Fundamentals of Low Intensity Shock Calibration

Similar documents
Primary Calibration of Shock Transducers Influence of the Laser Spot Position

ISO INTERNATIONAL STANDARD

INVESTIGATION OF IMPACT HAMMER CALIBRATIONS

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

PROGRESS IN DEVELOPMENT OF CALIBRATION SYSTEMS FOR ANGULAR VIBRATION PICKUPS

MODEL-BASED ANALYSIS OF THE DYNAMIC BEHAVIOUR OF A 250 KN SHOCK FORCE CALIBRATION DEVICE

DEVELOPMENT OF ANGULAR VELOCITY CALIBRATION FACILITY USING SELF-CALIBRATABLE ROTARY ENCODER

INSTRUMENTAL ENGINEERING

Mechanical Shock Testing for LIGA Materials Characterization

DROP-WEIGHT SYSTEM FOR DYNAMIC PRESSURE CALIBRATION

Analysis of shock force measurements for the model based dynamic calibration

Improving Safety Provisions of Structural Design of Containment Against External Explosion

Robust and Miniaturized Interferometric Distance Sensor for In-Situ Turning Process Monitoring

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Study of Rupture Directivity in a Foam Rubber Physical Model

Standard Small Angle Generator Using Laser Interferometer

Precision Material Tester Using the Levitation Mass Method

DEVELOPMENT OF MEASUREMENT STANDARD FOR DYNAMIC PRESSURE AT MIKES

Chapter 7 Vibration Measurement and Applications

Modelling of a dynamic torque calibration device and determination of model parameters

Overview. Sensors? Commonly Detectable Phenomenon Physical Principles How Sensors Work? Need for Sensors Choosing a Sensor Examples

Characterization of Force Transducers for Dynamic Measurements

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Design and analysis of a pneumatic test system for shock response spectrum

Survey Meter OD-01 Address: Phone: Fax: URL:

Sensing and Sensors: Fundamental Concepts

4 A mass-spring oscillating system undergoes SHM with a period T. What is the period of the system if the amplitude is doubled?

Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design

Machine Positioning Uncertainty with Laser Interferometer Feedback

EE 242 EXPERIMENT 8: CHARACTERISTIC OF PARALLEL RLC CIRCUIT BY USING PULSE EXCITATION 1

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

ANNEXE 8. Technical protocols for the interlaboratory comparisons

Investigating the Change in Acceleration of a Trolley Running Down an Inclined Plane

Classification of services in Acoustics, Ultrasound and Vibration

2d-Laser Cantilever Anemometer

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

Chapter (5) Matter Waves

Simple Harmonic Motion Practice Problems PSI AP Physics 1

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Theory and Design for Mechanical Measurements

Characterizing, Simulating, and Eliminating Vibration Induced Counts in Measurement While Drilling Gamma Ray Detectors. authors

The activities of micro-force measurement below 10 mn in Center for Measurement Standards

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 29. Shock Response Spectrum Synthesis via Wavelets

NUMERICAL AND EXPERIMENTAL STUDY OF FAILURE IN STEEL BEAMS UNDER IMPACT CONDITIONS

Supporting Online Material for

Experimentation. Third Edition. Wheeler. Ahmad R. Ganji. School of Engineering. With Third Edition contributions by. V. V. Krishnan. Brian S.

Acceleration levels of dropped objects. Technical paper 321

Curriculum Map-- Kings School District Honors Physics

Super High AUTO (SHA) Series

Solid State Physics (condensed matter): FERROELECTRICS

Vibration Control Effects of Tuned Cradle Damped Mass Damper

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Non-Destructive Testing of Concrete Based on Analysis of Velocity Dispersion of Laser Ultrasonics

Digital Holographic Measurement of Nanometric Optical Excitation on Soft Matter by Optical Pressure and Photothermal Interactions


Overview. Sensors? Commonly Detectable Phenomenon Physical Principles How Sensors Work? Need for Sensors Choosing a Sensor Examples

Module 2 Mechanics of Machining. Version 2 ME IIT, Kharagpur

4. EXPERIMENTS AND RESULTS

Coupled Electrical Oscillators Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 5/24/2018

