[ ] Sensors for Temperature Measurement, and Their Application 2L R 1 1 T 1 T 2

Similar documents
ATS WHITE PAPER. Air Flow Measurement in Electronic Systems

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Thermal Resistance Measurement

Section 7. Temperature Measurement

MIL-STD-883E METHOD THERMAL CHARACTERISTICS

Temperature Measurement

I. MEASUREMENT OF TEMPERATURE

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

SENSORS AND TRANSDUCERS

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Thermal Characterization of Packaged RFIC, Modeled vs. Measured Junction to Ambient Thermal Resistance

MEASURING INSTRUMENTS

Lednium Series Optimal X OVTL09LG3x Series

Understanding Hot-Wire Anemometry

Lednium Series Optimal X (10-watts,120 Viewing Angle)

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

Memory Thermal Management 101

SENSORS and TRANSDUCERS

Reflow Soldering Processes Development Using Infrared Thermography

PLW7070* Series and PLW3535* Series I2LED High Power LED Product Application Note

University of Connecticut Department of Electrical and Computer Engineering. ECE 4901: Fall 2017 Spring 2018

THERMOCOUPLE CHARACTERISTICS TRAINER

Part 2. Sensor and Transducer Instrument Selection Criteria (3 Hour)

ECNG3032 Control and Instrumentation I

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

Sensing, Computing, Actuating

Temperature Measurement

T h e rm i s t o r s

Boundary Condition Dependency

1 THE CONCEPT OF TEMPERATURE

3. LED THERMAL. a) b) 3.1. Introduction Heat transfer introduction LED ACADEMY/LED THERMAL

I m. R s. Digital. R x. OhmmetersxSeries Shunt Digital. R m

BETTER DESIGN AND NEW TECHNOLOGIES IMPROVE LASER POWER MEASUREMENT INSTRUMENTATION

Measurement in Engineering

Sensors and transducers

Temperature Measurement

Measurements & Instrumentation. Module 3: Temperature Sensors

Temperature Sensors & Measurement

Temperature Measurements

Control Engineering BDA30703

Transient Thermal Measurement and Behavior of Integrated Circuits

Peltier Application Note

Fig. 1. Schema of a chip and a LED

ME 105 Mechanical Engineering Laboratory Spring Quarter Experiment #2: Temperature Measurements and Transient Conduction and Convection

Chapter 6. Fiber Optic Thermometer. Ho Suk Ryou

Making Contact with Temperature

Sensors and Actuators Sensors Physics

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

A Guide to Board Layout for Best Thermal Resistance for Exposed Packages

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

Veerapong Kanchanawongkul*

c. VH: Heating voltage between the collector and emitter.

Reliability Analysis of Moog Ultrasonic Air Bubble Detectors

PHYS 352 Assignment #1 Solutions

Thermometry. History. History 1/21/18. The art or science of temperature observation

Thermal measurement a requirement for monolithic microwave integrated circuit design

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

Thermal Management of SMT LED Application Note

1) Thermo couple sensor

5W HI-POWER LED SPECIFICATION

(PT-A6) Visible Light Detector for Security Lighting

IC Temperature Sensor Provides Thermocouple Cold-Junction Compensation

FYS4260/FYS9260: Microsystems and Electronics Packaging and Interconnect. Thermal Management

Tools for Thermal Analysis: Thermal Test Chips Thomas Tarter Package Science Services LLC

(PT-A6) Visible Light Detector for Security Lighting

Specification LY530. Drawn Approval Approval. Rev. 08 December 서식번호 : SSC-QP (Rev.00)

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

Review of Semiconductor Physics. Lecture 3 4 Dr. Tayab Din Memon

YJ-BC-270H-G01 High CRI LED

True temperature measurement of electronics through infrared transparent materials

MODEL NAME : LLDMWW0-15K*0*A

P8D1 P8D1. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications.

