Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

Similar documents
AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

Carbon (Organic, and Inorganic)

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Fusion UV/Persulfate TOC Analyzer

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

A Spectrophotometric Analysis of Calcium in Cereal

Hydra-C Application Note: 1076

Fusion UV/Persulfate TOC Analyzer

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Total Organic Carbon, Total Nitrogen

A New On-line Cyanide Analyzer for Measurement of Cyanide in Hydrometallurgical Processing of Precious Metal Ores

Examining the Role of TOC Analyzers in the Pharmaceutical Laboratory

Advanced technics in the. (TIC/TOC/TNb)

Basic Digestion Principles

2. Pharmaceutical industry

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Elemental Analysis: NCS characterization of paper

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

ICP-OES Application Note Number 35

TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:

13. CARBON AND CARBONATE ANALYSES, LEG 9

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Theory of Headspace Sampling

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

United States EPA Method 415.3

IDENTIFICATION TESTS FOR DURACOR TABLETS

Application Note No. 310/2018

Analysis of BTEX in Natural Water with SPME

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

SST3005 Fundamentals of Soil Science LAB 5 LABORATORY DETERMINATION OF SOIL TEXTURE: MECHANICAL ANALYSIS

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

METHOD 3600C CLEANUP

ISO 8245 INTERNATIONAL STANDARD. Water quality Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

ENVIRONMENTAL CHEMICAL ANALYSIS

Quantification of total nitrogen according to the Dumas method (Musts and Wines) (Resolution Oeno 13/2002)

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Test Method: CPSC-CH-E

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Organic Carbon, Total (Low Level) (UV Promoted, Persulfate Oxidation) CAS # Total Organic Carbon TOC C

Determination of Caffeine by HPLC

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Determination of Carbon d13c isotopic composition from DIC samples

Glossary of Common Laboratory Terms

and Environmental Science Centre

AGrignard reaction, in which a reactant, A, is coupled with phenyl magnesium chloride, is used to

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Dr. Jonathan Gutow Fall Looking for PCBs in Water or Can PCBs Wash out of Landfills and Contaminate Ground Water?

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve

PREPARATION OF ACTIVATED CARBON FROM THE BY-PRODUCTS OF AGRICULTURAL INDUSTRY

PHENOL OXIDASE AND PEROXIDASE ASSAYS CENTER FOR DEAD PLANT STUDIES 15 September 2000

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

STANDARD OPERATING PROCEDURES

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

BAE 820 Physical Principles of Environmental Systems

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

INTERNATIONAL CHEMISTRY TESTING. 258 Main Street- Suite 311- Milford, MA Tel: Fax:

ALLOWAY METHOD OUTLINE

Biofuels Series. Application Note 301LS RAPID MEASUREMENT OF XYLOSE AND GLUCOSE MONITORING CORN STOVER FERMENTATION IN BIOETHANOL PRODUCTION

Maximizing Sample Throughput In Purge And Trap Analysis

6. Extraction. A. Background. (a) (b) (c) Figure 1. Mixing of Solvents

Delvin DeBoer, Ph.D., PE. MN/ND/SD SWTW April 29, 2014 OUTLINE

Automating Wet Chemical Analysis

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

REMEDIATION OF SALT IMPACTED GROUNDWATER WITH ELECTROKINETICS. Paper by: Sean Kelly, Rick Churko, Sean Frisky, Anjum Mullick, Stuart Torr.

METHOD 8000A GAS CHROMATOGRAPHY

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

SOIL ORGANIC CONTENT USING UV-VIS METHOD

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Thermochemistry: Calorimetry and Hess s Law

Isothermal and Nonisothermal Kinetic Analyses of Mahogany Oil Shale with TGA

Automation of Routine Microplate Pipetting and Dispensing

9/13/10. Each spectral line is characteristic of an individual energy transition

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

The Role of Proficiency Tests in the Estimation of Measurement Uncertainty of PCDD/PCDF and PCB Determination by Isotope Dilution Methods

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

Application Note 032

METHOD 3600B CLEANUP

Atomization. In Flame Emission

The art of elemental analysis

Elements and Their Oxides

Leaching Environmental Assessment Framework Pre-Method 1313: Liquid-Solid Partitioning as a Function of Eluate ph using a Parallel Batch Procedure

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

Development of a Method to Determine Microbiologically Generated Mercury Vapor and Organomercury in CCBs

Certificate of Analysis

Testing the Ammonia Content of Class F Fly Ash

Name Partner Lab Section M Tu W Th F Chemistry 130 Experiment 6: Titration and Analysis

Ashley Unit Conversions and Matter Chem 101

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Sulfotepp impurities in Chlorpyrifos EC formulations

Transcription:

Application Note 35140710 Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications Keywords 1030S Solids Module Aurora 1030 TOC Analyzer High Temperature Catalytic Oxidation (HTCO) SW 846 Method 9060A ISO 10694: 1995 Introduction Total Organic Carbon (TOC) analysis of solid samples provides useful information for environmental applications including waste management, biomass conversion, and carbon cycle research. TOC analysis is also used to perform quality control (QC) checks on industrial materials such as fly ash, cement, and kaolin. The heterogeneous composition of environmental samples poses an analytical challenge. Analytical methods (SW 846 Method 9060A and ISO 10694:1995) (1,2) describe matrix conditioning steps (e.g., sample drying, grinding, and pre-acidification to remove inorganic carbon) that are often required to ensure complete oxidation of organic matter and an accurate TOC value is obtained. Existing techniques for TOC analysis of solids introduce the sample into a furnace for combustion. The resulting combustion gases are swept by a carrier gas stream from the furnace directly into a detector for measurement of CO 2 and calculation of the carbon content. This approach limits the sample mass that can be efficiently combusted and the measurable carbon range of samples. As a consequence, instruments operating on this principle are prone to over- and/or under-ranging the carbon content of materials being tested. This application note details design and performance characteristics of a new sample preparation module for TOC analysis of solid samples that incorporates a gas sampling device to collect all CO 2 gas from combustion of each sample prior to transfer of a gas aliquot for measurement. Analytical results obtained on three Standard Reference Materials (SRMs), and humic acid, fly ash, and cellulose samples are reported. Presented at the 2010 Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Orlando, Florida March 1 March 5, 2010 Instrument Description The 1030S Solids Module is a sample preparation module that interfaces to an Aurora 1030 TOC Analyzer enabling analysis of the total organic carbon (TOC) or total carbon (TC) content in solid materials (Figure 1). The 1030S module oxidizes and converts the organic compounds in solid samples into CO 2 which is collected in a gas sampling device. When the combustion cycle is completed, CO 2 gas is transferred to the Aurora 1030 TOC analyzer for measurement by a non-dispersive infrared (NDIR) detector.

Figure 1. 1030S Solids Module and Aurora 1030 TOC Analyzer Solid samples to be analyzed are manually transferred and weighed in quartz crucibles. Two different volume crucibles are available (1 ml and 2.5 ml) to address differences in the mass, bulk density, and anticipated carbon content of samples. These crucibles have either a solid bottom or a small diameter hole in the bottom. Principle of Operation The 1030S Solids Module supports two basic modes of operation for determining either the TOC or TC content of samples. The principal difference between the two modes lies in how the total inorganic carbon (TIC) content of samples is addressed. Accurate organic carbon analysis requires the capability to differentiate between inorganic and organic forms of carbon present in samples. Inorganic carbon is almost always present as carbonate minerals, either as calcium carbonate (calcite and/or aragonite), or as calcium magnesium carbonate (dolomite). All carbonate minerals are readily soluble in heated acid solution providing a means of distinguishing inorganic and organic carbon. Operation for Total Organic Carbon Analysis Determination of the TOC content requires a pre-acidification step to remove the TIC content of the sample prior to combustion in the 1030S. The solid sample to be analyzed is manually transferred and weighed in a quartz crucible. Adding acid to the crucible and heating the sample drives off CO 2 released from inorganic carbon compounds present in the sample. The crucible with the TIC-free sample is then placed on the lift mechanism and raised into combustion tube of the 1030S module. The sample is heated to 500 900 C inside the furnace. Oxygen is introduced at a steady rate for high-temperature catalytic combustion. Organic matter in the sample is oxidized and converted to CO 2 gas which is collected in a 1 L capacity gas sampling bag. When the combustion cycle is completed, an aliquot of CO 2 gas is transferred from the gas sampling bag to the Aurora 1030 TOC analyzer for measurement by a solid state nondispersive infrared (SSNDIR) detector. The result is reported as the TOC content in both mass and concentration of carbon. Analysis of combustion gas from a flexible sampling bag has advantages over direct injection to the detector. Specifically, greater control over combustion time is possible yielding an extended mass range while minimizing the effects of sample heterogeneity. Additionally, analysis of intra-sample replicates increases confidence in results. 2

