Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Similar documents
Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

OVERVIEW INTRODUCTION

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run

UPLC Intact MASS Analysis Application Kit

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

ANALYSIS OF POLYMER BLENDS BY GPC-FTIR

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Basic Principles for Purification Using Supercritical Fluid Chromatography

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

Routine MS Detection for USP Chromatographic Methods

HYPHENATED TECHNOLOGY GUIDE

Differentiation of polymer branching and composition using the Mark Houwink plot

Practical Steps in GPC Method Development

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

How to use GPC/SEC for compositional analysis

HYPHENATED TECHNOLOGY GUIDE

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Optimizing GPC Separations

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

One-pot polymer brush synthesis via simultaneous isocyanate coupling chemistry and grafting from RAFT polymerization

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Varian Galaxie Chromatography Data System for Preparative HPLC

Peptide Isolation Using the Prep 150 LC System

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Controlling Multicompartment Morphologies Using Solvent Conditions and Chemical Modification

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Molecular Weight Distribution of Living Chains in Polystyrene Pre-pared by Atom Transfer Radical Polymerization

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Scheme 1: Reaction scheme for the synthesis of p(an-co-mma) copolymer

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

GPC / SEC Theory and Understanding

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Photolabile Protecting Groups: A Strategy for Making

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

INTRODUCTION OVERVIEW

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

APC Hyphenated to SYNAPT-G2: Potential For The Analysis Of Complex Synthetic Polymers. Marie-Theres Picker Artjom Döring Dirk Kuckling

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Polymer analysis by GPC-SEC. Technical Note. Introduction

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Supporting Information

Introduction to Fourier Transform Infrared Spectroscopy

[ a ppl ic at ion no t e ]

Field-Flow Fractionation of Macromolecules and Structures That Cannot be Characterized by Conventional GPC/SEC Techniques

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Novel Tri-Block Copolymer of Poly (acrylic acid)-b-poly (2,2,3,3,4,4,4- hexafluorobutyl acrylate)-b-poly (acrylic acid) Prepared via Two-Step

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

GPC/MS. Analysis of PET

of Polystyrene 4-arm Stars Synthesized by RAFT- Mediated Miniemulsions.

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

LC Technical Information

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

CHALLENGES IN MICROPLASTICS IDENTIFICATION IS ONE DETECTION METHOD ENOUGH?

POLYMER ANALYSIS APPLICATIONS

Pittcon P

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

3) In CE separation is based on what two properties of the solutes? (3 pts)

GPC/SEC standards. Product guide

Chromatographic Separation

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Tips & Tricks GPC/SEC: Inter-Detector Delay

Ring-Opening Polymerization of N-Carboxyanhydrides Initiated by a Hydroxyl Group

GPC/SEC standards. Product guide

A novel smart polymer responsive to CO 2

CHEM 429 / 529 Chemical Separation Techniques

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Transcription:

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Michael O Leary 1, Jennifer Gough 1, Damian Morrison 1, Alain Creissen 2 1 Waters Corporation, Milford, MA USA, 2 HTX Technologies LLC, Chapel Hill, NC, USA OVERVIEW Assess the potential of adding Fourier Transform Infrared (FTIR) analysis to a Size Exclusion Chromatography (SEC) system, to explore operational conditions and their impact on FTIR data generated. High speed/high resolution SEC experiments are supported using Waters ACQUITY Advanced Polymer Chromatography (APC ) System, enabling rapid solvent exchange between experiments, and modified FTIR parameters while maintaining chromatographic performance. The potential benefits are explored highlighting the spectral identity and effect on chromatographic detector quality. INTRODUCTION Advances in polymerization processes have expanded from traditional condensation polymerization and free radical polymerization to include processes such as anionic polymerization, emulsion polymerization, RAFT, ATRP, and others. The development has evolved from simple polymer chains to complex polymers capable of performing multiple functions within a single molecular chain. As these new materials evolve, their control and understanding have come under intense scrutiny, requiring a wide range of analytical technology ranging from chromatographic separation to advanced mass spectrometry. 1, 2 Addressing the challenges of material characterization has often been focused on hyphenated detection techniques coupled with separation. This approach utilizes a concentration detector such as a refractive index (RI) detector and/or ultra violet (UV) detection coupled to other analyte specific type detection. 3 With the introduction of high speed / high resolution size-based separation techniques, the resolution and speed of the separation is maintained from injection to detection with traditional detector options such as RI and UV detection. This novel approach to the design of the APC separation equipment, including the separation column and entire flow path, are used to yield high resolution. However, the use of this high speed high resolution separation technique has seen limited pairing with offline sample analysis techniques such as infrared spectroscopy. 4 In this poster note, the expansion of the Waters Advanced Polymer Chromatography (APC) approach to the size-based separation is presented. Utilizing a controlled split flow, the sample is diverted to both a Waters ACQUITY Refractive Index Detector (RI) and an HTX LC -Transform 700 sample collection system (LC-T 700) for Fourier Transform Infrared (FTIR) analysis while maintaining the required system dispersion control needed for the APC experiment. 5 Figure 1.Waters ACQUITY APC SEC Core 1 System with post column split flow to the ACQUITY RI Detector and the HTX Technologies LC-Transform 700 sample collection system. TO DOWNLOAD A COPY OF THIS POSTER NOTE, VISIT WWW.WATERS.COM/POSTERS 1