Measurement Techniques for Engineers. Motion and Vibration Measurement

A Simple Approximate Method for Predicting Impact Force History and Application to Pyroshock Simulation

High-Sensitivity Gamma-Ray Imaging With Double Sided Strip Detectors

DESIGN AND FABRICATION OF THE MICRO- ACCELEROMETER USING PIEZOELECTRIC THIN FILMS

INSTRUMENTATION OF ULTRASONIC HIGH-FREQUENCY MACHINE

COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M

4.1 KINEMATICS OF SIMPLE HARMONIC MOTION 4.2 ENERGY CHANGES DURING SIMPLE HARMONIC MOTION 4.3 FORCED OSCILLATIONS AND RESONANCE Notes

Raymond A. Serway Chris Vuille. Chapter Thirteen. Vibrations and Waves

ERROR SOURCE IDENTIFICATION AND STABILITY TEST OF A PRECISION CAPACITANCE MEASUREMENT SYSTEM

W 18e Heat Capacity Ratio γ

Simple Harmonic Motion Investigating a Mass Oscillating on a Spring

Dynamic characterization of engine mount at different orientation using sine swept frequency test

Investigations for the model based dynamic calibration of force transducers by using shock excitation

Pre-failure Deformability of Geomaterials. Hsin-yu Shan Dept. of Civil Engineering National Chiao Tung University

Lab 3: The Coupled Pendulum and a bit on the Chaotic Double Pendulum

Effective Measurement Method of Thermal Deformation of Machine Tools Caused by Linear Axis Motion

Chapter 13, Vibrations and Waves. 1. A large spring requires a force of 150 N to compress it only m. What is the spring constant of the spring?

The Mössbauer Effect

Conservation of Angular Momentum

VALLIAMMAI ENGINEERING COLLEGE

UN Test Report - EQ40(Min.14Wh, 3.8V)-

Display counter electromechanical

PHYSICS 359E: EXPERIMENT 2.2 THE MOSSBAUER EFFECT: RESONANT ABSORPTION OF (-RAYS

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

RAMS seminar. Vibration by Viggo Pedersen

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

2007 Problem Topic Comment 1 Kinematics Position-time equation Kinematics 7 2 Kinematics Velocity-time graph Dynamics 6 3 Kinematics Average velocity

DY AMIC CHARACTERISTICS MEASUREME TS OF A FORCE TRA SDUCER AGAI ST SMALL A D SHORT-DURATIO IMPACT FORCES

Basic Principle of Strain Gauge Accelerometer. Description of Strain Gauge Accelerometer

The secondary winding have equal no. of turns. The secondary windings are placed identically on either side of the primary winding.

Product Data Sheet PD-0053-A

Lecture #2: Split Hopkinson Bar Systems

Prof. S.K. Saha. Sensors 1. Lecture 5 June 11, Prof. S.K. Saha. Purpose Classification Internal Sensors. External Sensors.

FIGURE P13.5 FIGURE P13.6. Chapter 13 Problems

DYNAMICS AND DAMAGE ASSESSMENT IN IMPACTED CROSS-PLY CFRP PLATE UTILIZING THE WAVEFORM SIMULATION OF LAMB WAVE ACOUSTIC EMISSION

Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory

New Plasma Diagnosis by Coherence Length Spectroscopy

Vibration modelling of machine tool structures

Curriculum Map-- Kings School District- Physics

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION

Transcription:

Low intensity shock metrology for safety related applications Fundamentals of Low Intensity Shock Calibration Speaker : Yu-Chung Huang Date : 2014.08.20 Center for Measurement Standards/ Industrial Technology Research Institute Bldg. 16, 321 Kuang Fu Rd, Sec. 2 Hsinchu, Taiwan 1

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 2

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 3

Shock for Industry Application Car colliding human 600 m/s 2 chest safety : Automobile collision Shock testing machine Electric equipment shock test 4

Example : Lens Shock Test TEST SPECIFICATION: Wave Form :Half sine wave Acceleration :50 g Duration Time :20 ms No. of Shock :Each axis 3 times Shock Direction :X,Y,Z axis X axis Y axis Z axis 5

