ph Probes Lab vs. Process Care, Calibrations and Comparison Presented by: Michael Blackburn Technical Sales Specialist at Hach Company

Similar documents
Understanding ph Troubleshooting and Diagnostic information

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

GENERAL INSTRUCTIONS GENERAL PREPARATION

Guide to ph Analysis.

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

GENERAL INSTRUCTIONS GENERAL PREPARATION

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

symphony Multisensor Probes

STANDARD OPERATING PROCEDURE

Combination ph, ORP, T Electrode with Transmitter

FOCUS: Water Pollkon Prevention and Control

symphony Reference Electrodes

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

DOC /2013, Edition 1. User Manual

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

Buffer Preparation. Learning Objectives:

ORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C

Rapid RH Portable ph Meter. User's Manual

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Differential ph Probe Type 18

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Chemistry Instrumental Analysis Lecture 23. Chem 4631

ELECTROCHEMISTRY Theory and Practice. DOC /2018, Edition 1

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Ion Selective Electrode Probe

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

ORP Probe ORP. Reads. +/-2000mV. Range. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C. Temperature range C.

Operating Instructions for Ammonium ISE Specifications

OPERATING INSTRUCTIONS

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Electrochemistry - Theory and Practice

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

Compact ph Measuring Instruments With Pro Engineering

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

Chemistry MultiMeasure Sensor PS-2170

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

10 samples per second

QAM-I-111 Operation and Calibration of the Conductivity Meter

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

Optimizing Coagulation with Streaming Current Plant Operations Conference Presented by the VA AWWA Plant Operations Committee

Manual ph Probe & Oxidation Reduction Potential Probe Models 6528A and 6528B

phoenix Electrode Company CARBON DIOXIDE GAS-SENSING ELECTRODE INSTRUCTION MANUAL 1. A ph/mv meter or an ion meter, either line operated or portable.

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

1) A ph/mv meter or an ion meter, either line operated or portable.

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes

A Case for Periodic Calibration or Verification of RTDs

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

MassWWP Standard Operating Procedure L-6 ph and Alkalinity Rev.0 Page 1 of 12

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

Bante210 Benchtop ph Meter Instruction Manual

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

GENERAL INSTRUCTIONS GENERAL PREPARATION

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

ph 5 Meter Manual The LaMotte 5 Series

POTASSIUM ION SELECTIVE ELECTRODE

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

Razi Vaccine & Serum Research Institute

ph electrodes with screw cap S7. Special application electrodes.

The original definition of ph, is the negative base 10 logarithm of the hydrogen ion concentration, or: ph = - log 10 [H + ]

Pain-Free Melting Point Determination. James Lee, Ph.D. Stanford Research Systems

NH 3 -selective electrodes

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Reference Electrode Salt Bridge Kit

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

Experimental Procedure. Lab 406

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

Instruction Manual Portamess 911 ph

Improve Lab Accuracy for Better Water Analysis

PH700 Benchtop ph Meter Instruction Manual

User Guide. Green ph Electrodes

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

Standard Operating Procedure for: ph using Oakton ph 5+ Handheld ph Meter. Missouri State University. and

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Point Level Capacitance Switch for Fly Ash Hopper Measurement

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Instruction Manual. Waterproof Portable Colorimeter C401 / 301 / 201 / 101 / 102 / 103 / 104 / 105. Part of Thermo Fisher Scientific

Transcription:

ph Probes Lab vs. Process Care, Calibrations and Comparison Presented by: Michael Blackburn Technical Sales Specialist at Hach Company

What Will We Cover Today? Calibrations vs. Validation Detection Methods Lab vs. Process Example of Calibrations & Maintenance (ph) Your questions.

