Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Similar documents
Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

Performance analysis of V-jagged twisted tape insert for heat transfer in a circular tube

International Journal of Advanced Engineering Research and Studies E-ISSN

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

Experimental and Numerical Analysis of Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Tube Using Mesh Inserts

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

AUGMENTATION OF HEAT TRANSFER USING COILED POROUS TWISTED TAPE INSERT

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe

Heat Transfer Enhancement Using a Rotating Twisted Tape Insert

Department of Mechanical Engineering, VTU, Basveshwar Engineering college, Bagalkot, Karnataka, India

Sarbendu Roy, Manvendra Tiwari and Sujoy Kumar Saha 1. Mechanical Engineering Department, IIEST, Shibpur, Howrah , West Bengal, INDIA

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

Heat Transfer Enhancement Through Perforated Fin

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

Heat Transfer Analysis of Helical Strip Insert with Regularly Spaced Cut Sections Placed Inside a Circular Pipe

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

International Journal of Innovative Research in Science, Engineering and Technology

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER

Study of Compound Heat Transfer Enhancement of Horizontal Liquid-Solid Fluidized Bed Heat Exchanger with a Kenics Static Mixer

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Experimentation and Performance Evaluation of Heat Exchanger Using Z-Ribs

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate

Experimental Investigation of Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO/water Nano fluid

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

International Communications in Heat and Mass Transfer

International Communications in Heat and Mass Transfer

Forced Convection Heat Transfer Augmentation from Ribbed Surface

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Experimental Investigation of Trapezoidal Duct using Delta Wing Vortex Generators

Chapter 3 NATURAL CONVECTION

Experimental Investigation of Trapezoidal Duct using Delta Wing Vortex Generators

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

Heat Transfer Enhancement Analysis of Flow over the Bumps on Divergent Channel

EXPERIMENTAL STUDIES ON HEAT TRANSFER AUGMENATATION USING GALVANISED IRON WIRE INSERT WITH AND WITHOUT BAFFLES

Experimental Analysis of Heat Transfer Enhancement through Pipe using Baffles

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

Numerical investigation of heat transfer enhancement in a pipe heat exchanger by adding nano particle and twisted tape

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

Heat transfer characteristics and friction of turbulent swirling air flow through abrupt expansion

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

Heat Transfer Investigation in a Circular Tube Fabricated from Nano-composite Materials Under a Constant Heat Flux

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

Forced Convection: Inside Pipe HANNA ILYANI ZULHAIMI

Numerical Analysis of Fe 3 O 4 Nanofluid Flow in a Double Pipe U-Bend Heat Exchanger

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001

Experimental Investigation of Natural Convection Heat Transfer in Heated Vertical Tubes

EXPERIMENTAL INVESTIGATION OF THE HEAT TRANSFER IN A HORIZONTAL MINI-TUBE WITH THREE DIFFERENT INLET CONFIGURATIONS

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

EXPERIMENTAL STUDIES ON HEAT TRANSFER AUGMENTATION USING TRIANGULAR WAVY TAPE (TWT) AS INSERTS FOR TUBE SIDE FLOW OF LIQUIDS

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Analysis, Design and Fabrication of Forced Convection Apparatus

Convection Heat Transfer. Introduction

HEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR

Performance evaluations of two pass solar air heater using 60⁰ inclinedvshaped ribs on absorber plate

Heat Transfer Enhancement in Fe3O4-water Nanofluid through a Finned Tube Counter Flow Heat Exchanger

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

International Journal of Emerging Technologies in Engineering Research (IJETER)

PLATE TYPE HEAT EXCHANGER. To determine the overall heat transfer coefficient in a plate type heat exchanger at different hot fluid flow rate

Numerical Investigation of The Convective Heat Transfer Enhancement in Coiled Tubes

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Numerical Investigation on The Convective Heat Transfer Enhancement in Coiled Tubes

THE EXPERIMENTAL STUDY OF THE EFFECT OF ADDING HIGH-MOLECULAR POLYMERS ON HEAT TRANSFER CHARACTERISTICS OF NANOFLUIDS

PERFORMANCE ANALYSIS OF PARABOLIC TROUGH COLLECTOR TUBE WITH INTERNAL INTERMITTENT FINS

HEAT TRANSFER ENHANCEMENT BY USING NANOFLUID JET IMPINGEMENT

Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an Inclined Square Duct

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Laboratory/Demonstration Experiments in Heat Transfer: Laminar and Turbulent Forced Convection Inside Tubes. Abstract