Dr. Michael Müller. Thermal Management for LED applications

Specification LR530 SSC CUSTOMER. Rev. 07 January acriche.com. Document No. : SSC-QP (Rev.00)

P8D137. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications. Super high Flux output

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Critical parameters of

QED222, QED223 Plastic Infrared Light Emitting Diode

Temperature Measurement

RoHS. Specification CUD8DF1A. Drawn Approval Approval. 서식 Rev: 00

Specification LW514. [Preliminary] CUSTOMER SSC. Rev. 00 October Document No. : SSC-QP (Rev.00)

Specification LW514. Drawn Approval Approval. Rev. 02 December 서식번호 : SSC-QP (Rev.00)

Good practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors

VALLIAMMAI ENGINEERING COLLEGE

Chapter 6 Temperature Measurement (Revision 2.0, 1/12/2009)

Novel Flux Calibration Source. CORM 2007 David C. Gross May 10, 2007

Specification LR530. Drawn Approval Approval. Rev. 08 December Document No. : SSC-QP (Rev.00)

RoHS. Specification CUD8AF1C. 서식 Rev: 00

S150PTD-1A. Technical Data Sheet. 3.2x1.6mm, Phototransistor LED Surface Mount Chip LED. Features: Descriptions: Applications:

Thermal Management In Microelectronic Circuits

TECHNICAL INFORMATION

LM135/LM235/LM335, LM135A/LM235A/LM335A Precision Temperature Sensors

ME 365 EXPERIMENT 5 FIRST ORDER SYSTEM IDENTIFICATION APPLIED TO TEMPERATURE MEASUREMENT SYSTEMS

Component & Board Level Cooling.

Process Control & Design

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

INSTRUMENTATION ECE Fourth Semester. Presented By:- Sumit Grover Lect., Deptt. of ECE

Specification LR521. Drawn Approval Approval. Rev. 05 December 서식번호 : SSC-QP (Rev.00)

A Determination of Planck s Constant with LED s written by Mark Langella

Device 3D. 3D Device Simulator. Nano Scale Devices. Fin FET

Transcription:

Sensors for Temperature Measurement, and Their Application In today s market, it is very rare to see electronic equipment that has not undergone extensive thermal evaluation, either by measurement or simulation. Inevitably, the temperature of the device junction or case, or the enclosure, has been measured to ensure that the system will operate to its intended specifications. A quick look at the equations associated with stress in a lead wire, and with the acceleration factor used in reliability calculations, will show why temperature plays such an important role in electronics equipment [1]. ledt pr s= ( ) 2L R e A 0.5 (1) Equations 1 and 2 clearly demonstrate the linear and exponential relationships that temperature has in the operation of the electronic components. Concurrently, simulation tools are used extensively in today s thermal design. But, due to the complexity of the electronics packaging and composite nature of the materials used, the simulation data must be verified in order to ensure reliable data is obtained. In this article, we present different sensors and their application domains in electronics thermal management. Table 1 shows six primary sensors used in temperature measurement: E = Modulus of elasticity L e = Wire-bond characteristic length R A = Aspect ratio of the deformed section R = Non-deformed wire radius T = Temperature σ = Stress at the wire-bond attachment λ = Stress concentration And the acceleration factor, AT [ ] E a 1 1 = e k B T 1 T 2 (2) A T = Temperature acceleration factor E a = Activation energy k B = Boltzman constant T = Temperature (K) Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 10

