Neem Tree Barks

Department of Civil Engineering-I.I.T. Delhi CVL722 1st Semester HW Set2. Adsorption

Simultaneous Adsorption and Biodegradation of Phenol and Cyanide in Multicomponent System

Journal of Applicable Chemistry 2017, 6 (5): (International Peer Reviewed Journal)

KINETICS AND EQUILIBRIUM STUDY OF ADSORPTION OF PHENOL RED ON TEFF (Eragrostis teff) HUSK ACTIVATED CARBON

Methylene Blue Colour Removal Using Physically And Chemically Activated Cashew Nut Shell Activated Carbon

MASS TRANSFER AND ADSORPTION OF AMOXICILLIN FROM WASTEWATER USING WHEAT GRAIN

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Adsorption

Supporting Information

Reactive fluorescent dye functionalized cotton fabric as a Magic Cloth for selective sensing and reversible separation of Cd 2+ in water

Kinetic Parameters And Evaluation Performance for Decolorization Using Low Cost Adsorbent

The Use of Acacia tortilis Leaves as Low Cost Adsorbent to Reduce the Lead Cations from an Aquatic Environment

REMOVAL OF FLUORIDE IN DRINKING WATER BY GREEN CHEMICAL APPROACH

KENAF FIBRES (Hibiscus Cannabinus) AS A POTENTIAL LOW-COST ADSORBENT FOR WASTEWATER TREATMENT

Biokinetic Study on Chromium Removal from Textile Wastewater Using Azadirachta Indica as a Low Cost Adsorbent

CHAPTER 5. EQUILIBRIUM AND THERMODYNAMIC INVESTIGATION OF As(III) AND As(V) REMOVAL BY MAGNETITE NANOPARTICLES COATED SAND

Characterization of Activated Carbon Prepared from Almond Shells for Scavenging Phenolic Pollutants

FACTFILE: GCSE CHEMISTRY: UNIT 2.6

PREPARATION OF ACTIVATED CARBON FROM PULP AND PAPER MILL WASTES TO BE TESTED FOR THE ADSORPTION OF VOCS

Removal of Copper (II) from Aqueous Solutions using Chalk Powder

Adsorption of Ethylacetate from Ethyl Acetate Water Mixture using Activated Clay

REMOVAL OF HEAVY METALS USING COMBINATION OF ADSORBENTS - A CASE STUDY USING INDUSTRIAL WASTE WATER

ABSTRACT. Keywords: Cadmium Removal, sawdust, adsorption. Corresponding Author: P. Akhila Swathanthra 1. INTRODUCTION:

EXPERIMENTAL STUDY ON THE USE OF CHITOSAN-COATED ACTIVATED CARBON TO REDUCE THE CONTENT OF METAL Fe THE PRODUCED WATER

AIM: To determine the calcium and magnesium hardness in a given water sample Theory:

Chemical Equilibrium

Transcription:

INTERNATIONAL JOURNAL OF ADVANCES IN PHARMACY, BIOLOGY AND CHEMISTRY Research Article Comparision studies on Adsorbants for removal of Hardness from Water by using newly Prepared Zeolite R. Viswanath Goud *, B. Lenin Kumar, N. Abhilash, P. Rajendra Prasad and B. Vijaya saradhi. Department of Chemical Engineering, Andhra University, Visakhapatnam, Andhra Pradesh, India. ABSTRACT Most of the water resources should be treated for purification before consumption. In some countries, ground water is the main safe drinking water resource. About 97% of earth s water is saline and is contained in oceans. Reaming 3% is water. About 68.7% of fresh water is trapped in the ice caps and glaciers, while 30.1 % of fresh water exists in the form of groundwater, 0.3 %in surface water and 0.9% in other form. Adsorbent dose is 6g/L, contact time is 60 minutes by LPZ; Adsorbent dose is 12g/L, contact time is 30 minutes by Commercial Zeolite; Adsorbent dose is 4g/L, contact time is 150 minutes by Activated Carbon; Adsorbent dose is 6g/L, contact time is 90 minutes by Silica gel is the best adsorbents for removal of the hardness ions from stock solution. Keywords: Environmental pollution, adsorbent, hardness, water and zeolite. INTRODUCTION Water hardness problem is reported to exist in various places around the world 5. Among several known forms of pollution, water pollution is great concern since water is the prime necessity of life and extremely essential for the survival of all living organisms. Various technologies for water pollution control are available; adsorption process is considered better as compared to other methods because of convenience, easy operation and simplicity of design. This process can minimize/remove different type of pollutants and it has a wider applicability in water pollution control 1. Hard water minerals such as calcium, magnesium, iron and manganese result in scaling problems and serious failures in pipelines of boilers and heattransfer equipment. In addition, these divalent ions can react with soap anions decreasing the cleaning efficiency and hence, high consumption of detergents occurred as a result. However, calcium and magnesium are the most common sources of water hardness 4. The main objective of this research was to removal of hardness of water by using as a adsorbent of a new low cost effective product which possess properties similar to Zeolite and it could be used in water processing at industrial scale level. MATERIALS AND METHODS Chemicals and adsorbents: All the chemicals were used in this experiment were purchased from the Qualigens Fine Chemicals, Mumbai by the Department of Chemical Engineering, Andhra University, Visakhapatnam. Preparation of the Adsorbents: Synthetic hard water was prepared by 1g of CaCO 3 dissolved in a litre deionized water to make a water with hardness of 1000 mg/l as CaCO 3 equivalent used as a stock solution. Fly Ash samples were collected from NTPC power plant, Visakhapatnam was washed thoroughly and dried to obtain constant weight. Thus prepared sample is used in preparation of Zeolite by high temperature heat treatment. Experimental Procedure: Fly Ash and Alkali (Na 2 CO 3 ) was used in ratios 5:95, 10:90, 15:85, 20:80, 30:70 and kept in the furnace at 342

temperatures 300 o C, 400 o C, 500 o C, 600 o C, 700 o C for 2 h. Once the activation time was reached, the content was cooled. The Zeolite material was then washed with distilled water until residual Alkali was fully removed. Thus the sample is filtered & dried in an oven at 100 o C for 2hrs and its CEC is determined to check the Zeolite content. The treated Fly Ash is made into pellets by agglomeration with Lime, Sodium Silicate and Sodium Alignate. Testing of LPZ(Laboratory Prepared Zeolite) for CEC(Cation Exchange Capacity): 3g of Zeolite was added in 25 ml of raw water shaken thoroughly for 5 minutes in Flask shaker. The treated Zeolite was filtered and washed several times with DM water. Determination of total hardness Two millilitres of Ammonia buffer solution was added in twenty millilitres of hard water sample (ph 9-10) with EBT indicator appears wine red colour was used in titrate against EDTA. Total hardness was identified by using the following formula: Total hardness = (V 1 *N*50*1000)/(V 2 ) mg/l Here, V 1 - volume of EDTA, V 2 - volume of sample, N - Normality of EDTA and 50 - Equivalent weight of CaCO 3 Optimization of batch experiments: Optimization of adsorbent mass (2-16 g/l), initial ion concentrations (100-1200 mg/l) and contact time (1-240 minutes) experiments were carried out. Optimized adsorption times for Commercial Zeolite, LPZ, Activated Carbon and Silica gel adsorbents were first examined by varying the contact time at room temperature. Removal efficiencies (RE) were identified at various initial ion concentration (100mg/L, 200 mg/l, 300 mg/l, 450 mg/l, 600 mg/l, 800 mg/l, 1000 mg/l, 1200 mg/l) as follows: Removal efficiency (%) = (C i -C e ) / C i *100 The quantity of adsorbed hardness on the adsorbate; i.e. uptake was calculated by the difference of initial and final (or) equilibrium concentrations with the equation q e = (C i -C e )*V/m here C i - initial ion concentration, C e - final ion concentration, q e - quantity of hardness adsorbed on the adsorbate, m - amount of adsorbate and V - volume of the solution RESULTS AND DISCUSSION Effect of contact time on hardness removal: A) Commercial Zeolite: Hardness removal percentage approached equilibrium at 60 minutes (Fig 1). Further increase in contact time does not show significant change in hardness. This might be due to fact that, large number of vacant surface sites is available for the adsorption during the initial stage and with the passage of time. B). LPZ The percentage of hardness removal approached equilibrium within 30 minutes. Further increase in contact time does not show significant change in hardness. This might be due to fact that, large number of vacant surface sites is available for the adsorption during the initial stage and with the passage of time. After some times, repulsive forces between solute molecules on solid phase and liquid phase create difficultness for the solute molecules to occupy remaining vacant surface sites. C). Activated Carbon: The percentage hardness removal approached equilibrium within 150 minutes. Further increase in contact time does not show significant change in hardness. This might be due to fact that, large number of vacant surface sites is available for the adsorption during the initial stage and with the passage of time. After some times, repulsive forces between solute molecules on solid phase and liquid phase create difficultness for the solute molecules to occupy remaining vacant surface sites. D). Silica gel: The percentage hardness removal approached equilibrium within 90 minutes. Further increase in contact time does not show significant change in hardness. This might be due to fact that, large number of vacant surface sites is available for the adsorption during the initial stage and with the passage of time. After some times, repulsive forces between solute molecules on solid phase and liquid phase create difficultness for the solute molecules to occupy remaining vacant surface sites. 4.2. Effect of Adsorbent dose on hardness removal A). Commercial Zeolite: Adsorbent dose was varied between 2-12 g/l and it was indicated that the removal efficiency of hardness improved by increasing the adsorbent dose up to 6 g/l (Fig 5). Further increasing dose, yields were negligible adsorption. Greater availability of exchangeable sites at higher concentration of 343

