E-Guide. Sample Preparation. A guide to ideal sample preparation

Similar documents
Chapter 10. Nanometrology. Oxford University Press All rights reserved.

Electron beam scanning

6.5 Optical-Coating-Deposition Technologies

Electrostatics is the study of non-moving electric charges, sometimes called static electricity.

Defining quality standards for the analysis of solid samples

Praktikum zur. Materialanalytik

Chapter 12. Nanometrology. Oxford University Press All rights reserved.

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

SCANNING-PROBE TECHNIQUES OR APPARATUS; APPLICATIONS OF SCANNING-PROBE TECHNIQUES, e.g. SCANNING PROBE MICROSCOPY [SPM]

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

Nanoscale work function measurements by Scanning Tunneling Spectroscopy

Scanning Electron Microscopy

MANUAL TT-220 TT-220

Nanoscale characteristics by Scanning Tunneling Spectroscopy

States of matter. 22 Science Alive for VELS Level 5

MLCC APPLICATION GUIDE

Peltier Application Note

1W, 1206, Low Resistance Chip Resistor (Lead free / Halogen Free)

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

-:Vijay Singh(09CEB023)

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

Scanning Electron Microscopy

Photosynthesis in Leaf Disks Teacher Preparation and Background Information

Model : JEOL JSM 7610f

Water and Aqueous Systems

Specification LW514. Drawn Approval Approval. Rev. 02 December 서식번호 : SSC-QP (Rev.00)

Requirements to perform accurate dielectric material analysis

Specification LY530. Drawn Approval Approval. Rev. 08 December 서식번호 : SSC-QP (Rev.00)

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Biomedical Nanotechnology. Lec-05 Characterisation of Nanoparticles

ORION NanoFab: An Overview of Applications. White Paper

5mm Silicon PIN Photodiode, T-1 3/4 PD333-3B/H0/L2

5G50.51 Superconductor Suspension

Circular Motion and Centripetal Force

Controlled self-assembly of graphene oxide on a remote aluminum foil

[ Extract from Astronomical Spectroscopy for Amateurs ] 18.0 Guiding, OAG and Beam splitters/ Flip mirrors Off Axis Guiders

Must Read Before Installation TadPoleTM Safety and Warnings

LaserTrim Ceramic Chip Capacitor

Atoms and molecules are in motion and have energy

Particle symbol. electron negative outside nucleus e

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

Inserting grids into capsule Removing capsules from grid box Immunolabeling using template guide Preparing for TEM insertion

EM-30AX is very good space utilization

UNISONIC TECHNOLOGIES CO., LTD LM78XX

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

TESCAN S New generation of FIB-SEM microscope

Microcystin-LR ELISA Kit

#2: THE FLOATING PAPER CLIP

Materials can become electrically charged.

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

Technical Data Sheet 3ψ Infrared Piranha

Chapter 2, Lesson 5: Changing State Melting

SCANNING ELECTRON MICROSCOPE

Electro - Principles I

Electric Field Mapping

Chemical Analysis in TEM: XEDS, EELS and EFTEM. HRTEM PhD course Lecture 5

Name Date Class THE NATURE OF GASES

3mm Photodiode PD204-6B

Instrumentation and Operation

Lab in a Box Measuring the e/m ratio

Classifying Chemical Reactions: Lab Directions

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Introduction. Sample kit content

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Microcystin-LR ELISA Kit

Catalytic bead sensors are used primarily to detect

Particle size analysis -Chapter 3

Modern Optical Spectroscopy

Low Inductance Ceramic Capacitor (LICC)

TEA10402V15A0 Engineering Specification

Making Sense of Matter Study Guide. Matter is anything that takes up space and has mass.