Transducer or Probe Resistor Temperature Sensitive Parameter Contact Method Remarks Electrical resistance or voltage at constant current Direct contact Usually calibrated against a thermocouple Thermocouple Open circuit voltage Direct contact Useful as a "point" sensor Diode or Transistor Voltage, usually with constant forward bias current Direct contact Usually employed to measure an active device or IC temperature Figure 1. Surface-Mounted RTD (Courtesy of RDF Corporation) Infrared or Radiation Detector voltage Line-of-site or optical contact Yields a temperature map or image. Not strictly quantitative unless sample emittance is known at all image points Fluorescent Detector Detector voltage Direct contact (proximity) Approximate point detector; contact resistance a problem Liquid Crystal Color Direct contact Yields a temperature map; semi-quantitative unless a detailed calibration is performed to quantify color vs. temperature relation Table 1. Standard Temperature Tranducers [2]. 1 Resistance Thermometer With these sensors, the resistance of the sensing element changes with temperature. The sensors come in two primary forms: thermistors (lightly doped semiconductors) and metal resistors. Equations 3 and 4 represent the relationships between resistance and temperature for these two sensors, respectively: R (T) = R o (T o ) EXP[ C 1 /K B (1/T - 1/T o )] (3) R (T) = R 0 [l + C 1 (T-T 0 ) + C 2 (T-T 0 ) 2 +...] (4) C 1 and C 2 = Constants K B = R 0 = Boltzman constant Resistance at reference temperature R(T) = Resistance at temperature T T 0 = Reference temperature in K Figure 1 shows a surface-mounted RTD (resistance temperature detector) that can be installed onto a surface for temperature measurement. The following must be considered when using these types of sensors: 1. The sensor (resistor) must be in intimate contact with the test specimen solder or careful epoxy, is recommended. 2. The sensor must be placed in an isothermal region constant temperature over the sensor. 3. The resistor power dissipation (if in voltage mode) must be minimized to not impact the problem. 4. This sensor is suitable for part-level measurement as it can be embedded directly on the die. 2 Thermocouples (TC) These sensors are far and away the most commonly used devices in the field. Wide flexibility and broad availability enable their use for a variety of temperature measurements. TCs work on the principle that bringing together two wires of different elements or alloys produces a voltage as a result of temperature, Seebeck effect. Equation 5 provides the governing principle for TCs: Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 11

T V ê ú TC To T ò ë αa T αb T û dt ( ) = é ( )- ( ) ù To V TC = Voltage produced by the thermocouple α A,B = Seebeck coefficient for wires A & B (5) Of the TC types shown above, E, J, K and T are the most commonly used. Many thermocouple meters on the market can use all of these sensors interchangeably. That s because the voltage output of these TCs is in the same range; hence, the internal electronics can be designed to accommodate each of them. T = Temperature Table 2 shows some of the typical TC types that are used in the electronics thermal measurement. There are some unique features about each sensor type that one needs to know. For example: E-type Though accurate, has a limited range. J-type Should not be used in a humid environment, since the iron component of the TC will oxidize, resulting in erroneous output. Table 2. Thermocouple Types and Their Respective Voltage Outputs [2]. K-type Though widely used, the voltage output can be negatively impacted if the wire kinks. T-type Can be an effective heat transfer medium, because of its copper component, either as a fin or a conductor. Type Material A Material B V Output (µv) B Platinum -30% E Nickel-chromium alloy Platinum -6% A copper-nickel alloy J Iron A different coppernickel alloy K Nickel-aluminum alloy (Alumel) Nickel-chromium alloy (Alumel) Norm. error lim.+/- 1 0 62 1.7 Remarks Not useful below 50 C; best for very high temperature measurements Well-suited for low temperature measurements 51 2.2 Iron P leg subject to variations in Seebeck coefficients from impurities 40 2.2 Very popular for electronics cooling experiments R Platinum -13% S Platinum -10% Platinum 7 5 Very stable Platinum 7 5 T Copper Copper-nickel alloy 40 1 Copper leg could create a conduction path (fin) in surface temperature measurements Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 12

