KE = 1 2 mv2 = ev. (1)

Similar documents
Charge to Mass Ratio of the Electron

This lab was adapted from Kwantlen University College s Determination of e/m lab.

CHARGE TO MASS RATIO FOR THE ELECTRON

Finding e/m. Purpose. The purpose of this lab is to determine the charge to mass ratio of the electron. Equipment

Lab 1: Determination of e/m for the electron

Ratio of Charge to Mass for the Electron

THE CHARGE-TO-MASS RATIO OF THE ELECTRON (e/m)

Charge-to-mass ratio for the electron

Pre Lab for Ratio of Mass to. Charge of an Electron

Lab 6 - Electron Charge-To-Mass Ratio

The Measurement of e/m

Determining the Charge to Mass Ratio (e/m) for an Electron

Instruction Manual for EP-20 e/m of the Electron Apparatus

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

EXPERIMENT 2-6. e/m OF THE ELECTRON GENERAL DISCUSSION

Ratio of Charge to Mass (e/m) for the Electron

Charge to Mass Ratio of The Electron

Experiment 1 1. Charge- to- Mass Ratio of the Electron Physics 2150 Experiment No. 1 University of Colorado

Lab in a Box Measuring the e/m ratio

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Charge to Mass Ratio of Electron Lab 11 SAFETY

Electron charge-to-mass ratio

Laboratory 14: Ratio of Charge to Mass for the Electron

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Lab 7 - ELECTRON CHARGE-TO-MASS RATIO

Mass of the Electron

Electric Deflection of Electrons

e/m APPARATUS Instruction Manual and Experiment Guide for the PASCO scientific Model SE D 5/ PASCO scientific $5.

Charge to Mass Ratio of The Electron

MAGNETISM LAB: The Charge-to-Mass Ratio of the Electron

Brown University PHYS 0060 Physics Department LAB B -190

v = E B FXA 2008 UNIT G485 Module Magnetic Fields BQv = EQ THE MASS SPECTROMETER

Franck-Hertz Experiment in Neon/Hg

B = 8 0 NI/[r (5) 3/2 ],

E/M. Hunter Layman Bridgewater College 1/16/2016

PhysicsAndMathsTutor.com 1

THE CHARGE-TO-MASS RATIO OF THE ELECTRON

Experiment V Motion of electrons in magnetic field and measurement of e/m

Experiment 2 Deflection of Electrons

CHARGED PARTICLES IN FIELDS

Lab 7: Magnetic fields and forces Lab Worksheet

Diffraction of Electrons

EXPERIMENT 15. The Frank Hertz Experiment. 1. Pre-Laboratory Work [2 pts] Lab section: Partner's name(s): Grade:

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

Magnetic Deflection of Electrons

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

The e/m Ratio of the Electron

Deflection of Electrons

Charge to mass Ratio. Nature of the Atom: Dalton's Contributions to Science. 6) qm ratio notes.notebook. December 13, 2018

Experiment 5 Deflection of Electrons

PHYSICS 12 NAME: Electrostatics Review

Chapter 1 The discovery of the electron 1.1 Thermionic emission of electrons

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

The Franck-Hertz Experiment David Ward The College of Charleston Phys 370/Experimental Physics Spring 1997

PhysicsAndMathsTutor.com 1

The Ratio of Charge to Mass (e/m) for an Electron

1 Written and composed by: Prof. Muhammad Ali Malik (M. Phil. Physics), Govt. Degree College, Naushera

3B SCIENTIFIC PHYSICS

Downloaded from

EXPERIMENT #5 The Franck-Hertz Experiment: Electron Collisions with Mercury

Franck-Hertz experiment using Neon tube

Homework 2: Forces on Charged Particles

Photoelectric Effect Experiment

MEASUREMENT OF THE CHARGE TO MASS RATIO (e/m e ) OF AN ELECTRON

Chapter 4 - Moving Charges and Magnetism. Magnitude of the magnetic field at the centre of the coil is given by the relation,

ELECTRON SPIN RESONANCE

Experiment 4: Charge to mass ratio (e/m) of the electron

The Franck-Hertz Experiment

Franck-Hertz Experiment

Advanced Higher Physics. Electromagnetism

Chapter 23 Electric Potential. Copyright 2009 Pearson Education, Inc.

Physics 201: Experiment #1 Franck-Hertz Experiment

The Franck-Hertz Experiment Physics 2150 Experiment No. 9 University of Colorado

EXPERIMENT NO. 2. Electrostatic and Magnetic Deflection of Electrons in a Cathode Ray Tube

Physics. Student Materials Advanced Higher. Tutorial Problems Electrical Phenomena HIGHER STILL. Spring 2000

object objective lens eyepiece lens

THE FRANCK-HERTZ EXPERIMENT

Discovered by German scientist Johann Hittorf in 1869 and in 1876 named by Eugen Goldstein.

