Leave Your Footprint!

Similar documents
Gemini-NX Performance paired with Axia Technology

Your Reversed Phase Method

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

LC and LC/MS Column Selection Flow Chart

Reversed Phase Solvents

LC Technical Information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

penta-hilic UHPLC COLUMNS

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Method Development Kits

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

It s hot! ZIC -chilic

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

[ Care and Use Manual ]

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Analysis - HPLC A.136. Primesep 5 µm columns B.136

penta-hilic UHPLC COLUMNS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

for Acclaim Mixed-Mode HILIC-1 Column

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Too Polar for Reversed Phase What Do You Do?

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Strategies for the Flash Purification of Highly Polar Compounds

Part 2. Overview of HPLC Media

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Cation Exchange HPLC Columns

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

mau 200 ph min

Setting the Standard for ph Method Development

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Definitive EtG/EtS LC-MS/MS Analysis:

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

1.7 m Fortis UHPLC Columns

Successfully Scaling and Transferring HPLC and UPLC Methods

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Setting the Standard for ph Method Development

Alltech Alltima HP Introduction

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Packings for HPLC. Packings for HPLC

Shodex TM ODP2 HP series columns

Open Column Chromatography, GC, TLC, and HPLC

ChromegaChiral TM CSP Media and Columns

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

C18 Column. Care & Use Sheet

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Acclaim HILIC-10 Columns

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HILIC Method Development in a Few Simple Steps

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

Comparison of different aqueous mobile phase HPLC techniques

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Acclaim Mixed-Mode WAX-1 Columns

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Multi-mode Separations Using Zirconiabased Stationary Phases

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

columns IonPac AS17-C Anion Exchange Column

The Standard for ph Method Development

for Acclaim Mixed-Mode WCX-1

Do you need trouble-free speed? The NEW Chromolith HR

Chemistry Instrumental Analysis Lecture 28. Chem 4631

The Theory of HPLC. Ion Pair Chromatography

ProPac WCX-10 Columns

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

ChromegaChiral TM CSP Media and Columns

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

High Performance Liquid Chromatography

High Performance Liquid Chromatography

LC Columns with Liquid Separation Cell Technology

Optical Isomer Separation Columns and Packing Materials

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Transcription:

Leave Your Footprint! Luna HILIC Luna HILIC columns retain a water-enriched layer on the surface of the silica. This water layer facilitates the transfer of polar compounds into the stationary phase for increased retention. Separation is achieved through the partitioning of polar solutes from the high concentration, water-miscible, organic mobile phase into the hydrophilic surface environment. Polar solutes exhibit increased retention, and elute in the order of increasing hydrophilicity. The Luna Legacy EW Luna C8 Luna C8() Luna C8 Luna C8() Luna C5 Luna Phenyl-Hexyl Luna C Luna H Luna SCX Luna Silica() Luna HILIC Luna HILIC lives up to the exacting standards of quality and customer satisfaction that has been exemplified in the 0 years of the Luna line.

Table f Contents Benefits of HILIC Chromatography Luna HILIC delivers Superior retention of polar compounds Increased mass spec sensitivity Increased laboratory throughput and productivity Finally, reproducible, robust HILIC separations Polar Compound Retention~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Page - Improved Mass Spec Sensitivity~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Page -5 Increased Sample Throughput~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Page 6-7 Benefits of Luna HILIC Stability~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~Page 8 Reproducibility~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~Page 9 Low MS-Bleed~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~Page 9 Selectivity Advantages~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~Page 0 HILIC Method Development Strategy Step-by-Step Approach~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~Page rdering Information~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~Page 6