Questions on Electric Fields

Substances and Mixtures:Separating a Mixture into Its Components

Introduction to Photolithography

Jumbo Cross Beam Ionizer

Bisphenol A ELISA Kit

EXTRA CREDIT PAGES K

Specification LR521. Drawn Approval Approval. Rev. 05 December 서식번호 : SSC-QP (Rev.00)

Interface (backside) & Extraction Lens

Graphene. Tianyu Ye November 30th, 2011

GRAPHENE ON THE Si-FACE OF SILICON CARBIDE USER MANUAL

Competitive Advantages of Ontos7 Atmospheric Plasma

Electric Field Mapping

Imaging Carbon materials with correlative Raman-SEM microscopy. Introduction. Raman, SEM and FIB within one chamber. Diamond.

WW12C, WW08C, WW06C, WW04C, WW02C. Low ohm chip resistors ( power ) Size 1206, 0805, 0603, 0402, 0201

6.7 Design Your Own Experiment: Factors

ECE185 LIQUID CRYSTAL DISPLAYS

A New Dielectrophoretic Coating Process for Depositing Thin Uniform Coatings on Films and Fibrous Surfaces

Introduction to Blackbody Sources

Practical 1P4 Energy Levels and Band Gaps

What factors, including environmental variables, affect the rate of transpiration in plants?

Fadei Komarov Alexander Kamyshan

LaserTrim Ceramic Chip Capacitor

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

The physical state of a substance can be changed by increasing or decreasing its temperature.

ELECTRIC DOUBLE LAYER CAPACITORS

Double Layer Capacitors. PN: NEX_ series & NED_ series

Surface Mount Multilayer Ceramic Chip Capacitors with Integrated Resistor for High Pulse Current Applications

PREFERRED RELIABILITY PRACTICES. Practice:

Transcription:

E-Guide Sample Preparation A guide to ideal sample preparation

Contents Introduction 3 1. Basic sample preparation 4 2. Non-conductive samples 5 2.1 Use of conductive coating 2.2 Low vacuum 2.3 Sputter coating 3. Magnetic samples 7 3.1 Stigmation correction 3.2 Demagnetization 4. Beam sensitive samples 8 4.1 Beam settings 4.2 Sputter coating 4.3 Cooling 4.4 Time 4.5 Magnification 5. Powders and particles 9 5.1 Particles disperser 6. Samples containing moist or outgassing samples 11 6.1 Force drying 6.2 Critical point drying 6.3 Cooling 6.4 Low vacuum E-Guide Sample Preparation 2

Introduction Sample preparation is crucial to require good SEM images. Unfortunately, not all samples can be easily imaged, but this guide will help you with tips and tricks to obtain good results from the most common samples. Feel free to combine different techniques to boost the beneficial effects and do not underestimate your creativity. Scanning electron microscopes are versatile instruments and they can do much more than you would expect. This sample preparation guide is meant for those who are approaching scanning electron microscopy for the first time, or are relatively new to it. The content is valid for most commonly used types of samples. For more detailed information on specific kinds of samples, please contact your scanning electron microscope manufacturer. E-Guide Sample Preparation 3

1. Basic sample preparation Every scanning electron microscope is equipped with a sample holder or a loading chamber where the sample can be inserted. To load a sample in a scanning electron microscope, the use of aluminium stubs is recommended. These come in different sizes and are commercially available. It is crucial that the sample is firmly mounted to the surface of the stub before placing it in the sample holder or stage. To place the sample onto the pin stub, you can use: doublesided carbon sticker conductive paint conductive tape special clamping a combination of the above. It is also highly recommended that you remove all loose particles from your sample. To do this, you can: Hold the aluminium stub with tweezers, tilt it by 90 and gently tap it on its side. Spray dry air on the sample. Always remember to take the following precautions: Be careful while handling your sample to prevent damage. Always use tweezers to prevent contamination. Make sure that the mounting procedure is reliable so that you do not introduce mechanical vibrations. DO NOT spray dry air in the direction of any electronics or scanning electron microscopes, as it might cause fire hazards. Make sure there is no condensed liquid in your spray air straw by first spraying away from your sample. These precautions will dramatically reduce the risk of contamination of your system and sample holder and guarantee better performance over time. If you deal with any of the samples on the following list, please refer to the dedicated section of this guide for suggestions on how to get the best images. Non-conductive samples Magnetic samples Beam sensitive samples Powders and particles Samples containing moist or outgassing samples. E-Guide Sample Preparation 4

