Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Similar documents
columns IonPac AS17-C Anion Exchange Column

columns IonPac AS22 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Dionex IonPac AS28-Fast-4µm column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column

anion-exchange column

columns IonPac AS18 Anion-Exchange Columns

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

columns IonPac SCS 1 Silica Cation Separator

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Sample Preparation for Ion Chromatography

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

suppressors Eluent Suppressors for Ion Chromatography

Thermo Scientific Dionex eluent suppressors for ion chromatography

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

suppressors SRS -ULTRA Self-Regenerating Suppressor

Determination of trace anions in concentrated hydrofluoric acid

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Overcoming Challenging Matrices in Ion Chromatography

High-Performance Chromatography Superior isocratic separation of

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Utility of the Charge Detector in Ion Chromatography Applications

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

IonPac Trace Cation Concentrator

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Determination of Trace Anions in Organic Solvents

for IonPac AG11-HC IonPac AS11-HC

groups I and II cations, amines, divalent transition metals

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Inline sample preparation for the determination of anions in sodium hydroxide

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

IC Columns Introduction

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Determination of Methylamine in Drug Products

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Expanded capabilities in ammonium and amine detection

Determination of urea in ultrapure water by IC-MS/MS

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

The determination of trace anions in concentrated phosphoric acid

Determination of trace anions in high-nitrate matrices by ion chromatography

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Product Manual for Dionex IonPac CS12A and CG12A Columns

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Theory of Ion Chromatography

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Determination of Adsorbable Organic Halogen in Wastewater

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

IonPac SCS 1 IonPac SCG 1

PRODUCT MANUAL. for the. IONPAC CG14 GUARD COLUMN (2 x 50 mm, P/N ) (4 x 50 mm, P/N )

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Trace Cations in Concentrated Acids Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Novel Electrodeionization Devices: Applications in Inorganic Analysis

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of Trace Anions in Concentrated Glycolic Acid

Determination of trace anions in concentrated glycolic acid

IC5000 Ion Chromatography System

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Transcription:

columns and Trap Columns IonPac AG, AS, mm Eluent Source: EG Temperature: C IonPac AC ( mm) Flow Rate:. m/min Eluent: Potassium hydroxide, Inj. Volume: m, preconcentrated mm from to min, mm mm from min to min, ASRS UTRA mm, AutoSuppression mm mm from to 8 min recycle mode Peaks:. Fluoride. µg/ (ppb). Acetate.. Formate.. Chloride.. Nitrite. 7 8 9. Carbonate 7. Sulfate. 8. Oxalate. 9. Bromide.. Nitrate.. Phosphate. IonPac and IonSwift concentrator columns for anion, cation, and chelation ion chromatography are used to concentrate analytes, allowing determinations at µg/ (ppb) and sub-µg/ levels. IonPac trap columns for anion and cation determinations prevent eluent contaminants from causing interfering peaks during gradient ion chromatography. Columns IonPac Columns are designed primarily for high-purity water analysis. The columns retain ions from a measured volume of aqueous sample matrix, thereby concentrating the analyte species and lowering detection limits. The advantage of using concentrator columns is the ability to perform routine analysis for ions at µg/ (ppb) to ng/ (ppt) levels. Figure illustrates a typical IC trace-enrichment system configuration using a concentrator column. The sample is pumped across the concentrator column, as shown in Figure A. After the analytes from the sample are concentrated, the valve is switched. The concentrated analytes are then swept by the eluent from the concentrator column onto the analytical column, as shown in Figure B. Figure illustrates the configuration of a D-IC System using a capillary concentrator column. The concentrator column is placed between the first and second dimension of the D System setup; a cut volume then is focused on the capillary concentration column, then eluted onto a second dimension column. Passion. Power. Productivity.

