Performance of the MCP-PMT for the Belle II TOP counter

Similar documents
PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

Construction of the Belle II TOP counter

Time of Flight measurements with MCP-PMT

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

ARTICLE IN PRESS. Lifetime of MCP PMT. N. Kishimoto, M. Nagamine, K. Inami, Y. Enari, T. Ohshima

High quantum efficiency S-20 photocathodes for photon counting applications

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

PoS(PhotoDet 2012)010

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

PoS(PD07)031. General performance of the IceCube detector and the calibration results

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Development of Ring-Imaging Cherenkov Counter for Heavy Ions

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

PoS(PhotoDet 2012)008

arxiv: v1 [physics.ins-det] 6 Oct 2010

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

A RICH Photon Detector Module with G-APDs

The TORCH project. a proposed detector for precision time-of-flight over large areas. Roger Forty (CERN)

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

The Fast Interaction Trigger Upgrade for ALICE

The First Large Application of MPPC: T2K Neutrino Beam Monitor INGRID

Hands on Project: Large Photocathode PMT Characterization

A gas-filled calorimeter for high intensity beam environments

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

Photon Detector Performance and Radiator Scintillation in the HADES RICH

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Direct WIMP Detection in Double-Phase Xenon TPCs

arxiv:hep-ex/ v1 22 Apr 2002

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

Investigation of nuclear Equation of State (EoS) is an attractive subject not only for nuclear

Lecture 16 Light transmission and optical detectors

Novel Plastic Microchannel-Based Direct Fast Neutron Detection

PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB

GEM-based photon detector for RICH applications

Study of GEM-like detectors with resistive electrodes for RICH applications

Efficiency of modern large-area photo-detectors

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

The Aerogel Forward RICH detector for PANDA

Muon track reconstruction and veto performance with D-Egg sensor for IceCube-Gen2

OPTICAL PROPERTIES OF THE DIRC FUSED SILICA CHERENKOV RADIATOR

Status of the LHCb RICH and hadron particle identification

The Cosmic Ray Air Fluorescence Fresnel lens Telescope (CRAFFT) for the next generation UHECR observatory

Development of Secondary Electron Time Detector for Ion Beams

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

PHOTODETECTORS AND SILICON PHOTO MULTIPLIER

arxiv: v2 [physics.ins-det] 8 Feb 2013

Picosecond Time-of-Flight Measurement for Colliders Using Cherenkov Light

The R&D study for the KLOD experiment. at IHEP (Protvino) U-70 proton

PoS(ICRC2017)1052. Overview and Performance of the Wavelength-shifting Optical Module (WOM) The IceCube-Gen2 collaboration

II. 5. Study for NaI(Tl) and Scintillation Fiber with 80 MeV Proton Beam Toward ESPRI Experiment at NIRS-HIMAC, RIKEN-RIBF

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

A Start-Timing Detector for the Collider Experiment PHENIX at RHIC-BNL

Overview Physical processes PMT and electronics response Some results Plans

XMASS 1.5, the next step of the XMASS experiment

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Simulation and validation of the ATLAS Tile Calorimeter response

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

Functions Represent SiPM Response Especially Linear Behavior After Saturation

PMT Charge Response and Reconstruction of Position and Energy for a Reactor θ 13 Experiment

Characterisation of Silicon Photomultipliers for the T2K Experiment

TORCH: A large-area detector for precision time-of-flight measurements at LHCb

Zero degree neutron energy spectra measured by LHCf at s = 13 TeV proton-proton collision

Lecture 9. PMTs and Laser Noise. Lecture 9. Photon Counting. Photomultiplier Tubes (PMTs) Laser Phase Noise. Relative Intensity

EEE4106Z Radiation Interactions & Detection

New solid state photomultiplier. Dmitry Shushakov and Vitaly Shubin

Calibration of large water-cherenkov Detector at the Sierra Negra site of LAGO

Long-term stability plastic scintillation for LHAASO-KM2A

Cherenkov light imaging in particle and nuclear physics experiments

7. Particle identification

Particle Identification with Disc DIRC at PANDA

arxiv:hep-ex/ v1 12 Dec 1994

First Stage Analysis of the Energy response and resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

A study of silicon sensor for ILD ECAL

Design of the Mainz Active Polarized Proton Target

LIQUID XE DETECTOR FOR MU E GAMMA SEARCH

A proposal to study gas gain fluctuations in Micromegas detectors

RICH detectors for LHCb

Calibration of the BABAR CsI (Tl) calorimeter

GEM: A new concept for electron amplification in gas detectors

Development of a Time Projection Chamber with GEM technology in IMP. Herun yang Gas detector group