ARTICLE IN PRESS. K.R. Aharwal a,, B.K. Gandhi b, J.S. Saini b

Experimental investigation of heat transfer characteristics of pulsating turbulent flow in a pipe

Transcription:

IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 62-67 www.iosrjournals.org Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection D.R. Hase, N.K. Sane, D.V. Ghewade (Department. Of Mechanical Engineering, Walchand College Of Engineering,Sangli, Maharashtra, India) Abstract : Investigations have been carried out over decades to enhance the heat transfer using active, passive and compound heat augmentation techniques. The present work includes passive heat transfer augmentation technique using non-metallic flow divider type inserts with air as working fluid. Whenever inserts are used for heat transfer enhancement, along with increase in heat transfer rate, the pressure drop also increases. This increase in pressure drop increases the pumping cost. Hence heat augmentation technique should optimize between the benefits of heat transfer rate and increased pressure drop. Initially, for validation of setup, experiments were carried out for plain tube. The results i.e. Nusselt number and friction factor obtained were validated against those obtained from empirical correlation. Secondly, Experimental investigations were carried out using flow divider type non-metallic inserts with varying the Reynolds number and heat input. The nusselt number is increased by 170% than that for plain tube. Overall Enhancement Efficiency(OEE) for different Reynolds number was above unity. Keywords : Forced Convection, Flow Divider Insert, Heat Augmentation, Nusselt Number, Reynolds Number. I. Introduction Heat transfer processes in industrial, Automotive and domestic application involves the conversion, transfer and utilization of heat energy. The enhancement of heat transfer in such several application can significantly improves the thermal performance of heat exchange equipments. Heat augmentation techniques are used to increase the convective heat transfer coefficient by increasing the turbulence of the fluid. This technique also leads to increase in pressure drop and consequently the pumping cost. Hence the augmentation technique should optimize between the heat transfer rate and pressure drop. Heat transfer augmentation techniques are broadly classified into three categories: 1) Active techniques, 2) Passive techniques and 3) Compound techniques. Active methods require some external power input for the improvement of heat transfer and have not shown much prospective owing to intricacy in design. While, Passive methods do not need any external power input and the supplementary power needed to augment the heat transfer is taken from fluid itself, which ultimately leads to drop in fluid pressure. Compound methods are hybrid methods in which both active and passive methods are used in combination. Passive and active techniques that are used for heat augmentation of laminar flow have been discussed in detail by Bargles[1].These are effective but involve complicated design and hence have limited applications [1-3]. Heat augmentation can further increased by perforating the twisted tape with different shapes with different arrangement [3]. These techniques includes twisted tape [3,6]. Use of alternate clockwise and counterclockwise twisted tapes with different twist ratio increases the nusselt number over a range of Reynolds number with uniform flux condition. It leads to superior chaotic mixing [6]. Square cut circular ring [4], coiled tube [5], rough surfaces [8], additives to the fluid [8], extended surfaces [10] have been used successfully to enhance heat transfer. According to the first technique, insert acts as a turbulence promoter, producing the helical flow of fluid which induces the drive forces to move the heated fluid from boundary surface to core flow. In second technique, by inducing the heat transfer surface area and redevelopment of boundary layer the thermal performance of system is increased. Insertion of twisted tube is the simple passive technique for enhancement of heat transfer coefficient on the tube side of heat exchanger. Although typical twisted tapes offer better heat transfer enhancement, the tapes leads to high pressure drop penalty which limits thermal performance of systems. Therefore, various modified twisted tapes have been designed to reduce pressure loss by introducing spaces or gaps to twisted tapes. Overall enhancement ratio is used to indicate the thermal performance of the enhancement technique over a plain tube with constant pumping power. Dittus-Boelter and Petukhov correlations of forced convection for plain tube were used to validate the setup. 62 Page