Figures illustrate the use of this system configuration for trace-level anion determinations. This concentrator system can also be used for the determination of trace cations and transition metals, as shown in Figures and. Ordering Information Monolith Anion (MAC-) A Sample Concentration Waste Column oad Eluent In Injection Valve (Rear-loading) To Analytical Column (. 8 mm) P/N 77 The MAC- Monolith Anion Column is designed primarily for high-purity water analysis. The MAC- is a general purpose, ultralow pressure anion concentrator designed for use with IonPac anion capillary columns and IonSwift anion columns. The MAC- strips ions from a measured volume of aqueous sample, concentrating the analyte species and thereby lowering detection limits. The MAC- is available in a. 8 mm format for ultralow pressure applications using a pressurized bottle, syringes, AS autosampler and a single piston sample delivery pump (AXP pump) for sample loading. The MAC- has a capacity of.7 μeq/ column and a void volume of approximately μ. Sample In B Sample Injection Sample to Waste Waste Column Inject Sample Eluent In Injection Valve (Rear-loading) To Analytical Column Figure. Process for ion chromatography trace enrichment: (A) sample concentration step and (B) sample injection step. Monolith Anion (MAC-) (.7 8 mm) P/N 7 A Waste W Auto- Sampler Detector CRD Waste W The MAC- Monolith Anion Column is designed primarily for D-IC capillary applications including trace bromate or perchlorate in drinking water matrices. The MAC- Column can also be used to preconcentrate trace anions in high purity water matrices. The MAC- is available in a.7 8 mm format designed specifically for concentrating trace anions such as bromate or perchlorate. The MAC- is placed between the first and second dimension of the D-IC system set-up and a cut volume is focused on the MAC-, then eluted onto a second dimension column such an IonPac AS9 or AS capillary column. The MAC- has a capacity of. μeq/column and a void volume of approximately μ. B Pump Pump Waste P C Sample oop S Suppressor mm Guard & Analytical Column Standard Bore: mm, m/min P C Sample oop W Auto- Sampler S Suppressor mm Guard & Analytical Column Standard Bore: mm, m/min Detector CRD Capillary Pump Figure. Configuration of a D-IC System using a capillary concentrator column. P P Capillary Pump C S Capillary Column. mm Guard & Analytical Column Capillary:. mm, µ/min Waste C W S Capillary Column. mm Guard & Analytical Column Capillary:. mm, µ/min Suppressor Detector Suppressor Detector 79

Anion s Anion Micro (AMC-) ( mm)...p/n 7 The AMC- is a low void-volume microconcentrator column designed for the concentration of inorganic and lowmolecular-weight organic anions from ultrapure water. The novel solvent compatible resin technology ensures a low sulfate background during the concentration step. The AMC- can be loaded with either a loop or sample loading pump. The low column void volume (approximately µ) allows improved determination of early-eluting anions such as fluoride, glycolate, acetate, and formate. This low void volume is ideal for mm concentration methods, reduces the system dip, and improves anion determinations for trace anion determinations in the power generation and semiconductor industries. The AMC- has a capacity of. µeq/ column and can be used in mm or mm i.d. anion-exchange systems with carbonate/bicarbonate or borate eluents. Trace Anion (TAC-P) ( mm)...p/n The TAC-P ow-pressure Trace Anion Column is designed primarily for high-purity water analysis. The TAC-P strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species and thereby lowering detection limits. The TAC-P is a general purpose, lowpressure concentrator for use with syringe or autosampler loading (AS-DV Autosampler). It can be used in anionexchange systems using hydroxide, carbonate/bicarbonate, or borate eluent systems. The TAC-P has a capacity of. µeq/column and a void volume of approximately µ. -. Figure. Separation of inorganic anions at trace concentrations on a IonPac AS9 capillary column with µ injection. Figure. Determination of trace concentrations of bromate using the IonPac AS column with two-dimensional ion chromatography.. A. First-Dimension Conditions IonPac AG9, AS9, mm Flow Rate:. m/min Eluent Source: EGC-KOH cartridge Eluent: mm KOH ( to min), mm KOH ( to min), and mm KOH ( to min) Detection: Suppressed conductivity SRS, mm Inj. Volume: µ Temperature:. C Deionized water Brand A bottled water ( ng/) ng/ bromate in deionized water ng/ bromate in deionized water -. 7 7 Bromate IonPac AS9 capillary column (. mm) Conc. IonSwift MAC- (. mm 8 mm) Eluent Source: Capillary EGC-KOH cartridge Eluent: mm KOH ( to min), to mm KOH ( to min), mm KOH ( to min), mm ( to min) Flow Rate: µ/min Temperature: C Suppressor: ACES Anion Capillary Electrolytic Suppressor Detection: Suppressed conductivity Injection Volume: µ Peaks: Concentration (µg/). Fluoride.. Chloride.. Nitrite.. Bromide.. Nitrate.. Sulfate. 7. Phosphate. B. Second-Dimension Conditions IonPac AS (. mm mm) Flow Rate: µ/min Eluent Source: Capillary EGC-KOH cartridge Eluent: 8 mm KOH ( to min), 8 to mm KOH ( to min), and 8 mm KOH ( to min) Detection: Suppressed conductivity, ACES anion capillary electrolytic suppressor Temperature: C IonSwift MAC- capillary concentrator, (.7 8 mm) µ of st dimension suppressed effluent (7. to min) Eluent: Flow Rate: Inj. Volume: Detection: IonPac AG, AS, mm IonPac TAC-P ( mm). mm Sodium carbonate/. mm Sodium bicarbonate. m/min m Suppressed conductivity Peaks:. Chloride 9.7 µg/ (ppb). Unidentified - ISO calibration data unavailable 79 79 8 9 Figure. Determination of trace-level chloride using a TAC-P concentrator column.

