Numerical Investigation of Natural Convection Loss in Cavity-Type Solar Receivers

Similar documents
A New Correlation for Predicting the Free Convection Loss from Solar Dish Concentrating Receivers

Natural Convection and Radiation Heat Loss from Open Cavities of Different Shapes and Sizes Used with Dish Concentrator

Chapter 9 NATURAL CONVECTION

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Numerical analysis of the influence of inclination angle and wind on the heat losses of cavity receivers for solar thermal power towers

Simulation of Free Convection with Conjugate Heat Transfer

Chapter 3 NATURAL CONVECTION

Effect of Periodic Variation of Sol-air Temperature on the Performance of Integrated Solar Collector Storage System

Simulation of a linear Fresnel solar collector concentrator

Chapter 7. Three Dimensional Modelling of Buoyancy-Driven Displacement Ventilation: Point Source

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Numerical Analysis of Laminar Natural Convection in a Quadrantal Cavity with a Solid Adiabatic Fin Attached to the Hot Vertical Wall

Influence of Heat Transfer Process in Porous Media with Air Cavity- A CFD Analysis

A 2-D Test Problem for CFD Modeling Heat Transfer in Spent Fuel Transfer Cask Neutron Shields. G Zigh and J Solis U.S. Nuclear Regulatory Commission

Project #1 Internal flow with thermal convection

Laminar natural convection in inclined open shallow cavities

Combined Natural Convection and Thermal Radiation in an Inclined Cubical Cavity with a Rectangular Pins Attached to Its Active Wall

Experimental study on heat losses from external type receiver of a solar parabolic dish collector

Numerical investigation of the buoyancy-induced flow field and heat transfer inside solar chimneys

PHYSICAL MECHANISM OF NATURAL CONVECTION

Flow patterns and heat transfer in square cavities with perfectly conducting horizontal walls: the case of high Rayleigh numbers ( )

COMPUTATIONAL ANALYSIS OF LAMINAR FORCED CONVECTION IN RECTANGULAR ENCLOSURES OF DIFFERENT ASPECT RATIOS

Effect of an adiabatic fin on natural convection heat transfer in a triangular enclosure

Convection. forced convection when the flow is caused by external means, such as by a fan, a pump, or atmospheric winds.

Introduction to Heat and Mass Transfer. Week 14

Patrick H. Oosthuizen and J.T. Paul Queen s University Kingston, ON, Canada

Natural Convection in Parabolic Enclosure Heated from Below

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Vertical Mantle Heat Exchangers for Solar Water Heaters

NUMERICAL STUDY OF MIXED CONVECTION AND THERMAL RADIATION IN A SQUARE CAVITY WITH AN INSIDE INCLINED HEATER

EFFECT OF THE INLET OPENING ON MIXED CONVECTION INSIDE A 3-D VENTILATED CAVITY

HEFAT th International Conference on Heat Transfer, Fluid Mechanics, and Thermodynamics September 2005, Cairo, Egypt AA10

CFD ANALYSIS OF TRIANGULAR ABSORBER TUBE OF A SOLAR FLAT PLATE COLLECTOR

THERMAL PERFORMANCE EVALUATION OF AN INNOVATIVE DOUBLE GLAZING WINDOW

FLUID FLOW AND HEAT TRANSFER INVESTIGATION OF PERFORATED HEAT SINK UNDER MIXED CONVECTION 1 Mr. Shardul R Kulkarni, 2 Prof.S.Y.

Chapter 7: Natural Convection

Optimization of the Air Gap Spacing In a Solar Water Heater with Double Glass Cover

INSTRUCTOR: PM DR MAZLAN ABDUL WAHID

Analysis of the Cooling Design in Electrical Transformer

Natural Convection from Horizontal Rectangular Fin Arrays within Perforated Chassis

Study ANTALYA. Abstractt. number. reflecting. any specially an importantt solar thermal. of the aperture area to the

Natural Convection Heat Loss from A Partly Open Cubic Enclosure Timothy N Anderson 1,a * and Stuart E Norris 2,b