Operation for Total Carbon Analysis In total carbon analysis, the pre-acidification step to remove the TIC content is not required. The sample is manually transferred and weighed into a quartz crucible and placed directly on the 1030S lift mechanism. The subsequent sample combustion, CO 2 gas collection, transfer, and analysis steps are the same performed for TOC analysis. The mass of carbon reported is the total carbon (TC) content (TIC + TOC). Experimental A validation study was conducted using Standard Reference Materials (SRMs) and samples of unknown carbon content to assess the oxidation efficiency and TOC recoveries obtained with the 1030S Solids Module. Testing unknown samples for carbon recoveries enabled assessment of both inter-sample and intra-sample (replicates drawn from the gas sampling bag) variation. The three SRMs tested were SRM 2719 Calcined Petroleum Coke (3), SRM 8704 Buffalo River Sediment (4), and SRM 2702 Inorganics in Marine Sediment (5). Other samples tested included Humic Acid and Cellulose. Two calibration ranges were required to account for differences in the carbon content of the various samples, which ranged from 3 to 100% carbon. The lower level calibration was run on a system with the 1030S module interfaced to an Aurora 1030C combustion TOC analyzer. The higher level calibration was run on a system with the 1030S module interfaced to an Aurora 1030W wet oxidation TOC analyzer. Glucose and dextrose calibration solutions were dispensed into open-holed 1 ml crucibles using a 50 μl syringe. The syringe was flushed with DI water prior to aspiration of the sample to prevent carryover. Solid materials were weighed directly into the crucibles using a four-place balance. Quartz wool was placed in the bottom of all crucibles to help hold the samples. The crucibles were routinely conditioned to remove residual carbon and eliminate sample to sample carryover. Programming a method involves entering the sample mass, times for reaction and collection of combustion gas, and detection. The TC mode was used to analyze all samples in this study. Instrument operating conditions used for low and high level calibration settings are shown in Table 1. Table 1. Instrument Operating Conditions for Low- and High-level Calibrations Parameter 1030C TOC Analyzer Settings for Low-level Calibration 1030W TOC Analyzer Settings for High-level Calibration Reaction Vessel Standby Temperature 35 C 35 C Method TC TC Sample (Gas Volume) 2 ml 2 ml React (Combustion Time) 6 min 7 min Detect (Time) 3 min 4 min Furnace Temp 900 C 900 C Crucible Conditioning Time 1.5 1.5 Sample Bag Purge Time 20 sec 45 sec Purge Cycles 3 4 3

Table 2. 1030C and 1030W TOC Analyzer Calibration Results Calibration mg Carbon Area %RSD Low-level (1030C) Calibration Results 3 reps 0.5 7,042 0.51 1 14,898 2.73 2.5 34,603 2.81 5 66,287 2.14 10 127,460 1.67 Response Factor (RF) 0.0794 R 2 0.9990 High-level (1030W) Calibration Results 2 reps 11.1 71561 2.60 19.9 133,081 1.98 30.2 195,644 1.92 39.7 260,628 1.61 50.0 328,295 1.57 Response Factor (RF) 0.1523 R 2 0.9988 Although samples falling within the lower level calibration range only require a 4 or 5 min combustion time (data not shown), a 6 minute combustion time was used for some hard to oxidize materials to assess combustion efficiency. A 7 minute combustion time was used for samples analyzed using the high-level calibration. It should be noted that the purge times and number of purges were different for high and low level samples. At higher levels of carbon, larger purge volumes are recommended to ensure residual carbon is completely evacuated from the gas sampling bag. 4

Results and Discussion Calibration results reported in Table 2 show a linear response at low and high levels. Both calibration curves had nearly identical R 2 values of 0.9988 for the lower range and 0.9990 for the higher range. Once established, both curves were checked to ensure recoveries would be linear. The lower level calibration checks were run with 10% sucrose and 10% dextrose solutions. The high level calibration checks were run using graphite. Results showed near 100% recoveries for all check standards. Table 3. Low-level Calibration Curve Checks Mass mg %Carbon %RSD Sucrose 1 mg C 0.929 92.937 1.99 2.5 mg C 2.517 100.689 2.80 10 mg C 9.829 98.295 1.52 Dextrose 1 mg C 0.913 91.273 2.82 2.5 mg C 2.595 103.788 2.90 10 mg C 10.041 100.410 0.66 Table 4. High-level Calibration Curve Checks Mass mg %Carbon %RSD Graphite 12.1 mg C 12.719 105.12 2.59 29.8 mg C 29.977 100.53 2.00 43.9 mg C 43.213 98.43 1.58 Low level Samples Samples of known carbon values were analyzed within the calibration range. These samples included two SRM standards - Buffalo River Sediment and Inorganic Marine Sediment, a typical additional validation standard of Urea, and Calcium Carbonate, an inorganic carbon standard. Additionally, a standard from the International Humic Substances Society (IHSS), Elliott Loam Silt (6), was run to assess carbon recovery with humic acid. Recoveries better than 95% were obtained on all samples tested. Intra-sample testing, (analysis of gas replicates) resulted in better than 2% RSD on 3 replicates. Average RSDs for inter-sample testing were better than 4% on 3 samples. Variation in inter-sample results with Elliott Loam Silt were likely due to inconsistencies in sample to sample composition. Further homogenization may be necessary to achieve more consistent results. Sample Table 5. Analytical Results for Low-Level Samples %Carbon Intra-sample %RSD Inter-sample %RSD Expected %C %Recovery Urea 19.93 1.46 0.48 19.98 99.7 Buffalo River Sediment 3.24 1.47 0.55 3.35 96.8 Inorganic Marine Sediment 3.25 0.69 1.39 3.36 96.8 Calcium Carbonate 11.55 1.88 3.06 11.99 96.3 Elliot Loam Silt 2.77 0.51 3.43 2.90 95.6 5

