An Adaptive Chimney Stack for Noise Control

Similar documents
Transmission Matrix Model of a Quarter-Wave-Tube with Gas Temperature Gradients

Impedance correction for a branched duct in a thermoacoustic air-conditioner

Transmission Matrix Model of a Quarter-Wave-Tube with Gas Temperature Gradients

IMPROVEMENTS IN ACTIVE NOISE CONTROL OF HELICOPTER NOISE IN A MOCK CABIN ABSTRACT

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 NUMERICAL SIMULATION OF THE ACOUSTIC WAVES PROPAGATION IN A STANDING WAVE TUBE

Effect of effective length of the tube on transmission loss of reactive muffler

PASSIVE NOISE CONTROL OF A BURNER-COMBUSTOR SYSTEM OF A TURBO-FAN ENGINE

The Corrected Expressions for the Four-Pole Transmission Matrix for a Duct with a Linear Temperature Gradient and an Exponential Temperature Profile

HELMHOLTZ RESONATORS FOR DAMPING COMBUSTOR THERMOACOUSTICS

Active Minimization of Acoustic Energy Density to Attenuate Radiated Noise from Enclosures

Reactive Silencer Modeling by Transfer Matrix Method and Experimental Study

Proceedings of Meetings on Acoustics

Effect of Length and Porosity on the Acoustic Performance of Concentric Tube Resonators

Fan duct noise elimination by the use of helicoidal resonators

Design of Mufflers and Silencers. D. W. Herrin, Ph.D., P.E. University of Kentucky Department of Mechanical Engineering

Design of Partial Enclosures. D. W. Herrin, Ph.D., P.E. University of Kentucky Department of Mechanical Engineering

A METHOD OF ADAPTATION BETWEEN STEEPEST- DESCENT AND NEWTON S ALGORITHM FOR MULTI- CHANNEL ACTIVE CONTROL OF TONAL NOISE AND VIBRATION

American International Journal of Research in Science, Technology, Engineering & Mathematics

Vibration Generations Mechanisms: Flow Induced

Chapter 10 Sound in Ducts

Sound radiation and transmission. Professor Phil Joseph. Departamento de Engenharia Mecânica

Helmholtz resonator with multi-perforated plate

PHY 103 Impedance. Segev BenZvi Department of Physics and Astronomy University of Rochester

Sound radiation from the open end of pipes and ducts in the presence of mean flow

USE OF RESONANCE AND ANTI RESONANCE FREQUENCY SHIFTS TO LOCATE AND SIZE HOLES IN PIPE AND DUCT WALLS

AEROACOUSTIC INVESTIGATION OF THE EFFECT OF A DETACHED FLAT PLATE ON THE NOISE FROM A SQUARE CYLINDER

The sound power output of a monopole source in a cylindrical pipe containing area discontinuities

Transmission Loss Assessment for a Muffler by Boundary Element Method Approach

Acoustic coupling between cascade sub-chambers and its influence on overall transmission loss

New Recursive-Least-Squares Algorithms for Nonlinear Active Control of Sound and Vibration Using Neural Networks

I. INTRODUCTION II. COMPUTATIONAL MODEL AND THEORY

Sound radiation of a plate into a reverberant water tank

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

MEASUREMENT OF INPUT IMPEDANCE OF AN ACOUSTIC BORE WITH APPLICATION TO BORE RECONSTRUCTION

Sound Transmission in an Extended Tube Resonator

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Iterative Controller Tuning Using Bode s Integrals

PART VIII: ABSORPTIVE SILENCER DESIGN

Statistical errors in the estimation of time-averaged acoustic energy density using the two-microphone method

PHY 103 Impedance. Segev BenZvi Department of Physics and Astronomy University of Rochester

Introduction to Acoustics. Phil Joseph

IMPROVING THE ACOUSTIC PERFORMANCE OF EXPANSION CHAMBERS BY USING MICROPERFORATED PANEL ABSORBERS

To study the acoustic normal modes of air-filled cavities of rectangular and cylindrical geometry.