Ultra-ow-Pressure Trace Anion (TAC-UP) ( mm)... P/N The TAC-UP Ultra-ow-Pressure Trace Anion Column is designed primarily for high-purity water analysis. The TAC-UP strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species and thereby lowering detection limits. The TAC-UP is a general purpose, ultralow-pressure concentrator for use with syringe or autosampler loading (AS-DV and AS Autosamplers). The TAC-UP ( mm) can be used with singlepiston sample delivery pumps, including the AXP pump. The TAC-UP can be used with carbonate/bicarbonate, borate, or hydroxide eluents. The TAC-UP has a capacity of. µeq/column and a void volume of approximately µ. Ultratrace Anion ow Pressure (UTAC-Pl) ( mm)... P/N 79 The UTAC-P ( mm) Ultratrace Anion Column is designed primarily for high purity water analysis. The UTAC-P is an ultraclean (low sulfate) concentrator column. The UTAC-P strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species thereby lowering detection limits. The UTAC-P is a general purpose, low pressure anion concentrator column for use with syringe or autosampler loading (AS DV). The UTAC-P can be used with carbonate/bicarbonate, borate, or hydroxide eluents. The UTAC-P has a capacity of. µeq/column and a void volume of approximately µ... 7.. m Injection on UTAC-P Figure. Determination of trace anions using a TAC-UP concentrator column. µ Direct Injection 7 8. 7. 7 9 8 8 9 9 7 IonPac AG8, AS8 mm Conc. IonPac TAC-UP ( mm) Eluent: mm Potassium hydroxide Source: EGC-KOH Temperature: C Flow Rate:. m/min Inj. Volume: m ASRS UTRA, mm, AutoSuppression recycle mode Peaks:. Fluoride. µg/ (ppm). Acetate.. Formate.. Chlorite.. Chloride.. Nitrite. 7. Carbonate. 8. Bromide. 9. Sulfate.. Nitrate.. Chlorate. 9 IonPac AG8, AS8, mm Conc. IonPac UTAC-P ( mm) Eluent: mm Potassium hydroxide Eluent Source: EGC II KOH cartridge with CR-ATC Flow Rate:. m/min Inj. Volume: See chromatogram Temperature: C ASRS UTRA II mm, AutoSuppression recycle mode Peaks:. Fluoride. mg/ (ppm). Acetate.. Formate.. Chlorite.. Chloride.. Nitrite. 7. Carbonate. 8. Bromide. 9. Sulfate.. Nitrate.. Chlorate. Figure 7. Comparison of direct injection and preconcentration using the UTAC-P concentrator column for the determination of trace anions. IonPac AGA, ASA, mm Conc. IonPac TAC- ( mm) Eluent:.7 mm Sodium bicarbonate/. mm Sodium carbonate Flow Rate:. m/min Inj. Volume: 8 m, preconcentrated ASRS UTRA mm, AutoSuppression external water mode Peaks:. Fluoride. µg/ (ppb). Chloride.. Nitrite.. Bromide.. Nitrate.. Phosphate. 7. Sulfate. 7 8 Figure 8. Trace-level anion determination using a TAC- concentrator column.

Ultratrace Anion ow Pressure (UTAC-P) ( mm)...p/n 7779 The UTAC-P ( mm) Ultratrace Anion Column is designed primarily for high-purity water analysis. The UTAC-P is a general purpose, low-pressure anion concentrator column with similar features to the UTAC-P, but backpressure resilience has been improved to eliminate the need for a pulse damper on the loading pump, and matrix resilience has been improved to allow direct injection of samples containing polyacrylic acid additives used in the power industry. The UTAC-P is available in a mm format for low-pressure applications including loading pump, syringe or AS-DV autosampler loading. The UTAC-P has a capacity of. µeq/column and a void volume of approximately µ. Ultratrace Anion -Ultra ow Pressure (UTAC-UPl) ( mm)... P/N 7 The UTAC-UP ( mm) Ultratrace Anion Column is designed primarily for high purity water analysis. The UTAC-UP is an ultra clean (low sulfate) concentrator column. The UTAC-UP strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species thereby lowering detection limits. The UTAC-UP is a general purpose, ultra low-pressure concentrator for use with syringe or autosampler loading (AS-DV and AS Autosamplers). The UTAC UP can be used with single piston sample delivery pumps including the AXP pump. The UTAC UP can be used with carbonate/ bicarbonate, borate, or hydroxide eluents. The UTAC-UP has a capacity of. µeq/column and a void volume of approximately µ. Eluent: Eluent Source: EG Temperature: C IonPac AG, AS, mm IonPac AC ( mm) Potassium hydroxide, mm from to min, mm to mm from min to min, mm to mm from to 8 min 7 8 9 Flow Rate:. m/min Inj. Volume: m, preconcentrated ASRS UTRA mm, AutoSuppression recycle mode Peaks:. Fluoride. µg/ (ppb). Acetate.. Formate.. Chloride.. Nitrite.. Carbonate 7. Sulfate. 8. Oxalate. 9. Bromide.. Nitrate.. Phosphate. Figure 9. Determination of inorganic anions and low molecular weight organic acids with sample preconcentration using a mm AC column. IonPac AS, mm Eluent: mm Sodium hydroxide Flow Rate:. m/min Sample: m concentrated on AC column, rinsed with DI water at. m/min for min ASRS-UTRA mm, AutoSuppression external water mode Peaks:. Carbonate µg/ (ppb). Chloride.. Sulfate <.. Unknown Figure. Determination of anions in semiconductor-grade isopropyl alcohol using an AC concentrator column... Bromate -..... 8.. 9 87 8 IonPac AG, AS, mm Conc. IonPac AC-ER ( mm) Eluent:. mm Sodium carbonate/.8 mm Sodium bicarbonate Flow Rate: m/min Inj. Volume: µ, preconcentrated ASRS, mm, AutoSuppression recycle mode Peaks:. Bromate Figure. Determination of bromate in a municipal water sample using a Reagent-Free IC system with eluent regeneration and an AC-ER concentrator column.

