Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent up to 00% for elution of hydrophobic cations and column cleaning. Compatible with conductivity and UV detectors. One particle size: 0 µm. Six column internal diameters:.0 to 0.0 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Monovalent Cations Glycine and Ethanolamine N-Methylglucamine PRP-X00,. x 0 mm (P/N 79). Lithium. Sodium. Ammonium. Potassium. Cesium PRP-X00,. x 0 mm (P/N 79). Glycine. Sodium. Ethanolamine PRP-X00,. x 0 mm (P/N 79). N-Methylglucamine mg/ml 0 0 Conditions:.: mm Nitric Acid: Methanol. Isocratic. Ambient. ml/min. 00 µl, Conductivity. 0 6 Conditions: mn Nitric Acid. Ambient. Isocratic. ml/min. 0 µl, Conductivity. 0 8 Conditions: mn Nitric Acid. Isocratic. Ambient. ml/min. µl, Conductivity. I.D. x Length 0 µm I.D. x Length 0 µm.0 x 0 mm 79779. x 0 mm 79.0 x 00 mm 79780. x 0 mm 79.0 x 0 mm 7978.6 x 0 mm* 79.0 x 0 mm 7978.6 x 0 mm* 798. x 0 mm 799.6 x 0 mm* 797. x 0 mm 797 7.0 x 0 mm 7989. x 00 mm 796 0.0 x 0 mm 799 Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) 796 7968 Replacement Cartridges (/pk) 799 7969 Semiprep/Preparative Guard Column Starter Kits ( holder, cartridge) 797 Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 m *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For Steel Columns*** 0
PRP-X00 Cation Exchange Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water. Faster analysis when compared to competitor s columns. Detection levels of less than 0 ppb when using the post column, OPA derivatization technique. Applicable to other separations, such as inositol and sugar alcohols. Two particle sizes: 7 and -0 µm. Five column internal diameters:. to. mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Glyphosate and Metabolite Inositol in Vitamin Matrix Sugar Alcohols PRP-X00,. x 0 mm, 7 µm (P/N 797). Glyphosate. Aminomethylphosphonic Acid PRP-X00,. x 0 mm, 7 µm (P/N 797),,, and. Unknown. Inositol PRP-X00,. x 0 mm, 7 µm (P/N 797). Adonitol 00 ppm. Arabitol 00 ppm. Xylitol 00 ppm. Mannitol 00 ppm. Sorbitol 00 ppm 0 6 Conditions: 0.00M Monobasic Potassium Phosphate. Isocratic. Ambient. 0. ml/min. 00 µl, Excitation wavelength 8 nm. Emission wavelength nm. Post Column Conditions: Oxidation Solution Flow Rate: 0.0 ml/min; Reaction Coil: ml (0.0 cm ID X m); Reaction Time:. min; Temp: 8 C Derivatization Solution: 0.0 ml/min; Reaction Coil: 0.0 ml (0.0 cm ID X m), Ambient. Conditions: 8: Acetonitrile : 0mN Sodium Hydroxide. Isocratic. Ambient. ml/min. 00 µl, Pulsed Amperometric Dual Gold Electrode. E=00 mv T=76 msec E=000 mv T=66 msec E=-800 mv T=99 msec Post Column Conditions: 0.N Sodium Hydroxide solution at ml/min. 0 0 0 0 Conditions: A) Acetonitrile; B) Water. Linear Gradient 0-0% B in 0 min. Ambient. ml/min. µl, Pulsed Amperometric Dual Gold Electrode; delay 0 msec E=00mV T=70msec E=000mV T=0msec 0 0 0 E=-800mV T=00msec Post Column Conditions: 0.N Sodium Hydroxide at ml/min. I.D. x Length 7 µm -0 µm. x 0 mm 7998. x 0 mm 7989. x 0 mm 7977. x 0 mm 797 796.6 x 0 mm* 7987 0.0 x 0 mm 797. x 0 mm 79 Analytical Guard Column Starter Kit ( holder, cartridges) 7976 Replacement Cartridges (/pk) 7977 C8 Guard Column for EPA Glyphosate Application Starter Kit ( holder, cartridges) 799 Replacement Cartridges (/pk) 79 PRP-X00 Semiprep/Preparative Guard Column Starter Kit ( holder, cartridge) 79 Replacement Cartridges (/pk) 79 * Analytical guard column for PEEK columns is.0 x 8.0 m ** Analytical guard column for steel columns is. x 0 mm *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For PEEK Columns* For Steel Columns** For Steel Columns***
