GC-APCI IMS of Diesel

Similar documents
Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Accurate Mass Analysis of Hydraulic Fracturing Waters

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Agilent All Ions MS/MS

Agilent ESI and APCI sources: for polar to non-polar compounds

Agilent G3212 GC-APCI Source

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Author. Abstract. Introduction

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Selection of a Capillary

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Highly Sensitive and Rugged GC/MS/MS Tool

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

MassHunter TOF/QTOF Users Meeting

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

TANDEM MASS SPECTROSCOPY

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Application Note. Authors. Abstract. Introduction. Environmental

JWH-018 and JWH-022 as Combustion Products of AM2201

GC MS of Diesel: A Two-Dimensional Separation Approach

Selection of a Capillary GC Column

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Introduction to GC/MS

Making Sense of Differences in LCMS Data: Integrated Tools

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

The Pulsed Flame Photometric Detector for analysis of phosphorus pesticides in wastewater and food commodities

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Application Note. Edgar Naegele. Abstract

Kendrick mass = IUPAC mass x (14/ ) (1) Kendrick mass defect = nominal Kendrick mass exact Kendrick mass (2)

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

WADA Technical Document TD2003IDCR

Determination of Hydrocarbon Components in Petroleum Naphthas

GC Analysis of Polybrominated Flame Retardants Application

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

Introduction to the Q Trap LC/MS/MS System

Automated Characterization of Compounds in Fire Debris Samples

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

2401 Gas (liquid) Chromatography

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

CEE 772: Instrumental Methods in Environmental Analysis

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Automated PIONA Analysis by ASTM D8071 and VUV PIONA+

MassHunter Software Overview

Cerno Application Note Extending the Limits of Mass Spectrometry

Ion Mobility-Mass Spectrometry: A Tool for Characterizing the Petroleome

Reading Skill Practice

Interpretation of Organic Spectra. Chem 4361/8361

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Approaches to quantify the effect of extracted plant material on PHC levels.

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

An extended siderophore suite from Synechococcus sp. PCC 7002 revealed by LC- ICPMS-ESIMS

Transcription:

GC-APCI IM of Diesel Application Note Energy and Chemicals Authors heher Bano Mohsin, David Wong, and F. Robert Ley Agilent Technologies, Inc. Abstract This Application Note describes the use of ion mobility and high-resolution GC/M for profi ling sulfur compounds in a very complex sample such as diesel fuel. The analysis of sulfur compounds in diesel can be challenging because of this matrix complexity. Gas chromatography/high-resolution mass spectrometry is a useful tool when identifying peaks, but, in the case of petroleum, such attempts are usually frustrated by isobaric coeluting hydrocarbons. Ion mobility, coupled to high-resolution GC/M, provides an extra dimension of separation based on size, charge, and shape. This study demonstrates the advantage of coupling GC-APCI to ion mobility high-resolution mass spectrometry for the study of aromatic sulfur compounds in diesel.

