Hristina Nikolova, Miguel Angel Aguirre, Montserrat Hidalgo and Antonio Canals. 5-6 June 2012, Plovdiv, Bulgaria. 5-6 June 2012, Plovdiv, Bulgaria

Similar documents
Green Sample Preparation Techniques for Chromatographic Determination of Small Organic Compounds

Basic Digestion Principles

LIBSlab ANALYZERS ANALYZERS

Atomic Absorption Spectrometer ZEEnit P series

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Outline. LIBS Background. LIBS Developments. LIBS Overview. Atomic Emission Spectroscopy

Atomic Spectroscopy AA/ICP/ICPMS:

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

Advanced Analytical Microextraction Techniques and There Applications: A Review

Laser Ablation for Chemical Analysis: 50 Years. Rick Russo Laser Damage Boulder, CA September 25, 2012

SUPPORTING INFORMATION. A New Approach for the Surface Enhanced Resonance Raman Scattering (SERRS)

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Determination of Iron by Dispersive Liquid-Liquid Microextraction Procedure in Environmental Samples

Quantitative Analysis of Carbon Content in Bituminous Coal by Laser-Induced Breakdown Spectroscopy Using UV Laser Radiation

Supporting Information

Behavior and Energy States of Photogenerated Charge Carriers

Liquid-phase microextraction

high temp ( K) Chapter 20: Atomic Spectroscopy

PAL SPME Arrow The Better SPME

PRINCIPLE OF ICP- AES

PAL SPME Arrow The Better SPME

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Elemental analysis of river sediment using the Agilent 4200 MP-AES

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Chemical Analysis Problem

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Supplementary information for Organically doped palladium: a highly efficient catalyst for electroreduction of CO 2 to methanol

Supporting Information

Research Article Use of Dispersive Liquid-Liquid Microextraction and UV-Vis Spectrophotometry for the Determination of Cadmium in Water Samples

Some Recent Developments in Headspace Gas Chromatography

Ablation Dynamics of Tin Micro-Droplet Target for LPP-based EUV light Source

Analysis of domestic sludge using the Agilent 4200 MP-AES

Environmental impact. Improve resource efficiency. Quality secondary raw materials. Pollution. CO 2 emission. Biodiversity. Policy and regulations

Supporting Information

Spectroscopy Problem Set February 22, 2018

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

ICP-OES Application Note Number 35

Ionization Techniques Part IV

OES - Optical Emission Spectrometer 2000

Chem 155 Quiz 3 Review Topics: Quiz 3 outline

Surfactant-Free Solution Synthesis of Fluorescent Platinum Subnanoclusters

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Carbon powder modification. Preparation of NS1, NS2, NS3 and NS4.

ICP-Mass Spectrometer

Atomic Absorption Spectroscopy

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

a. An emission line as close as possible to the analyte resonance line

Electronic Supplementary Information. Ultrafast Charge Separation in Supramolecular Tetrapyrrole- Graphene Hybrids

novaa 800 D Atomic Absorption Spectrometer

Sampling, Storage and Pre-Treatment Techniques

CH. 21 Atomic Spectroscopy

Fragrances Sampling and Analysis

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

*Author for Correspondence

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

Synthesis of 2 ) Structures by Small Molecule-Assisted Nucleation for Plasmon-Enhanced Photocatalytic Activity

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Xiufang Chen, Jinshui Zhang, Xianzhi Fu, Markus Antonietti, and Xinchen Wang*

9/13/10. Each spectral line is characteristic of an individual energy transition

Fundamental investigation on CO 2 laser-produced Sn plasma for an EUVL source

Ch 313 FINAL EXAM OUTLINE Spring 2010

A novel AgIO 4 semiconductor with ultrahigh activity in photodegradation of organic dyes: insights into the photosensitization mechanism

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Analytical Chemistry. The Analytical Process Sample Preparation. Dr. A. Jesorka, 6112,

Sub-10-nm Au-Pt-Pd Alloy Trimetallic Nanoparticles with. High Oxidation-Resistant Property as Efficient and Durable

Product Descriptions and Offerings

Gas Sensors and Solar Water Splitting. Yang Xu

UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

Low cost, rapid and in situ accurate quantification of chloramines and ammonia

Determination the elemental composition of soil samples

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Optimization of laser-produced plasma light sources for EUV lithography

Test Method: CPSC-CH-E

Supporting Information. Facile design of phase separation for microfluidic. droplet-based liquid phase microextraction as a front end to

Chem 310 rd. 3 Homework Set Answers

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Laser-produced extreme ultraviolet (EUV) light source plasma for the next generation lithography application