Suction Muffler Optimisation in a Reciprocating Compressor

Impedance Measurement of a Thermoacoustic Engine Constructed from a Helmholtz Resonator

Scattering Parameters

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

Engineering Noise Control

Improvements of a parametric model for fan broadband and tonal noise

Investigation of Passive Control Devices for Potential Application to a Launch Vehicle Structure to Reduce the Interior Noise Levels During Launch

1 Introduction. 2 Data Set and Linear Spectral Analysis

ERRATA AND ADDITIONS FOR "ENGINEERING NOISE CONTROL" 4th Edn. First printing April 23, 2018

Application of a Helmholtz resonator excited by grazing flow for manipulation of a turbulent boundary layer

Sound Pressure Generated by a Bubble

Acoustics of Suction Mufflers in Reciprocating Hermetic Compressors

Measures and sources of sound. Professor Phil Joseph

On determination of microphone response and other parameters by a hybrid experimental and numerical method

Acoustic Resonance in Main Steam Line Side Branches

ICSE QUESTION PAPER Class X Physics (2016) Solution

AN ALTERNATIVE FEEDBACK STRUCTURE FOR THE ADAPTIVE ACTIVE CONTROL OF PERIODIC AND TIME-VARYING PERIODIC DISTURBANCES

Aeroacoustic simulation of automotive ventilation outlets

Noise reduction in a large enclosure using single, dual and ensconced Helmholtz resonators

University of Kentucky

Simulation of organ pipe transfer function by means of various numerical techniques

Sound Waves. Sound waves are longitudinal waves traveling through a medium Sound waves are produced from vibrating objects.

Comparison of Two Methods for Measurement of Horn Input Impedance

Wojciech ŁAPKA, Czesław CEMPEL

Modelling and optimisation of acoustic inertance segments for thermoacoustic devices

arxiv: v1 [physics.class-ph] 22 Sep 2008

An investigation of Rubens flame tube resonances a)

Horns as particle velocity amplifiers

GENERAL PHYSICS (3) LABORATORY PHYS 203 LAB STUDENT MANUAL

! 2 = k a ! = 125, Problems and Solutions Section 5.3 (5.27 through 5.36)

FastBEM Acoustics. Verification Manual , Advanced CAE Research, LLC (ACR) Cincinnati, Ohio, USA All Rights Reserved

SIMULATION OF ORGAN PIPES ACOUSTIC BEHAVIOR BY MEANS OF VARIOUS NUMERICAL TECHNIQUES

EXPERIMENTAL INVESTIGATION OF NOISE PARAMETERS IN HVAC SYSTEMS

ON SITE DETERMINATION OF SOUND ABSORPTION COEFFICIENT OF ROAD PAVEMENTS USING MOBILE LABORATORY

Principles of Convection

Producing a Sound Wave. Chapter 14. Using a Tuning Fork to Produce a Sound Wave. Using a Tuning Fork, cont.

Flow control. Flow Instability (and control) Vortex Instabilities

17. Investigation of loudspeaker cabinet vibration using reciprocity

The directivity of the forced radiation of sound from panels and openings including the shadow zone

Gas Dynamics: Basic Equations, Waves and Shocks

Estimating received sound levels at the seafloor beneath seismic survey sources

H -Control of Acoustic Noise in a Duct with a Feedforward Configuration

Investigations of a Tuned Vibration Absorber with High Damping for Increasing Acoustic Panels Sound Transmission Loss in Low Frequency Range

Introduction to Acoustics Exercises

BOUNDARY CONDITION FOR THE ACOUSTIC IMPEDANCE OF LIGHTWEIGHT MICRO PERFORATED PANELS AND MEMBRANES

Muffler Transmission Loss Simple Expansion Chamber

Empirical study of the tonal noise radiated by a sharpedged flat plate at low-to-moderate Reynolds number

