ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

Similar documents
NEW. A class of its own. Centrifuge 5430 / 5430 R

Centrifuge 5427 R. Sample Handling Centrifuges CENTRIFUGES

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

EU-IVD Products included. The Next Benchmark. Eppendorf Centrifuge 5910 R and Centrifuge 5920 R

New: 4 liter capacity! More Capacity. Centrifuge 5920 R

473 Dew Point Hygrometer

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Homogenisation with Perfection

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

AIR COOLED CONDENSING UNIT

473 Dew Point Hygrometer

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Thermal Analysis Premium

8 Installation Equipment

LED examination luminaire VISIANO Optimal contrast viewing through LEDs in two different colour temperatures.

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

Promotion period: September 15 - December 31, Super Sale. Quality at unbeatable prices

Operating Instructions for Digital Manometer. Model: MAN-SD

PHOS 15 LED PROJECTOR

CapaciTorr HV Pumps. making innovation happen,together

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Automatic titrators, TitroMatic

ph/redox Measurement CPM 280

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ISEmax CAM40/CAS40. Technical Information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

W 9 L: Laser photoelectric switches: small, light and reliable

Endless Possibilities

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

CapaciTorr HV 200 HIGHLIGHTS

792A AC/DC Transfer Standard

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

VK2 volume flow controller Overview

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Ion-Chamber Survey Meter OD-02

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

NEW! ep Dualfilter T.I.P.S. Peak of perfection

Impedance relay and protection assemblies

Single Phase Motors Technical Datasheets

SPECTROPHOTOMETERS. Visible and UV-Visible

Color Compensation Set 1

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Recommended Hole Pattern: [mm]

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Eppendorf SmartBlock. Instructions for use

Kjeltec 2300 Analyzer Unit

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

792A AC/DC Transfer Standard

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715*

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer

NEW: 5.0 ml screw cap tube. The Missing Link. Eppendorf Tubes 5.0 ml Discover a new sample handling system

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

Bright Advance Corporation

Heraeus Megafuge 16 Heraeus Megafuge 16R

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

AC axial compact fan

Vet Photometer DP 700 Operating Manual. Version V5.9

JAPAN QUALITY. Automated Clinical Analyzer

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

User Manual VX4750 Function Generator Module

473-SHX Dew Point Mirror

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m

CTC 155 / 350 / 660 Dry-block calibrator

Sorvall ST 16 Sorvall ST 16R

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Endless Possibilities

Mason Technology Ltd

AIR COOLED CONDENSING UNIT

Moisture Analyzers.

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

WCAP-FTXX Film Capacitors

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Recommended Land Pattern: [mm]

Conductivity sensor for hygienic applications

Z7A. Load cells. Special features. Data sheet. Wiring code

Mason Technology Ltd

Karl-Fischer Titration the method for determining water

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

LABSONIC The convenient ultrasonic homogenizer for your laboratory

MDR 3000 Professional Professional Moving Die Rheometer. Testing instruments. Laboratory Equipment. Software systems. Service.

AC axial compact fan

LABORATORY LINE. REACTRON RT 1 and RT 2. Reaction and mixing processes at a laboratory level, modular design laboratory reactors

3B SCIENTIFIC PHYSICS

PARTS MANUAL 2 INCH CHIPPER/SHREDDER. SC cc SUBARU

AC axial compact fan

MIXING STATIONS VOLUMETRIC MIXING STATIONS GRAVIMETRIC MIXING STATIONS GRAVIMETRIC DOSING-/MIXING STATIONS

INSTRUCTION MANUAL FOR MM10 Relay

High Capacity Double Pillar Fully Automatic Bandsaw. p h a r o s 2 8 0

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Applications Note 164 October 2007

JAPAN QUALITY. Automated Clinical Analyzer

Requirements to perform accurate dielectric material analysis

The Clinical Chemistry System that offers more so you do less!