Benefits of HILIC Chromatography Polar Compound Retention Polar Compounds on Luna HILIC A note on analyte retention and solubility characteristics in HPLC: An analyte must, to some degree, be soluble in or have an affinity for, both the column stationary phase and the mobile phase. This principle is illustrated in the General Chromatographic Performance equation as retention factor or (k), a measure of the degree to which the compound is retained by the column. This critical parameter may be optimized to influence the overall chromatographic separation. R = - k s k+ Although the majority of HPLC separations today are performed under reversed phase conditions using hydrophobic stationary phases (for example, C8, C8, and Phenyl), hydrophilic (polar) compounds do not retain well under reversed phase conditions. The stagnant organic solvent present near the hydrophobic stationary phase is not conducive for interaction with the polar compounds; as a result these compounds are not well retained. They may elute near the void volume making quantitation difficult. Luna HILIC allows increased retention of polar compounds in a highly organic mobile phase. The functionalized silica surface draws and retains water on the surface of the silica. This stagnant water-enriched layer facilitates the transfer of polar compounds into the stationary phase where analyte retention occurs. Under HILIC conditions, the more polar compounds will have a stronger interaction with this polar stationary phase and the retention factors for these compounds will increase. Request the Technical ote! With HILIC mode techniques, polar compounds receive the highest degree of retention! As such, Luna HILIC will retain the polar compounds that elute near the void in reversed phase chromatography. To effectively illustrate the competencies of HILIC mode chromatography, we have selected nine water-soluble vitamins, demonstrating diverse chemistry and selectivity, for use as probes. Wide Variety of Functionalities and pk a s Carboxylic Acids (pk a.7.7) Amines (pk a. 5.6) Phosphate (pk a.5) Quaternary Amine (pk a 5.5) App ID 60 Vitamin Mix on Luna HILIC 0 to 5 6 7 6 8 0 Column: Luna 5 µm HILIC Dimension: 50 x.6 mm Part o.: 00F-50-E0 Mobile Phase: A: Acetonitrile B: Water C: 00 mm Ammonium Acetate, ph 5.8 Gradient: A/B/C (90:5:5) for.5 min to A/B/C (50:5:5) in 7.5 min, hold for.5 min. Re-equilibrate @ A/B/C (90:5:5) for 7.5 min. Flow Rate:.0 ml/min Detection: UV @ 60 nm Sample:. p-aminobenzoic Acid pk a.7, H + pk a.7 logp 0.8. icotinamide H + pk a.5 logp 0.7. Riboflavin pk a 0. logp.6. icotinic Acid pk a.7, H+pK a.0 logp 0.6 5. Pyridoxine H + pk a 5.6, pka 8.6 logp 0.77 6. Thiamine H + pk a 5.5 logp.6 7. Ascorbic Acid pk a.,. logp.85 8. Cyanocobalamin pk a.59 logp 0.90 9. Folic Acid pk a.7,., 8.9 logp 0.0 Wide logp Range (5. Units) Minimum logp =.6 (Thiamine) Maximum logp = 0.8 (p-aminobenzoic Acid) 8 9 Why Vitamins? min Vitamins provide an ideal platform to demonstrate the benefits of HILIC chromatography. The chosen vitamins used in our testing incorporate the following: Broad range of pk a values Variety of functional groups Wide logp range (5. units) The effect of increased polar compound retention can be easily seen through this group of vitamins.

Benefits of HILIC Chromatography Polar Compound Retention App ID 6 App ID 6 Ribavirin on Luna HILIC Increased retention and sensitivity Peak area = 0,759 0 0. 0. 0.6 0.8.0...6.8.0...6.8.0 min Ribavirin on C8 k = 0.85 Requires gradient to elute Elutes at void Peak area = 7,996 0 0. 0. 0.6 0.8.0...6.8.0...6.8.0 min Ribavirin H H H 0.5 ng on column Column: Luna µm HILIC Dimension: 00 x.0 mm Part o.: 00D-9-B0 Mobile Phase: A: Acetonitrile/00 mm Ammonium Formate, ph. (90:0) B: Acetonitrile/0 mm Ammonium Formate, ph. (50:50) Gradient: 00 % A for min, then 00 % B to.5 min, switch to 00 % A for 0 min Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Sample:. Ribavirin (MRM: 5./.) 0.5 ng on column Column: Gemini 5 µm C8 Dimension: 00 x.0 mm Part o.: 00D-5-B0 Mobile Phase: Acetonitrile with 0. % v/v Formic Acid/Water with 0. v/v % Formic Acid (:97) Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) (ambient) Sample:. Ribavirin (MRM: 5./.) H Highly polar compounds such as Ribavirin may be poorly retained on reversed phase columns HILIC techniques will increase polar compound retention and sensitivity App ID 60 App ID 6 Because HILIC uses a solvent system that is the reverse of what is common in reversed phase, the peak elution order is reversed on Luna HILIC. Polar/ Hydrophilic compounds that are particularly difficult to retain even on polarembedded reversed phase columns will enjoy maximum retention on HILIC. Ganciclovir & Acyclovir on Luna HILIC.e.0e.9e.8e.7e.6e.5e.e.e.e.e.0e 9000.0 8000.0 7000.0 6000.0 5000.0 000.0 000.0 000.0 000.0 0.0.e.0e.9e.8e.7e.6e.5e.e.e.e.e.0e 9000.0 8000.0 7000.0 6000.0 5000.0 000.0 000.0 000.0 000.0 0.0 More Polar Compound = More Retention!. Acyclovir = red. Ganciclovir = blue 0. 0. 0.6 0.8.0...6.8.0...6.8 min Ganciclovir & Acyclovir on Polar-Embedded C8 0. 0. 0.6 0.8.0...6.8.0...6.8 min Column: Luna µm HILIC Dimension: 00 x.0 mm Part o.: 00D-9-B0 Mobile Phase: Acetonitrile/00 mm Ammonium Formate, ph. (90:0) Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Sample:. Acyclovir. Ganciclovir. Acyclovir = red. Ganciclovir = blue Column: Synergi µm Fusion-RP 80 Å Dimension: 00 x.0 mm Part o.: 00D--B0 Mobile Phase: Acetonitrile/0 mm Ammonium Formate, ph. (:97) Flow Rate: 0. ml/min Detection: UV @ 60 nm Sample:. Acyclovir. Ganciclovir