Your name: Your TA: Your section Day/Time: PHY 101 Practice in-class exam III Wednesday, November 28, 3:15-3:35PM

Unit 8: Electromagnetism

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Sparks in Gases: Line Spectra

University of Massachusetts, Amherst

AP Physics Electromagnetic Wrap Up

Fig. 2.1 I =... A [2] Suggest why it would be impossible for overhead cables carrying an alternating current to float in the Earth s magnetic field.

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil

ICPMS Doherty Lecture 1

Experiment 7: The Electron s Charge to Mass Ratio

(D) Blv/R Counterclockwise

MOCK CET PHYSICS PAPER 1

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

YOUR NAME Sample Final Physics 1404 (Dr. Huang)), Correct answers are underlined.

Quantum Physics and Atomic Models Chapter Questions. 1. How was it determined that cathode rays possessed a negative charge?

PSI AP Physics How was it determined that cathode rays possessed a negative charge?

Force Due to Magnetic Field You will use

review Problem 23.83

Electromagnetism Notes 1 Magnetic Fields

PhysicsAndMathsTutor.com

PHYSICS 126, MESA COLLEGE Laboratory Manual

Transcription:

The e/m ratio Objective To measure the electronic charge-to-mass ratio e/m, by injecting electrons into a magnetic field and examining their trajectories. We also estimate the magnitude of the earth s magnetic field. Introduction This experiment demonstrates how the electronic charge-tomass ratio can be measured from fairly simple measurements of electron trajectories in a magnetic field. Before we get into the details, consider the following simplified scenario. Let us accelerate an electron using a uniform electrostatic field E maintained over a distance d. The potential difference over this distance with be Ed and the electron will pick up a kinetic energy (KE)ofeV.Consequently KE = 1 2 mv2 = ev. (1) Now let us inject this electron into a uniform magnetic field B such that the direction of motion is perpendicular to the field lines. We can equate the forces on the electron, f = e v B = evb = mv2 r (2) and combining this with Eqn.(1) we have a compact expressionfor the charge to mass ratio e/m = 2V B 2 r 2. (3) So if we know the magnitude of the B field, the potential difference V and the radius of the path r, we can calculate the charge to mass ratio of the electron. This simple equation is quite informative if we remember that the left hand side is a constant. For example, if we inject electrons into the 1

magnetic field faster, by increasing the potential V,andweanddesireto maintain an orbit with the same radius, then this equation informs us we would have to increase the magnitude of the magnetic field. Alternatively, if we want to increase the radius of the circular orbit we would have to decrease the magnitude of the magnetic field. The experiment involves injecting electrons into a magnetic field that is generated by Helmholtz coils. The only difference between the experiment that I described above and the one you will perform is that the magnetic field will not be spatially uniform. It is very difficult to generate a spatially uniform magnetic field so we will have to make allowances for the non uniformity in our calculations. The Apparatus The electron trajectories will be measured in a vacuum tube which contains some hydrogen gas. Some of the electrons excite the hydrogen gas molecules and make the electron trajectory visible. The ionized gas emits a faint blue light which can easily be seen with the lights off. The pressure of the hydrogen gas in the tube ( 10 2 mm Hg) is selected so that the space charge produced by the electrons bunches the beam for this range of velocities. The electrons are generated by heating a filament. This gives some of the electrons in the filament enough energy to overcome the surface barrier and escape from the metal. These electrons are then accelerated by a potential applied between the filament (the cathode) and the metal cover surrounding the filament (the anode). After they have escaped through the nose code of the anode they can be deflected and focused by a grid which is oriented parallel to the beam. We refer to the current in the filament as the filament current, the voltage between the filament and the metal cover as the anode voltage, and the voltage between the deflector grids as the grid bias. After the electrostatic field, the electrons encounter a magnetic field. The magnetic field is generated by a pair of coils which are placed above and below the tube in the Helmholtz configuration, producing a fairly homogeneous magnetic field. The ideal Helmholtz configuration has the circular coils separated by the radius R. Our coils are not exactly in this configuration, and we will correct for this later. It can be shown that the magnetic field is 2

electrons GRID BIAS (V) CATHODE ANODE FILAMENT CURRENT I ANODE VOLTAGE Figure 1: Schematic of the cathode and the electron optics used to accelerate the electrons. maximum midway between the coils on axis. For an ideal Helmholtz pair, the magnetic field at the centre of the coils is B o = 8µ oni 5 5R, (4) where n is the number of turns. We may simplify this to B o = KI (5) where K is a constant for a given pair of coils and B o is measured in units of Tesla. The Helmholtz pair that you will use have a radius R =15.4 ± 0.5cm and a mean separation of 15.0 ± 0.5cm. They have 130 turns and generate a magnetic induction (KI) defined by K =(7.73 ± 0.04) 10 4 T/A. Because the radius is not equal to the separation the coils are not an ideal Helmholtz 3