Transmission Loss of a Dissipative Muffler with Perforated Central Pipe

Experiments in active control of panel vibrations with spatially weighted objectives using multiple accelerometers

Acoustic Impact of Fire Suppression Nozzles

Noise in enclosed spaces. Phil Joseph

Problem 10 Rijke s tube Team «12FM», Novosibirsk Artem Redko

A Modal Approach to Lightweight Partitions with Internal Resonators

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

AN OVERVIEW OF DYNAMIC PRESSURE MEASUREMENT CONSIDERATIONS

Chapter 10: Vibration Isolation of the Source

Fan Noise Control by Enclosure Modification

Transcription:

9- November 2005, Busselton, Western Australia An Adaptive Chimney Stack for Noise Control M. R. F. Kidner and B. S. Cazzolato () Active Noise and Vibration Control Group, Dept. Mechanical Engineering University of Adelaide SA 5006. ABSTRACT Radiation of noise from exhaust stacks is a significant source of community disturbance. In this paper an exhaust stack with an adaptive length is proposed. The effective length of the stack is changed by altering the level of water in a sump at the base of the stack, this level is controlled as a function of the radiated noise from the top of the stack. The system is modelled as a pipe with an adaptive side branch. A gradient descent algorithm is used to minimise the radiated sound. The response to a step change in frequency and a chirp signal is shown. A simple heuristic controller is compared to the performance obtained with the gradient descent algorithm and is shown to be acceptable and computationally simpler. INTRODUCTION One of the significant sources of community disturbance is noise radiation from exhaust stacks, this noise is tonal in nature and so is heavily weighted in evaluations of annoyance (Bies 992). Retrofitting noise mitigation measures to industrial plants is very expensive and minimisation of downtime is a an important factor in keeping costs low. The adaptive noise control approach suggested here would be applicable to many exhaust stacks because of the controller simplicity, an installation that does not interfere substantially with the exhaust stack operation and the small number of electro-acoustic transducers required. Side branches in exhaust systems have been used to reduce noise, (Kinsler 999), but also have been identified as noise sources (Selemat 996), the noise created being a function of sidebranch length and cross sectional area. An adaptive passive control system for noise in ducts has been proposed by Kostek (Kostek 999) and has been used effectively to control noise. In this work the stack length is changed using an extendable section. This approach can achieve a larger range of operation frequencies but is expensive as the entire stack needs to amended. The adaptive stack proposed here can be modeled as an open-ended pipe with a variable length side branch attached, see Figure (). THEORETICAL PERFORMANCE OF THE CONTROLLER In this section we develop a model of the plant and design a controller. First, the radiation from a pipe as a function of its length is determined, from this an appropriate controller is designed. Radiation from an open pipe with a side branch The sound power radiated from a pipe is a function of its impedance, (Beranek 992) and the acoustic impedance of the surroundings. However it can be hard to predict for bery resonant systems, (Davis 2004), The change in the radiated sound power as a function of the drive frequency, normalised to the wavelength is shown in Figure (2). It can be seen that there is a strong dependence on the length of the side branch. However it is not a linear relationship between side branch length and raidated sound power. The model of the exhaust system was developed using transfer matrixes after Beranek &Ver. The transfer matrix, that relates pressures and mass flow rates for a section of pipe can be written as T pipe = T T 2 cos(k c l) jy 0 sin(k c l) = e jk c Ml j sin(k c l) T 2 T 22 cos(k c l) Y 0 (). where k, c, and l are the wavenumber, sound speed and length of the pipe section respectively. The Mach number of the flow in the pipe is indicated by M. Y 0 is defined by c/s 0, the ratio of sound speed to the cross sectional area of the pipe. So that p 2 = T p ρsu 2 ρsu (2) where p is the pressure and u the particle velocity. The density of the fluid and cross sectional area of the pipe is indeicated by ρ and S respectively. For a side branch resonator the transfer impedance is given by Equation (3) 0 T r = + Z c where, the throat impedance and Z c, the cavity impedance of a side branch tube, are defined as = ck 2 π + j ck(l +.7r ) c 0 Z c = j c cot(kl c ) S 0 S c where r and S 0 are the radius of the branch and the cross sectional area of the side branch respectively. The lengths of the throat and the the length of the side branch itself are indicated by l t and l c. From these equations the pressure radiated from the end of the pipe, shown in Figure () can be calculated by multiplication of the transfer matrices for each section. (3) (4) Australian Acoustical Society 59