Benefits of HILIC Chromatography Improved Mass Spec Sensitivity The increased retention in HILIC allows elution of the analytes outside the suppression region and thus increased detector sensitivity. In addition to the increased retention and sensitivity, HILIC also resolved the compounds with the reverse order of that seen in RPLC. Elution reversal in HILIC can be a benefit when interferences are observed in RPLC. Increased Sensitivity in LC-MS/MS with Luna HILIC The analysis of bioanalytical samples in support of clinical and preclinical pharmacokinetic studies requires a highly sensitive analytical methodology, capable of achieving low detection and quantitation limits. btaining very low LD and LQ levels can be achieved by an increase in the analyte signal, a decrease in the noise, or both. Poor sensitivity is a problem observed for a number of analytes. The two most critical factors of sensitivity in LC-MS/MS are:. The chemical and physical properties of the sample. The composition of the mobile phase We have illustrated an undesirable combination of these two factors coming together in the reversed phase application to the right. App ID 65 icotine & Metabolites on Luna HILIC.8e.6e.e.e.0e.8e.6e.e.e.0e.8e.6e.e.e.0e.8e.6e.e.e.0e 8000.0 6000.0 000.0 000.0 0.0 Cotinine Peak Area,700 icotine Peak Area 8,900 Increase in sensitivity ornicotine Peak Area 69,00 0.5 ng on column 0. 0. 0.6 0.8.0...6.8.0...6.8.0.. min Column: Luna 5 µm HILIC Dimension: 00 x.0 mm Part o.: 00D-50-B0 Mobile Phase: Acetonitrile /00 mm Ammonium Formate, ph. (90:0) Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Sample:. Cotinine (MRM: 77/80). icotine (MRM: 6/80). ornicotine (MRM: 9/80). Difficult to retain polar compounds. The biological matrix creates an ion suppression zone, or the area in which many of the endogenous compounds in the biological matrix elute - the result is a shortcoming of LC- MS/MS commonly referred to as the Matrix Effect. Using the Luna HILIC column, we observe an increase in analyte retention away from the suppression zone - effectively decreasing noise. The high organic mobile phase offers more favorable desolvation and ionization conditions, resulting in an increase in analyte signal. By creating these more favorable conditions for both retention and ionization, Luna HILIC columns allow for improved sensitivity in the analysis of bioanalytical samples. Request the Technical ote! App ID 65 icotine & Metabolites on C8.8e.6e.e.e.0e.8e.6e.e.e.0e.8e.6e.e.e.0e.8e.6e.e.e.0e 8000.0 6000.0 000.0 000.0 0.0 Cotinine Peak Area 97,00 Elutes in ion suppression zone! ornicotine Peak Area,8 icotine Peak Area,89 0.5 ng on column 0. 0. 0.6 0.8.0...6.8.0...6.8.0..min Column: Gemini 5 µm C8 Dimension: 00 x.0 mm Part o.: 00D-5-B0 Mobile Phase: A: Water with 0. % v/v Formic Acid B: Acetonitrile with 0. % v/v Formic Acid Gradient: A/B (97:) hold min, to (70:0) in min, to (97:) in 0.0 min, hold for.5 min Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Sample:. ornicotine (MRM: 9./80.). icotine (MRM: 6./05.9). Cotinine (MRM: 77./80.)