Ultratrace Anion Ultra ow Pressure (UTAC-P) ( mm)...p/n 778 The UTAC-UP ( mm) Ultratrace Anion Column is designed primarily for high-purity water analysis. The UTAC-UP is a general purpose, ultralow pressure anion concentrator column with similar features to the UTAC-UP, but backpressure resilience has been improved to eliminate the need for a pulse damper on the loading pump, and matrix resilience has been improved to allow direct injection of samples containing polyacrylic acid additives. UTAC-UP is available in a mm formnat for ultralow pressure applications including loading pump, syringe, and AS-DV or AS autosampler loading. The UTAC UP has a capacity of. µeq/column and a void volume of approximately µ. Ultratrace Anion -Extremely ow Pressure (UTAC-XPl) ( mm)... P/N 9 The UTAC-XP ( mm) Ultratrace Anion Column is designed primarily for high purity water analysis. The UTAC-XP is an ultraclean (low sulfate) concentrator column. The UTAC-XP strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species thereby lowering detection limits. The UTAC-XP is a general purpose, extremely low-pressure concentrator for use with syringe or autosampler loading (AS-DV and AS Autosamplers). The UTAC-XP can be used with single piston sample delivery pumps including the AXP pump. The UTAC-XP can be used with carbonate/bicarbonate, borate, or hydroxide eluents. The UTAC-XP has a capacity of. µeq/column and a void volume of approximately µ.. Figure. Separation of inorganic cations at trace concentrations using an IonPac CS capillary column and IonSwift MCC- concentrator column with µ injection.. IonPac CSA, mm Eluent: mn Sulfuric acid Flow Rate:. m/min Inj. Volume: m, preconcentrated CSRS UTRA mm, AutoSuppression external water mode Peaks:. Sodium < ng/ (ppt). Ammonium <. Trimethylamine ISO calibration data unavailable. Figure. Determination of trace cations using sample preconcentration.. IonPac CGA, CSA, mm IonPac TCC- Eluent: MetPac PDCA Flow Rate:. m/min AU Eluent Source: Eluent: IonPac CS (. mm mm) Capillary EGC-MSA cartridge mm MSA -. 7 8 8 Flow Rate: µ/min Temperature: C Suppressor: CCES Cation Capillary Electrolytic Suppressor Detection: Suppressed conductivity : IonSwift MCC- (. mm 8 mm) Inj. Volume: µ Sample Deionized water spiked with six cations Peaks: Postcolumn Reagent:. ithium.7 µg/. Sodium.7. Ammonium.8. Potassium.7. Magnesium.7. Calcium.7 PAR in MetPac Postcolumn reagent diluent Figure. Determination of trace transition metals using sample preconcentration. 8 PCR Flow Rate:. m/min Detection: nm, mm cell Column Temp: C Inj. Volume:. m, preconcentrated Peaks:. Iron ng/(ppt). Copper. Nickel. Zinc >. Cobalt. Cadmium 7. Manganese 7 8. Iron Note: Zn contamination present 8 77 Ultratrace Anion Extremely ow Pressure (UTAC-P) ( mm)...p/n 778