Hybrid Avalanche Photo Detector for Belle II ARICH detector

Status and Perspectives for KM3NeT/ORCA

GEM-based gaseous photomultipliers for UV and visible photon imaging

Quantum Efficiency Measurements of Dark Matter PMT

Muon track reconstruction and veto performance with D-Egg sensor for IceCube-Gen2

AIRFLY: Measurement of the Air Fluorescence induced by electrons

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

Information about the T9 beam line and experimental facilities

hadronic decays at BESIII Abstract hadronic decays using a double tag technique. Among measurement for twelve Λ c

PoS(ICRC2017)945. In-ice self-veto techniques for IceCube-Gen2. The IceCube-Gen2 Collaboration

Kagamiyama, Higashi-Hiroshima , Japan. Abstract

New Results from the DREAM project

Transcription:

Performance of the MCP-PMT for the Belle II TOP counter a, S. Hirose b, T. Iijima ab, K. Inami b, Y. Kato a, Y. Maeda a, R. Mizuno b, Y. Sato a and K. Suzuki b a Kobayashi-Maskawa Institute, Nagoya University b Graduate School of Science, Nagoya University E-mail: matsuoka@hepl.phys.nagoya-u.ac.jp A square-shaped micro-channel-plate photomultiplier tube (MCP-PMT) was developed for the Belle II time-of-propagation (TOP) counter. Because the TOP counter uses 512 MCP-PMTs in total, mass production of the MCP-PMTs was conducted and their performance was measured systematically. The following results are presented in this paper: the gain, the transit time spread (TTS), the relative collection efficiency and the quantum efficiency (QE). The mass production was successful as the TTS of all the MCP-PMTs was about 3 ps and the average QE at a 36 nm wavelength was greater than 28%. Degradation of the QE depending on the integrated output charge is a major issue of the MCP-PMT. Study on lifetime extension of the MCP-PMT with atomic layer deposition (ALD) coating is also presented; the lifetime of all the eleven samples with three additional production processes for lifetime extension was measured to be longer than 8.6 C/cm 2, or the average lifetime of the normal ALD-MCP-PMTs. International Conference on New Photo-detectors, PhotoDet215 6-9 July 215 Moscow, Troitsk, Russia Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4. International License (CC BY-NC-ND 4.). http://pos.sissa.it/

1. Introduction The time-of-propagation (TOP) counter [1 3] is a novel ring-imaging Cherenkov detector. It is a key device of particle identification in the Belle II experiment [4] to extend the physics reach toward a new physics. The feature of the TOP counter is that it measures the time of propagation of each Cherenkov photon with a precision better than 5 ps to distinguish a difference of Cherenkov angles. The Cherenkov radiator of the TOP counter is a 26 mm long, 45 mm wide and 2 mm thick quartz bar, in which Cherenkov photons are totally reflected and propagate toward the end of the bar. Then the photons are expanded by a wedged quartz, called prism, glued on the end of the bar and are detected by two rows of 16 micro-channel-plate photomultiplier tubes (MCP-PMTs). There is no choice other than an MCP-PMT to achieve the required time resolution for single photon detection and we have developed the MCP-PMT [5 1] for our application in collaboration with Hamamatsu Photonics K.K. Mass production of the MCP-PMTs was done successfully from 211 for three years as the Belle II detector is equipped with 16 modules of the TOP counter and hence 512 MCP-PMTs in total. This paper describes the performance of the mass-produced MCP-PMTs. In Sec. 2 the specification of the MCP-PMT is shown, and in Sec. 3 the actual performance measured for every MCP-PMT is described, including the gain, the transit time spread (TTS), the relative collection efficiency and the quantum efficiency (QE). Though the mass production of the MCP-PMTs finished, our study of the MCP-PMT was still active in terms of extension of the MCP-PMT lifetime, which is explained in Sec. 4. 2. Specification of the MCP-PMT The MCP-PMT for the TOP counter is square-shaped to cover the face of the prism as fully as possible. The outer size is 27.6 27.6 mm 2 and the thickness is 13.1 mm excluding the signal and high voltage pins. The size of the photocathode is 23. 23. mm 2. A multi-alkali photocathode, NaKSbCs, is adapted to have a high QE at short wavelengths; the QE peaks around 36 nm. Our requirement for the QE is at least 24% at the peak for every MCP-PMT and 28% or greater on average of all the MCP-PMTs. The MCP-PMT has enough gain to detect single photons owing to two-stage amplification by a pair of 4 µm thick MCPs. The MCP pore size is 1 µm in diameter with a 13-degree bias angle. The best time resolution of the MCP-PMT among photon sensors is derived from the electron multiplication in the short transit length inside the tiny MCP pores. Two types of the MCP-PMT is used for the TOP counter: about a half of the MCP-PMTs with the conventional MCPs were produced firstly, and then the remaining MCP-PMTs were able to be produced using MCPs with atomic layer deposition (ALD) coating [11]. The ALD-MCP-PMT has a longer lifetime than the conventional one because the ALD layer prevents outgassing, which is known to be the source of the QE degradation [9], caused by the secondary electrons impinging on the MCP substrate. The anode of the MCP-PMT is divided into sixteen 5.275 5.275 mm 2 pixels. The performance measurement described below was done for all the sixteen channels. 2