Example : Vehicle Video Recorder TEST SPECIFICATION: Wave Form :Half sine wave Acceleration :50 g Duration Time :26 ms No. of Shock :Each axis 5 times Shock Direction :Y axis 6

Example : LCD Monitor TEST SPECIFICATION: (operation ) Wave Form :Half sine wave Acceleration :50 g Velocity Change :11 ms No. of Shock :Each axis 3 times Shock Direction :±X, ±Y, ±Z axis 7

Example : Battery SHOCK TEST SPECIFICATION: Wave Form :Half sine wave Acceleration :5,000 g Duration :0.3 ms Test Axis :±X, ±Y, ±Z axis No. of Shock :Each axis 3 times Total Test Time :18 times 8

Example : Car Monitor TEST SPECIFICATION: Wave Form :Square wave Acceleration :65 g Velocity Change :4.78 m/sec No. of Shock :Each axis 1 time Shock Direction :±X, ±Y, ±Z axis 9

Example : Speaker Box TEST SPECIFICATION: Wave Form :Square wave Acceleration :40 g Duration Time :8.2 ms Test Axis :±X, ±Y, ±Z axis No. of Shock :Each axis 3 times 10

Example : PC Panel TEST SPECIFICATION: (1) Wave Form :Sawtooth wave (Operating) Acceleration :40 g Duration Time :11 ms No. of Shock :Each axis 3 times Shock Direction :±X, ±Y, ±Z axis (2) Wave Form :Sawtooth wave (Non-Operating) Acceleration :75 g Duration Time :11 ms No. of Shock :Each axis 3 times Shock Direction :±X, ±Y, ±Z axis 11

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 12

ISO Standard for Calibration of Vibration and Shock Transducers Methods for the calibration of vibration and shock transducers ISO 16063-1 Basic Concepts Primary Method Comparison Method Environment Calibration Other Method ISO 16063-11 Primary vibration ISO 16063-12 Reciprocity method ISO 16063-13 Primary shock ISO 16063-15 Primary angular vibration ISO 16063-21 Comparison vibration ISO 16063-22 Comparison shock ISO 16063-23 Comparison angular vibration ISO 16063-31 Transverse vibration sensitivity ISO 16063-32 Resonance test ISO 16063-41 Calibration of laser vibrometers ISO 16063-42 Calibration of seismometer 13

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 14

ISO 16063-22 Shock calibration by comparison to a reference transducer 2005(E) 15

Study for ISO Standard 16063-22 Shock Signal Generation by Hammer-Anvil Motion events by two elastic solid bodies bumping. Different velocity V 1 -V 2 Spring represents the elasticity of contact surfaces. Acceleration, Velocity, Displacement - time waveform Refer SPEKTRA 16

Study for ISO Standard 16063-22 Shock Signal Generation by Hopkinson Bar Propagation and reflection characteristics of a mechanical wave in a slender bar. Slender bar : length / diameter >80 CMS Refer SPEKTRA Acceleration, Velocity - time waveform 17

Study for ISO Standard 16063-22 Pendulum Shock Calibrator Shock peak magnitude of 100 m/s 2 to 1500 m/s 2 with pulse durations of 3 ms to 8 ms are created with pendulum. 18

Study for ISO Standard 16063-22 Drop Shock Calibrator mounting of transducers, anvil, and test mass Shock peak magnitude of 100 m/s 2 to 100 km/s 2 with pulse durations of 0.1 ms to 10 ms are created with dropball. 19

Study for ISO Standard 16063-22 Pneumatically Operated Piston Shock Calibrator Shock peak magnitude of 200 m/s 2 to 100 km/s 2 with pulse durations of 0.1 ms to 3 ms are created with Pneumatically. Shock pulse in general are determined by velocity of projectile, the mass of the target and deformation of material between them. 20

Study for ISO Standard 16063-22 Others Oscilloscope : minimum frequency range from d.c. to 1 MHz Waveform recorder with computer interface: resolution >12 bit room temperature : (23±3) relative humidity:75 % maximum. Calculation of shock sensitivity for anvil shock calibrators Selection of maximum value as peak-value 21

Study for ISO Standard 16063-22 Uncertainty reference conditions for secondary shock calibration 22