The UTAC-XP ( mm) Ultratrace Anion Column is designed primarily for high purity water analysis. The UTAC-XP is a general purpose, extremely low-pressure anion concentrator column with similar features to the UTAC-XP, but backpressure resilience has been improved to eliminate the need for a pulse damper on the loading pump, and matrix resilience has been improved to allow direct injection of samples containing polyacrylic acid additives used in the power industry. The UTAC-XP is available in a mm format for extremely low-pressure applications including AS-DV and AS autosampler loading. The UTAC-UP has a capacity of. µeq/column and a void volume of approximately µ. Trace Anion (TAC-) ( mm)...p/n (pkg. of )...P/N The TAC- is a pellicular anionexchange concentrator column with a capacity of. µeq/column and a moderately low void volume (approximately µ). The TAC- can be used in anion-exchange systems using carbonate/bicarbonate or borate eluent systems. Note that the TAC- should not be used with solvents. IonPac AC ( mm)...p/n For use with IonPac AS mm anion-exchange columns; The AC has a void volume of approximately 7 µ and a capacity of approximately µeq/column. IonPac AC ( mm)...p/n For use with IonPac AS mm anion-exchange columns; the capacity is approximately.8 µeq/column. The void volume is approximately µ. IonPac AC ( mm)...p/n 9 For use with IonPac AS mm anion-exchange columns; the capacity is approximately 9 µeq/column. The void volume is approximately µ. IonPac AC ( mm)...p/n 9 For use with IonPac AS mm and mm anion-exchange columns; the capacity is approximately. µeq/column. The void volume is approximately µ. IonPac Anion for Eluent Regeneration (AC-ER) ( mm)...p/n 7778 The AC-ER ( mm) Anion Column is a general purpose, low-dead volume, extremely low pressure anion concentrator column with similar features to the UTAC concentrators, but with reduced dead volume and capacity. The AC-ER is available in a mm format for very low-dead volume to maximize the number of injections that can be made on an RFIC system with eluent regeneration (ER) between eluent exchanges. The AC-ER has a capacity of. µeq/ column and a void volume of approximately 7 µ. With an AC-ER column installed in an RFIC-ER system, each injection only adds 7 μ of sample matrix into the eluent regardless of the sample volume (7 µ + µ for connecting tubing). Therefore, approximately injections can be performed before the eluent needs to be replaced, regardless of the actual amount of sample loaded onto the concentrator. And by using a matrix elimination step with the AC-ER in place, solvents can be directly injected onto the AC-ER then flushed off before injection into the RFIC-ER system. The new AC-ER concentrator brings a host of new applications within range of RFIC-ER systems, including analysis of bromate to ppb in drinking water, and analysis of common anions in ethanol. Cation s Monolith Cation (MCC-) (. 8 mm) P/N 7 The MCC- Monolith Cation Column is designed primarily for high-purity water analysis. The MCC- is a general purpose, ultralow pressure Cation concentrator designed for use with IonPac cation capillary columns. The MCC- strips ions from a measured volume of aqueous sample, concentrating the analyte species and thereby lowering detection limits. The MCC- is available in a. 8 mm format for ultralow pressure applications using a pressurized bottle, syringes, AS autosampler and a single piston sample delivery pump (AXP pump) for sample loading. The MCC- has a capacity of.7 μeq/ column and a void volume of approximately μ. Monolith Cation (MCC-) (.7 8 mm) P/N 7 The MAC- Monolith Cation Column is designed primarily for D-IC capillary applications including trace ammonium and amines in high salt matrices. The MCC- Column can also be used to preconcentrate trace cations in high purity water matrices. The MCC- is available in a.7 8 mm format designed specifically for concentrating trace cations such as ammonium or amines. The MCC- is placed between the first and second dimension of the D-IC system set-up and a cut volume is focused on the MCC-, then eluted onto a second dimension column such an IonPac CS or CS7 capillary column. The MCC- has a capacity of.7 μeq/column and a void volume of approximately μ. 7

