HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

Similar documents
HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Acclaim HPLC and UHPLC Columns

Application Specific HPLC and UHPLC Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Acclaim HPLC and UHPLC Columns

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

for Acclaim Trinity TM P1

Acclaim Mixed-Mode WCX-1

Analysis - HPLC A.136. Primesep 5 µm columns B.136

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode WCX-1

Sample Preparation TLC Plates

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Packings for HPLC. Packings for HPLC

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

groups I and II cations, amines, divalent transition metals

Alltech Alltima HP Introduction

Thermo Scientific Acclaim Surfactant Plus Column

Acclaim Mixed-Mode WAX-1 Columns

Comparison of different aqueous mobile phase HPLC techniques

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited

Method Development Kits

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

LC Columns with Liquid Separation Cell Technology

Small Molecule Selectivity Sampler

penta-hilic UHPLC COLUMNS

New Developments in Surfactant Analysis Using HPLC

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

LC and LC/MS Column Selection Flow Chart

How proteins separate on reverse-phase HPLC

IC Columns Introduction

Acclaim HILIC-10 Columns

penta-hilic UHPLC COLUMNS

LIQUID CHROMATOGRAPHY

LC Technical Information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

It s hot! ZIC -chilic

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Fluophase and Fluofix Columns

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

New Product Update. HPLC Columns

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Optimisil HPLC & UPLC Column catalogue

Strength in Technology

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Method Development with ZirChrom's Ion Exchange Phases

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

1.7µm Fortis UHPLC Columns

Cation Exchange HPLC Columns

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Technical Guide Thermo Scientific Syncronis HPLC Columns

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

columns IonPac AS18 Anion-Exchange Columns

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Too Polar for Reversed Phase What Do You Do?

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

columns IonPac AS22 Anion-Exchange Column

Dionex IonPac AS28-Fast-4µm column

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Saccharides and Organic Acids

Chiral Columns for enantiomer separation by HPLC

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Acclaim AmG C18 Column

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Ultra Inert Base Deactivated HPLC Columns

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

columns IonPac AS17-C Anion Exchange Column

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

8. Methods in Developing Mobile Phase Condition for C18 Column

1.7 m Fortis UHPLC Columns

Cation Exchange HPLC Columns

Shodex TM ODP2 HP series columns

Advantages of polymerbased. an alternative for ODS

Liquid Chromatography

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC

Transcription:

HICHROM Chromatography Columns and Supplies LC COLUMNS Thermo Scientific Acclaim Catalogue The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0) 0 0 Fax: + (0) Email: sales@hichrom.co.uk www.hichrom.co.uk