Table of Contents. Foreword... xiii. Preface... xv

MAE 598 Project #1 Jeremiah Dwight

MIXED CONVECTION HEAT TRANSFER FROM A PARTICLE IN SUPERCRITICAL WATER

NATURAL CONVECTION HEAT TRANSFER IN PARTIALLY OPEN ENCLOSURES CONTAINING AN INTERNAL LOCAL HEAT SOURCE

NATURAL CONVECTION OF AIR IN TILTED SQUARE CAVITIES WITH DIFFERENTIALLY HEATED OPPOSITE WALLS

MIXED CONVECTION IN A SQUARE CAVITY WITH A HEAT-CONDUCTING HORIZONTAL SQUARE CYLINDER

Effect of Buoyancy Force on the Flow Field in a Square Cavity with Heated from Below

Turbulent Natural Convection in an Enclosure with Colliding Boundary Layers

Heat transfer increase with thin fins in three dimensional enclosures

LAMINAR NATURAL CONVECTION IN VERTICAL 2D GLAZING CAVITIES

THE CHARACTERISTIC LENGTH ON NATURAL CONVECTION FROM A HORIZONTAL HEATED PLATE FACING DOWNWARDS

Convection Workshop. Academic Resource Center

Vector and scalar variables laminar natural convection in 2D geometry arbitrary angle of inclination

Numerical Study of Free Convection Heat Transfer in a Square Cavity with a Fin Attached to Its Cold Wall

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

Journal of Engineering Research and Studies E-ISSN

Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions

CONVECTION HEAT TRANSFER

Y. L. He and W. Q. Tao Xi an Jiaotong University, Xi an, China. T. S. Zhao Hong Kong University of Science and Technology, Kowloon, Hong Kong, China

Atrium assisted natural ventilation of multi storey buildings

FINITE ELEMENT ANALYSIS OF MIXED CONVECTION HEAT TRANSFER ENHANCEMENT OF A HEATED SQUARE HOLLOW CYLINDER IN A LID-DRIVEN RECTANGULAR ENCLOSURE

Advanced Heat and Mass Transfer by Amir Faghri, Yuwen Zhang, and John R. Howell

EFFECT OF DISTRIBUTION OF VOLUMETRIC HEAT GENERATION ON MODERATOR TEMPERATURE DISTRIBUTION

Numerical Investigation of Convective Heat Transfer in Pin Fin Type Heat Sink used for Led Application by using CFD

Analysis of the flow and heat transfer characteristics for MHD free convection in an enclosure with a heated obstacle

Research Article Study of the Transient Natural Convection of a Newtonian Fluid inside an Enclosure Delimited by Portions of Cylinders

UNIT II CONVECTION HEAT TRANSFER

Numerical Investigation of Fluid and Thermal Flow in a Differentially Heated Side Enclosure walls at Various Inclination Angles

FREE CONVECTIVE HEAT TRANSFER FROM AN OBJECT AT LOW RAYLEIGH NUMBER

CONVECTION HEAT TRANSFER

NUMERICAL STUDY OF HEAT TRANSFER IN A FLAT PLAT THERMAL SOLAR COLLECTOR WITH PARTITIONS ATTACHED TO ITS GLAZING. Adel LAARABA.

Numerical Investigation of Conjugate Natural Convection Heat Transfer from Discrete Heat Sources in Rectangular Enclosure

Numerical Investigation of Thermal Performance in Cross Flow Around Square Array of Circular Cylinders

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

EFFECT OF AN AXIAL HOLE ON NATURAL CONVECTION HEAT TRANSFER FROM A CYLINDRICAL PIN FIN ATTACHED TO A HORIZONTAL PLATE

INTERNATIONAL JOURNAL OF ADVANCED RESEARCH IN ENGINEERING AND TECHNOLOGY (IJARET)

This file contains the author's copy of:

The Natural Convective Heat Transfer in Rectangular Enclosure Containing Two Inclined Partitions

Using FLOTHERM and the Command Center to Exploit the Principle of Superposition

Natural Convection Heat Transfer inside a Narrow Triangular Enclosure with Rectangular Staggered Finned Base Plate: An Empirical Correlation