3. Measured performance of the MCP-PMT 3.1 Measurement setups The gain, the TTS and the relative collection efficiency were measured as a function of the applied high voltage using single photons from a pico-second pulse laser. The wavelength of the laser was approximately 4 nm. The laser was attenuated by two neutral density filters, was collimated by two slits and was divided by a half mirror to be hit on the MCP-PMT and a reference PMT which was used to calibrate the laser intensity. The laser intensity was adjusted to have single photons, for which the hit rate of the MCP-PMT should be several percents. The size of the laser spot on the MCP-PMT was about 1 mm in diameter. The MCP-PMT was set on a moving stage and the laser spot was located around the center of each anode pixel one-by-one. The signal of the MCP-PMT was amplified by 2, 27 or 35 db depending on the high voltage and then it was divided to be read both by a CAMAC ADC and TDC. The signal for the TDC was amplified additionally by 23 db to detect even a very small signal when the MCP-PMT gain was as small as.5 1 6, and it was discriminated at a threshold of 2 mv. The high voltage dependence was examined at seven different high voltages which correspond to the MCP-PMT gain of roughly.5-4 1 6. The high voltage means the one applied to the photocathode. It was divided up by a series of resistors into the four electrodes on the both faces of each MCP. The division ratio was 1:5:5:5:3 in this setup. The measurement was fully automated and the performance of all the MCP-PMTs was comprehended systematically. The absolute QE of the MCP-PMT (QE PMT ) was measured by using light from a xenon lamp as follows: QE PMT = I PMT I PD QE PD, (3.1) where I PMT is the photocathode current without amplification by the MCPs measured by a picoammeter, I PD is the current from a reference silicon photodiode measured by the same picoammeter and QE PD is the absolute QE of the photodiode which has been measured with a precision of 1.7% or better. To measure the QE as a function of the wavelength and the position over the photocathode, the xenon lamp was followed by a monochromator, a sharp cut filter to cut stray light, a variable neutral density filter to tune the light intensity and double slits to make a 1 mm diameter light spot on the MCP-PMT. The MCP-PMT was set on a moving stage and thus the light spot scanned the photocathode. The photodiode was fixed on the moving stage alongside of the MCP-PMT and it was moved onto the light spot every time the wavelength was changed. The measurement was also done automatically and systematically for every MCP-PMT with this setup. 3.2 Results of the measurement The gain of the MCP-PMT is defined as the mean of the output charge distribution. As shown in Fig. 1 (left) the gain (G) increases as an exponential function of the high voltage (HV ): G = exp(a HV + b), (3.2) where a and b are parameters to be determined by fitting this function to the data. The gain slope, a, is different between the conventional and ALD-MCP-PMTs as shown in Fig. 1 (right); the ALD- MCP-PMT has larger gain than the conventional one at the same high voltage. This is due to the fact that the secondary electron yield of the ALD-MCP is higher than the conventional one. 3