5 Benefits of HILIC Chromatography Improved Mass Spec Sensitivity Luna HILIC allows low level polar metabolites to be retained on column past the critical ion suppression zone, allowing: S/ = 0.6 Polar Compound in HILC Mode Increased MS sensitivity Higher signal-to-noise ratio (S/) Great MS sensitivity Column: Luna µm HILIC Dimension: 00 x.0 mm Part o.: 00D-9-B0 Mobile Phase: Acetonitrile / 00 mm Ammonium Formate, ph. (90:0) Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Sample: Bamethan Primary Ion Suppression Region App ID 6 0 t o min S/ = 6. Polar Compound in C8 Reversed Phase Ion Suppression Region is from 0.5-.0 min t o = ~ 0.5 min Poor MS sensitivity Column: Gemini µm C8 Dimension: 00 x.0 mm Part o.: 00D-5-B0 Mobile Phase: 0. % Formic Acid / Acetonitrile (97:) Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Sample: Bamethan t R t o - 0.5 k'== = t o 0.5 App ID 6 t o 0 min

6 Benefits of HILIC Chromatography Increased Sample Throughput HILIC mode allows you to directly inject after sample preparation in high organic eluents and therefore skip the time-consuming evaporation and reconstitution step. Increased Sample Throughput with Luna HILIC Rational method development today includes optimization of chromatographic conditions, detector conditions, and sample preparation design. Improving the interface between these three parameters can increase productivity and decrease analysis cost. HILIC Workflow Step. Sample Preparation LLE SPE PPT Skip Step! Step. Analysis ADME and DMPK departments in pharmaceutical companies, as well as contract research organizations (CRs), provide an excellent example of the need for a more elegant chromatographic/ sample preparation(s) strategy. In this arena, the two most commonly used sample preparation techniques remain protein precipitation (PPT) and solid phase extraction (SPE). The commonly used elution solvents for these techniques have stronger organic strength than the starting mobile phase used in typical reversed phase (RP) column gradient methods. This disparity will generally lead to significant band broadening or very early elution in subsequent chromatographic injections. Therefore, eluent evaporation, followed by reconstitution with a mobile phase compatible solvent is necessary. The elimination of these time-consuming steps would greatly enhance sample throughput in the high volume analysis lab. Luna HILIC columns increase laboratory throughput by improving the interface between chromatography and sample cleanup. Luna HILIC allows for the direct injection of the high organic containing elution solvents of both SPE and protein precipitation. In the case of HILIC, these are weaker elution solvents than the HILIC mobile phase and will not contribute to band broadening or early elution. Elimination of the final evaporation and reconstitution steps can significantly decrease (up to 50 %) the total time spent on sample preparation. RP Workflow Step. Sample Preparation LLE SPE PPT Step. Evaporate and Reconstitute Step. Analysis Request the Technical ote!

7 Benefits of HILIC Chromatography Increased Sample Throughput Injected after Sample Preparation (5: Acetonitrile/Water) In HILIC chromatography, a 5: acetonitrile : water injection solvent constitutes a weak injection solvent. Morphine and metabolites were injected on the Luna HILIC column in a typical sample preparation eluent 5: acetonitrile : water and the compounds are well retained and well resolved. Column: Luna µm HILIC Dimension: 00 x.0 mm Part o.: 00D-9-B0 Mobile Phase: A: Acetonitrile / 00 mm Ammonium Formate, ph. (90:0) B: Acetonitrile / 0 mm Ammonium Formate, ph. (50:50) Gradient: A/B (00:0) hold for min to (0:00) in min, A/B (0:00) hold for.5 min Flow Rate: 0. ml/min Injection Volume: 5 µl Detection: Mass Spectrometer (MS) Sample:. Morphine. ormorphine. Morphine--ß-Glucuronide App ID 65 App ID 66 0 5 6 7 min 8 9 min Injected after Sample Preparation (5: Acetonitrile/Water) In reversed phase chromatography, injecting solutes in typical sample preparation eluents such as 75 85 % organic will result in unfavorable results, such as broad peaks or loss retention. Morphine and metabolites lose all retention and elute in the void. Co-elution 0 5 6 min min With time consuming dry down / reconstitution step. Column: Synergi µm Polar-RP Dimension: 00 x.0 mm Part o.: 00D-6-B0 Mobile Phase: A: Water with 0. % Formic Acid B: Acetonitrile with 0. % Formic Acid Gradient: A/B (97:) hold for min, to (50:50) in.8 min Flow Rate: 0. ml/min Detection: Mass Spectrometer (MS) Injection Volume: 5 µl Sample:. Morphine. ormorphine. Morphine--ß-Glucuronide App ID 67 Injected after Evaporation and Reconstitution 0 min