Transcription:

Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

PERFORMANCE Efficient, results-oriented working processes are top priority in both research and routine laboratories. Advanced laboratory technology makes a significant contribution to shortening processing times. For decades, ROTANTA centrifuges from Hettich have been distinguished by the highest quality. Excellent performance and an extensive range of accessories guarantee fast, trouble-free operation in daily laboratory use. With a maximum capacity of 3 litres per run, they are proving themselves in clinics and laboratory centres, as well as in Life Science R & D departments. For sample processing in clinical chemistry, a wide selection of adapters are available to accommodate the most varied types of tubes. Biotechnology, molecular biology and the pharmaceutical industry value the ROTANTA 460 especially for its autoclavable and aerosoltight accessories. These versatile benchtop centrifuges feature a filter plate rotor with an RCF of 6,446 for purifying DNA/RNA. Model variants of the refrigerated ROTANTA 460 R with connection for nitrogen flushing (Cat. No. 5660-20), as heating/cooling version up to 90 C (Cat. No. 5660-50), or as heating/cooling version with connection for nitrogen flushing (Cat. No. 5660-70), on request. High speed with angle rotors: 24,400 RCF with a max. capacity of 30 x 1.5/2.0 ml 18,038 RCF with a max. capacity of 6 x 94 ml 14,025 RCF with a max. capacity of 6 x 250 ml High capacity with swing-out rotors: 4 x 750 ml at max. 4,779 RCF 24 microtitre plates / 4 filter plates at max. 4,211 RCF or 12 microtitre plates / 2 filter plates at max. 6,446 RCF 196 blood collection tubes at max. 2,906 RCF USER-FRIENDLINESS Powered lid locking Ergonomic control and information panel Easy rotor changing 98 program storage spaces Protection against unauthorized operation / modification of stored programs Switch of centrifuge run time from at start (commencement at start) to at speed (start when nominal speed is attained) Special braking ramps for centrifuging blood bags in the refrigerated models Program interlocking to combine several centrifugation runs (optional) COOLING (ROTANTA 460 R, 460 RC and 460 RF) Infinitely variable adjustment from - 20 C to + 40 C (or - 4 F to + 104 F) Stand-by cooling SAFETY Imbalance switch-off Automatic rotor recognition Emergency lid lock release Lid dropping protection Lid locking and holding during rotor run Motor overheating protection Chamber overheating protection with (ROTANTA 460 R, 460 RC und 460 RF) centrifuges ROTANTA 460 R benchtop centrifuge, cooled, Cat. No. 5660 ROTANTA 460 benchtop centrifuge Cat. No. 5650 2

OPERATION AND CONTROL DIGITAL DISPLAY AND CONTROL PANEL With the convenient C control panel, even the most challenging centrifugation programs can easily be keyed in, stored and accessed as required. KEYBOARD START Start centrifugation run / short centrifuging runs / save entries and changes Start pre-cooling program PREC STOP Manually end centrifugation run / OPEN Open lid PARAMETER INPUT ROTANTA 460 R, 460 RC and 460 RF control panel (C control panel) PROG Input / recall program number 98 programs can be stored T/ C Input temperature in increments of 1 from - 20 C to + 40 C or - 4 F to + 104 F (ROTANTA 460 R, 460 RC and 460 RF) Input of acceleration levels 1 9 Input of braking levels 1 9 Input brake force cut-off RCF Input relative centrifugal force (RCF) in increments of 1 Enter centrifuging radius (RAD) in mm RPM Input speed in increments of 10 TIME Input length of centrifugation (max. 99 h : 59 min : 59 sec) or continuous operation ROTANTA 460 RC underbench centrifuge, cooled Cat. No. 5670 ROTANTA 460 RF floorstanding centrifuge, cooled Cat. No. 5675 3