) 6 gain ( 1 4 3 χ 2 / ndf.7955 / 5 Constant 17.39 ±.9785 Slope.676 ±.3748 8 6 Conventional ALD 2 4 1 2 25 26 27 HV (V).2.4.6.8.1 gain slope Figure 1: (Left) Gain as a function of the high voltage for one of the MCP-PMT channels. An exponential function fitted to the data is superimposed. (Right) Distribution of the gain slope for the conventional (hatched histogram) and ALD-MCP-PMTs (dotted histogram). Each entry in this plot corresponds to one MCP-PMT or the average of 16 channels. 4 3 2 1 Entries 2459 Mean 2.52 RMS 172.2 χ 2 / ndf 5.12 / 28 Constant 411.8 ± 14.7 Mean 38.43 ± 1.35 Sigma 41.77 ± 1.48 Constant2 53.75 ± 5.29 Mean2 7.31 ± 8.59 Sigma2 132.7 ± 5.7 5 5 1 15 time (ps) Figure 2: TDC distribution for single photons for one of the conventional-mcp-pmt channels at a high voltage of 334 V. A double Gaussian fitted to the data is superimposed. TTS (ps) 1 8 6 4 2 6 gain ( 1 ).5 1 1.5 2 2.5 3 29 3 31 32 33 HV (V) Figure 3: TTS of one of the conventional-mcp- PMT channels as a function of the high voltage. Another axis on the top indicates the gain of the MCP-PMT. A TDC distribution for single photons after time-walk correction is shown in Fig. 2 for one of the conventional-mcp-pmt channels. There is a long tail on the right side of the peak. It is due to recoil of the photoelectron on the first MCP surface [12]. A double Gaussian is fitted to the TDC distribution and the standard deviation of the primary Gaussian is defined as the TTS. For this channel, the TTS is 29.5 ps after subtracting the laser pulse width ( 17 ps) and the electronics jitter ( 24.2 ps). The TTS of all the other MCP-PMTs was measured to be about 3 ps. The TTS is nearly independent of the high voltage or the gain down to.5 1 6 as shown in Fig. 3. It indicates that the secondary electron yield is nearly constant around 17 V for the conventional- MCP and around 13 V for the ALD-MCP, which corresponds to the potential difference between the photocathode and the electrode on the first MCP surface, provided that the TTS depends mainly on the statistics of the secondary electrons at the first multiplication of the photoelectron. The relative collection efficiency of the MCP-PMT is measured by counting the number of 4

1 Conventional 25 Conventional 8 ALD 2 ALD 6 15 4 1 2 5.2.4.6.8 1 1.2 1.4 1.6 1.8 2 collection efficiency (a.u.) Figure 4: Relative collection efficiency for all the conventional (hatched histogram) and ALD- MCP-PMTs (dotted histogram). 2 22 24 26 28 3 32 34 36 38 QE (%) Figure 5: QE at 36 nm for all the conventional (hatched histogram) and ALD-MCP-PMTs (dotted histogram) except those whose peak QE is less than 24%. TDC hits relative to the one of the reference PMT. The PMT-by-PMT collection efficiency is shown in Fig. 4. The collection efficiency of the ALD-MCP-PMTs is higher by about 15% than the conventional ones. A comparison of the TDC distributions normalized to the number of photoelectrons between the conventional and ALD-MCP-PMTs reveals that the difference of the collection efficiency appears in the tail made by the recoil photoelectrons on the first MCP surface. Namely the recoil photoelectrons are detectable with higher efficiency for the ALD-MCP as the secondary electron yield of the ALD-MCP is higher than the one of the conventional-mcp. The QE was measured at 18 18 positions including the peripheral non-active area and at 2 wavelengths from 28 nm to 66 nm. For most of the MCP-PMTs, the QE distributes uniformly over the photocathode and peaks at 36 nm. The QE at 36 nm for all the MCP-PMTs except those whose peak QE is less than 24% is shown in Fig. 5. The average QE of the conventional and ALD-MCP-PMTs is 28.1% and 29.1%, respectively, at 36 nm. The maximum QE among them is 35.9% at 36 nm. The two ALD-MCP-PMTs whose QE is less than 24% at 36 nm have the peak QE at 42 nm. 4. Extension of the MCP-PMT lifetime As the amount of outgassing and the QE degradation relate to the integrated output charge, the lifetime of the MCP-PMT is defined by the integrated output charge per photocathode area at which the QE drops by 2% of the beginning. During the mass production, some MCP-PMTs were sampled for the lifetime measurement. The measured lifetime of the conventional and ALD-MCP- PMTs was 1.1 C/cm 2 and 8.6 C/cm 2 on average, respectively. However the output charge due to beam backgrounds in Belle II was predicted by a Monte Carlo simulation as 3 C/cm 2 /5 ab 1 when the gain of the MCP-PMT was 5 1 5. Therefore the conventional-mcp-pmts would need to be replaced at some point. Even for the ALD-MCP-PMT, the lifetime is not sufficient for Belle II as the measured lifetime ranged down to 3.2 C/cm 2 at the minimum. Thus extension of the ALD- MCP-PMT lifetime was demanded. 5