Calibration vs. Validation Calibration Documented altering of the calibration curve Validation Checking of the current accuracy of the calibration curve

Detection Methods ISE Ion Selective Electrodes Probes ph, Conductivity Lab instrument calibrate every time you use Process instruments - quarterly Colorimetric Spectrophotometers, Colorimeters, (Hardness, Alkalinity, Chlorine) Annual calibration minimum! Scatter Detection Turbidity, Suspended Solids Lab and process calibrate quarterly

Lab vs. Process Should I be calibrating with the same frequency (Lab vs. Process)? Which instrument should I trust? Some lab equipment doesn t require calibration. How do I know the calibration is accurate?

ph Calibration and Maintenance What does ph stand for? How does it work? How often should I calibrate? What effects the calibration? Is it broken?

So How Do These Things Work??

Nernst Equation E = E 0-2.3RT log a i nf E = 59.16 mv per Decade @ 25 C

ph Measuring Electrode Typical Problems ph membrane coating Slow response due to high impedance Abrasion and/or breakage Temperature shock

Care of ph Electrodes Storage Store between 10 and 30 degrees C Use protective caps KCL or ph 4 buffer solution

Care of ph Electrodes Dehydration Slow response High glass resistance

Care of ph Electrodes Detrimental factors to electrode life Heat Cold Vibration

Sensor Cleaning Remove contaminate buildup

Sensor Cleaning Hach Recommends using: 4 ph buffer solution Or Liqui-Nox /Alconox Or Other mild acid To clean the probe

Sensor Cleaning Clean electrode surface 1. Rinse with water 2. Soak in 4 ph buffer 3. Clean with soft toothbrush 4. Rinse with water Wipe probe dry with soft towel

Sensor Cleaning Rinse and Calibrate

ph Sensor Verification Verification should be performed using buffer solutions Rinse with clean water and dry gently lint free lab cloth. Place the sensor in 7pH buffer, rinse with clean water and dry gently lint free lab cloth, then place it in the 4pH buffer. If the sensor is reading the buffers correctly you do not need to recalibrate.

ph Sensor Calibration Clean the sensor Calibration keystrokes will depend on analyzer used A two point buffer calibration preferred 7 and 4 ph calibration is ideal

ph Sensor Verification If verifying using a hand-held or portable meter Calibrate both the portable/handheld and the online system side by side in the same buffer solutions. Verify that both units slope fall within manufacturer specifications Be realistic with your expectations.

Inside Hach s Differential ph Sensors Salt Bridge Standard Cell Solution Fill Chamber and Reference Electrode

Frequency of Salt-Bridge/Standard Cell Solution Maintenance How often do I need to change the salt-bridge and reference solution on the ph/orp sensors? This is process dependent, but generally at least twice a year. What are the symptoms indicating the Saltbridge/standard cell solution need to be changed? System quickly goes out of calibration. The offset is greater than +/-20 mv.

Testing and Troubleshooting the Differential ph Sensor Temperature compensator Signal measured between yellow and black 300 ohm thermistor Inversely proportional to temperature 300 ohms at 25 degrees C Failures are normally an open or short

Testing and Troubleshooting a Differential ph Sensor Theoretical ph signals in buffer Measure between Red and Green wire 59.16 mv per ph 7 ph is isopotential point, 0 mv 4 ph is +177 mv 10 ph is -177 mv Offset is the mv signal in 7 ph buffer Deviation is the mv signal in 4 or 10 ph buffer

Testing and Troubleshooting a Differential ph Sensor Acceptable Offset and Deviation Tolerances Signal measured between red and green wires Offset should be 0 mv +/- 20 mv Deviation should be 160 mv from offset

Technical Support Contacts Contact us by phone at: 1-800-227-4224 Or email us at techhelp@hach.com

Field Support Contacts Mick Dollenmayer Regional Sales Manager Steve Kasprzyk Division Manger for Service

Questions???

ph Sensor Preventative Maintenance and Troubleshooting Please email any questions relating to this presentation to mblackbu@hach.com. Include in the subject line: Attn: ph maintenance presentation