Trace Cation (TCC-P) ( mm)...p/n 7 The TCC-P ( mm) ow Pressure Trace Cation Column is designed primarily for high purity water analysis. The TCC-P strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species thereby lowering detection limits. The TCC-P is a general purpose, low-pressure concentrator for use with syringe or autosampler loading (AS DV). It is designed for use with carboxylated cation-exchange systems such as the Ion- Pac CS, CSA, CS, CS, CS, CS7 or CS8 with monovalent eluents (sulfuric acid, methanesulfonic acid, or hydrochloric acid). The TCC-PI has a capacity of µeq/column and a void volume of approximately µ. Without polishing sample After polishing sample with CP.. 8.. Flow Rate: Eluent: Suppressor: Concentration Volume: Sample: IonPac AGA, ASA, mm. m/min EG Gradient with mm Boric acid Time (min) Concentration (KOH, mm)... ASRS UTRA II, mm ma IonPac AGA m Concentration (µg/). Fluoride Carbonate. Chloride. Sulfate Boron mg/ i. Figure. This example compares a simulated borated water sample consisting of trace anions and lithium. The polishing step ensured complete recovery of both response and peak shapes for all ions. Cation Polisher CP is placed between the sampling pump and the injection valve. Ultralow Pressure Trace Cation (TCC-UPl) ( mm)... P/N 78 The TCC-UP ( mm) Ultralow Pressure Trace Cation Column is designed primarily for high purity water analysis. The TCC-UP strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species thereby lowering detection limits. The TCC-UP is a general purpose, ultralow-pressure concentrator for use with syringe or autosampler loading (AS-DV or AS Autosamplers). The TCC-UP can also be used with single-piston sample delivery pumps including the AXP pump. It is recommended for use with carboxylated columns such as the IonPac CS, CSA, CS, CS, CS, CS7 and CS8 columns. The TCC-UP can be used with sulfuric acid, methanesulfonic acid, and hydrochloric acid eluents. The TCC-UP has a capacity of µeq/column and a void volume of approximately µ. Extremely ow Pressure Trace Cation (TCC-XPl) ( mm)... P/N 889 The TCC-XP ( mm) Extremely ow Pressure Trace Cation Column is designed primarily for high purity water analysis. The TCC-XP strips ions from a measured volume of aqueous sample matrix, concentrating the analyte species thereby lowering detection limits. The TCC- XP is a general purpose, extremely low-pressure concentrator for use with syringe or autosampler loading (AS-DV or AS Autosamplers). The TCC-XP can also be used with single-piston sample delivery pumps including the AXP pump. It is recommended for use with carboxylated columns such as the CS, CSA, CS, CS, CS, CS7 and CS8 columns. The TCC-XP can be used with sulfuric acid, methanesulfonic acid, and hydrochloric acid eluents. The TCC-XP has a capacity of µeq/ column and a void volume of approximately µ. Trace Cation (TCC-) ( mm)...p/n (pkg. of )...P/N The TCC- is a surface-sulfonated cation-exchange concentrator column with a capacity of approximately µeq/column and a low void volume of approximately µ. It is ideal for use with sulfonated cation-exchange columns such as the IonPac CS, CS, and CS. The TCC- can also be used as concentrator column for transition metals. Chelation Ion Chromatography s MetPac CC- ( mm) (pkg. of )... P/N A chelating column ideal for concentration of cationic transition metals from high ionic strength matrices. The capacity is. meq/column. TMC- ( mm)... P/N 9 A high-capacity cation-concentration column used for coupling the MetPac CC- to the IonPac CS or IonPac CSA analytical columns when performing chelation IC. The capacity is. meq/column. 8

Trap Columns IonPac Trap columns contain highcapacity, low-efficiency, ion-exchange resin. The column strips trace contaminants from the eluent, preventing concentration on the guard and analytical columns. The trap column is installed in the eluent line prior to the injection valve to prevent spurious peaks during gradient chromatography. Metal-Free Trap Column Metal-Free Column (MFC-) ( 7 mm)... P/N 77 The MFC- is packed with a special chelating resin and is used in the eluent line prior to the injection valve to remove transition metals from high-ph eluents. The capacity is 7 µeq/column. Continuously Regenerated Trap Columns (CR-TC) CR-TC trap columns are highpressure, electrolytically regenerated devices that remove ionic contaminants from the eluent without the need for off-line chemical regeneration. The product is available in two versions, the CR-ATC for anion applications and CR-CTC II for cation applications. The CR-TC is compatible with all Dionex Eluent Generators including the RFC-, ICS- and ICS- EG. EG customers must first order the CR-TC Add-on Kit (P/N 7). A single format is used with,,, and mm i.d. separator column applications, while a second format is available for capillary column applications. CR-ATC Continuously Regenerated Anion Trap Column... P/N 77 CR-ATC (Capillary)... P/N 778 When plumbed after the EluGen cartridge, the CR-ATC removes all anionic contaminants, for example carbonate, from the deionized feed water and provides low drift during gradient operations. CR-CTC II Continuously Regenerated Cation Trap Column...P/N CR-CTC (Capillary)... P/N 779 When plumbed after the EluGen cartridge, the CR-CTC removes cationic contaminants, for example ammonium and sodium, from deionized feed water and provides low drift during gradient operations. Anion Trap Columns The ATC is a high-capacity anionexchange column used to remove trace anion contamination from eluents. ATC- (9 mm)... P/N 9 For use with mm anion-exchange columns. ATC- ( mm)... P/N 9 For use with mm and mm anion-exchange columns. ATC-HC (9 7 mm)... P/N 9 For use with the EGC-KOH, EGC-NaOH, EGC-iOH or EGC-K CO cartridges in the EG or EG Eluent Generator. ATC-HC Borate Form (9 7 mm)... P/N 7 For use with the EG generated borate eluents or with manually prepared borate eluents. Cation Trap Columns The CTC is a high-capacity cationexchange column packed with sulfonated resin. The CTC is used to remove trace cation contamination from the eluent. CTC- (9 mm)... P/N 9 For use with mm and mm cationexchange columns. CTC ( mm) ( mm)... P/N For use with mm and mm cation-exchange columns. Cation Polisher Columns Cation Polisher CP and CP columns are designed for removal of metallic contaminants and other cations such as calcium and magnesium from the sample stream while performing anion analysis. The columns improve the performance of ion chromatography systems, particularly with phosphate analysis in the presence of metallic contaminants. Samples that contain high levels of metals or cations can be deposited on the guard/analytical columns or the suppressor, which can lead to performance issues such as poor peak shapes or poor recoveries for some anions such as phosphate. These contaminants can adversely affect the operation of the guard/analytical columns or suppressor. Cation Polisher columns address the potential precipitation issue of these contaminants and aid in extending the column and suppressor lifetimes when pursuing anion analysis and when the matrix ions contain multivalent cations. In some cases the Cation Polisher columns aid removal of matrix cations when pursuing anion analysis with sample preconcentration. The matrix cations can elute species of interest from the concentrator column and lead to poor peak shapes and recovery. Removing the matrix cations using Cation Polisher columns helps ensure good chromatographic performance. The CP ( mm) column is a cation-exchange column in the sodium form and packed in a low pressure format and is specifically designed for autosampler operation. The void volume of this column is approximately µ. The CP (9 mm) column is a higher capacity version in the hydronium form and has a void volume of approximately 8 µ. The CP Polisher Column is recommended for large volume sample preconcentration applications using an external pump. Both columns can be regenerated offline approximately every months (depending on the level of contamination and usage). Cation Polisher CP Na + Form ( mm)... P/N 9 Cation Polisher CP H + Form (9 mm)...p/n 9 9