Heat Augmentation Using Non-Metallic Flow Divider Type Inserts in Forced Convection II. Experimental Setup The photograph of experimental setup is depicted in Fig.1.Experimental setup consists of assembly of channel flow passage including blower, orifice meter, wattmeter, test section, nichrome band heater. The test section is the G.I.pipe with inner diameter of 27.5 mm and 500 mm length. Band type nichrome heater is used for heating the pipe (test section). Wattmeter is used to adjust the heater input to the test section. Test section is insulated using asbestos insulation. Two Copper-Constantan (k-type) thermocouple are placed at inlet and outlet section to measure air temperature and 5 thermocouple soldered to the test section. For measuring the pressure head loss across the test section, tapping are provided at inlet and outlet of test section. This head loss is measured using digital manometer. Velocity of air is calculated from the discharge obtained from manometer attached across orifice plate. Control valve is used to adjust the flow rate of air. Before experimentation thermocouples and orifice plate were calibrated. A b Fig.1. a) Photograph of experimental setup b) Nylon flow divider insert The non-metallic flow divider type insert, which is used as turbulence promoter is depicted in fig.1b. Angle between two consecutive blades is kept 90 degree. III. Experimental Procedure Validation of test set up is done by conducting experiments for known values from Dittus Boelter and Blasius correlations. Supply is given to the blower motor and the valve is opened slightly. The blower is started and the airflow rate was adjusted by operating the control valve, so that the desired difference in manometer level (40 mm, 80 mm, 120 mm, 160 mm or 200 mm) is obtained. Switch on the supply to Nichrome band heater fitted on the test section and give desired voltage input by adjusting the dimmerstat. Thermocouples 2 to 6 are fixed on the test surface to measure surface temperature and thermocouples 1 and 7 are fixed inside the pipe to measure inlet air temperature and outlet air temperature respectively. The readings of the thermocouples are observed every 5 minutes until they show constant values. The variation of tube wall temperatures (T2, T3, T4, T5 and T6) are observed until the constant value is attained and then the outlet air temperature (T7) is measured after it reaches a steady state. The readings of all the seven thermocouples are recorded for three different heater inputs 50W, 75W and 100W respectively. For each test run, temperatures, volumetric flow rate and pressure drop of bulk air at steady state conditions were noted down. The fluid properties were calculated as the average between the inlet and the outlet temperature. Experiment is carried out at constant heat flux conditions at different mass flow rates. The Reynolds number was varied from 5000 to 17000 during the experimentation. The Nusselt number and the Reynolds number are based on the average tube wall temperatures and the inlet and outlet air temperatures. Nusselt numbers and friction factor calculated from the experimental data for plain tube are compared with the correlations recommended by Dittus Boelter and Blasius. 63 Page

Mean Bulk Temperature, Heat Augmentation Using Non-Metallic Flow Divider Type Inserts in Forced Convection IV. Equations And Correlations T mb = ( o C) (1) Mean Surface Temperature, T S ( o C) (2) Properties of air, Cp, µ, k and Pr are calculated at bulk mean temperature i.e. at T mb.. Equivalent Column Height of Air, h a (m) Volume flow rate Q d (m 3 /s) (3) (4) Mean Velocity of Air through Pipe U = (m) (5) Nusselt number from Dittus-Boelter correlation is given as, ( Nu ) DB = 0.023 x Re 0.8 x Pr 0.4 (6) Where, Reynolds Number (Re) = (7) Prandtl Number (Pr) = (8) Nusselt number from experimental data can be calculated as, (Nu) exp = (9) Where, Convective heat transfer coefficient (h) = (W / m 2 K) (10) Hydraulic diameter (D h ) = (m) (11) Friction factor Blasius correlation for plain tube, f = 0.316 x Re -0.25 (12) Friction factor from petukhov Correlation for plain tube, f = (0.79 x ln Re 1.64) -2 (13) Friction factor obtained from experimental data can be calculated as, f = (14) V. Results And Discussion Nusselt number obtained from equation (6) and (9) and friction factor obtained from equation (12), (13) and (14) are compared in order to validate the experimental setup. It is observed that, the experimental data are in 64 Page