Heat Loss from Cavity Receiver for Solar Micro- Concentrating Collector

CFD STUDIES IN THE PREDICTION OF THERMAL STRIPING IN AN LMFBR

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Tutorial 11. Use of User-Defined Scalars and User-Defined Memories for Modeling Ohmic Heating

Heat Transfer Convection

Cooling by Free Convection at High Rayleigh Number of Cylinders Positioned Above a Plane

Project 4: Navier-Stokes Solution to Driven Cavity and Channel Flow Conditions

Comparison of CFD Natural Convection and Conduction-only Models for Heat Transfer in the Yucca Mountain Project Drifts

FALLING FILM FLOW ALONG VERTICAL PLATE WITH TEMPERATURE DEPENDENT PROPERTIES

NATURAL CONVECTIVE HEAT TRANSFER FROM A RECESSED NARROW VERTICAL FLAT PLATE WITH A UNIFORM HEAT FLUX AT THE SURFACE

Entropy 2011, 13, ; doi: /e OPEN ACCESS. Entropy Generation at Natural Convection in an Inclined Rectangular Cavity

A numerical study of heat transfer and fluid flow over an in-line tube bank

EXPERIMENTAL AND NUMERICAL STUDIES FOR FLAME SPREAD OVER A FINITE-LENGTH PMMA WITH RADIATION EFFECT

Iterative calculation of the heat transfer coefficient

Transcription:

Numerical Investigation of Natural Convection Loss in Cavity-Type Solar Receivers S. PAITOONSURIKARN and K. LOVEGROVE Centre of Sustainable Energy Systems, Department of Engineering, Australian National University, Canberra ACT, AUSTRALIA Telephone: +61 2 6125 8299 Facsimile: +61 2 6125 56 E-mail: Sawat.Paitoonsurikarn@anu.edu.au Abstract In solar thermal systems, especially for high concentration applications, natural convection contributes a significant fraction of energy loss. Its characteristics hence need to be understood so that it can be effectively minimized in order to improve system efficiency. The present study numerically investigates the influence of cavity geometry and inclination on the convective loss through the aperture. The Computational Fluid Dynamics package Fluent 6. has been used to investigate three cases of geometrically different receivers. The calculated heat loss results shows a nonlinear dependence on the inclination angle and shows qualitatively good agreement with those calculated by various previously proposed empirical models. The Clausing model (1981) shows the closest prediction to both numerical and experimental results despite its original use for larger-scale central receiver systems. 1 INTRODUCTION The Australian National University (ANU) has been involved with the investigation of solar thermal energy conversion using paraboloidal dish concentrators for many years. Currently the team is undertaking R&D on a 4 m 2 concentrator fitted with a monotube boiler cavity receiver for superheated steam production and a m 2 concentrator that operates a cavity receiver lined with reactor tubes for ammonia dissociation for energy storage (Johnston et al, 1)&(Lovegrove et al, 1)&(Luzzi et al, 2). In such systems, the receivers experience three modes of heat loss; conduction loss through the wall, convection and radiation losses through the aperture all of which need to be minimized in order to improve the receiver performance. In general, conduction and radiation losses can be determined relatively easily using standard methods (e.g. Holman, 1997). On the other hand, the determination of convection loss is rather difficult and usually relies on semi-empirical models This paper reports some initial results obtained from the simulation of the convection losses from the ANU dish receivers using the Computational Fluid Dynamics (CFD) package Fluent. The study complements a parallel experimental investigation using an electrically heated model of a cavity receiver that is also reported in these proceedings (Taumoefolau 2). 1.1 Previous Work There have been several previous investigations of natural convection heat loss from open-cavities. Le Quere et al (1981) studied the heat loss from an isothermal cubic cavity in the range of 1 7 < Ra < 1 9. The total heat loss was found to be strongly dependent on the cavity inclination and the correlation for each inclination was established. Clausing (1981) hypothesized that two factors governed the convective heat loss, i.e., (i) the ability to transfer mass and energy across the aperture and (ii) the ability to heat air inside the cavity. A simplified analytical method was developed based on the above assumption. He concluded that the latter factor was of greatest importance. Hess et al (1984) investigated the natural convection losses from horizontal rectangular cavities for large Rayleigh number (Ra >1 1 ). They found that the use of a flow restriction at the aperture plane could reduce natural heat loss by about 1%. In addition to physical experiments, Eyler (198) carried out the 2D simulation of the convective heat loss from large rectangular cavities whose dimensions (depth x height) were 2.59m x 2.88m and 12.95m x 14.35m. He found a nonlinear dependence of heat loss with respect to cavity size, receiver inclination, and aperture diameter. Notably, however, all of these investigations addressed large scale cavities such as those employed in central receiver applications and so the results need to be carefully verified if used for smaller scale ones. Among a handful of research