Introduction The economic value of diesel depends on its chemical composition. Molecules containing heteroatoms such as sulfur lower the value of fuel, as they burn in air and produce smog. The amount of sulfur in diesel is being decreased because of environmental regulations. The distribution of sulfur-containing compounds in various feedstocks is important, as the refining process can be modified to meet regulations. Refineries use a process called hydrodesulfurization to remove sulfur from sulfur-containing compounds. For hydrodesulfurization, sulfur bound in aromatic structures such as benzothiophenes and dibenzothiophenes and their alkyl-substituted analogs is the most difficult to remove catalytically. Therefore, it is important to study these species. Experimental ample preparation amples of processed and unprocessed diesel were diluted 1:10 with isooctane, and analyzed without any additional sample preparation. Instrumentation Agilent 7890B GC with the GC-APCI interface Agilent 6560 Ion Mobility Q-TOF GC/M GC Drift IM oftware Agilent MassHunter Data Acquisition oftware for Agilent Ion Mobility Q-TOF Mass pectrometer, Version B.07.00 Agilent MassHunter Qualitative oftware, Version B.07.00 GC-APCI Figure 1 shows a schematic of the GC-APCI IM Q-TOF. The setup and operation of the GC-APCI is described in detail elsewhere 1. The source parameters for GC-APCI are listed in Table 1. M and M/M The profiling of sulfur compounds in diesel can be challenging because of its very complex matrix. There are thousands of different compounds in diesel, ranging from alkanes, alkenes, aromatics, and heteroatomic sulfur, nitrogen, and oxygen compounds. The probability of completely resolving a single class of compound from all others in the sample is low. High pressure ion funnel Drift tube entrance Trapping funnel Drift tube exit Ion drift tube Rear ion funnel Hexapole Octopole Quad Mass Filter (Q1) Lenses 1 and 2 Figure 1. chematic of the Agilent GC-APCI IM Q-TOF system. Collision cell Hi-res slicer assembly Ion pulser Hi speed detector assembly Gas chromatography/high-resolution mass spectrometry is a useful tool when identifying peaks but, in the case of diesel, such attempts are usually frustrated by isobaric coeluting hydrocarbons. Ion mobility, coupled to GC/M, provides an extra dimension of separation based on size, charge, and shape. After chromatographic separation, the ions formed in the source are separated again in the gas phase in the mobility cell. Larger ions traverse the drift tube at a slower rate than smaller ions resulting in gas-phase ion separation. This Application Note demonstrates the use of ion mobility for separating aromatic sulfur-containing compounds from the matrix. Two samples of diesel are compared, before and after hydrodesulfurization. Table 1. GC and M conditions. Parameter Value Column Agilent J&W DB-5ms, 30 m 0.25, 0.25 µm Injection port plit/splitless Injection volume 1 µl Mode Constant flow, 1.3 ml/min, 15 psi at 50 C plit ratio 1:10 Flow rate 1.3 ml/min Oven program 50 C (2 minutes) to 250 C at 10 C/min (10 minutes), then 300 C at 15 C/min (10 minutes) Table 2. Agilent 6560 Ion Mobility Q-TOF LC/M source parameters for positive ion mode method. Parameter Value Ion mode Positive Drying gas temperature 250 Drying gas flow 11 L Capillary voltage 1,000 V kimmer 65 V Corona 1 µa Fragmentor 150 V Resolution at 121 m/z 2

IM Q-TOF The Agilent 6560 IM Q-TOF is a Q-TOF LC/M system that can be run in either ion mobility mode or Q-TOF only mode. It consists of a trapping funnel, drift tube, and rear funnel between the front funnel and ion optics leading to the quadrupole mass filter. This design builds on the well-established Q-TOF system in the back end, and proven high-sensitivity ion-funnel technology. The fast duty cycle of ion mobility (milliseconds) is well matched with the fast acquisition of TOF (microseconds). The fast acquisition of the TOF is well-suited to sampling the very narrow peaks generated by the GC. IM is a gas-phase ion separation technique that is carried out in a drift tube filled with an inert drift gas (nitrogen), and energized with a low DC electric field. Larger ions traverse the drift tube at a slower rate than smaller ions, resulting in gas-phase ion separation. The ability to separate ions at the millisecond time scale is particularly advantageous when chromatographic separation of complex mixtures is not possible. This powerful combination of separation, resolution, and structural information is key for solving the most challenging applications. Results and Discussion By coupling the GC to the 6560 IM Q-TOF, we created an analytical system with much greater separation power for these types of complex compound analyses. The additional dimension of orthogonal separation greatly adds to the peak capacity/separation power of the overall system. As we demonstrate, ion mobility is effectively used to pull apart overlapped and smaller peaks in a complex mixture. One of the most important attributes of ion mobility separation is its specificity. In particular, ion mobility effectively cleans up background chemical noise due to column bleed. The mobility heat map shows hundreds of components in the sample with overlapping compounds at nearly every m/z value. The highlighted polygon region in the heat map shows the fingerprint due to column bleed. The ion mobility of polysiloxanes is very different from the hydrocarbon matrix, and separate easily from sample-related compounds. Figure 2 shows the screen capture of these compounds. The bottom graphic shows the mobility filtered mass spectrum that removes many of the overlapping chemical background ions. This eliminates the need to do any background subtraction. Figure 2. Compounds separated according to carbon number in the drift time domain. The circled area is column bleed, which has shorter drift times than the hydrocarbons, and separates out 3