It is also important to note that thermocouples measure temperature at the point where the two wires are connected. The smaller the junction, the more precise the temperature that is read. A large TC junction will result in the temperature being averaged over its entire area. Multiple junctions, as shown in Figure 2, will have the same impact. In Figure 2, the multi-junction created as a result of twisting the wires prior to spot-welding the ends (the TC on the right), creates a significantly larger junction. Whether measuring surface or fluid temperatures, the number reported by this TC will be an average temperature over a 2-3mm junction length. Let us consider a J-type thermocouple formed of Iron and Constantan. All four wires are spot-welded together to form the TC junction. The temperature can be read across any of the Iron and Constantan combinations, and the electronic noise can be read across either the two Irons or the two Constantans. Because two similar metals cannot create the Seebeck effect (convert thermal differentials to electric voltage), whatever signal is measured on these wires is the electronic noise in the measurement domain. Thermocouple errors can be attributed to the following areas: Poor junction connection Galvanic action Thermal shunting Electrical noise Installation problem due to tester TC measuring Junction Figure 3. Four-wire Thermocouple System for Measurement of Electronic Noise and Temperature. Measuring surface temperature is always a challenging process. The following steps will help to increase the accuracy of such measurements: Keep installation size as small as possible. To reduce conduction errors, bring thermocouple wires away from the junction, along an isotherm for at least 20 wire diameters. Locate the measuring junction as close to the surface as possible. Figure 2. Single and Multi-junction Thermocouple Sensors [3]. Of the errors listed above, electrical noise is uniquely problematic, especially in today s high frequency equipment. A TC can be used in a 4-wire format to resolve the electronic noise that may affect the reported temperature. Using a 4-wire thermocouple, as shown in Figure 3, we can measure temperature and electrical noise. To avoid changes in convective or radiative heat transfer, design the installation so that it causes minimum disturbance to any fluid flow or the least possible change in the emissivity of the surface. Reduce the thermal resistance between the measuring junction and the surface to as low a value as possible. Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 13

3 Diode or Transistor Diodes and transistors are parts whose electrical properties are a function of temperature. Diodes are broadly used for temperature measurement, either as embedded sensors in functional devices or as a thermal test chips. Figure 4 shows one such thermal test chip for device-level simulation. calibration converts them into temperature. The following are required for IR-based measurements: Infrared imaging system -- The market offers a broad range, but a worthy system starts at around $30-70k. For IR microscopy (down to 5mm only- lower limit of IR wave-length), the system starts at $180k. Signal processing equipment. Knowledge of emissivity if the test specimen must be coated with a known emissivity material. Calibration. Figures 5a and 5b show a typical IR image of heatemitting surfaces. Figure 4. Thermal Test Chip [3]. The following depicts the general considerations for usage of semiconductor materials for temperature measurement: Every semiconductor device has at least one electrical parameter that is a function of temperature. Thermal test chips use the thermally sensitive parameter of semiconductor devices to measure chip junction temperature. Separate heating and sensing elements are usually used to avoid the need for electrical switching. Thermal calibration of the sensing device is necessary. Thermal test chips provide an effective means of measuring chip junction temperature in an actual package configuration. Use of materials is subject to availability/suitability for the intended package application. 4 Infrared Thermography Infrared thermography works on the basis of the IR waves emitted from a heated surface. The infrared system captures the waves, and based on internal Figures 5a And 5b. IR Images of a Circuit Board in Forced (a) and Natural (b) Convection [3]. The following points are noteworthy when using an IR camera for temperature measurement: Application accuracy is a function of emissivity. The measurement situation must duplicate the actual environment, as far as air velocity, temperature and air flow distribution are concerned. The IR camera is sensitive to reflected radiation. Carbon dioxide and water vapor absorb significant energy and may cause significant error. In an electronics application, surfaces typically have different emissivities.thus, one must make the emissivity uniform before measurement. In most IR equipment, the temperature readout is the average over an area. Therefore, temperature peaks Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 14