2. Non-conductive samples When a non-conductive material is imaged, the electrons accelerated onto the sample don t have a path to the ground potential and will accumulate on the surface. This will result in a progressively increasing brightness in the image, until all the details are no longer visible. In worst case, the entire field of view will turn white. Minor movement can also be detected, caused by the interaction between the electrons. This will cause blurriness in the collected image. Several solutions are widely used: 2.1 Conductive tape or paint By covering part of the sample with a piece of conductive tape (e.g. copper tape) or some conductive paint, a bridge circuit to the surface of the aluminium stub is created. This will allow the sample to partially discharge and is enough to image non-conductive samples when imaging areas close to the tape edge. 2.2 Low vacuum Lowering the vacuum level introduces air molecules into the sample chamber which interact with the electron beam. Positive ions are generated and are being attracted by the sample surface. The interaction between the negatively charged electron and the positively charge ions will lead to the discharging of the sample. This technique adds some noise to the final image, but allows you to analyse the sample without further processing it, making the analysis faster and inexpensive (no additional instrumentation is needed). Fig. 1 SEM image of sugar cube charging Fig. 2 SEM image of sugar cane in low vacuum E-Guide Sample Preparation 5

2.3 Sputter coating By sputter coating, it is possible to create a thin layer of conductive material on the sample s surface. This creates a connection between the sample and the surface of the aluminium pin and therefore a bridge circuit to the ground potential. The choice of the coating material is strongly dependent on what kind of analysis needs to be performed on the sample. Gold or Platinum, due to their extremely high conductivity, are the ideal elements for high resolution images. Lighter elements, such as Carbon, can be used when EDS analysis on non-organic samples is required. ITO (indium - doped tin oxide) can create transparent, conductive layers, and can be used on glasses used often in other microscopic methods to make them suitable for SEM. The disadvantage of using a sputter coater is that additional instrumentation is required, the analysis becomes more time consuming and the samples undergo more pumping cycles. In addition, any advantage of using a BSD detector to image the sample is lost, as the contrast becomes very homogeneous and there is no difference in grey intensity for different elements. Fig. 3 SEM image of paper with no precaution (charging) Fig. 4 SEM image of paper in low vacuum mode Fig. 5 SEM image of paper with gold coating E-Guide Sample Preparation 6

3. Magnetic samples Samples that generate a magnetic field can interfere with the electron beam, reshaping it and consequently producing deformed images, usually elongated along one axis and blurry. This problem is known as astigmation and consists of an increase in the eccentricity of the beam cross section. 3.1 Stigmation correction All scanning electron microscopes offer the possibility to tune for astigmation. Certain instruments require the user to fix stigmation values every time, others can store standard values that are valid for most samples. Fig. 6 Astigmatic image of tin balls Fig. 7 SEM image of tin balls in focus Astigmatic image of tin balls. The procedure alters the lenses magnetic field which are responsible for beam reshaping. Only in the case of a circular beam shape, the best image can be produced. When changing the stigmation, it will be necessary to fine-tune the focus again. 3.2 Demagnetization Sometimes the magnetic field is just too extreme and stigmation correction will not inhance the outcome. In these cases, a demagnetizer can be used. This device can reduce the magnetic field of the sample to a level where the SEM can be used for imaging without further changes. E-Guide Sample Preparation 7