Benefits of LUA HILIC Stability High ph Stability Test icotinamide 0 Diol phases provide: Day ne Cyanocobalamin Thiamine 6 icotinamide Attractive water layer retention Luna 5 µm HILIC 50 x.6 mm 00F-50-E0 A: Water, B: Acetonitrile, C: 00 mm Ammonium Acetate ph 8.5 0:90:0 (A/B/C) to 0:50:0 (A/B/C) in 5 min.0 ml/min UV @ 60 nm Ambient Gradient: Flow Rate: Detection: Temperature: ph = 8.5 Luna HILIC Columns Utilize a Stable Cross-linked DIL Phase The stabilizing effects of our formulated ethylene bridges provide flexible covalent bonds that are robust enough to withstand harsh conditions that would cause most other Diol phases to bleed. Column: Dimension: Part o.: Mobile Phase: 0 min 8 Thiamine After 700 column volumes Cyanocobalamin on ph dependent hydrogen bonding that is important to the HILIC retention mechanism 0 Dipole-dipole interactions 6 0 min 8 Absence of dissociable moieties Low ph Stability Test H H H H H H H H H H H H H H H H H H H H H H H H 0 H H H H H H H Luna 5 µm HILIC 50 x.6 mm 00F-50-E0 A: Water, B: Acetonitrile, C: 0. %TFA in Water, ph. 0:90:0 (A/B/C) to 0:50:0.0 ml/min UV @ 60 nm Ambient Day ne Cyanocobalamin Gradient: Flow Rate: Detection: Temperature: ph =. H Column: Dimension: Part o.: Mobile Phase: 0 min After 700 column volumes Cyanocobalamin 0 0 min Addition of TFA Please note the retention effects caused by the TFA modifier. This weak ion pair reagent associates with the charged groups on the polar vitamins and causes them to become increasingly hydrophobic, REDUCIG retention in HILIC mode! In this example, TFA was used to illustrate low ph stability. For recommended buffers, please see the HILIC LC/MS Method Development Strategy on pp. -5.

Benefits of LUA HILIC Batch-to-Batch Reproducibility 9 µm 5 µm Batch Batch to 5 6 t o 5 6 App ID 68 5 6 7 min to 5 6 7 min t o 5 6 7 min 5 5 6 6 Batch Batch App ID 60 5 6 7 t o 5 6 5 6 7 to 5 6 5 6 7 Batch Batch Columns: Luna µm HILIC Luna 5 µm HILIC Dimension: 50 x.6 mm Mobile Phase: A: Acetonitrile B: 00 mm Ammonium Formate, ph. C: Water Gradient: A/B/C (90:0:0) to (50:0:0) in 5 min Flow Rate:.0 ml/min Detection: UV @ 60 nm Sample:. PABA. icotinamide. Riboflavin. icotinic Acid 5. Pyridoxine 6. Thiamine Low MS-Bleed The increased stability of the cross-linked DIL provides the ultra-low bleed profile required for high sensitivity LC-MS/MS applications. 5.0e7 0.65.8e7.6e7 0.0.e7.e7.0e7.8e7.6e7.e7.e7.0e7.8e7.6e7.e7.e7.0e7.8e7.6e7.e7.e7.0e7 8.0e6 6.0e6.0e6.0e6 0.0.0.5.80.65.05.0.50 0.5.0.5.0.5.0.5.0.5 5.0 5.5min.6.9.06.56 Red = Luna HILIC Blue = Union 5.6 Mobile Phase: A: Water B: Acetonitrile Gradient: A/B (0:90) for.5 min to A/B (50:50) in min, hold.5 min, step to A/B (0:90), hold for 5 min

0 Benefits of LUA HILIC Selectivity 5 Luna 5 µm HILIC t o 6 Baseline resolution of all peaks App ID 6 App ID 67 0 6 8 min t o SeQuant 5 µm ZIC -HILIC 5 6 (Thiamine-no elution) 0 6 8 min Conditions same for all columns Columns: As noted Dimension: 50 x.6 mm Mobile Phase: Acetonitrile/00 mm Ammonium Formate, ph. (90:0) Flow Rate:.0 ml/min Detection: UV @ 60 nm Sample:. PABA. icotinamide. Riboflavin. icotinic Acid 5. Pyridoxine 6. Thiamine Waters Atlantis 5 µm HILIC to 5 App ID 6 6 (Thiamine-no elution) 0 6 8 min