Comparison of pre- and post-treatment diesel samples Figure 3 shows a comparison of the two diesel samples pre- and post-treatment. A visual inspection of the graph shows differences in the distribution of molecular weights in the two samples. ample C, which is the sample after hydrodesulfurization, shows a molecular weight distribution towards the lower molecular weights expected from this treatment. The advantage of using high-resolution mass spectrometry is apparent in Figure 4, which shows a plot of an extracted ion chromatogram with a mass defect window set to mass defects below 0.1 amu. Figure 4A is the untreated sample, which shows an abundance of high-intensity peaks with the mass defects below 0.1 amu that are indicative of sulfur compounds. Mass (Da) 600 500 400 300 200 100 The treated sample (Figure 4B) lacks these peaks. Figure 4C shows the mass spectrum of a region in the chromatogram of the untreated sample around 11.56 minutes retention time. The peak at 213 m/z, with its isotopic fit (superimposed in red), is indicative of dibenzothiophene species. 0 0 2 4 6 8 10 12 14 16 18 Retention time (min) Figure 3. Comparison of diesel samples before and after hydrodesulfurization. The features in blue are from the diesel sample after treatment. 10 5 A 4 3 2 1 0 10 5 Counts 4 B 3 2 1 0 9.0 9.4 9.8 10 5 4 C Counts 10.2 10.6 11.0 11.4 11.8 12.2 12.6 13.0 13.4 13.8 14.2 14.6 15.0 15.4 15.8 16.2 16.6 17.0 17.4 Acquisition time (min) 213.0741 ([C 14 H 12 ]+H) + Diesel before hyrdodesulfurization Diesel after hyrdodesulfurization Counts 3 2 1 0 147.0267 155.0858 169.1015 161.0421 175.0586 183.1172 192.0938 198.0504 189.0739 255.1636 231.1210 240.1870 247.1517 255.2105 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 Mass-to-charge (m/z) Figure 4. Extracting the dibenzothiophenes (mass defect below 0.1 amu) 4

Analysis of dibenzothiophenes Figure 5 shows possible structures for dibenzothiophenes. The use of Kendrick mass defect to identify series of related compounds is well established for complex samples 3,4. The Kendrick mass scale, which defines the mass of CH 2 as exactly 14.0000, is used to identify families of compounds that differ only by the length of alkyl substituents. We used mmass, a program available on the Internet that automatically calculates and plots Kendrick mass defect from raw mass spectral data (Figure 6). C 13 H 10 C 12 H 8 H 3 C C 14 H 12 Using the Kendrick mass defect plot allowed us to identify related dibenzothiophenes. The drift spectra of a series of related dibenzothiophenes are shown in Figure 7. H 14 H 3 C C 16 H 16 If we consider a homologous series of molecules of the same class and DBE, but varying degree of alkylation, members of the series will vary in composition by multiples of -CH 2, corresponding to multiples in a mass of 14.01565 Da. A particularly useful way to identify such a series is to convert the IUPAC mass to Kendrick mass. The Kendrick mass is calculated using Equation 1. Kendrick mass = IUPAC mass (14.00000/14.01565) Figure 5. Possible structures of dibenzothiophenes. Note: several structural isomers are possible for each of these formulae. 184 198 212 226 240 254 Increasing CH 2 Equation 1 uccessive members of an alkylation series will differ by 14.00000 in Kendrick mass and, therefore, each will have the same Kendrick mass defect (KMD). The Kendrick mass defect is the difference between nominal Kendrick mass and exact Kendrick mass (Equation 2). Kendrick mass defect (KMD) = Kendrick mass nominal Kendrick mass Equation 2 Using this scheme, members of a given alkylation series are easily identified, and the assignments can be extended to higher masses by extrapolation. In a KMD plot, the Kendrick mass is used for the X-axis and KMD is used for the Y-axis. From left-to-right, the numbers of CH 2 units in the observed ions increase. From top-to-bottom, the differences in chemical formula, such as the degree of unsaturation, oxidation, and so on, increase. Figure 6. Kendrick mass defect plot showing series of related dibenzothiophenes with the same Kendrick mass defect. Counts 10 4 4.8 4.4 4.0 3.6 3.2 2.8 2.4 2.0 1.6 1.0 0.8 0.4 0 11.13 10.5 11.0 11.77 12.15 Figure 7. Drift spectra of a series of related dibenzothiophenes. H 3 C 12.85 11.5 12.0 12.5 13.0 13.5 Drift time (ms) 5