EXPERIMENTAL Conditions for demonstration measurements The test conditions are based on using a high speed, high resolution ACQUITY APC SEC Core 1 System coupled to an HTX Technologies LC-Transform 700 sample collection system, the LC-T 700. The two detectors are managed by using a post column split flow at a fixed 1:1 ratio, (Figure 1). Samples evaluated are a mixture of two narrow polystyrene standards and a mixture of a narrow polystyrene standard and a narrow polymethylmethacrylate standard dissolved in the chromatographic system mobile phase. All LC-T 700 samples were collected on a germanium disk. The germanium disk was evaluated using the Bruker Tensor II FTIR bench, fitted with a reflection stage produced by PIKE Technologies, specifically designed for the evaluation of the LC-T 700 collection disks. SEC conditions System: Waters APC Core 1 Eluent: Flow rate: THF 1.0 ml/min Sample concentration: 1 mg/ml of each narrow standard (2 mg/ml total) Injection volume: 10 μl Column temp.: 40 C Columns: Waters 4.6 x 150 mm APC XT 450 Å, 125 Å and 45 Å in series Conc. detector: Waters ACQUITY RI at 40 C LC-T 700 detector: Split ratio: Conditions below HTX LC-T 700/RI 1:1 using two equal lengths of 0.004 inches ID SS tubing LC-T Conditions (optimized for APC chromatography) LC-T 700 system: HTX LC-Transform 700 Probe temp.: 90 C Nebulizer gas: Nitrogen Gas flow: 3.0 L/min. Spray nozzle height: 5 mm above the disk surface Sampling rate: 100 degrees/min. Collection delay: 2 min. Sample collection: 310 degrees of rotation LCT disk FTIR reader conditions Data collection: Resolution: 4 cm -1 Number of scans: 8 Chromatographic system control Bruker Opus System with LC-T 4 driver Waters Empower 3 FR2 Software was used for instrument control, data acquisition, and chromatographic data processing. 2

RESULTS AND DISCUSSION In this study, two sample sets were studied to assess the capability and impact of band spread of the LC-T 700 FTIR. The two samples are chosen to contain 55,000 Dalton (Da) and 31,000 Da polystyrene (PS) and 55,000 Da PS and 31,600 Da polymethylmethacrylate (PMMA). A split flow is used to send a portion of the sample sets to the RI detector, and the resulting APC chromatograms are used to indicate the resolution of the analysis (Figure 2). The two narrow polymer samples are from a single injection collected on the rotating germanium disk in the LC-T 700 collection device (Figure 3). The two red arrows point to the collection of each narrow polymer distribution corresponding to their chromatographic elution profile. The germanium disk inserted in the LC-T FTIR accessory allows for the collection of the spectra as a function of the rotational location corresponding to the elution time or volume (Figure 4). The small red dot is the focal point of the data collection. Using the sampling rate of FINE, the spectra is collected at every degree of rotation, or every 0.01 minutes as specifically done in this experiment. Figure 3 The above image is the germanium collection disk in the HTX LC-T 700. The two spots identified by the red arrows indicate the deposit of the two narrow polystyrene samples collected (top 55000 Da bottom 31000 Da. Figure 2. Top chromatogram is a mixture of narrow molar mass PS centered at 55,000 Da and 31,000 Da collected on an RI detector. Bottom chromatogram is a mixture of narrow molar mass PS centered at 55,000 Da and PMMA centered at 31,600 Da collected on an RI detector. Figure 4. LC-T 700 FTIR Interface. The white arrows pointing to the focused IR collection point (red dot) on the germanium disk. 3