HILIC METHD DEVELPMET STRATEGY Step-by-Step Approach Probes:. p-aminobenzoic Acid. icotinamide. Riboflavin H.77 H.6 HC Pro-Vitamin B (logp=-0.6, pka=.6b) Vitamin B Complex (logp=0.78, pka=.77a,.69b) 6. Thiamine H 7.97 5.58 HC H H 5.08 H Broad range of pka values Variety of functional groups Wide logp range (5. units) H.5 Part : 8. Vitamin C (logp=-., pka=.5a, 8.a) The chosen vitamins used in our testing incorporate the following: Provide the basis for further method optimization, if needed 5.5 8. Cyanocobalamin The vitamins chosen have a wide scope of functionalities and demonstrate key points of HILIC chromatography well. Approximate best separation conditions using set of conditions that provide the most information in the least time Using set of generic conditions, quickly determine HILIC applicability. Screen for best starting conditions.. Vitamin B (logp=-.6, pka=5.5b) Vitamin B6 (logp=0.5, pka=5.58b, 8.60a) Vitamins Profile. Method Development H + Quickly determine applicability of HILIC for your compounds Part :.80 S.. 7. Ascorbic Acid H.0 iacin, B (logp=0.5, pka=.77a,.0b) CH H 8.60 H Vitamin B (logp=-.6, pka=7.97a) 5. Pyridoxine bjective H HC.69b.77 H H H H HC. icotinic Acid H CH HC Co CH CH H H H C P H H H.68 CH CH H CH H H H H H H H. H H Evaluate Method 9. Folic Acid.08 Evaluate the results of screening process H Vitamin B9 (logp=-0.0, pka=.68a,.a, 8.07a,.90b,.08b).90 Part : Method ptimization Further optimization towards achieving desired criteria CH H Vitamin B (logp=-0.90, pka=.59a, 6.00b, 8.9b)

HILIC METHD DEVELPMET STRATEGY Part : Method Development Step. Choose mobile phase conditions Step. Prepare buffer solutions Use an inverse gradient beginning at 90 % Acetonitrile A Hold 90 % Acetonitrile isocratically for.5 min - (period is used to determine if a compound is weakly retained in HILIC mode) B The gradient part of the elution profile is the ideal elution area. If a compound elutes during the gradient then there is maximum flexibility in adjusting selectivity C Hold last.5 minutes isocratically at 50 % Acetonitrile. (This period is used to determine if a compound is strongly retained in HILIC mode) Screening both acidic and basic mobile phase conditions A B 00 mm Ammonium Formate, ph.: Weigh approx 6. g of Ammonium Formate and dissolve in liter (MQ) water. Add 0.5 ml of formic acid and mix well. Take 0 ml of the aliquot and measure the ph of the aliquot. 00 mm Ammonium Acetate, ph 5.8: Weigh approx 7.7 g of Ammonium Acetate and dissolve in liter (MQ) water. Add 0.5 ml of acetic acid and mix well. Take 0 ml of the aliquot and measure the ph of the aliquot. 00 90 A The buffer solutions recommended in A and B have been selected based upon: Luna HILIC ph. A 80 70 60 50 B C The ph desired to attain separations with polar analytes based upon hydrogen bonding High solubility in eluents with high Acetonitrile content Compatibility with MS detection Luna HILIC ph 5.8 B 0 0 6 8 0 min Practical Considerations for HILIC Gradient: Make three () injections to test equilibration Equilibration ~ 0 Column Volumes at 90 % Acetonitrile Practical Considerations for HILIC Buffering: ph values used here are aqueous ph values pk a s of acidic compounds increase with increasing organic pk a s of basic compounds decrease with increasing organic

HILIC METHD DEVELPMET STRATEGY Part : Method Development Step. Screen alternate column chemistries in both buffer solutions There are significant selectivity differences between HILIC columns. Apply generic starting gradient, screen all three columns with both buffer solutions. A ph 5.8 Luna HILIC (Cross-linked Diol) A ph. Luna HILIC (Cross-linked Diol) App ID 6 App ID 67 App ID 6 App ID 66 App ID 60 App ID 65 B Zwitterion B Zwitterion C Silica C Silica Columns: As noted Dimension: 50 x.6 mm Mobile Phase: A: Acetonitrile B: Water C: 00 mm Ammonium Acetate, ph 5.8 Gradient: A/B/C (90:5:5) for.5 min to A/B/C (50:5:5) in 7.5 min, hold for.5 min. Re-equilibrate @ A/B/C (90:5:5) for 7.5 min. Flow Rate: ml/min Detection: UV @ 60 nm Sample:. PABA,. icotinamide,. Riboflavin,. icotinic Acid, 5. Pyridoxine, 6. Thiamine, 7. Ascorbic Acid, 8. Cyanocobalamin, 9. Folic Acid Columns: (A) Luna 5 µm HILIC (B) SeQuant 5 µm ZIC - HILIC (C) Luna 5 µm Silica () Columns: As noted Dimension: 50 x.6 mm Mobile Phase: A: Acetonitrile B: Water C: 00 mm Ammonium Formate, ph. Gradient: A/B/C (90:5:5) for.5 min to A/B/C (50:5:5) in 7.5 min, hold for.5 min. Re-equilibrate @ A/B/C (90:5:5) for 7.5 min. Flow Rate: ml/min Detection: UV @ 60 nm Sample:. PABA,. icotinamide,. Riboflavin,. icotinic Acid, 5. Pyridoxine, 6. Thiamine, 7. Ascorbic Acid, 8. Cyanocobalamin, 9. Folic Acid