9- November 2005, Busselton, Western Australia Proceedings of ACOUSTICS 2005 P 3 = T 3 T 2 T P (5) The overall transfer matrix for the exhaust stack can be written as T = T 3 T 2 T (6) The pressure at the radiating end can be written as P 3 = T (,) p + T (,2) ρsu = (T (,) + S c T (7) (,2))p the velocity at the radiating end can be written as u 3 = ρs T (2,)p + T (2,2) ρsu = ρs T (2,) + S (8) c T (2,2) p The expression in () allows the radiated presure to be calculated, this is used to simulate the behaviour of the control system. Howvever to evaluate the system the standard calculation for the insertion loss is used. The insertion loss is calculated using equation (2). IL = 20log 0 T (,) + T (,2) + T (2,) Z s + T (2,2) Z s + Z s where T is the tranfser matrix of the system, Z s and are the source and termination impedances respectively. Possible frequency range of control From Figure (3) it can be seen that the insertion loss of a tone in the frequency range 00-200Hz could be varied by up to 40dB, depending on the length of the side branch. The peaks in insertion loss are sharp and so an accurate controller is required. Figure 2 Variation in insertion loss as a function of the length of the side pipe, normalised to wavelength. Figure 3 Insertion loss of the side branch at minimum,(solid line) and maximum, (dotted line) length. CONTROL SYSTEMS FOR THE ADAPTIVE EXHAUST STACK Figure Simplification of exhaust stack with side branch. The stack radiates into free space and so the correct radiation impedance should be included. At the radiating end of the stack the following relationship must hold: p rad = Z r U rad (9) where, U rad = Su 3, the volume velocity at the radiating end, and p rad +p 3 =0. Therefore the radiating pressure can be written as p rad = Z r Su 3 = Z rad T (2,) + ρs c T (2,2) p () We will consider two control alagortihms, one gradient based and the other rule based. The gradient descent algorithm should give results that indicate a best case scenario, however it is not the most practical controller because the gradient calculation requires additional alterations of the side branch length. This may result in undesirable fluctuations in the radiated sound power as the system converges. The rule based method is far simpler, but may have slower convergence rate and a higher steady state error. It is also likely to require more tuning to obtain good performance. These factors will be discussed in the following sections. A general control flow diagram is shown in Figure (4), in this system the control action is a function of the error magnitude and the gradient of the error with respect to the length of the side branch. The gains G p and G d control the contribution of the proportional and derivative part. The system H is the water pump, and is modelled as an integrator. The length of side branch is limited between L min and L max, so there is some non-linear behaviour at these extremes. The value of <p 2 > is then used to adjust the overall exhaust stack transfer function 60 Australian Acoustical Society