Low-level Recoveries 100% 95% % Recovery 90% 85% 80% 75% Urea Buffalo River Sediment Inorganic Marine Sediment Calcium Carbonate Elliott Loam Silt Sample Matrix Figure 2. Low-level Recoveries High level Samples In this sampling section, samples of known and unknown carbon content were run for comparison. Calcined Petroleum Coke was used as a benchmark material for its nearly 100% Carbon content (97.06%). Elliott Loam Silt was tested to compare recoveries obtained using both high and the low level calibration ranges. Cellulose was used because it is considered the benchmark of oxidation efficiency in several protocols, including EN 1484 (7 ). Pure humic acid was also used as a test for complete oxidation because of its presence in many soil matrices. Finally, Fly Ash of an unknown carbon content was used to test the consistency of oxidation of an unknown compound. The Fly Ash material came in large chunks/fragments, a portion was crushed and ground into a fine powder using a mortar and pestle for homogeneity. Samples Table 6. Analytical Results for High-level Samples %Carbon Intra-sample %RSD Inter-sample %RSD Expected %C %Recovery Humic Acid 44.86 2.10 0.64 48.99 89.7 Calcined Petroleum Coke 96.33 1.72 1.02 97.06 99.2 Cellulose > 19 mg C 35.64 1.16 1.47 44.45 80.2 Cellulose < 19 mg C 42.10 1.71 1.87 44.45 94.7 Elliott Loam Silt 3.24 2.45 4.45 2.90 111.7 Fly Ash 40.04 0.91 1.04 unknown 6

High-level Recoveries 115% 110% 105% % Recovery 100% 95% 90% 85% 80% 75% 70% Humic Acid Calcined Petroleum Coke Cellulose >19 mg C Cellulose <19 mg C Elliott Silt Sample Matrix Figure 3. High-level Recoveries Slightly more variation was observed for carbon content tested using the higher level calibration curve. Calcined Coke Petroleum recovery was nearly at 100%. Cellulose samples showed a matrix effect where smaller masses (<19 mg C) of cellulose exhibited more effective oxidation than larger masses ( > 19 mg C). Elliott Loam Silt showed higher than expected recovery. Small variations in the calibration curve can affect low-level measurements. This can cause a positive or negative bias with masses outside the calibration range. To ensure accurate recoveries are obtained analyses must be performed within the proper range. Humic Acid showed approximately 90% recovery. Although the recovery is sufficient, the variation may be due to the fact the carbon content of humic acid is an estimated value. A true carbon value is difficult to obtain for this material even within the same sample. Accordingly, it is advisable that a SRM or other known sample be used to confirm recoveries of humic acid. While the actual carbon content of the Fly Ash was unknown, because a SRM of similar composition showed excellent recovery, the results of intra- and inter- sampling suggest high confidence in the Fly Ash values. When studying the efficiency of sampling techniques, overall intra-sampling of these materials showed excellent consistency below 2.5%RSD. Inter-sampling showed even better precision below 2%, with the exception of Elliott Loam Silt. This is most likely due to the absolute minimal recovery versus the amount of sample required for the calibration range. 7

Summary and Conclusions The results of analyses conducted using Standard Reference Materials demonstrate that the gas sampling bag in the 1030S solids module is an effective mechanism for collecting the CO 2 produced during high temperature catalytic oxidation of solid samples for TOC analysis. Total carbon recoveries obtained on low and high-level samples using two calibration ranges achieved high-levels of accuracy and precision. RSDs for intra-sample testing (analysis of gas replicates) were below 2.5%. RSDs for inter-sample testing were generally below 4% notwithstanding issues with sample homogeneity. References 1. U.S. EPA SW 846 Method 9060A, Total Organic Carbon in Soil, 1999. 2. ISO 10694: 1995 Soil Quality Determination of Organic and Total Carbon after Dry Combustion (elementary analysis) 3. Standard Reference Material 2719, Calcined Petroleum Coke, National Institute of Standards & Technology. 4. Standard Reference Material 8704, Buffalo River Sediment, National Institute of Standards & Technology. 5. Standard Reference Material 2702, Inorganics in Marine Sediment, National Institute of Standards & Technology. 6. International Humic Substances Society, Bulk Material, Elliot Loam Silt 7. EN 1484:1997 Water Analysis Guidelines for the Determination of Total Organic Carbon (TOC) and Dissolved Organic Carbon (DOC) Publication 35140710