HILIC METHD DEVELPMET STRATEGY Part : Evaluate Method Rank the best results from your screening process Look for the critical compound(s) that matters for your separation goals Reproducibility, availability and robustness will matter in the future, keep all your goals in mind Ranking Luna HILIC ph 5.8 # App ID 60 In this example, Luna HILIC gave the best performance in terms of retention, selectivity and peak shape Zwitterion ph 5.8 # App ID 6 Silica ph. # App ID 67 Practical Considerations for Method Evaluation: If results meet your criteria in terms of retention time, selectivity, and efficiency, you may have your final method. If adjustments are still needed, see the following section on method optimization.

HILIC METHD DEVELPMET STRATEGY 5 Part : Method ptimization Important considerations for method optimization The most suitable column and buffer solution to continue with will have shown favorable signs of retention, selectivity, and peak shape we now seek to improve them. Characteristic performance criteria are approximated below. Retention Time k > to reduce ion suppression k <0 for fast cycle Selectivity. < Rs <.5 optimal for MS Efficiency/ Peak Shape Maximize 0.8 < Asym <.5 To achieve these performance criteria in HILIC mode, we suggest:. Adding organic modifier. Adjusting ionic strength. Adjusting initial % organic modifier Important Considerations for Adding rganic Modifier: May produce some unexpected results Addition of ethyl acetate increases the retention and selectivity of some compounds Addition of THF generally reduces retention and selectivity for all compounds Important Considerations for Adjusting Ionic Strength: Ionic strength can be an effective parameter for adjusting selectivity, retention, and efficiency Start with minimum 5 mm buffer for best results Important Considerations for Initial % rganic Modifier: Impact of 5 % increase very noticeable Surface equilibration is a relatively slow process