. It is important to note the the error is the mean squared pressure, and as such does not have a phase component. Gradient descent controller The pressure at the mouth of the exhaust stack is a function of frequency and the length of the side tubed. The pressure varies with both of these parameters in a nonlinear fashion. It is not possible to formulate the control problem in the classical sense, as the control signal, (the length of side tube), is not related to the error by a single complex gain. A gradient descent controller is proposed in which the length of the side tube is a function of the mean square pressure and the gradient of the mean square pressure with respect to the change in length. As with all gradient descent algortihms where a closed form expression for the gradient is not readily avalible the step size of the algorithm has to be manually adjusted to find the optimal value, (optimal in the sense of minimising convergence time, overshoot and steady state error). RESPONSE TO TEST SIGNALS Three test cases are used to evaluate the controller. Step change in frequency. The frequency of the source signal is changed by 0% and the convergence and steady state error is evaluated. Chirp input. The source frequency is varied by 0% over 20 seconds and the error is evaluated Sinusoidal change in frequency. The frequency varies by 0% in a sinusoidal manner over 20 seconds. 9- November 2005, Busselton, Western Australia Figure (6) shows the error in db relative to the initial value of the mean squared pressure. It can be seen that without control the error increases by 30dB at the step change in frequency. With the controller operating the error still increases momentarily but within 8 seconds is reduced to the initial level. The controller then reduces the level further by 5dB. It should be noted that the controller calculates the gradient offline, so that the variations in level due to this process are not shown in the pressure time history. Chirp Figure (9) and Figure (0) show the results for the chirp input. The chirp rate was set so that the fill rate could match the required change in length to maintain the minimum pressure radiation condition. It can be seen that as the pressure reduces due to the change in frequency, the length of the pipe does not change, however, once the pressure increases again the length of the pipe changes linearly with the change in drive frequency. The error is not reduced to its initial value, but it remains approximately 8dB less than the uncontrolled level. Sinusoidal frequency change Figure(3) and Figure(4) show the results for the chirp input. The chirp rate was set so that the fill rate could not match the required change in length to maintain the minimum pressure radiation condition. In this case the gradient descent conrtoller, becomes unstable. Reduction of the gain only reduced the performance, and at no point did the controller manage to track the disturbance and minimise the level. A HEURISTIC CONTROLLER A simple heuristic or rule based controller is proposed. The length of the side branch is governed by the following rules if new error >old error L=- L new L = old L + L The controller always adds to the branch length, unless the error increases, in this case it decreaes the length. The length is still limited between L min and L max. The pump also still acts as an integrator so that the pump rate determines how quickly the length can change. In this algorithm, the size of the length change is used to change the perfomance. Too large a value will cause the level to change far too rapidly, and the controller will fluctuate about the optimal point. This can be mitigated by a low pump rate, which will slow the repsonse of the whole system. Too small a value will cause the system to take a long time to adapt to changes in source frequency. Figure 4 General controller diagram GRADIENT DESCENT CONTROLLER. Step Change Figure (5) shows the pressure time history and the variation in the length of the side branch when the gradient descent controller is used. At 7.7 seconds the frequency of the drive signal changes from 200 to 80Hz (-0%). The step size was set to 0.025m and the fill rate, (integrator gain) was set to mm/sec. The controller acted at a rate of 8Hz. So that 0.25seconds of pressure data was used to evaluate the mean pressure squared, this is approximately 22 cycles. Step Change Figure(7) shows the pressure time history and the variation in the length of the side branch when the rule based controller is used. At the frequency of the drive signal changes from 200 to 80Hz (-0%). The step size was set to 0.025m and the fill rate, (integrator gain) was set to mm/sec. The controller acted at a rate of 8Hz. So that 0.25 seconds of pressure data was used to evaluate the mean pressure squared, this is approximately 22 cycles. Figure(8) shows the error in db relative to the initial value of the mean squared pressure. It can be seen that without control the error, it is a similar convergnce as the gradient descent algorithm. However, it should be noted that this controller is working in real time, that is no off line calculation of Australian Acoustical Society 6