AIMALYTICAL CHEMISTRY

Fourier Transform Infrared Spectrometry Prelab Last modified: June 17, 2014

L E A. Laser Elemental Analyzer

Hydrogen Bonded Dimer Stacking Induced Emission of Amino-Benzoic Acid Compounds

ADVANCES IN ANALYTICAL MICROEXTRACTION METHODS TOWARDS GREEN CHEMISTRY

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

GC/MS Application Note

Evaluation of laser-induced breakdown spectroscopy (LIBS) as a new in situ chemical sensing technique for the deep ocean

LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION

CARBON NANOTUBE ANALYSIS USING THE TSI LIBS DESKTOP ANALYZER

HYPER-RAYLEIGH SCATTERING AND SURFACE-ENHANCED RAMAN SCATTERING STUDIES OF PLATINUM NANOPARTICLE SUSPENSIONS

Optical Emission Spectroscopy of Diffuse Coplanar Surface Barrier Discharge

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Transcription:

Green analytical chemistry: Trace elemental analysis on water samples by liquid-liquid microextration (LLME)-laser- induced breakdown spectroscopy (LIBS) Hristina Nikolova, Miguel Angel Aguirre, Montserrat Hidalgo and Antonio Canals

Overview Introduction Green chemistry Green analytical chemistry Sample preparation Miniaturization on sample preparation Liquid-liquid microextraction (LLME) Detection techniques for LLME Laser-induced breakdown spectroscopy (LIBS) for trace elemental analysis Evaluating LIBS for the analysis of Mn in microdroplets Direct microdroplets on aluminium substrates Testing the combination of LLME-LIBS: preliminary results

Introduction

Introduction Green Chemistry Sustainable development protection of the environment a form of development that meets the needs of the present without compromising the ability of future generations to meet their own needs

Introduction Green Analytical Chemistry(I) it is an unfortunate irony that environmental analytical methods often contribute to further environmental problems through the chemicals used in the analysis From : P.T. Anastas, Crit. Rev. Anal. Chem., 29(3), 167-175 (1999)

Introduction Green Analytical Chemistry(II) The goal of Green Analytical Chemistry is to use analytical procedures that generate less hazardous waste and that are safer to use and more benign to the environment

Twelve Principles of Green Chemistry on Analytical Chemistry Introduction The elimination (or at least, the significant reduction) of reagents, particularly organic solvents, from analytical procedures Reduced emissions of vapours and gases, as well as liquid and solid wastes generated in analytical laboratories The elimination of highly toxic and/or eco-toxic reagents from analytical procedures (e.g., the substitution of benzene with other solvents) Reduced labour and energy consumption of analytical procedures (per single analyte) Reduced time gap between sampling and the desired information becoming available (i.e., real time analysis) From: M. Tobiszewski, A. Mechlinska, J. Namiesnik, Chem. Soc. Rev., 39, 2869 2878 (21)

Introduction Challenges in Green Analytical Chemistry From: M.Tobiszewski, A. Mechlinska, J. Namiesnik, Chem. Soc. Rev., 39, 2869 2878 (21)

Introduction

Sample preparation

Sample preparation Sample conditioning: Adapt the physical or chemical state to the requirements of the instrument. Removal of interfering species: Masking or separation techniques (e.g., adsorption, absorption, dialysis, precipitation, supercritical fluid extraction, liquid-liquid extraction (LLE), solid phase extraction (SPE), etc.) Additional operations: Dilution, (pre)concentration, chemical transformations and derivatization, etc.

Sample preparation Sample preparation is the Achilles Heel of total analytical process!!!!

1 9 8 7 6 5 4 3 Sample preparation Sample preparation Publications Solid phase extraction Microextraction/miniaturization Liquid-liquid extraction Heating Digestion Mixing Derivatization Automation Centrifugation Filtration Enrichment Membrane extraction/dialysis Drying Precipitation Homogenization Stirring Weighing Headspace Purge-trap Evaporation Organic extraction Soxhlet extraction Solid-liquid extraction Supercritical fluid extraction Cooling Distilation Thermal desorption Lixiviation Combustion 2 1 (Source: SciFinder Scolar 21)

Sample preparation Sample preparation and miniaturization N. of publicat tions/year 6 5 4 3 2 1 25 26 27 28 29 21 211 Year Source: SciFinder (26/5/212)

Classification of main extraction techniques: Headspace extraction techniques: Static Headspace (SH) Purge & Trap (dynamic headspace, P&T) Membrane extraction techniques Sorptive extraction techniques: Solid-phase extraction (SPE) Stir bar sorptive extraction (SBSE) Solid-phase microextraction (SPME) Solvent extraction techniques: Liquid-liquid extraction (LLE) Liquid-liquid microextraction (LLME) Hollow fiber-liquid phase microextraction (HF-LPME) Single drop microextraction (SDME) Dispersive liquid-liquid microextraction (DLLME) Sample preparation

SDME Sample preparation

Detection techniques for LLME

Detection techniques for LLME Detection techniques for LLME Organic analytes HPLC, GC, CE before FID, ECD, UV-Vis, MS, etc. Inorganic analytes ETAAS, ETV-ICP-OES/MS, others (FAAS, CV-AFS, ICP-MS and ICP-OES)

Detection techniques for LLME THIS IS NOT PORTABLE INSTRUMENTATION!!!