papers on small scale cavities applicable to solar dishes, Koenig and Marvin developed a heat loss model based on relatively high cavity temperature between 55 o C and 9 o C, which was summarized in the comprehensive review by Anderson et al (1987). Stine et al (1989) extended the work by Siebers et al (1984), which was originally applicable only for central-receiver. They included the effects of varying aperture size and receiver inclination. Recently, Leibfried et al (1995) developed two new generalized models that can be used for both downward and upward facing cavities with various geometries. The two proposed models were based on another work by Clausing et al (1987) in which a model was derived from the experimental data from a cubical cavity, and by Stine et al (1989). The modifications of Clausing s and Stine s Models were primarily in order to take into account the different flow pattern while the cavity was facing upward and the effect of different geometries of the cavities. Leibfried verified the two modified models with experiments on spherical and hemi-spherical cavities and found very good agreement. The Rayleigh number in their experiment varied between 1 7 and 1 9, which implies that most of the flow regime was laminar. Although there have been a few experimental models developed so far, their range of applicability for different cavity geometries is not clear. 2 NUMERICAL PROCEDURE 2.1 Problem Formulation The CFD Software Package, Fluent 6. (Fluent Inc., 2) is being employed in the 3D simulation of natural convection. In reality, the receiver is surrounded by an infinite atmosphere with a limiting temperature equal to ambient air temperature. To model this condition in the CFD analysis, the flow domain is established such that the receiver is centrally placed in a sufficiently large enclosure with walls at ambient temperature as schematically shown in Fig. 1a. Figs. 2a to 2c illustrate the cross sections and relevant dimensions of the three receivers considered. The model shown in Fig. 2a represents the experimental receiver model constructed and characterized by Taumoefolau (2). The other two shown in Figs. 2b and 2c are essentially the replications of the actual receivers currently employed in the ANU m 2 and 4 m 2 dishes, respectively. The size of the virtual enclosure was increased until it had an insignificant effect on the predicted fluid and heat flows in the vicinity of the receiver. Eyler (198) stated that as long as the exterior region of the cavity extended beyond a distance about equal to the interior cavity depth, the effect on flow and heat transfer inside the receiver was negligible. However, in this study it was found that the diameter of the cylindrical enclosure should be about twenty times the diameter of the receiver to achieve this. (a) Model receiver (b) m 2 dish receiver (b) (a) Fig. 1 Schematic diagram of flow configuration: (a) the receiver location in the entire domain, (b) the m 2 dish cavity receiver showing the angle of inclination. (c) 4 m 2 dish receiver Fig. 2 Cross sectional diagram of all three receiver models. 2 Proceedings of Solar 2 Australian and New Zealand Solar Energy Society Paper 1