may be ignored as the result of integration. To remedy the situation, better IR optics must be used to reduce the area where integration occurs. 5 Optical Probes Optical sensors are light-emitting devices that illuminate the test body with source radiation, and can detect reflected radiation, or simulated radiation such as fluorescence. Although not broadly used, optical probes are used at the die or component level. Figure 6 shows one such a probe. OPTICAL FIBER CORE JACKET CLADDING CLEAR ELASTOMER VERY THIN LAYER OF PHOSPHOR IN ELASTOMER OPEN ENDED OPTICAL FIBERS PHOSPHOR COATED ONTO SURFACE Figure 6. Optical Probe For Surface Temperature Measurement The Probe Either Touches The Surface Or Captures The Reflected Light From A Fluorescent Treated Surface. 6 Liquid Crystal Thermography LC thermography works on the basis of visible light reflected from a surface treated with the LC material. The system captures the reflected wavelengths, and based on internal calibration, converts them into temperatures. Liquid crystals (LCs) are cholesteric materials. When applied to a heated surface they realign and reflect light at a different wavelength. The reflected light shows the standard colors seen in a rainbow. Figure 7 shows the application of LCs on an IC. LENS PHOSPHOR LAYER COMPRESSED AGAINST SURFACE FOR GOOD THERMAL CONTACT LOW THERMAL CONDUCTIVITY ELASTOMER PROVIDES THERMAL ISOLATION OF SENSOR Blue: the hottest point on the IDC die Black: out of the range of the applied LC Figure 7. Color Display of Liquid Crystal Applied on an IC. Blue Reveals the Circuit s Hottest Point, and Black Shows That the Temperature is Outside the Range of the Crystal Material [3]. The following are salient features of LC material: Liquid crystals are organic compounds that can be poured like a liquid, yet reflect light like a crystal. Changes in LC optical properties can be produced by externally applied fields (e.g., electrical, magnetic, and thermal). Cholesteric liquid crystals progressively exhibit all colors of the visible spectrum when heated over their event temperature range. Width and placement of the event temperature range can be controlled by selecting and mixing the appropriate liquid crystals. Liquid crystals are commercially available with event temperatures ranging from below 0 o C to 160 o C, with spans ranging from 1 to 50 o C. An LC thermography system such as the one shown in Figure 8 can provide a very effective temperaturemapping system. Figure 8. The Thermview System for Macro and Microscopic (Down to 1µm) Surface Temperature Measurement [4]. Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 15

Figure 9 shows a typical result of LC thermography at die level. References: 1. Klinger, D., Nakada, Y., Menendez, M., AT&T Reliability Manual, Van Nostrand Reinhold, 1990. 2. Azar, K., Thermal Measurement in Electronics Cooling, CRC Press, 1997. 3. Advanced Thermal Solutions, Inc., Tutorial Series, Principles of Temperature Measurement. 4. thermview System, product of Advanced Thermal Solutions, Inc. 5. White, F., Viscous Fluid Flow, McGraw-Hill, 3rd Ed., 2005. My name is Francisco. Figure 9. Temperature Distribution Across a Memory Chip (5 x 5 mm) at T ambient = 25 o C, as Shown Using Liquid Crystal Thermography [3]. Like any other system for temperature measurement, LC thermography offers distinct advantages and disadvantages. One salient advantage of LC thermography is that it s not dependent on surface emissivity. A second is that at micron and submicron levels, though not a trivial task, LC thermography allows easier and less costly temperature measurements while enabling 1µm or smaller spatial resolution. One disadvantage of LC thermography is that it is not a pick-up-and-measure system like IR. One must apply the calibrated liquid crystal material to a surface in order to perform the measurement. But, this is similar to the IR system, in that you need to make the surface emissivity uniform if the measured surface has multi-emissivity (e.g., a die or PCB). In this article, we reviewed six different probes/techniques for temperature measurement. It would be a missed opportunity not to include a word on calibration. Irrespective of the types of measurement and sensors one uses, calibration is of utmost importance. Pay special attention to the calibration process and ensure that the sensors are properly calibrated. Further, one needs to ensure that the chosen sensor is suitable for the type of measurement. As Prof. Frank White states in his Viscous Flow book, Bad data is worse than no data at all [5]. I design GPS devices for the defense industry. Yesterday, it took me a half-hour to find my car at the mall. I AM HOT (AND I M NOT AFRAID TO ADMIT IT) They say the first step to solving your problems is admitting you have one. The second is calling us. Now that ADVANCED THERMAL SOLUTIONS, INC. has teamed up with DIGI-KEY, your electronics cooling solutions are only a click away. Visit www.digikey.com to place an order or www.qats.com for further technical information. Published By Advanced Thermal Solutions, inc. 89-27 Access Road Norwood, MA 02062 T: 781.769.2800 www.qats.com Page 16