9- November 2005, Busselton, Western Australia Proceedings of ACOUSTICS 2005 gradients has taken place. The error converges to the initial value by 7.7 seconds. However, the error is not reduced to less than the inital value, as was the case with the gradient descent controller. Figure 5 (a) Pressure radiated from top of stack with and without gradient descent controller as the frequency steps from 200 to 80Hz. (b) Desired length and actual length of side branch as controller adapts. Chirp Figure () and Figure(2) show the results for the chirp input. The chirp rate was set so that the fill rate could match the required change in length to maintain the minimum pressure radiation condition. It can be seen that there is more variation in the level than there was in results for the gradient control ler. It can also be seen that the changes in length are stepped,not smooth. The average level is higher than that achieved by the gradient descent controller. Sinusoidal frequency change Figure(5) and Figure(6) show the results for the rule based controller as the input frequency varies sinusoidally. In this test case the rule based controller performs better than the gradient descent based controller. The controller does not increase the level and the pressure is reduced by betwen 5 and 35dB. The variation in the side branch length can be seen to be approximately sinusoidal for part of the time history. This trend stops when the side branch length becomes zero. At this point the limiters in the controller algorithm prevent further reductions in length as a negative length is nonphysical. Figure 6 Error signal with and without gradient based controller as the frequency steps from 200 to 80Hz. CONTROL PARAMETERS The pump rate and the change in length at each control step,, need to be matched to obtain the best performance from either controller. In applications the pump rate is likely to be limited to a small range, most likely at low values for low cost systems. This will reduce the agility of the control system. However the source frequency is not expect to change rapidly and as community annoyance levels are measured over a period of hours a few minutes of adaption time will not cause an issue. Figure 7 Pressure radiated from top of stack with and without rule based controller as the frequency steps from 200 to 80Hz. (b) Desired length and actual length of side branch as controller adapts. CONCLUSIONS This paper has presented a brief investigation into a adaptive side branch for an exhaust stack. It has been shown that a simple controller can be used to maintain a minimum amount of sound radiation. The rule based controller out performed the gradient desent controller when the frequency changed in a non linear fashion. Also the rule based controller does not required the calculation of a gradient and as such is simpler and faster. Figure 8 Error signal with and without rule based controller as the frequency steps from 200 to 80Hz. 62 Australian Acoustical Society

Figure 9 Pressure radiated from top of stack with and without gradient controller as the frequency linearly changes from 200 to 60Hz. (b) Desired length and actual length of side branch as controller adapts. 9- November 2005, Busselton, Western Australia Figure 3 (a) Pressure radiated from top of stack with and without rule based controller as the frequency sinusoidally changes from 200 20Hz. (b) Desired length and actual length of side branch as controller adapts. Figure 4 Error signal with and without gradient descent controller as the frequency sinusoidal changes from 200Hz 20Hz. Figure 0 Error signal with and without gradient controller as the frequency linearly changes from 200 to 60Hz. Figure 5 Pressure radiated from top of stack with and without rule based controller as the frequency sinusoidally changes from 200 20Hz. (b) Desired length and actual length of side branch as controller adapts. Figure Pressure radiated from top of stack with and without rule based controller as the frequency linearly changes from 200 to 60Hz. (b) Desired length and actual length of side branch as controller adapts. Figure 6 Error signal with and without rule based controller as the frequency sinusoidal changes from 200Hz 20Hz. REFERENCES Figure 2 Error signal with and without rule based controller as the frequency linearly changes from 200 to 60Hz. (Bies 992) Bies, D., & Hansen, C., Engineering Noise Control Theory and Practice, Second Edition, E & FN Spon, London, 996. (Beranek 992) Beranek, L., & Ver, I., (Editors), Noise and Vibration Control Engineering Principles and Applications, Wiley Interscience, New York, 992. (Davies 2004) P. O. A. L. Davies K. R. Holland, The measurement and prediction of sound waves of arbitrary amplitude in practical flow ducts, Journal of Sound and Vibration Volume 27, Issues 3-5, 6 April 2004, Pages 849-86 (Knsler 999) Kinsler, L., Frey, A., Coppens, A., & Sanders, J., Fundamentals of Acoustics, Wiley, New York, 999 (Kostek 2000) Theodore M. Kotek, Matthew A. Franchek, Hybrid Nosie Control In Ducts Journal of Sound and Vibration Volume 237, Issue, 2 October 2000, Pages 8-00 (Selamet 996) A. Selamet P. M. Radavich,, Side branches in automotive intake systems as noise generators. The Journal of the Acoustical Society of America -- April 996 -- Volume 99, Issue 4, pp. 2460-2500 Australian Acoustical Society 63