adsorbent was the reason for the increase in hardness removal with the increase in adsorbent dose. B). LPZ: Adsorbent dose was varied between 2-16 g/l and it was indicated that the removal efficiency of hardness improved by increasing the adsorbent dose up to 12 g/l (Fig 6) Further increase in dose, yields negligible adsorption. Greater availability of exchangeable sites at higher concentration of adsorbent is the reason for the increase in hardness removal with the increase in adsorbent dose. C). Activated Carbon: The effect of the adsorbent dose on hardness removal is shown in Fig 4.7 Adsorbent dose was varied between 2-10 g/l and it was indicated that the removal efficiency of hardness improved by increasing the adsorbent dose up to 4 g/l where further dose increase yields negligible adsorption. Greater availability of exchangeable sites at higher concentration of adsorbent is the reason for the increase in hardness removal with the increase in adsorbent dose. After a certain dose of adsorbent, the maximum adsorption is attained and hence the amount of ions remains constant even with further addition of adsorbent. That s why beyond 4 g/l, the adsorption found to be constant 2. D). Silica gel: The effect of adsorbent dose was varied between 2-12 g/l and it was indicated that the removal efficiency of hardness improved by increasing the adsorbent dose up to 6 g/l where further dose increase yields negligible adsorption. Greater availability of exchangeable sites at higher concentration of adsorbent is the reason for the increase in hardness removal with the increase in adsorbent dose. After a certain dose of adsorbent, the maximum adsorption is attained and hence the amount of ions remains constant even with further addition of adsorbent. That s why beyond 6 g/l, the adsorption found to be constant 2. 4.3. Effect of Initial ion concentration on hardness removal A). Commercial Zeolite: The initial ion concentration was varied between 100-1200 mg/l and it was indicated that the removal efficiency decreases by increasing the initial ion concentration (Fig 9). B). LPZ The initial ion concentration was varied between 100-1200 mg/l and it was indicated that the removal efficiency decreases by increasing the initial ion concentration (Fig 10). C). Activated Carbon: The initial ion concentration was varied between 100-1200 mg/l and it was indicated that the removal efficiency decreases by increasing the initial ion concentration (Fig 11). D). Silica gel: The initial ion concentration was varied between 100-1200 mg/l and it was indicated that the removal efficiency decreases by increasing the initial ion concentration (Fig 12). 4.4. Comparison of four adsorbents by their equilibrium time and dose: The contact time observed from 1-240 minutes, dosages are observed from 2-16 g/l (Fig 13). 4.5. The minimum percentages of removal efficiencies of four adsorbents: The adsorbents are treated for contact time, dosage, initial ion concentration, the minimum removal efficiency (RE) percentages (Fig 14). 4.6. The maximum percentages of removal efficiencies of four adsorbents: 4.7. Isotherm study: Langmuir isotherm: `The linear form of Langmuir isotherm C e /q e =1/(q m *K L )+C e /q m (1) here, q e - the ion concentration on adsorbent at equilibrium (mg/g), q m - (mg/g) and K L (g/l) - Langmuir constants related to the maximum adsorption capacity and adsorption energy (equilibrium adsorption constant). q e is calculated by: q e = (C i -C e )*V/m (2) C i - ion concentration (mg/l), C e - equilibrium (or) final ion concentration (mg/l), Q e - quantity of hardness adsorbed on the adsorbate (mg/g), m - amount of adsorbate (g) and V - volume of the solution (L). The dimensionless constant separation factor R L can be used to define essential features of Langmuir isotherm model. R L is expressed by the following equation: R L = 1/ (1+K L *C i ) (3) here, C i - initial hardness (mg/l) and K L - Langmuir constant (g/l). The separation factor R L indicates the isotherm s shape and the nature of the adsorption process, that is, unfavorable (R L >1), linear (R L =1), favorable (0< R L < 1) and irreversible (R L =0). If the condition is 344