(a) (b) Fig. 3 Typical computational grids for (a) model receiver and (b) 4 m 2 dish receiver. Note that these figures also show the mirror image opposing across the symmetrical plane. Grid dependency was investigated and the final grids used consist of approximately 2x1 5 hexahedral cells. The cells are very small in the region inside the cavity and nearby the receiver but increase in size gradually toward the cylindrical enclosure wall. Fig. 3 shows the typical grids used for the laboratory model and 4 m 2 dish receiver cases. 2.2 Modeling Equations The flow and heat transfer simulation is based on the simultaneous solution of the system of equations describing the conservation of mass, momentum, energy and turbulent transport property. The Spalart-Allmaras one-equation turbulent model recommended by Spalart () is employed. The steady-state governing equations are solved in Fluent using a coupled solver, which means that temperature and flow fields are coupled with each other and are solved simultaneously. All temperature-dependent properties of fluid, i.e. air, such as density are evaluated at local temperature by using the least-square fit equations derived from thermodynamic data compilations taken from (Holman, 1997). 2.3 Boundary Conditions The isothermal boundary condition was applied to cavity wall, whereas the outer walls of the receivers were assumed to be adiabatic. The cavity wall temperatures used were: - For the model receiver, the average experimental values of cavity wall temperature data of 445 o C and 48 o C were used for the cylindrical section and circular end plate, respectively. - For the m 2 dish receiver, the typical experimental data of cavity wall temperature data were used, which were 637 o C, 655 o C and 576 o C for the annular section surrounding the aperture, frustum section and circular back section, respectively. - For the 4 m 2 dish receiver, the temperature of the whole cavity wall was arbitrarily set at 627 o C. The wall temperature of the entire cylindrical enclosure was set to T amb =27 o C. Normal velocity and normal gradients of all flow variables were set to zero across the vertical plane of symmetry. The inclination of the cavity as shown in Fig. 4b was simulated by redirecting the gravity vector to the desired direction. The gravitational constant was specified to the standard value of 9.8665 m/s 2. 2.4 Solution Criterion The initial guesses for velocity, temperature, and turbulent viscosity fields were set to constant values over the entire computational domain. To obtain the flow and heat transfer solutions, the solver undertakes iteration until the convergence criterion is satisfied, which employs scaled residuals of the modified variables in the governing equations as the measure. In addition, the averaged cavity wall heat flux was examined explicitly for convergence (to less than a.1% variation between iterations). Typical computational time takes about 3 hours on one CPU of a Compaq ES45 Alpha 1-GHz machine. Proceedings of Solar 2 Australian and New Zealand Solar Energy Society Paper 1 3

(a) o (b) 3 o (c) 6 o Fig. 4 Contour plot of velocity magnitude at symmetry plane for model receiver. 3 1.3.65.7.6.55.5.4.45.35.1.25.3.2.2.15.15.1.5.5.5 -.5 -.5.2 -.1.25 3 1 -.5.45.4.35.3.25.2.2.15.15.1.1.5.5.25 3 1 -.6.18.14.16.1.12.1.8.8.6.6.4.4.2.2 -.6-1 - -.15-1 - -.5 -.5-1 - -.2 -.2-3 -.2-3 -.1-3 -.4 -.8 -.1-3 - -1 1 3-3 - -1 1 3-3 - -1 1 (a) o (b) 3 o (c) 6 o 3 3 1 6 5 6 64 66 6 6 6 68 58 54 56 5 46 48 44 4 4 38 36 34 3 64 3 1 6 68 68 7 66 7 6 6 6 58 6 56 64 54 5 48 46 4 44 4 38 36 3 5 3 1 6 64 7 66 7 68 64 6 6 6 64 6 58 56 5 54 5 46 48 44 4 4 38 36 34 3 68-1 -1 6-1 - - - -3-3 34-3 -3 - -1 1 3-3 - -1 1 3-3 - -1 (d) o (e) 3 o (f) 6 o Fig. 5 Profiles at aperture plane for model receiver: (a)-(c) normal velocity (m/s), (d)-(f) temperature (K). 1 3 3 RESULTS AND DISCUSSIONS 3.1 Results for Model Receiver Contour plots of velocity magnitude in the symmetry plane of the model receiver at angles of o, 3 o, and 6 o are presented in Figs. 4a) to c). In each figure the color represents the relative magnitude and so cannot compare to those in other figures. It is evident that the predicted flow pattern is in agreement with what is intuitively expected. At an inclination angle of o, the cold air enters the cavity at the lower half of the aperture and flows along the lower part of the cavity where it is heated. The air reaches the back wall and flows upward until it encounters the upper cavity wall. The air then flows back along it and finally exits the cavity. A relatively stagnant core is observed in the middle of the cavity. The hot plume of air coming out from the upper half of the aperture flows directly upward without attachment to the frontal part of the receiver. The plume spreads out with decreasing velocity due to both the viscous effect and reduction of induced buoyancy force caused by cooling of the plume. The flow patterns at angles of 3 o and 6 o are quite similar but with the addition of a stagnant zone and local circulation in the upper part of the tilted cavity due to the stable stratification of temperature. In these cases the exiting hot plume attaches to the front of the receiver before separating at the receiver s edge and spreading out. Figs. 5a) to f) show the corresponding profiles of normal velocity and temperature in the aperture plane. They clearly show that the inflow and outflow of air occupies the lower and upper halves of the aperture respectively. The maximum outflow velocity occurs near the top, whereas the maximum inflow velocity occurs near the bottom. The magnitude of both decreases with increasing angle. The inflow area is not significantly different between angles of o and 3 o, just slightly greater for the latter, as can be seen from the area below the line of zero velocity depicted in Figs. 5a) and b). 4 Proceedings of Solar 2 Australian and New Zealand Solar Energy Society Paper 1