Each dibenzothiophene peak has interferences from other hydrocarbon species. This interference is revealed in the Kendrick mass defect plot, which shows unrelated compounds with the same nominal mass but different KMD on the vertical axis (Figure 8). These unrelated interfering compounds can be separated with ion mobility (Figure 9). Figure 8. Kendrick mass defect plot showing background and dibenzothiophene with their respective different mass defects. Figure 9. Ion mobility spectrum of dibenzothiophenes and other interfering hydrocarbons. 6

Analysis of hydrocarbons Generally, diesel samples contain many series of hydrocarbon molecules that overlap in the same mass range, which can bring great challenges for data interpretation using conventional M systems. By adding the ion mobility dimension of separation and using the data extraction feature in the Agilent IM browser, we easily obtain information on the ion series of interest for further study. The Kendrick plot can also be used to observe complex patterns in the mass spectra of hydrocarbon species (Figure 10). The horizontal line in Figure 11 shows hydrocarbon species differing by a CH 2 unit but with the same DBE value. The next series of compounds on a horizontal line differ by 0.013, or 2H. These patterns are easily separated in the mobility domain, as shown in Figure 12. Analysis of ATM standards In this study, we analyzed the ATM standard compound mixture. In a very narrow GC peak at ~4.4 minutes, we found over 10 compounds, including many isomers in the mass range of 100 to 125 Da. The early eluters in the GC chromatogram have more interference and coelution of compounds in the low molecular weight range. Ion mobility provides higher peak capacity and much more detailed information about the individual species. Counts 10 5 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 145.1012 141.0700 135 140 145 155.0856 C 12 H 8 159.1170 C 13 H 10 C H 14 12 173.1326 183.1169 H 14 195.1170 H 16 C 16 H 16 H 18 199.1482 213.1638 H 20 H 22 C 17 H 18 227.1793 241.1949 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 Mass-to-charge (m/z) Figure 10. Hydrocarbon series differing by a CH 2 unit. The finer pattern within the series differs by 2H. Figure 11. Kendrick mass defect plot for a series of related compounds with KMD of 0.1008. 7

Figure 12. Ion mobility separation map for molecular weights from m/z 178 to 232. Possible isomers CH3 1,2-Dimethylbenzene -ortho-xylene 1,3-Dimethylbenzene -meta-xylene 1,4-Dimethylbenzene -para-xylene Ethylbenzene Figure 13. Possible structural isomers for C 8 H 10. 8

Conclusions Two samples of diesel fuel, before and after hydrodesulfurization, were compared. Aromatic sulfur-containing compounds were differentiated from hydrocarbons using high-resolution mass spectrometry by filtering the data on mass defect. Ion mobility offers an extra dimension in separating isobaric compounds based on drift time in this very complex mixture. Ion series corresponding to alkylated and nonalkylated dibenzothiophenes were clearly separated, and the individual compounds were identified. Kendrick mass defect plots were used to recognize families of homologous compounds. These plots allowed us to extract the ion series of interest for the analysis. Differential analysis of the two samples quickly revealed differences in the degree of sulfur removal between the two samples. Various structural isomers of aromatic compounds coeluting early in the GC chromatogram were also identified. References 1. Goodley, P.; Mohsin,. B. The GC-APCI Interface for the Agilent Q-TOF LC/M ystem Improves ensitivity, Mass Accuracy, and peed for a Wide Range of GC Applications. Agilent Technologies, Inc. Technical Overview, publication number 5991-2210EN, 2013. 2. Jody C. M.; et al. Conformational Ordering of Biomolecules in the Gas Phase: Nitrogen Collision Cross ections Measured on a Prototype High Resolution Drift Tube Ion Mobility-Mass pectrometer. Anal. Chem. 2014, 86 (4), pp 2107-2116. 3. Kendr ick, E. A mass scale based on CH 2 = 14.0000 for high-resolution mass spectrometry of organic compounds. Anal. Chem. 1963, 35, pp 2146-2154. 4. Hughey, C. A.; et al. Kendrick mass defect spectroscopy: A compact visual analysis for ultrahigh-resolution broadband mass spectra. Anal. Chem. 2001, 73, pp 4676-4681. Acknowledgements The authors would like to thank Ken Imatani for his help and support. 9

www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 2015 Published in the UA, July 10, 2015 5991-5856EN