favourable, it indicating that the adsorption process is favourable for the removal of hardness ions 3. Isotherm kineticss: 4.7.1. Langmuir adsorption isotherm: A). Commercial Zeolite: The values of R L was found to be 0.0010, indicating that the adsorption process is favourable for the removal of hardness ions. The observed values of R 2, q m and K L from the following plot that are 0.966, 250 and 0.957 respectively. The values are satisfactory for the adsorption on to Commercial Zeolite (Table 2). B). LPZ: The values of R L was found to be 0.0014, indicating that the adsorption process is favourable for the removal of hardness ions. The observed values of R 2, q m and K L from the following plot that are 0.984, 200 and 0.711 respectively. C). Activated Carbon: The values of R L was found to be 0.0005, indicating that the adsorption process is favourable for the removal of hardness ions. The observed values of R 2, q m and K L from the following plot that are 0.984, 333 and 1.608 respectively. D). Silica gel: The values of R L was found to be 0.0007, indicating that the adsorption process is favourable for the removal of hardness ions. The observed values of R 2, q m and K L from the following plot that are 0.988, 333 and 1.188 respectively. Freundlich isotherm: Freundlich isotherm (Freundlich, 1932) is another isotherm model; it considers adsorption on heterogeneous surfaces. The linear form of Freundlich model can be written as: log q e = log K f + (1/n)log C f (3) Here q e is calculated by using the formula given below: q e = (C i -C e )*V/m (4) In the above equations: C i - initial ion concentration (mg/l), C e - equilibrium (or) final ion concentration (mg/l), Q e - quantity of hardness adsorbed on the adsorbate (mg/g), m - amount of adsorbate (g), V - volume of the solution (L). Isotherm kinetics: 4.7.2. Freundlich adsorption isotherm: A).Commercial Zeolite: The observed values of R 2, n and K f from the following plot that are 0.926, 1.669 and 0.612 respectively (Table 3). B). LPZ: The observed values of R 2, n and K f from the following plot that are 0.912, 2.141 and 0.891 respectively. C). Activated Carbon: The observed values of R 2, n and K f from the following plot that are 0.993, 1.46 and 0.342 respectively. D). Silica gel: The observed values of R 2, n and K f from the following plot that are 0.970, 1.567 and 0.505 respectively. CONCLUSION 1. The affinity of the four adsorbents for removing the hardness was in the order of 100> 200> 300> 450> 600> 800> 1000> 1200 mg/l, the order was as a result of a combination of different factors, but maximum removal efficiencies of four adsorbents obtained at initial ion concentration 100mg/L. 2. The key factors found to control the adsorption efficiency of the adsorbents were: adsorbent contact time, adsorbent dose, initial ion concentration. 3. The following conditions were found to be the best for the removal of the hardness ions from stock solution by the four adsorbents: Adsorbent dose is 6g/L, contact time is 60 minutes by LPZ, Adsorbent dose is 12g/L, contact time is 30 minutes by Commercial Zeolite, Adsorbent dose is 4g/L, contact time is 150 minutes by Activated Carbon, Adsorbent dose is 6g/L, contact time is 90 minutes by Silica gel. 4. LPZ has a low maximum adsorption capacity (200 mg/g) compared with commercial adsorbents. LPZ is essential to improvise the capacity for more washes, hence save economy and time. In order to reduce the cost of the adsorbent, use the natural substances having similar properties as chemicals instead of chemicals used in the preparation in the present study. 345