However, for angle=6 o shown in Fig. 5c), the inflow area is reduced as a result of the flow blockage which is primarily caused by the augmentation of the stagnation region inside the cavity. The temperature of the bulk air entering the cavity is about 3 K (or 47 o C) in all cases, which is higher than the ambient temperature of 3 K. This shows that the incoming air is heated by mixing with the exiting hot plume before it enters. The heat loss from the cavity was determined both from integrating the heat loss from the cavity wall and from the net enthalpy flow rate through the aperture. The agreement was within numerical accuracy. The comparison between the present numerical and corresponding experimental results of convection loss together with those predicted from various previously proposed correlations is reported in the parallel paper by Taumoefolau (2). It illustrates that all heat loss results decrease monotonically with increasing angle as also suggested by the flow fields shown in Fig. 4 and 5. The numerical results coincide with the experiment at the angle of inclinations = o and 9 o, but shows the slight overestimation at intermediate angles. However, considering the uncertainty associated in both results, the agreement is considerably good. 3.2 Examination of ANU Receiver Geometries CFD calculations have been applied to the geometries of the two cavity receivers on the ANU dishes. The results of flow and heat transfer characteristics for both are qualitatively similar to those of the model receiver shown in Figs. 4 and 5, despite the fact that the length scale and operating condition are different. The calculated total heat losses are plotted in Figs. 6 and 7, together with the predictions of the various correlations identified in section 2. The CFD result lies in the same range of most of those predicted. The Stine and McDonald model shows the greatest deviation from the others. As stated in the work by Leibfried et al (1995), it tends to overestimate the convective losses at high cavity temperature and can be improved if the reference temperature is changed to film temperature, i.e., the average of cavity and ambient temperatures. This is one of the improvements employed in the modified Stine & McDonald model. The Koenig & Marvin model shows fairly good agreement with the numerical results, which correlates with the fact that it was derived from the data of actual receivers of similar sizes to those used on the ANU dishes. The Clausing model shows excellent agreement to the numerical results for the 4 m 2 dish receiver, whereas the modified Clausing and Stine & McDonald models do for the m 2 dish receiver. Considering the uncertainty quoted in each correlation, the comparison shows that, despite their actual range of applicability, all correlations except the original Stine & McDonald model can predict the convective heat loss of the actual size receivers within a similar range and hence might be used interchangeably. Nonetheless, the original Clausing model is recommended as it can best correlate the present result in all cases considered including those from the experiment by Taumoefolau (2). Note that, all of the correlations examined predict zero natural convective loss at 9 o angle. This is physically implausible and indeed both the experimental measurements and CFD calculation from this study indicate that this is not the case. 4 CONCLUDING REMARKS The numerical investigation of natural convection heat loss from cavity receivers of solar dishes has been carried out. The numerical results obtained are qualitatively in good agreement with those predicted by various previously proposed correlations. The Clausing model (1981) shows the closest prediction despite its original use for bigger-scale central Heat Loss (W) 3 25 15 1 Koenig & Marvin Stine & McDonald Modified Stine & McDonald Clausing Modified Clausing Present Numerical Result 25x1 3 Heat Loss (W) 15 1 Koenig & Marvin Stine & McDonald Modified Stine & McDonald Clausing Modified Clausing Present Numerical Result 5 5 4 6 8 1 Inclination φ (degree) Fig. 6 Comparison of natural convection heat loss through the aperture for m 2 dish receiver. 4 6 Inclination φ (degree) Fig. 7 Comparison of natural convection heat loss through the aperture for 4 m 2 dish receiver. 8 1 Proceedings of Solar 2 Australian and New Zealand Solar Energy Society Paper 1 5