Acclaim TM Ultra-pure, porous spherical silica Novel surface chemistries for different selectivities LC-MS compatible Wide range of phases Acclaim TM HPLC columns, developed by Dionex, are now sold under the Thermo Scientific brand. Acclaim phases are based on high purity, porous silica particles (., and μm), with advanced and innovative column bonding technologies. This provides complementary selectivity, high column efficiencies and symmetrical peaks. Columns for reversed-phase, HILIC, mixed-mode and application specific analyses are available. Acclaim Reversed-Phase and HILIC Phases Acclaim Phase Chemistry Endcapped Particle Size (μm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) ph Range 0 C C Yes.,, 0 00-00 C C Yes 00 00. -. C C Yes.,, 0 00 - C0 C0 Yes, 00 00 - Phenyl- Alkyl aromatic Yes 0 00 - PolarAdvantage Embedded sulphonamide Yes.,, 0 00 - PolarAdvantage ll Embedded amide Yes.,, 0 00. - 0. HILIC-0 Proprietary No 0 00 - Acclaim RSLC.μm columns for Rapid Separation Liquid Chromatography are designed for high throughput, high efficiency separations and are compatible with UHPLC and standard HPLC systems. Acclaim C0 is designed to provide high shape selectivity for separating hydrophobic structurally related isomers and unique selectivity complementary to other reversed-phase columns. It is compatible with highly aqueous eluents. Acclaim PolarAdvantage (PA) features a patented bonding chemistry that incorporates a polar sulphonamide group with an ether linkage near the silica surface. Acclaim PA columns are compatible with 00% aqueous eluents and offer unique selectivity and good peak shape for acidic, basic and neutral analytes. Figure shows the fast analysis of phenols according to EPA Method 0. Acclaim PolarAdvantage ll (PA) columns feature a patented surface chemistry that incorporates an amide-embedded polar group and multi-point attachment between the ligands and silica surface. This unique chemistry provides enhanced hydrolytic stability from ph. to 0. with 00% aqueous eluents. Acclaim PA is specifically designed to withstand high ph conditions, making it a good choice for the separation of both basic and acidic analytes. Acclaim HILIC-0 is designed for separating highly hydrophilic molecules by HILIC. The phase is based on high purity silica covalently modified with a proprietary hydrophilic layer. Acclaim HILIC-0 is compatible with up to 0% aqueous eluent, while maintaining affinity for polar analytes. Columns can be operated in the primary HILIC mode or, alternatively, in normal-phase mode. Figure shows class separation by normal-phase, where triglycerides elute using % IPA, diglycerides using % IPA and monoglycerides using % IPA. Column: Acclaim RSLC PolarAdvantage (.μm, 0 x mm) Eluent: A: 0mM formic acid + 0mM ammonium formate, ph. B: CH CN Gradient: 0 0% B for. to.0min Flow rate:.ml/min Temperature: 0 C Detection: UV, 0nm. Phenol.,-Dinitrophenol. -Nitrophenol. -Chlorophenol. -Nitrophenol.,-Dimethylphenol.,-Dinitro--methylphenol. -Chloro--methylphenol.,-Dichlorophenol 0.,,-Trichlorophenol. Pentachlorophenol Column: Acclaim HILIC-0 (μm, 0 x.0mm) Eluent: A: Heptane B: -Propanol acetic acid (.: 0.) Gradient: Step elution Flow rate: 0.ml/min Temperature: C Detector: Corona discharge. Tristearin. Trilaurin. Diastearin isomer. Dilaurin isomer. Distearin isomer. Dilaurin isomer. Monostearin. Monolaurin 0 0 0..0..0. Mins.0 Figure. Phenols EPA 0 fast analysis 0 Mins 0 Figure. Separation of glycerides on Acclaim HILIC-0 www.hichrom.co.uk sales@hichrom.co.uk Tel: 0 0 0

Acclaim TM Mixed-Mode Phases Mixed-mode columns provide a unique, adjustable selectivity tool, using variation in ph, ionic strength or organic modifier to influence the separation selectivity of acids, bases, zwitterions and neutral molecules. Acclaim TM Mixed-Mode Phases Acclaim Phase Retention Mechanism Particle Size (μm) Pore Size (Å) Surface Area (m /g) ph Range Mixed-Mode WAX- RP + WAX + cation exclusion + HILIC, 0 00. -. Mixed-Mode WCX- RP + WCX + HILIC, 0 00. -. Mixed-Mode HILIC- RP + HILIC, 0 00. -. Trinity P SCX + WAX + RP 00 00. -.0 Acclaim Mixed-Mode WAX- is a novel phase, combining hydrophobic and weak anion-exchange characteristics. Selectivity can be adjusted by changing ionic strength, ph or organic solvent content. The surface of the phase consists of a hydrophobic alkyl chain with a tertiary amine group at the terminus. The hydrophobic moiety provides reversed-phase retention and the terminal amino group facilitates electrostatic interactions. Acclaim Mixed-Mode WCX- is manufactured by bonding a specially designed proprietary ligand with both hydrophobic and weak cation-exchange properties. The phase can separate compounds using multiple separation modes: reversed-phase, cation-exchange and HILIC and is ideal for the separation of basic molecules. Selectivity can be adjusted by modifying ionic strength, ph or organic solvent composition. Figure illustrates the effect of changing ph on the capacity of weak cation-exchange functionality of the phase. Acclaim Mixed-Mode HILIC- is a unique silica-based mixed-mode phase that combines both reversed-phase and HILIC properties. This combination allows both hydrophobic and hydrophilic interactions to be utilised in optimising separations. The phase consists of a hydrophobic alkyl chain with a diol group at the terminus, which enables a broader application range compared to conventional diol-based columns. Column: Acclaim Mixed-Mode WCX- (μm, 0 x.mm) Eluent: CH CN 0mM sodium phosphate (0:0) Flow rate: ml/min Temperature: 0 C Detection: UV, nm Acclaim Trinity P trimodal phase, based on Nanopolymer Silica Hybrid (NSH) technology, consists of high purity porous μm silica particles, coated with charged nanopolymer beads. The unique surface chemistry includes an inner-pore area modified with an organic layer that provides both reversed-phase and anion-exchange properties. The outer-pore surface is modified with cation-exchange functionality. The Acclaim Trinity P retains both cations and anions at the same time. Baseline separation can be achieved for both a drug and its counterions. Figure illustrates the simultaneous separation of pharmaceutical counterions on Trinity P. Figure. Changing ph with Acclaim Mixed-Mode WCX-. Benzoic acid. Naphthalene. Benzylamine Switch On Switch Off ph. ph. 0 Mins For free technical advice and support email technical@hichrom.co.uk Acclaim Trinity P Sulphonated nano-polymer beads on outer surface Anion-exchange/reversed-phase functionalities in inner-pore area Sulphonated nano-polymer beads attached to the surface Nano-polymer/silica hybrid particle Please see page for ordering information for Acclaim mixed-mode columns. Column: Acclaim Trinity P (μm, 00 x.0mm) Eluent: CH CN 0mM NH OAc, ph (0:0) Flow rate: 0.ml/min Column temperature: 0 C Detection: Corona discharge Figure. Simultaneous separation of pharmaceutical counterions. Choline. Tromethamine. Sodium. Potassium. Meglumine. Mesylate. Nitrate. Chloride. Bromide 0. Iodide 0 Mins 0