6 RDERIG IFRMATI over 0 years of proven reproducibility, you can be With confident in your choice to develop methods on Luna μm Minibore Columns (mm) SecurityGuard Cartridges μm Analytical Columns (mm) SecurityGuard Cartridges 50 x.0 00 x.0 50 x.0 x.0 mm for ID:.0-.0 mm 50 x.0 50 x.0 00 x.6 50 x.6 x.0 mm for ID:.0-.0 mm x.0 mm for ID:.-8.0 mm Phases HILIC - 00B-9-B0-00D-9-B0-00F-9-B0 -/0pk AJ0-88 Phases HILIC - 00B-9-Y0-00F-9-Y0-00D-9-E0-00F-9-E0 -/0pk AJ0-88 -/0pk AJ0-89 Silica() 00B-6-B0 00D-6-B0 00F-6-B0 AJ0-7 Silica() 00F-6-Y0 00D-6-E0 00F-6-E0 AJ0-7 AJ0-8 C8() 00B-8-B0 00D-8-B0 00F-8-B0 AJ0-89 C8() 00B-8-Y0 00F-8-Y0 00D-8-E0 00F-8-E0 AJ0-89 AJ0-90 C8() 00B-5-B0 00D-5-B0 00F-5-B0 AJ0-86 C8() 00B-5-Y0 00F-5-Y0 00D-5-E0 00F-5-E0 AJ0-86 AJ0-87 C 00B-5-B0 00D-5-B0 00F-5-B0 AJ0-0 C 00B-5-Y0 00F-5-Y0 00D-5-E0 00F-5-E0 AJ0-0 AJ0-05 Phenyl-Hexyl 00B-56-B0 00D-56-B0 00F-56-B0 AJ0-50 Phenyl-Hexyl 00B-56-Y0 00F-56-Y0 00D-56-E0 00F-56-E0 AJ0-50 AJ0-5 H 00B-77-B0 00D-77-B0 00F-77-B0 AJ0-0 H 00B-77-Y0 00F-77-Y0 00D-77-E0 00F-77-E0 AJ0-0 AJ0-0 5 μm Minibore Columns (mm) SecurityGuard Cartridges SecurityGuard Analytical Cartridges require universal holder Part o.: KJ0-8 00 x.0 x.0 mm for ID:.0-.0 mm Phases - -/0pk HILIC 00D-50-B0 AJ0-88 Phases SecurityGuard Analytical Cartridges require universal holder Part o.: KJ0-8 5 μm Analytical Columns (mm) 50 x.0 00 x.6 50 x.6 50 x.6 x.0 mm for ID:.0-.0 mm SecurityGuard Cartridges x.0 mm for ID:.-8.0 mm - - - - -/0pk -/0pk HILIC 00F-50-Y 00D-50-E0 00F-50-E0 00G-50-E0 AJ0-88 AJ-89 Silica() 00D-7-E0 00F-7-E0 00G-7-E0 AJ0-7 AJ0-8 C5 00F-0-Y0 00D-0-E0 00F-0-E0 00G-0-E0 AJ0-9 AJ0-9 C8 00F-00-Y0 00D-00-E0 00F-00-E0 00G-00-E0 AJ0-89 AJ0-90 C8() 00F-9-Y0 00D-9-E0 00F-9-E0 00G-9-E0 AJ0-89 AJ0-90 C8 00F-0-Y0 00D-0-E0 00F-0-E0 00G-0-E0 AJ0-86 AJ0-87 C8() 00F-5-Y0 00D-5-E0 00F-5-E0 00G-5-E0 AJ0-86 AJ0-87 C 00F-55-Y0 00D-55-E0 00F-55-E0 00G-55-E0 AJ0-0 AJ0-05 Phenyl-Hexyl 00F-57-Y0 00D-57-E0 00F-57-E0 00G-57-E0 AJ0-50 AJ0-5 H 00F-78-Y0 00D-78-E0 00F-78-E0 00G-78-E0 AJ0-0 AJ0-0 SCX 00D-98-E0 00F-98-E0 00G-98-E0 AJ-07 AJ0-08 Material Characteristics Packing Material Particle Shape/ Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load % End Capping ph Range Luna HILIC Spherical, 5 00 00 5.7 o.5-8.0 Luna C5 Spherical 5, 0 00 0.5 Yes.5-0 Luna C8()-HST Spherical.5 00 00 7.5 Yes.5-0 Luna C8() Spherical, 5,0,5 00 00 7.5 Yes.5-0 Luna C8() Spherical, 5, 0, 5 00 00.5 Yes.5-0 Luna Phenyl-Hexyl Spherical, 5, 0, 5 00 00 7.5 Yes.5-0 Luna Silica () Spherical, 5, 0, 5 00 00 o Luna C Spherical, 5, 0 00 00 7.0 Yes.5-7.0 Luna H Spherical, 5, 0 00 00 9.5 o.5- Luna SCX Spherical 5, 0 00 00 0.55 % Sulfur Load o.0-7.0 If Luna does not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 5 days and keep the Luna column for FREE.

7 THER ECESSITIES Protect Your Column Easy to use Cost-effective Universal fit to virtually all manufacturer s columns o change in chromatography I consider SecurityGuard a necessity, not an accessory V. Agarwal - Connecticut, USA For more information: www.phenomenex.com/securityguard Control Temperature Improve chromatography More reproducible results Eliminate varying column temperature ther great products: Column Selectors Quickly screen up to 6 HPLC columns Develop, optimize, and validate methods faster 5-90 C Syringe Filters Rapid filtration High quality Available in 6 membrane types Luna is a registered trademark of Phenomenex, Inc. SecurityGuard is a trademark of Phenomenex, Inc. Atlantis is a registered trademark of Waters Corp. ZIC is a registered trademark of SeQuant AB. 007 Phenomenex, Inc. All rights reserved. Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/termsandconditions

www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department by telephone, fax or email: international@phenomenex.com. tel.: fax: email: Australia 0-98-6 0-98-65 info@ phenomenex.com.au Austria 0-9-0 0-9-00 anfrage@ phenomenex.com Canada (800) 5-68 (0) 8-7768 info@ phenomenex.com Denmark 8 808 80 665 dkinfo@ phenomenex.com France 0 0 09 0 0 0 09 franceinfo@ phenomenex.com Germany 060-5880-0 060-5880- anfrage@ phenomenex.com tel.: fax: email: Ireland 0 7 505 + 65-50796 eireinfo@ phenomenex.com Italy 05 7676 05 750 italiainfo@ phenomenex.com ew Zealand 09-78095 09-78095 info@ phenomenex.co.nz Puerto Rico (800) 5-HPLC (0) 8-7768 info@ phenomenex.com United Kingdom 065-5067 065-50796 ukinfo@ phenomenex.com USA (0) -0555 (0) 8-7768 info@ phenomenex.com 588_L