Fig 1 Effect of contact time on hardness removal by Commercial Zeolite Fig 2 Effect of contact time on hardness removal by Commercial LPZ Fig 3 Effect of contact time on hardness removal by Activated Carbon 346

Fig 4 Effect of contact time on hardness removal by Activated Carbon Fig 5 Effect of contact time on hardness removal by Commercial Zeolite Fig 6 Effect of contact time on hardness removal by LPZ 347

Fig 4.7 Effect of contact time on hardness removal by LPZ : (Hardness 510mg/L, Contact time (150 min). Fig 8 Effect of contact time on hardness removal by Silica gel: (Hardness 510mg/L, Contact time(90 min). Fig 9 Effect of initial ion concentration on hardness removal by Commercial Zeolite: (Contact time 60 min, Dosage 6g/L). 348

Fig 10 Effect of initial ion concentrationn on hardness removal by LPZ: (Contact time 30 min, Dosage 12g/L). Fig 11 Effect of initial ion concentration on hardness removal by activated carbon: (Contact time 150 min, Dosage 4g/L). Fig 12 Effect of initial ion concentration on hardness removal by Silica gel: (Contact time 90 min, Dosage 6g/L). 349

Comparison of Fig 13. four adsorbents by their equilibrium time and dose Fig 14 minimum percentages of removal efficiencies of four adsorbents Fig 15 maximum percentages of removal efficiencies of four adsorbents when treated for Contact time, Dosage, Initial ion concentration. 350

Fig 16 Langmuir adsorption isotherm for Commercial Zeolite Fig 17 Langmuir adsorption isotherm for LPZ. Fig 18 Langmuir adsorption isotherm for Activated Carbon. 351

Fig 19 Langmuir adsorption isotherm for Silica gel. Fig 20 Freundlich adsorption isotherm for Commercial Zeolite. Fig 21 Freundlich adsorption isotherm for LPZ. 352

Fig 22 Freundlich adsorption isotherm for Activated carbon. Fig 23 Freundlich adsorption isotherm for Silica gel. Table 1 Chemical Composition of Fly Ash Compound Composition of Fly Ash (%) SiO 2 59.96 Al 2O 3 26.15 Fe 2O 3 5.85 S.No Table 2 Langmuir adsorption parameters of four adsorbents: Parameter 1 R 2 Commercial Zeolite LPZ Adsorbent Activated Carbon Silica gel 0.966 0.984 0.984 0.988 2 q m 250 200 333 333 3 K L 0.957 0.711 1.608 1.188 353

Table 3 Freundlich adsorption of four adsorbents: S.No Parameter Adsorbent Commercial Zeolite LPZ Activated Carbon Silica gel 1 R 2 0.926 0.912 0.993 0.970 2 N 1.669 2.141 1.460 1.567 3 K f 0.612 0.891 1.342 1.505 REFERENCES 1. Bhatnagar A and Minocha AK. Conventional and non conventional adsorbents for removal of pollutants from water a review. Indian J. of chem.. tech. 2006;13(5) 203-217. 2. Chakrabarty S and Sharma HP. Defluoridation of contaminated drinking water using neem charcoal adsorbent: Kinetics and equilibrium studies. Intr. J. of ChemTech Research. 2012; 4(2): 511-516. 3. Hameed BH, Mahmoud DK. and Ahmad AL. Equilibrium modeling and kinetic studies on the adsorption of basic dye by a low-cost adsorbent: Coconut (Cocos nucifera) bunch waste. J. of Hazardous Materials. 2008;158(1): 65-72. 4. Park JS, Song JH, Yeon KH. and Moon S H. 2007. Removal of hardness ions from tap water using electromembrane processes. Desalination. 2007; 202: 1-8. 5. Rolence C, Revocatus LM and Karoli NN. Water hardness removal by coconut shell activated carbon. Intr. J. of science, technology and society.2014; 2(5): 97-102. 354