relative QE 1.2 1.8.6.4.2 YH23 YH25 YH26 2 4 6 8 1 12 2 output charge (C/cm ) Figure 6: Relative QE as a function of the integrated output charge for three ALD-MCP-PMT samples produced with Method C. The dashed line represents the expected curve for the lifetime of 8.6 C/cm 2. We tried six methods of process in the ALD-MCP-PMT production in order to extend the lifetime and measured the lifetime of several samples for each method. Our criterion for determining whether the method is effective in terms of the lifetime extension is that the measured lifetime is longer than the average lifetime of the normal ALD-MCP-PMTs. The lifetime is derived from the relative QE as a function of the integrated output charge. In our setup for the lifetime measurement, eight MCP-PMTs were illuminated at once with a pulsed LED light at 1 khz and the output charge of each MCP-PMT was measured by a CAMAC ADC. Once a day or so, the LED was turned off to measure the relative QE. The relative QE at 4 nm was measured by counting the number of TDC hits for single photons from a pico-second pulse laser. The laser intensity was calibrated by a reference PMT, whose high voltage was turned off during the LED illumination. The gain of the MCP-PMTs was set at about 2 1 6. Among the six methods, three (called Method A, B and C hereafter) were found to be promising; the lifetime of every sample with these three methods (four, four and three samples for Method A, B and C, respectively) was longer than 8.6 C/cm 2. Especially no QE degradation was found for the three samples of Method C, which also included Method A and B, up to 4.9, 11.2 and 12.6 C/cm 2, respectively, as shown in Fig. 6. 5. Conclusion Single photon detection with a high efficiency and a time resolution better than 5 ps is one of the most important keys to realize the novel particle identification device, the TOP counter, in Belle II. We succeeded in development and mass production of the square-shaped MCP-PMT which has the QE at 36 nm greater than 28% on average and the TTS about 3 ps. Our systematic measurement of all the MCP-PMTs revealed that the high voltage dependence of the gain and the collection efficiency are different between the conventional and ALD-MCP- PMTs. This difference originates from the higher secondary electron yield of the ALD-MCP. It can also be seen in the TDC distribution; the tail of the distribution due to the recoil of the photoelectron is larger for the ALD-MCP-PMT. 6

We also succeeded in extending the lifetime of the ALD-MCP-PMT by applying the three new methods of production process. The lifetime of all the eleven samples for these methods was measured to be longer than 8.6 C/cm 2, or the average lifetime of the normal ALD-MCP- PMTs. Especially the three samples produced with all the three methods combined showed no QE degradation up to 4.9, 11.2 and 12.6 C/cm 2, respectively. Acknowledgement This work was supported by MEXT Grant-in-Aid for Scientific Research on Innovative Areas Elucidation of New Hadrons with a Variety of Flavors. References [1] M. Akatsu, et al., Time-of-propagation Cherenkov counter for particle identification, Nucl. Instr. and Meth. A 44 (2) 124. [2] T. Oshima, Time-Of-Propagation Counter - A New Cherenkov Ring Imaging Detector, ICFA Instrumentation Bulletin 2 (2) 2. [3], For the Belle II PID Group, Design and performance study of the TOP counter, in proceedings of Vienna Conference on Instrumentation 213, Nucl. Instr. and Meth. A 732 (213) 357. [4] T. Abe, et al., Belle II Technical Design Report, KEK-REPORT-21-1, 21. [5] M. Akatsu, et al., MCP-PMT timing property for single photons, Nucl. Instr. and Meth. A 528 (24) 763. [6] Y. Enari, et al., Cross-talk of a multi-anode PMT and attainment of a σ 1 ps TOF counter, Nucl. Instr. and Meth. A 547 (25) 49. [7] K. Inami, et al., Cross-talk suppressed multi-anode MCP-PMT, Nucl. Instr. and Meth. A 592 (28) 247. [8] N. Kishimoto, et al., Lifetime of MCP-PMT, Nucl. Instr. and Meth. A 564 (26) 24. [9] T. Jinno, et al., Lifetime-extended MCP-PMT Nucl. Instr. and Meth. A 629 (211) 111. [1], For the Belle II PID Group, Development and production of the MCP-PMT for the Belle II TOP counter, in proceedings of the 8th International Workshop on Ring Imaging Cherenkov Detectors, Nucl. Instr. and Meth. A 766 (214) 148. [11] S.M. George, Atomic Layer Deposition: An Overview, Chem. Rev. 21, 11, 111. [12] C. Field, et al., Development of photon detectors for a fast focusing DIRC, in proceedings of the 5th international Workshop on Ring Imaging Detectors, Nucl. Instr. and Meth. A 553 (25) 96. 7