PRP-X800 Cation Exchange Polymeric cation exchange columns for the isocratic separation of mono and divalent cations. Isocratic separation of lithium, sodium, ammonium, potassium, magnesium and calcium. Gradient separation of transition metals. Excellent durability (stable to any concentration of water or organic solvent). One particle size: 7 µm. Two column internal diameters:. to.6 mm. Two column materials: 6 stainless steel and PEEK. Guard columns in 6 stainless steel and PEEK. Mono and Divalent Cations Transition Metals Transition Metals PRP-X800,. x 0 mm, 7 µm (P/N 7988). Lithium ppm. Sodium ppm. Ammonium ppm. Potassium ppm. Magnesium ppm 6. Calcium ppm 0 6 Conditions: mm Cupric Sulfate. Isocratic. Ambient. 0.8 ml/min. 0 µl, Indirect UV 0 nm. 6 PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Cadmium 6 ppm. Zinc 6 ppm. Cobalt 6 ppm 0 0 0 Conditions: A) 0mM Ammonium Acetate. ph.; B) Trifluoroacetic Acid in Water ph.. Linear Gradient -% B in 0 min. ml/min. 00 µl, Post Column Reaction: 0.0% -(-pyridylazo)resorcinol in M Ammonium Hydroxide 0. ml/min. Visible 0 nm. PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Zinc 6 ppm. Cadmium 6 ppm. Lead 6 ppm 0 8 6 Conditions: A). mm Ethylenediamine ph.; B) 00mM Ethylenediamine ph.7. Linear Gradient 00% A (0- min.), 0-00% B in (-0 min.) ml/min, 00 µl, Post Column Reaction: 0.0% -(-pyridylazo) resorcinol (PAR) in M Ammonium Hydroxide, 0. ml/min. Visible 0 nm. I.D. x Length 7 µm. x 0 mm 798. x 0 mm 7988.6 x 0 mm* 798.6 x 0 mm* 7989 Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) 7980 798 Replacement Cartridges (/pk) 798 798 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm Visit the HAMILTON Application Compound Index at http://www.hamiltoncompany.com/hplc/app_index_.asp or e-mail chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.
HC-0 Cation Exchange Polymeric % cross-linked soft-gel column for cation, ligand exchange separation of carbohydrates. Separate oligosaccharides up to DP8. Water mobile phase. Compatible with RI detectors. One particle size: 0 - µm. One column internal diameter: 7.8 mm. One column material: 6 stainless steel. Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79) 76. Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltooctaose + High Conversion Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79). Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltoheptaose+ 7 6 0 8 6 Conditions: Water. Isocratic. 80 C. 0.6 ml/min. µl, Refractive Index. 0 8 6 Conditions: Deionized Water. Isocratic. 80 C. 0.6 ml/min. 0 µl, Refractive Index. Guard Columns For Steel Columns* Gel-Type Cation Exchange Column I.D. x Length 0- µm 7.8 x 0 mm 79 Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) 79866 Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-0 guard column for steel columns is.6 x 0 mm
HC-7 Cation Exchange Polymeric 7.% cross-linked soft-gel columns for cation, ligand exchange separations of carbohydrates. Compatible with UV and RI detectors. Hydrogen form columns for USP L7 applications. Calcium form columns for USP L9 applications. Lead form columns for USP L applications. One particle size: 9 µm. Three column internal diameters:., 7.8 and 0.0 mm. One column material: 6 stainless steel. Three forms: calcium, lead and hydrogen. Malic Acid Citric, Lactic and Acetic Acids Dihydroxyacetone HC-7,. x 0 mm H + (P/N 7976). Maleic Acid ppm. Malic Acid 000 ppm. Fumaric Acid 0 ppm HC-7,. x 0 mm H + (P/N 7976). Citric, Acid 0 ppm. Lactic Acid 0 ppm. Acetic Acid 0 ppm HC-7, 7.8 x 0 mm Ca + (P/N 796). Formic Acid 0. mg/ml. Glycerol 0. mg/ml. Dihydroxyacetone 0. mg/ml 0 0 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 6 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 0 Conditions: 0.0M Calcium Chloride. Isocratic. 90 C. 0.6 ml/min. ul, Refractive Index. Gel-Type Cation Exchange Columns 9 µm, 9 µm, 9 µm, I.D. x Length Calcium Lead Hydrogen. x 0 mm 79 7976 7.8 x 00 mm 797 7.8 x 0 mm 796 798 79 0.0 x 0 mm 798 Visit the HAMILTON Application Compound Index at http://www.hamiltoncompany.com/hplc/app_index_.asp or e-mail chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. Guard Columns Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) 79866 Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-7 guard column for steel columns is.6 x 0 mm For Steel Columns*