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 23

Comparison Shock Calibration System in CMS from 1990 to 2008 GPIB Computer Scope Steel ball S u =(V u /V r ) S r mv ( m/ s S u : Sensitivity of DUT S r : Sensitivity of Std. shock accelerometer V u : Voltage of DUT V r : Voltage of Std. shock accelerometer 2 ) Charge amplifier ENDEVCO 2965C Standard accelerometer Calibrated accelerometer Reference accelerometer traces to PTB. Expanded Uncertainties 2.5 % with acceleration range from 1000 m/s 2 to 10000 m/s 2. Comparison Shock System 24

Comparison Shock Calibration System in CMS from 2008 to 2014 Reference accelerometer traces to PTB and NML. Expanded Uncertainties 2.1 % with acceleration range from 1000 m/s 2 to 10000 m/s 2. 25

Comparison Shock Calibration System in CMS 2015~ Extend to lower intensity for industry need 26

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 27

ISO 16063-13 Primary shock calibration using laser interferometry 2001 28

Study for ISO Standard 16063-13 Signal processing scheme for determining shock sensitivity 2 st () Shock exciter s( t ), v( t ), a ( t ) 1 a() t u ( t ) cos ( t ) p 1 H om odyne: Interferometery u ( t ) r sin( ( t ) ) q 2 Accelerometer H eterodyne: u ( t) u cos( t ( t)) h m h A/D 3 A/D Amplitude: u m Spectrum: U ( f ) U exp j U Modulation 1 ( n) 4 s( n) a Amplitude: Spectrum: m A( f ) A exp j A Shock sensitivity: S Complex sensitivity: S sh u a U m m exp j( ) a U A A 4 29

Study for ISO Standard 16063-13 1. Shock Exciter Hammer Impact Anvil Excitation 200 180 160 140 Rigid Body Motion 120 100 80 60 40 20 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 x 10-3 4 x 104 Hopkinson Bar Excitation 3 2 Wave Propagation 1 0-1 -2-3 -4 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 x 10-3 Shock signal 30

Study for ISO Standard 16063-13 Displacement, Velocity and Acceleration Curves for Excitation Hammer Impact Anvil Excitation T sin sec sec sec Half-sine squared acceleration shape Velocity Displacement 31

Study for ISO Standard 16063-13 2. Interferometer-- Michelson Interferometer Michelson Interferometer Homodyne One channel output 32

Study for ISO Standard 16063-13 2. Interferometer-- Michelson Interferometer input output Method Vibration Calibration Fringe-Counting Method Shock Calibration Time Sequence Method No phase calibration information 33

Study for ISO Standard 16063-13 2. Interferometer-- Modified Michelson Interferometer Modified Michelson Interferometer Homodyne Orthogonal signal output 34

Study for ISO Standard 16063-13 2. Interferometer-- Modified Michelson Interferometer input output Method Vibration Calibration u1 and u2 phase difference 90 Sine approximation Method Shock Calibration Phase Method Phase calibration information 35

Study for ISO Standard 16063-13 2. Interferometer Quadrature Signals Typical Quadrature Signals for Shock Excitation u1 cos ( t) p u2 r sin[ ( t) ] q u1 u2 sec sec 36

Study for ISO Standard 16063-13 3. Signal Data Processing u 2 u 1 u1( t) ( t) atan[ ( n ) ] u2( t ( t ) ) n S( t) ( t) 4 Quadrature signals a series of modulation phase values a series of displacement values 37

Study for ISO Standard 16063-13 3. Signal Data Processing Signal waveform produced by Shock system of CMS Displacement u1 u2 Velocity Acceleration Accelerometer output voltage Phase 38

Study for ISO Standard 16063-13 4. Calibration Result u max Shock Sensitivity a max S sh u a max max 39

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 40

Shock Calibration System in CMS System Structure Shock machine 9 0 90 11 12 Recorder 1 2 10 3 4 5 6 7 8 Interferometer Optical table Shock machine 1. Controller 2. Programmable DC supply 3. High speed electromagnetic hammer 4. Airborne hammer 5.Trigger unit 6. PU rubber 7. Airborne anvil 8. Accelerometer 9. Charge amplifier Interferometer 10. Laser 11. Ligh detectors Recorder 12.Digital scope: NI 5124-50 MHz 12 bit (Quadrature Interferometer signal) NI 5922-10 MHz 16 bit (Accelerometer output Voltage) 41