The typical FTIR spectra collected in Transmission mode is demonstrated below (Figure 5). If the spectra is converted from transmission to absorbance, the local maxima can be selected for polystyrene at 701 cm -1 and for polymethylmethacrylate 1726 cm -1. The relative concentration of each narrow polymer standard can be collected as a function of elution volume. Comparing the signal from the split chromatographic flow, using the refractive index detector (black) and the LC-T 700 collection for FTIR analysis (red), a great match is observed between the detectors for the mixed PS sample (Figure 6-top). The comparison of the two detector modes shows an acceptable ~20% band spread with the FTIR measurement. Processing the FTIR data for the second sample (Figure 6-bottom), a mixture of 55,000 Da PS and 31,600 Da PMMA, two different frequencies are measured: 701 cm -1 for PS (red) and 1726 cm -1 for PMMA (green). These plots are overlaid with the signal from the refractive index detector (black). The ability to measure the molar mass distribution for the mixed sample, using the RI detector signal and the distribution of each individual polymer, is based on its spectral identity. Figure 5 Top image is an IR Transmission spectra of PS. The bottom image is an IR Transmission spectra of PMMA. Based on the spectra, the transition band at 701 cm -1 is selected for PS and the band at 1726 cm -1 is selected for PMMA. Figure 6 Top image is an overlaid plot of the injection of two narrow PS samples showing the intensity of the IR spectra at 701 cm -1 against the elution time of the separation (red) and the RI detector signal as a function of elution time (black). Bottom image is an overlaid plot of the injection of a narrow PS and a narrow PMMA sample showing the intensity of the PS IR spectra at 701 cm -1 against the elution time of the separation (red), the intensity of the PMMA infrared spectra at 1726 cm -1 against the elution time of the separation (green) and the RI detector signal as a function of elution time (black). 4

CONCLUSIONS Coupling the APC, high resolution / high speed SEC Core 1 System to the LC-T 700 is easily managed with the selection of the correct split ratio, tubing diameter, and sample scanning rates. The impact of the LC-T 700 on chromatographic band spread is minimal: approximately 20% increase in band spread. In the example studied, adding unique polymerspecific FTIR spectral identity to the SEC experiment offers the benefit of identification and qualification of individual polymers in a polymer mixture. The high speed chromatography offered by the ACQUITY APC System is a perfect match to the experimental conditions available with the LC-T 700 system enabling high resolution FTIR data References 1. Kritcheldorf, H R, Nuyken O, Swift G. Handbook of Polymer Synthesis. 2nd Ed. Taylor & Francis Ltd., Abingdon, UK, 2004. 2. Montaudo M S, Puglisi C, Samperi F, and Montaudo, G. Application of size exclusion chromatography matrix-assisted laser desorption/ionization time-offlight to the determination of molecular masses in polydisperse polymers. Rapid Commun Mass Spectrom. 12: 519 528, 1998. 3. Provder T, Urban M W, Barth H G. Hyphenated Techniques in Polymer Characterization, American Chemical Society, Washington, DC, 1994. 4. ACQUITY Advanced Polymer Chromatography System. Waters Corporation brochure no. 720004570en, November 2016, 5. LC-Transform Automated LC-IR Interface System, HTX Technologies, LLC, November 2016, https:// static1.squarespace.com/ static/5601aaeae4b0382c2e70e8bc/ t/56134c52e4b0b59b8352fdd3/1444105298326/lc- Transform+700+Brochure+07-14.pdf Waters, ACQUITY, Advanced Polymer Chromatography, Empower, and The Science of What s Possible are registered trademarks of Waters Corporation. APC is a trademark of Waters Corporation. All other trademarks are the property of their respective owners. 2016 Waters Corporation. Produced in the U.S.A. December 2016 PSTR134858001 JD-PDF 5