ROTORS AND ACCESSORIES Swing-out rotor, 4-place, for ASTM tubes Swing-out rotor, 6-place, for chrome bath tubes ) 90 n = 2,000 min -1 max. RCF 984 Cat. No. (without carriers) 4474 ) 90 n = 2,000 min -1 max. RCF 917 Cat. No. 4619 16) capacity in ml 50 100 100 100 Ø x L in mm 45x130 58x161 44x168 37x200 Cat. No. - 2) 0528 2) - 2) 0531 2) carrier Cat. No. 4275 capacity in ml 30 Ø x L in mm 24 x 151 Cat. No. 0529/0508 13) rotor Cat. No. 4474 Cat. No. 4278-A 0771 4277 4276 boring Ø x L in mm - tubes per rotor 4 max. RCF 2) 984 961 radius in mm 220 215 run-up in sec 17 run-down in sec, braked 20 temperature in C 1) -8 rotor Cat. No. 4619 16) Cat. No. - boring Ø x L in mm - tubes per rotor 6 max. RCF 917 radius in mm 205 run-up in sec 17 run-down in sec, braked 21 temperature in C 1) -11 13) The tube may not be centrifuged with the stopper. The stopper only serves to close the tube for agitating or mixing. 16) In the heatable models 5660-50, 5660-51, 5660-70, 5670-50 and 5675-50, rotors 4619 and 5616 may only be used up to a maximum of + 40 C. 27

TECHNOLOGY ROTANTA 460 ROTANTA 460R > ) Benchtop centrifuge, without rotor classic cooled Power supply* ) 200 240 V 1 p 100 127 V 1 ~ 200 240 V 1 p 100 127 V 1 ~ 100 V 1 ~ Frequency 50 60 Hz 50 Hz 60 Hz 50 Hz Consumption 1,000 VA 1,100 VA 1,800 VA 2,000 VA Emission, Immunity EN / IEC 61326-1, class B FCC class B EN / IEC 61326-1, class B FCC class B Max. capacity 4x 750 ml Max. RPM (speed) 15,000 min -1 Max. RCF 24,400 Running time 1 sec - 99 h : 59 min : 59 sec, continuous run, short cycle mode Dimensions (H x W x D) 456 x 554 x 706 mm 456 x 554 x 715 mm 456 x 770 x 706 mm 456 x 770 x 715 mm Weight approx. 101 kg approx. 111 kg approx. 141 kg approx. 151 kg Refrigeration Temperature control, infinitely variable - from - 20 to + 40 C Cat. No. 5650 5650-01 5660 5660-01 TECHNOLOGY ROTANTA 460 RC > ) * ) Other voltages on request. >) Additional model variants on request. ROTANTA 460 RF > ) Underbench centrifuge, cooled, without rotor Floorstanding centrifuge, cooled, without rotor Power supply* ) 200 240 V 1 ~ Frequency 50 Hz Consumption 1,800 VA Emission, Immunity EN / IEC 61326-1, class B Dimensions (H x W x D) 683 x 554 x 697 mm 961 x 554 x 697 mm Weight approx. 140 kg approx. 164 kg Temperature control, infinitely variable from - 20 to + 40 C The other values are identical with those of the ROTANTA 460 R Cat. No. 5670 5675 Hettich centrifuges comply with all relevant EU standards in effect and conform to the European level of quality and safety for medical devices. Evidence is provided by national and international test marks such as IEC 61010 or the CE conformity. The ISO 9001, ISO 13485 and ISO 14001 certificates accredited to the company bear witness to the extreme care and responsibility Hettich puts into the manufacturing of centrifuges and their accessories. P5650GB.0813 by Andreas Hettich GmbH & Co.KG, 78532 Tuttlingen Printed in Germany Design, form and colour modifications reserved. Andreas Hettich GmbH & Co. KG Föhrenstr. 12 D-78532 Tuttlingen Germany www.hettichlab.com info@hettichlab.com service@hettichlab.com Phone +49 (0)7461/705-0 Fax +49 (0)7461/705-1122 National Sales: -12 00 International Sales: -12 01 National Service: -12 02 International Service: -12 03