Heat Augmentation Using Non-Metallic Flow Divider Type Inserts in Forced Convection good agreement with the correlation values, i.e., Dittus Boelter Correlation and with Blasius correlation as shown in Fig.2 a) For heater input P = 50 b) For heater input P = 100W c) Friction factor vs Re Fig.2. Validation of setup (plain tube) Experimental investigations were conducted with the flow divider type fiber inserts revealed that, thermal performance of tube fitted with fiber inserts were better than that of plain tube. Results obtained from plain tube and with inserts are as shown in fig.3. Nusselt number and heat transfer coefficient increases for nylon insert. Maximum increase in Nusselt number is 170% of the plain tube.the friction factor, which is high at lower Reynolds number, tends to reduce with the increase of Reynolds number as shown. This is due to the fact that, f is inversely proportional to square of velocity for a given pipe. So, friction factor is decreases due to increased velocity associated with increase in mass flow rate as shown in fig.4. Overall enhancement ratio and enhancement efficiency are the important terms used to compare the thermal performance of the insert.the Overall Enhancement Rratio(OER) is useful to evaluate the quality of heat transfer enhancement obtained over plain tube at constant pumping power. The value of OER is above unity for different flow rate of air and heater input and maximum value of OER is 1.338 as shown in fig.5. η = Where, Nu i = Nusselt number with insert f i = friction factor with insert 65 Page

Nu Heat Augmentation Using Non-Metallic Flow Divider Type Inserts in Forced Convection Enhancement efficiency (ѱ) indicates thermal performance of heat augmentation technique. Enhancement efficiency is increases with increase in Reynolds number. Maximum value of enhancement efficiency obtained is 2. Fig.4.6 shows the variation of enhancement ratio with Reynolds number. Ѱ = Where, h i = convective heat transfer coefficient with insert 80 70 60 50 40 30 20 10 0 7000 9000 11000 13000 15000 with Nylon Insert Re plain tube Dittus-Boilter a) For heater input P = 50W b) For heater input P = 100W Fig.3 Comparison of Nusselt number with and without insert Fig.4 Variation of friction factor with Reynolds number VI. Conclusion Experimental investigations were performed to investigate the friction factor and heat transfer characteristics in an externally heated horizontal tube fitted with different types of inserts. For plain tube, the experimental data is in good agreement with correlations value i.e. Dittus-Boelter and petukhov correlation. Experimental data of the present work is reasonably agreed within 10% for Nusselt number from Dittus Boelter correlation and 13 % for friction factor from Blasius correlation. For non-metallic flow divider type inserts, the Nusselt number is 170% of that for plain tube. OER is above unity and maximum value obtained is 1.338.Enhancement efficiency ranges from 1.5 to 2 which show that the thermal performance is improved. 66 Page

Heat Augmentation Using Non-Metallic Flow Divider Type Inserts in Forced Convection Fig.5.Variation of Overall Enhancement ratio for different Reynolds number REFERENCES [1]. A Dewan, P Mahanta, K Sumithra Raju and P Suresh Kumar,Review of passive heat transfer augmentation techniques Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 2004. [2]. Hasenpur, M.farhadi and k.sedighi, A Review study on twisted tape inserts on turbulent flow heat exchanger: The overall enhancement ratio criteria, International communication in Heat and Mass Transfer. 55,2014,53-62. [3]. Chou Xin Tan, Wai Loon Mah, Yew Mun Hung and Boon Thong Tan, On the role of inserts in forced convection heat transfer augmentation, International Communication in Heat and Mass Transfer.39,2012,1138-1145. [4]. S.Rainieri, F.Bozzoli, G.Pagliarini, Experimental investigation on the convective heat transfer in straight and coiled corrugated tubes for highly viscous fluid : Preliminary results, International Journal of Heat and Mass Transfer 55 (2012) 498-504. [5]. Smith Eiamsa ard and Pongjet Promvonge, Performance assessment in heat exchanger tube with alternate clockwise and counter-clockwise twisted-tape inserts, International Journal of Heat and Mass Transfer 53,2010, 1364-1372. [6]. Atipoang Nuntaphan, Sanparwat Vithayasai, Nat Vorayos, Nattanee Vorayos, Tanongkiat Kiatsiriroat,Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement, International Journal of Heat and Mass Transfer 37,2010, 287-292. [7]. A. Rabienataj Darzi, Mousa Farhadi,Kurosh Sedighi, Shahriar Aallahyari, Mojtaba Aghajani Delavar, Turbulent heat transfer of Al2O3 water nanofluid inside helically corrugated tubes:numerical study, International Journal of Heat and Mass Transfer 41,2013, 68-75. [8]. Bargles, A. E. Techniques to augment heat transfer. Hand-book of Heat Transfer Applications. Ed. W.M. Rosenhow 1985 Ch. 3 McGraw-Hill New York. 67 Page