Shock Calibration System in CMS Calibration System Photo Recorder & Display Interferometer Shock machine Acceleration: 200 m/s 2 to 10000 m/s 2 Pulse duration : < 3 ms 42

Shock Calibration System in CMS Laser Interferometer (Modified Michelson interferometer + Mach-Zehnder interferometer) u 1 u 2 u 1 u 2 Quadrature signals 43

Shock Calibration System in CMS Shock Machine High speed electromagnetic hammer Airborne hammer : velocity up to 2.6 m/s Trigger device Airborne anvil Accelerometer Electromagnetic controller Vmax DC source supply Optical table Different hardness PU rubber Shore hardness 95/85/75/65/55 Porous Air Bushing : Allow Airborne anvil and hammer frictionless linear and rotary motion and radial air gap 4 µm. Cylindrical Anvil, Hammer length 200 mm, diameter 25 mm material : steel or aluminum. 44

Shock Calibration System in CMS Transverse Motion Ratio of peak acceleration between z- axis and x-,y- axis. Maximum transverse motion is about 4 % Y-axis X-axis Z-axis Triaxial accelerometer ENDEVCO 2270 and charge amplifier ENDEVCO 133, which accelerometer provides the excellent vibration characteristics: such as maximum transverse sensitivity 0.3 %. 45

Shock Calibration System in CMS Relative Motion Back-to back reference standard accelerometer is calibrated Accelerometer Reference Surface and the Spot Sensed by Interferometer 46

Shock Calibration System in CMS Different Rubber Black PU rubber shock time : 0.5 ms to 0.8 ms shock acceleration: 1160 m/s 2 to 5980 m/s 2 Two-layer red PU rubber shock time: 3 ms to 4 ms, shock acceleration: 130 m/s 2 to 950 m/s 2 47

Rubber V.S. Duration-Pilot Study Comparison Different Rubber 48

Shock Calibration System in CMS Calibration Procedure Turn on system and warm up 30 min. Room Temp.:(23.0 3.0) Relative Humidty:(50 20) % Ambient conditions check Mounting sensor and PU rubber Adjust interferometer signal Setting shock acceleration and input voltage Shock acceleration (m/s 2 ) Input Voltage (V) 200 17.4 1000 52.6 2000 44.8 3000 60.8 4000 78.2 5000 100 Conduct 10 times calibration 49

Shock Calibration System in CMS Software Function 50

Shock Calibration System in CMS Ten Times Measurement 51

Shock Calibration System in CMS Expression of Uncertainty of measurement in Calibration 52

Outline 1. Shock for Industry Application. 2. ISO Standard for Calibration of Vibration and Shock Transducers. 3. Study for ISO 16063-22. 4. Comparison Shock Calibration System in CMS. 5. Study for ISO 16063-13. 6. Primary Low Shock Calibration System in CMS. 7. References. 53

References Hong-Bo Hu, Yu-Chung Huang, Jiun-Kai Chen, Guest Reserach Report on Primary Calibration for Shock Acceleration in NML, 2011 ISO 16063-13, Methods for the calibration of vibration and shock transducers-part 13: Primary shock calibration using laser interferometry, 2001. Yu-Chung Huang, Measurement system validation procedure for shock accelerometer- phase operational method, ITRI, 2009. Yu-Chung Huang, Jiun-Kai Chen, Hsin-Chia Ho, Chung-Sheng Tu, Chao- Jung Chen, The Set Up of Primary Calibration System for Shock Acceleration in NML,IMEKO 20010 TC3, TC5 and TC22 International Conference, pp. 265-268, 2011. Hideaki Nozato, Takashi Usuda, Akihiro Oota, Tamio Ishigami and Katsuhisa Kudo, Development of Shock Acceleration Calibration Machine in NMIJ, IMEKO 20th TC3, 3rd TC16 and 1st TC22 International Conference, pp. 215-223, 2007. 54

Thanks for your attention 55