Detection techniques for LLME Laser-induced breakdown spectroscopy (LIBS) for trace elemental analysis

Detection techniques for LLME LIBS Disadvantage: low sensitivity high LODs Advantages: Multielement analysis Fast Portability Easy to automate Capability to analyze very small quantities (microdroplets) of sample LLME and LIBS could be combined for trace metal analysis

2x1 3 1x1 3 5x1 2 21 212 214 216 218 22 222 Wavelength (A) Detection techniques for LLME Evaluating LIBS for the analysis of Mn in microdroplets LIBS system ns Nd:YAG laser (164 nm) Avantes modular spectrometer (Czerny-turner configuration + CCD - covering from 3 nm 4 nm) Delay system (pulse generators) for acquisition time delay control Oscilloscope and photodiode to monitor plasma formation and acquisition delay Oscilloscope Photodiode PC Avantes spectrometer Optic fiber Micro-sample Q-Switch Pulse generator Nd:YAG Laser Flash lamp Pulse generator Experimental procedure Synthetic samples with different Mn 2+ concentration were prepared Microvolumes of the prepared samples were analyzed by using two different LIBS experimental strategies: Analysis by direct laser irradiation of microdroplets Analysis by laser irradiation of microdroplets on a metallic (aluminium) substrate

Direct microdroplets on aluminium substrates Experimental procedure 1 µl microdroplets were placed on an aluminium substrate and left to dry for 15 minutes Laser radiation was focused on the dried microdroplet to create the LIBS plasma Plasma emission was detected by the Avantes spectrometer Five spectra were taken for each single droplet. Spectra of one single droplet were averaged Several laser shots on a single, dried, 1 µl sample droplet Results Sample microdroplets having different Mn 2+ concentration Aluminium substrate Since laser radiation can be focused on a extremely low sample area, this configuration allows several replicate measurements to be carried out in a single microdroplet. LIBS emission signal markedly improves when microdroplets are analyzed by using aluminium substrates. Detection techniques for LLME 15 min Intensity (counts) 6x1 3 5x1 3 4x1 3 3x1 3 2x1 3 1x1 3 Laser radiation Focusing lens Plasma emission to AvaSpec Mn II (259.37nm).1% Mn micro-droplet on aluminum substrate 1% Mn direct analysis of the micro-droplet 258 259 26 261 262 Wavelength (nm) Direct analysis of microdroplets vs. the use of aluminium substrates Orange spectrum corresponds to an analyte concentration 1 times lower than that of green spectrum Mn II (26.57nm)

Detection techniques for LLME Results Direct microdroplets on aluminium substrates Higher reproducibility and better linearity (R 2 =.9969 compared to direct analysis of droplets Limit of detection was found to be 6x1-4 % of Mn (6 ppm) Considering that microextraction methodologies can lead to micro-volumes of extractants and high enrichment factors (more than 2, in some cases) (Mn II) m /(Al I) m.4.3.2.1. y = 321.22x +.3 R 2 =.9969 2x1-4 4x1-4 6x1-4 8x1-4 1x1-3 Mn (%, w/w) Analysis of microdroplets on aluminium substrates (Al was used as internal standard) LIBS analysis of microdroplets on solid substrates appears to be a promising alternative to be combined with LLME methodologies for trace elemental (a) analysis Intensity (counts) 1 ppm Mn Blank (1% Triton) 258 259 26 261 262 Wavelength (nm) LIBS signal of a 1 ppm Mn sample

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results After SDME Drying LIBS analysis Spectrometer Mirror Focusing lens Optical system LIBS plasma

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Univariate optimization Variables Molar ratio (APDC/analytes) ph Extraction time Stirring speed Droplet volume

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Variable Molar ratio (APDC/analytes) 8 7 6 5 4 3 2 1 CuI 324.754 Constants 5 1 Molar ratio ph = 1 Extraction time = 1 min Stirring speed = 17 r.p.m. Droplet volume = 5 µl

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results 1 9 8 7 6 5 4 3 2 1 ZnII 26.2 5 1 Molar ratio 5 45 4 35 3 25 2 15 1 5 MnII 259.373 5 1 Molar ratio 8 7 6 5 4 3 2 1 CuI 324.754 5 1 Molar ratio 35 NiI 352.454 14 CrI 357.869 3 12 25 2 15 1 1 8 6 4 5 2 5 1 Molar ratio 5 1 Molar ratio