pair. Therefore the value of K which we have given is slightly different from the ideal value. However, the relationship between B o and I is still linear. The magnitude of the field midway between the coils is of limited usefulness since the electron will be traversing an orbit in a plane parallel to the plane of the coils a distance r from the centre of the coil. Luckily the field is radially symmetric and we can allow for the fact that the field will be smaller as we move out from the centre of the coil. To estimate the field at a distance r from the centre of the coil use the following data which was supplied with the coils. The normalized distance from the centre of the coil r/r is listed with the normalized field B/B o,whereb o is the field at the centre. r/r B/B o 0.0 1.0000 0.1 0.99996 0.2 0.99928 0.3 0.99621 0.4 0.98728 0.5 0.96663 0.6 0.92525 0.7 0.85121 0.8 0.73324 0.9 0.56991 1.0 0.38007 Power supplies There is a power supply manufactured by Leybold. The switch S2 is ON/OFF. The switch S1 is to remain in the up position. It is a range selector and we will be using the upper 0-25 V and 0-300 V ranges. Beware, to increase the anode voltage, you rotate the knob clockwise. To increase the grid bias, you rotate the knob counter clockwise. Don t as me why! Before switching on, turn both to zero. After a few minutes, the filament will warm up and emit a yellow glow. Once it is hot, increase the anode voltage until the beam becomes visible. Change grid bias slightly to obtain best beam definition. 4

r electrons R HELMHOLTZ COILS Figure 2: Plan view of the electron trajectory, which is approximately a circle with radius r, and the Helmholtz coils, which have radius R. Grid Bias Anode Voltage 0-25V S1 0-300V S2 On / Off Range Selector Figure 3: Schematic of the Leybold power supply. 5

The d.c. current for the Helmholtz field coils is adjusted by using the large rheostat located on the bench. By increasing the current in the coils you should be able to see the electron beam bend. The anode voltage controls both the beam intensity and the diameter of the electron orbit. For optimum sharpness the anode voltage should be between 150 and 250 V. The diameter of the beam circle is measured using the illuminated scale. Adjust the position of the scale so that images formed by the two surfaces of the plate glass appear parallel to and on each side of the plane of the electron beam, and along a diameter of the circular path of the beam. Procedure 1. Set the anode voltage (V ) to 150 V and increase the current in the Helmholtz coil until the diameter of the electron orbit (D) is8cm. Turn the tube gently in its wooden clamps about its long axis so that the beam forms a closed circle rather than a spiral. From the magnitude of the current in the Helmholtz coil calculate the field required to bend the electron into a circular orbit of diameter D =8cm with an anode voltage of 150 V. 2. Increase the anode voltage to 250 V in 20 V increments, measuring the current required to maintain the electrons in a circular orbit with D =8cm. 3. Repeat 1 and 2 for D =10cm. 4. Turn the tube through 180 degrees and reverse the direction of the current in the coils using the reversing switch. This bends the beam into a circle with the direction of electron motion reversed. 5. Repeat steps 1-3 with the polarity of the current reversed. 6. When you flip the orientation of the tube you must still apply the same total B field (B total ) in both cases, if the radius of the orbit is the same. However, you will find that the currents you apply to maintain the electrons in orbits of the same radius are different. The larger we 6

will call I big and the smaller we will call I small. Obviously, in the first case the earth s magnetic field B earth is opposing the field generated by the coil and in the second case the earth s field is adding to the field generated by the coil. Considering both cases in turn, we have and B total = B big B earth = KI big B earth (6) These can be added to give B total = B small + B earth = KI small + B earth (7) and subtracted to give B total = K 2 (I small + I big ), (8) B earth = K 2 (I big I small ). (9) Use B total to calculate e/m for each measurement pair. Average these to produce an estimate of e/m. 7. Calculate the component of the earth s magnetic field normal to the plain of the Helmholtz pair by averaging all estimates of B earth. Subtract 1% from your anode voltage measurements to correct for the voltage drop in a protection resistor included in the leads. Errors in the digital meters should be taken as ±1 in the last digit. After the experiment Do not disconnect the leads, but ensure that the power supply and the coil current are switched off. should be in the central position. 7 The reversing switch

Analysis What is the discrepancy between your experimental determination of e/m and the accepted value? Does this lie within your estimated uncertainty? e m =1.7588 1011 C/kg. (10) Estimate the magnitude of the earth s magnetic field (actually the component normal to the coil). For the formal report discuss whether you would expect the orbit with D =8cm or the orbit with D =10cm to give you a more accurate estimate of the e/m ratio. Draw a picture of the magnetic flux lines generated by the earth. 8