4. Beam sensitive samples Delicate samples, as for instance thin polymeric foils or biological samples, can be damaged by the electron beam due to either heat generated in the interaction area or the rupture of chemical bonds. This will result in either a hole in the observed structure or a progressive deformation of the scanned area. 4.1 Beam settings The easiest way to reduce this effect is to use lower values for acceleration voltage and current. In these cases, the smallest possible values are recommended. 4.2 Sputter coating In the worst cases, a thin coating layer can be applied to the sample in order to shield the sensitive surface. Increased conductivity will also improve image resolution. 4.3 Cooling Thermal effects can be reduced by using a temperature-controlled device. Removing the heat generated by the beam will protect the sample from thermal-induced surface modifications. 4.4 Time Spending a long time on a specific position might cause damage to the sample, over time. Being agile during the analysis will prevent excessive alterations, but might not produce the best results in terms of image quality. 4.5 Magnification Zooming-in implies having the same number of electrons shot on a smaller surface area. The thermal drift therefore my be increased and the deformation effects will become more evident. Whenever possible, low magnification is recommended. E-Guide Sample Preparation 8

5. Powders and particles When imaging particles, information as for instance particle size or shape are crucial for the design of the process flow. The easiest way to prepare a powder or particles sample is to collect a small amount of sample with a spoon and let it fall on a carbon double-sided sticker, removing the excess particles later using spray air. Unfortunately, this method will cause many particles to overlap, hiding important features, or to be blown off, introducing errors in particle counting routines. 5.1 Particles disperser The best way to prepare a powder sample is by using a particle disperser unit. This will allow an homogenous distribution of the sample on the sticker, reducing the chances of having of overlapping particles and generating a pattern that can be used for granulometry. Fig. 8 SEM image of powder. SEM images of powder Fig. 9 SEM image of powder sample using a disperser. samples using a simple method. When using a disperser the particles are easy to detect and evenly spread. Operational parameters, such as the vacuum level and the amount of sample needed, depend largely on the nature of the powders. Some general guidelines: Delicate samples might break due to strong pressure outburst. Hydrophilic samples might need a higher vacuum burst to be separated. E-Guide Sample Preparation 9

6. Samples containing moist or outgassing samples As electron microscopes operate in high vacuum levels, every wet sample which is loaded in the imaging chamber will outgas. Certain samples have microstructures that will resist the phase change, providing excellent results without major concerns. A typical example is a fresh leaf. If the sample does not have a rigid structure, it can be imaged, in case that one of the following techniques is used to prepare it. 6.1 Force drying To verify whether the sample will resist the vacuum, the use of another instrument, such as a desiccator or a sputter coater, is recommended. Eventual changes in the sample should be immediately noticeable. 6.2 Critical point drying Critical point drying (also known as supercritical point drying) describes a process in which liquid is transformed into gas to dry up samples. This either can be done with low temperatures and low pressures or high temperatures and high pressures. The last option tries to circumvent a phase change while passing a supercritical state. 6.3 Cooling Cooling is an alternative to drying techniques to preserve the structure of the sample completely intact by freezing the sample. If the phase change is quick enough, the liquids in the sample will not build crystals and the structure will be perfectly preserved. It is important to consider that the phase change is not permanent and a prolonged exposure to a high vacuum will increase the evaporation rate. Fig. 10 SEM image of a cucumber s intact structure. Fig. 11 SEM image of a tomato s peel and inside structure. E-Guide Sample Preparation 10

6.4 Low vacuum If the sample does not have a particularly high moisture content, using a small amount of sample at a reduced vacuum level can turn out to be enough to obtain images. The overall image quality will be lower, but the sample can be imaged in its original state. Fig. 12 & 13 SEM images of Nutella E-Guide Sample Preparation 11

Phenom-World BV, Dillenburgstraat 9T, 5652 AM Eindhoven, The Netherlands, www.phenom-world.com 2017. Specifications and prices are subject to change without notice. All rights reserved. Reproduction, copying, usage, modifying, hiring, renting, public performance, transmission and/or broadcasting in whole or in part is prohibited without the written consent of Phenom-World BV. Find your Phenom-World contact information at www.phenom-world.com