receivers. The discrepancy of convective heat loss at an orientation of 9 o between the present results and the predictions of correlations taken from the literature requires further investigation. More generalized study of mixed convection, i.e. including wind effect, will be conducted in the next step. The final goal is to develop an improved correlation that can reliably predict convective losses from cavity receivers on dish concentrators at all angles. 5 REFERENCES Anderson R. and Kreith F. (1987), Natural Convection in Active and Passive Solar Thermal Systems, Adv. Heat Transfer 18, 1-86. Clausing A.M. (1981), An Analysis of Convective Losses From Cavity Solar Central Receiver, Sol. Energy 27, 295-3. Clausing A.M., Waldvogel J.M., and Lister L.D. (1987), Natural Convection from Isothermal Cubical Cavities with A Variety of Side-Facing Apertures, ASME J. Heat Transfer 19, 47-412. Eyler L.L. (198), Prediction of Convective Losses from A Solar Cavity Receiver, In Proceedings for the Century 2 Solar Energy Conference, San Francisco, California. Fluent Inc. (2), Fluent 6 User Guide. Hess C.F. and Henze R.H. (1984), Experimental Investigation of Natural Convection Losses from Open Cavities, J. Heat Transfer 16, 333-338. Holman, J.P. (1997), Heat transfer. 8th edition, New York: McGraw-Hill Companies. Johnston G., Burgess G., Lovegrove K., and Luzzi A. (1), Economic Mass Producible Mirror Panels for Solar Concentrators, Proceedings of ISES World Congress, Adelaide, Australia. Leibfried U. and Ortjohann J. (1995), Convective Heat Loss from Upward and Downward-Facing Cavity Solar Receivers: Measurements and Calculations, J. Sol. Eng. 117, 75-84. LeQuere P., Penot F., and Mirenayat M. (1981), Experimental Study of Heat Loss through Natural Convection from An Isothermal Cubic Open Cavity, Proceedings DOE/SERI/SNLL workshop on convective losses from solar receivers, Sandia Laboratory Report SAND81-814, Livermore, California, 165-174. Lovegrove K., Luzzi A., Soldiani I., and Kreetz H. (1), Developing Ammonia Based Thermochemical Energy Storage for Dish Power Plants Smelly Experiments, Good Technology, Proceedings of ISES World Congress, Adelaide, Australia. Luzzi A., Lovegrove K., Paitoonsurikarn S., Siangsukone P., Johnston G., Burgess G., Joe W., and Major G. (2), Paraboloidal Dish Solar Concentrator Investigations at the ANU an update, Proceedings of the international symposium on concentrated solar power and chemical energy technologies, Zurich. Siebers D.L. and Kraabel J.S. (1984), Estimating Convective Energy Losses from Solar Central Receivers, Sandia National Laboratories Report, SAND 84-8717. Spalart P.R. (), Strategies for Turbulent Modeling and Simulations, Int. Journal of Heat and Fluid Flow 21, 252-263. Stine W.B. and McDonald C.G. (1989), Cavity Receiver Heat Loss Measurements, presented at ISES World Congress, Kobe, Japan. Taumoefolau T. (2), An Experimental Study of Natural Convection Heat Loss from A Solar Concentrator Cavity Receiver at Varying Orientation, In Proceedings of ANZSES Annual Conference, Newcastle, Australia. 6 Proceedings of Solar 2 Australian and New Zealand Solar Energy Society Paper 1