* AXP pumps should use a pressurized sample source. Column Selection Table Column Capacity Void Volume Recommended Recommended Sample (µeq/column) (µ) Applications Delivery Method Anion MAC-.7 Hydroxide, carbonate/bicarbonate Pressurized bottle, syringes, AS autosampler, and single piston sample delivery pump (AXP pump) MAC-. Hydroxide, carbonate/bicarbonate Pressurized bottle, syringes, AS autosampler, and single piston sample delivery pump (AXP pump) AMC-.. Carbonate/bicarbonate and AXP pump* borate eluents TAC-P.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, low-pressure autosamplers (AS-DV), SP AutoNeutralization Module TAC-UP.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, autosamplers (AS-DV and AS) single-piston sample delivery pumps (AXP pump). UTAC-P.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, lowpressure autosamplers (AS-DV and AS-HV) UTAC-P.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, lowand borate eluents pressure autosamplers (AS-DV and AS-HV) UTAC-UP.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, autosamplers (AS-DV and AS and AS-HV), single-piston sample delivery pumps (AXP pump) UTAC-UP.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, autosamplers (AS-DV and AS and AS-HV), single-piston sample delivery pumps (AXP pump) UTAC-XP.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, lowand borate eluents pressure autosamplers (AS-DV, AS and AS-HV), single piston delivery pumps (AXP pump) UTAC-XP.. Hydroxide, carbonate/bicarbonate Pressurized bottles, syringes, low pressure autosamplers (AS-DV, AS and AS-HV) single-piston delivery pumps (AXP pump) TAC-.. Carbonate/bicarbonate and AXP pump* AC ( mm). 7. Hydroxide AXP pump* AC ( mm).8. Hydroxide AXP pump* AC ( mm) 9.. Hydroxide AXP pump* AC ( mm).. Hydroxide AXP pump* AC-ER. 7 Carbonate/bicarbonate eluent with Syringes, low-pressure RFIC-ER systems autosamplers (AS-DV and AS)

* AXP pumps should use a pressurized sample source. Column Selection Table Column Capacity Void Volume Recommended Recommended Sample (µeq/column) (µ) Applications Delivery Method Cation MCC-.7 Use with carboxylated columns; Pressurized bottle, syringes, MSA and sulfuric acid eluents AS autosampler, and single piston sample delivery pump (AXP pump) MCC-.7 Use with carboxylated columns; Pressurized bottle, syringes, MSA and sulfuric acid eluents AS autosampler, and single piston sample delivery pump (AXP pump) TCC-P.. Use with carboxylated columns; Pressurized bottles, syringes, MSA and sulfuric acid eluents low-pressure autosamplers, (AS-DV) SP AutoNeutralization Module TCC-UP.. Use with carboxylated columns; Pressurized bottles, syringes, MSA and sulfuric acid eluents autosamplers (AS-DV and AS Autosamplers), single-piston sample deliver pumps (AXP pump). TCC-XP.. Use with carboxylated columns; Pressurized bottles, syringes, MSA and sulfuric acid eluents autosamplers (AS-DV and AS Auotsamplers), single-piston sample deliver pumps AXP pump). TCC-.. Use with sulfonated columns; AXP pump* HCl/DAP HCl eluents