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Variable ph 7 6 CuI 324.754 Constants Molar ratio (APDC/analytes) = 5 Extraction time = 1 min Stirring speed = 17 r.p.m. Droplet volume = 5 µl 5 4 3 2 1 5 1 15 ph

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results 7 ZnII 26.2 12 MnII 259.373 7 CuI 324.754 6 1 6 5 4 3 2 8 6 4 5 4 3 2 1 2 1 5 1 15 ph 5 1 15 ph 5 1 15 ph 12 NiI 352.454 7 CrI 357.869 1 8 6 4 2 6 5 4 3 ph 1 2 ph 12 1 5 1 15 ph 5 1 15 ph

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Variable Extraction time 4 35 3 25 2 15 1 5 CuI 324.754 Constants 5 1 15 Time (min) Molar ratio (APDC/analytes) = 5 ph = 1 Stirring speed = 17 r.p.m. Droplet volume = 5 µl

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results 12 ZnII 26.2 8 MnII 259.373 4 CuI 324.754 1 8 6 4 2 7 6 5 4 3 2 1 35 3 25 2 15 1 5 5 1 15 Time (min) 5 1 15 Time (min) 5 1 15 Time (min) 18 NiI 352.454 18 CrI 357.869 16 16 14 14 12 1 8 6 4 12 1 8 6 4 2 2 5 1 15 5 1 15 Time (min) Time (min)

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Variable Stirring speed 7 6 CuI 324.754 Constants Molar ratio (APDC/analytes) = 5 ph = 1 Extraction time = 1 min Droplet volume = 5 µl 5 4 3 2 1 5 1 15 2 rpm

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results 25 ZnII 26.2 7 MnII 259.373 7 CuI 324.754 2 15 1 5 6 5 4 3 2 1 6 5 4 3 2 1 1 2 rpm 1 2 rpm 1 2 rpm 6 5 4 3 2 1 NiI 352.454 1 2 2 18 16 14 12 1 8 6 4 2 CrI 357.869 1 2 rpm rpm

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Variable Droplet volume 4 35 3 25 2 15 1 5 CuI 324.754 Constants 5 1 15 Droplet volume (µl) Molar ratio (APDC/analytes) = 5 ph = 1 Extraction time = 1 min Stirring speed = 17 r.p.m.

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results 25 ZnII 26.2 7 MnII 259.373 4 CuI 324.754 2 15 1 5 6 5 4 3 2 1 35 3 25 2 15 1 5 5 1 15 Droplet volume (µl) 5 1 15 Droplet volume (µl) 5 1 15 Droplet volume (µl) 7 NiI 352.454 14 CrI 357.869 6 12 5 4 3 2 1 8 6 4 1 2 5 1 15 5 1 15 Droplet volume (µl) Droplet volume (µl)

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Optimized values Molar ratio (APDC/analytes) = 5 ph = 1 Extraction time = 1 min Stirring speed = 17 r.p.m. Droplet volume = 7.5 µl

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results ZnII 26.2 nm With SDME 1 5 Blank ppb Without SDME

Detection techniques for LLME Testing the combination LLME-LIBS: preliminary results Without SDME With SDME Emission line (nm) Slope (ppb -1 ) LOD (ppb) Slope (ppb -1 ) LOD (ppb) ZnII (26.2) 7.6±.4 171 54±3 23 MnII (259.373) 29±4 427 59±4 31 CuI (324.754) 26±5 141 55±5 54 NiI (352.454) 2.±.2 149 11.3±.6 67 CrI (357.869) 7.±1. 143 17.6±1.2 5

Conclusions Conclusions I. For the first time, the capability for elemental analysis of LLME + LIBSAcknowledgments has been experimentally proved II. Nevertheless, much work is still needed in order to definitively assess the analytical capabilities of LIBS to be coupled with several microextraction methodologies

Future work Future work Study and optimization of the best solid substrate to be used as solid-sample holder Study of the influence of the extraction solvent (concentration and nature surfactants, ionic liquids, organic solvents, etc.) on LIBS signal Study of the double pulse LIBS methodology as a mean to obtain further emission intensity and S/N enhancement Miniaturized/portable LIBS system

Acknowledgements Acknowledgements I. The Spanish Government (projects CTQ28-673-C2-1 and CTQ211-23968) Acknowledgments II. NSF of Bulgaria (GAMA project DO 2-7) III. European Union Seventh Framework Programme (FP7). Program Capacities (REGPOT). BioSupport project

The SP-BG team

The BG-SP team

Thank you for your attention