Acclaim TM Application Specific Phases Thermo Scientific Acclaim TM speciality phases are based on novel and unique chemistries and combine superior resolution with ease of use. Acclaim Phase Particle Size (μm) Pore Size (Å) ph Range Typical Applications Organic Acid (OA), 0 - Hydrophilic, aliphatic and aromatic organic acids Surfactant, 0. -. Anionic, cationic, non-ionic and amphoteric surfactants Explosives E 0 - Explosives E.,, 0. - Nitroaromatic and nitramine explosives Carbamate, 0 - Carbamate pesticides Carbonyl. 0. - DNPH derivatives of aldehydes and ketones Acclaim Organic Acid (OA) is a reversed-phase column designed for high efficiency, high throughput organic acid analysis. This phase is recommended for determining small hydrophilic organic acids, C to C aliphatic acids and hydrophilic aromatic acids. It is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths and manufacturing chemicals. Acclaim OA is compatible with 00% aqueous eluents. Figure shows the separation of a range of organic acids found in soft drink. Acclaim Surfactant is a silica-based column for separating a wide variety of surfactants, including anionic (alkylbenzene sulphonates, alkyl sulphates, alkylether sulphates), cationic (alkyl quaternary ammonium salts, benzylalkylammonium salts, pyridinium salts and quaternary imidazolium compounds), non-ionic (polyethylene glycols) and amphoteric surfactants. The phase is resistant to dewetting under highly aqueous conditions and provides excellent resolution between strongly hydrophilic compounds, such as isomers of xylene sulphonate. Figure 0 shows the separation of a mixture of surfactants. Column: Acclaim OA (μm, 0 x mm) Eluent: 0.M Na SO, ph. (with methanesulphonic acid) Flow rate: 0.ml/min Temperature: 0 C Detection: UV, 0nm 0 Figure. Analysis of organic acids on Acclaim OA. Oxalic acid. Tartaric acid. Formic acid. Malic acid. iso-citric acid. Lactic acid. Acetic acid. Citric acid. Succinic acid 0. Fumaric acid. cis-aconitic acid. trans-aconitic acid 0 0 Mins Column: Acclaim Surfactant (μm, 0 x.mm) Eluent: A: CH CN B: 0.M NH OAc, ph. Gradient: to % A in mins + 0 min hold at % A Flow rate: ml/min Temperature: 0 C Detection: ELSD 0. Chloride. Bromide. Nitrate. Xylene sulphonate. Laurylpyridinium chloride. Lauryldimethylbenzylammonium chloride. Triton X-00. Cetyl betaine. Decyl sulphate 0. Dodecyl sulphate. C0-LAS. C-LAS. C-LAS. C-LAS 0 0 0 0 Mins Figure 0. Separation of mixture of surfactants Acclaim Explosives E and E columns are specifically designed to resolve all explosives listed in EPA Method 0 (nitroaromatics and nitroamines). The Acclaim Explosives E column is recommended for use as direct replacement for C columns for the primary analysis. The Acclaim Explosives E offers complementary selectivity and may be used as either a primary or a confirmatory column. Acclaim Carbamate columns are designed for baseline separation of carbamate pesticides in drinking water and raw surface water, as specified in US EPA Method.. It is used in conjunction with post-column derivatization and fluorescence detection or LC-MS. Acclaim Carbonyl is a reversed-phase column designed specifically for separating DNPH derivatives of aldehydes and ketones, regulated by various official methods. It has a particle size of.μm, suitable for high efficiency UHPLC performance. Please see page for ordering information for Acclaim columns. www.hichrom.co.uk sales@hichrom.co.uk Tel: 0 0 0