a Surface-functionalized resin. b Fully-functionalized resin. and Trap Column Specifications Column Particle Substrate atex atex Capacity Functional Group Hydrophobicity Diameter X-linking Diameter X-linking (per column) MAC- Monolithic % 8 nm %.7 µeq Alkanol quaternary ammonium Very low backbone MAC- Monolithic % 8 nm %. µeq Alkanol quaternary ammonium Very low backbone AMC- µm % Nonea NA. µeq Alkyl quaternary ammonium Medium TAC-P 8 µm % 8 nm %. µeq Alkanol quaternary ammonium Very low TAC-UP 8 µm % 8 nm %. µeq Alkanol quaternary ammonium Very low UTAC-P 7 µm % 8 nm % µeq Alkanol quaternary ammonium Very low UTAC-P µm % N/A N/A µeq Alkanol quaternary ammonium Very low UTAC-UP 7 µm % 8 nm % µeq Alkanol quaternary ammonium Very low UTAC-UP µm % N/A N/A µeq Alkanol quaternary ammonium Very low UTAC-XP 7 µm % 8 nm % µeq Alkanol quaternary ammonium Very low UTAC-XP µm % N/A N/A µeq Alkanol quaternary ammonium Very low TAC- µm % nm %. µeq Alkyl quaternary ammonium Medium AC ( mm) µm % nm %. µeq Alkanol quaternary ammonium ow AC ( mm) µm % nm %.8 µeq Alkanol quaternary ammonium ow AC ( mm) µm % 8 nm % 9. µeq Alkanol quaternary ammonium Very low AC ( mm) µm % 8 nm %. µeq Alkanol quaternary ammonium Very low AC-ER µm % N/A N/A µeq Alkanol quaternary ammonium Very low AC ( mm) µm % 8 nm %. µeq Alkanol quaternary ammonium Very low MCC- Monolithic % 8 nm %.7 µeq Fully functionalized Very low backbone with carboxylic acid MCC- Monolithic % 8 nm %. µeq Fully functionalized Very low backbone with carboxylic acid TCC-P µm % None a NA. µeq Fully functionalized Very low with carboxylic acid TCC-UP µm % None a NA. µeq Fully functionalized Very low with carboxylic acid TCC-XP µm % None a NA. µeq Fully functionalized Very ow with carboxylic acid TCC- µm % None a NA. µeq Sulfonic acid High

a Surface-functionalized resin. b Fully-functionalized resin. and Trap Column Specifications Column Particle Substrate atex atex Capacity Functional Group Hydrophobicity Diameter X-linking Diameter X-linking (per column) Trap ATC- ( mm) µm 8% None b NA. meq Quaternary ammonium ow ATC- ( mm) µm 8% None b NA. meq Quaternary ammonium ow ATC-HC (9 7 mm) 7 µm 8% None b NA. meq Quaternary ammonium ow ATC-HC Borate Form 7 µm 8% None b NA. meq Quaternary ammonium ow (9 7 mm) CTC ( mm) µm 8% None b NA. meq Sulfonic acid ow CTC ( mm) µm 8% None b NA.8 meq Sulfonic acid ow MFC- µm % None b NA 7. µeq Iminodiacetate Medium Transition Metal MetPac CC- 8 µm % None b NA. meq Iminodiacetate Medium TMC- 7 µm 8% None b NA. meq Sulfonic acid Medium Cation Polisher CP Na + Form µm % None b NA 7. meq Carboxylic acid Very low ( mm) CP H + Form µm % None b NA 7. meq Carboxylic acid Very low (9 mm) ASRS, AutoSuppression, CSRS, and IonPac are registered trademarks, and ACES, AutoNeutralization, CCES, IonSwift, MetPac, and Reagent-Free are trademarks of Dionex Corporation. Passion. Power. Productivity. Dionex Corporation north America Europe Asia Pacific 8 Titan Way U.S./Canada (87) 9-7 Austria () Benelux () 8 978; () 9 Australia () 9 China (8) 8 8 India (9) 7 7 P.O. Box Denmark () 9 9 France () 9 Germany (9) 99 Japan (8) 88 Korea (8) 8 Singapore () 89 9 South America Sunnyvale, CA Ireland () Italy (9) 7 Sweden () 8 7 8 Taiwan (88) 87 Brazil () 7 PN 9- PDF / 988- Switzerland () 99 United Kingdom () 7 97 Dionex Corporation (8) 77-7 www.dionex.com