Please contact Hichrom for current prices. Tel: + (0) 0 0 Email: sales@hichrom.co.uk Thermo Scientific Ordering Information Acclaim TM Please contact Hichrom for ordering information for.μm particle size columns and column dimensions not listed below. Acclaim Reversed-Phase and HILIC Columns Acclaim Phase Column Dimensions (mm) Guard Cartridges μm 0 x. 00 x. 0 x. 0 x. 0 x.mm (/pk) 0 C 0 0 00 0-0 C 0 0 0 0 - C0 - - 0-0 0 Phenyl- 00 00 0 00 0 0 PA (PolarAdvantage) 0 0 0 0 - PA (PolarAdvantage ll) 0 0 0 0 - HILIC-0 - - 0 - - μm 0 C 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 Acclaim Phase Column Dimensions (mm) Guard Cartridges μm 0 x. 00 x. 0 x. 0 x. 0 x.mm (/pk) 0 C 0 0 0 - - 0 C 0 0 0 - - C0 - - 0-00 0 Phenyl- 00 00 0-0 0 PA (PolarAdvantage) - 0 0 - - PA (PolarAdvantage ll) 0 000 0 - - HILIC-0 - - 0 - - μm 0 C 0 0 0 0 0 0 0 C 0 0 0 00 0 0 C0 - - 0 0 - PA (PolarAdvantage) 0-00 0 0 PA (PolarAdvantage ll) - - 0 0 0 Other column dimensions available Use with guard cartridge holder V-, p/n 00 ( 0) and column coupler V- p/n 0 ( ) Acclaim Mixed-Mode Phases Phase Column Dimensions (mm) μm 0 x. 00 x. 0 x. 0 x.0 0 x.0 Mixed-Mode WAX- - - 000 00 000 Mixed-Mode WCX- - - 000 00 000 Mixed-Mode HILIC- - - 000 0 0000 Trinity P 0 0 0 0 0 0 0 0 For free technical advice and support email technical@hichrom.co.uk Phase Column Dimensions (mm) Guard Cartridges Guard Cartridges μm 0 x. 0 x. 0 x. 0 x.mm (/pk) 0 x.mm (/pk) Mixed-Mode WAX- 00 0 0 0 0 0 00 0 Mixed-Mode WCX- 0 0 0 0-00 0 Mixed-Mode HILIC- 0 0 0 0 0 0 00 0 Acclaim Speciality Phases Phase Column Dimensions (mm) μm 0 x. 0 x.0 0 x.0 0 x. Organic Acid 000 000 - - Surfactant 000 000 - - Explosives E 000 000 000 0 - Carbamate 0 0-0 Phase Column Dimensions (mm) Guard Cartridges Guard Cartridges μm 0 x. 0 x. 0 x. 0 x.mm (/pk) 0 x.mm (/pk) Organic Acid - 00 00 0-000 Surfactant 0 00 00 0 0 0 00 Explosives E - - 00-00 Explosives E - - 00-00 Carbamate - - 0 0 00 0 0 0 Other dimensions available Use with guard cartridge holder V-, p/n 00 ( 0) and column coupler V- p/n 0 ( ) Please enquire for ordering information for Acclaim Carbonyl columns.0mm i.d.