Postprint.

Similar documents
Cruz, J., Hooshmand Zadeh, S., Wu, Z., Hjort, K. (2016) Inertial focusing of microparticles and its limitations. In: (pp. 1-6).

Geometry Induced Microparticle Separation in Passive Contraction Expansion Straight Channels

Differential inertial focusing of particles in curved low-aspect-ratio microchannels


Particle concentration influences inertial focusing in Multiorifice Flow Fractionation microfluidic devices

Supplementary Information

Calculate the total volumes of the following typical microfluidic channel dimensions.

Particle Focusing in Microchannel with Multi-Parallel Channels or Porous Orifice

Microdevices for Continuous Sized Based Sorting by AC Dielectrophoresis

Quantitative characterization of the focusing process and dynamic behavior of differently sized microparticles in a spiral microchannel

Computational Analysis for Mixing of Fluids Flowing through Micro- Channels of Different Geometries

Microfluidics 1 Basics, Laminar flow, shear and flow profiles

Ultrasonic particle and cell separation and size sorting

[Supplementary Figures]

Jurnal Teknologi APPLICATION OF ELECTRICAL CAPACITANCE TOMOGRAPHY FOR DENSE CROSS- SECTIONAL PARTICLE MIGRATION IN A MICROCHANNEL.

ENMA490 Capstone: Design of Microfluidics Mixer

Microfluidics and Lab-on-a-chip systems. Pelle Ohlsson

Supplementary Information for Microfluidic Magnetophoretic Separations of Immunomagnetically Labeled Rare Mammalian Cells

Sheathless Hydrophoretic Particle Focusing in a Microchannel with Exponentially Increasing Obstacle Arrays

Microfluidic single cell sorting and trapping using dual spiral channels

CONTINUOUS SIZE-BASED SEPARATION OF MICROPARTICLES IN STRAIGHT CHANNELS

Supplementary Figure 1: Micromechanical cleavage of graphene on oxygen plasma treated Si/SiO2. Supplementary Figure 2: Comparison of hbn yield.

A microfluidic-based hydrodynamic trap: Design and implementation

Experimental mixing characterization of Newtonian fluids mixing in asymmetric T-micromixers

Lab 7: Low Reynolds numbers and Tube Flows

Micro Cooling of SQUID Sensor

Inertial focusing in a straight channel with asymmetrical expansion-contraction cavity arrays using two secondary flows

Inertial Microfluidic Physics

Supporting information for. Microfluidic Impedance Cytometer with Inertial Focusing and. Liquid Electrodes for High-Throughput Cell Counting and

Research strategy for Micro and complex fluids

Spiral microchannel with rectangular and trapezoidal cross-sections for size based particle separation

FLOW CHARACTERIZATION WITHIN A SPHERE-PACKED BED USING PIV MEASUREMENT

Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel

A Multifunctional Pipette

Formation of Droplets and Bubbles in a Microfluidic T-junction. Scaling and Mechanism of Break-Up. Supplementary Information

On the Design and Optimization of Micro-Fluidic Dielectrophoretic Devices: A Dynamic Simulation Study

Chemistry Instrumental Analysis Lecture 31. Chem 4631

R09. d water surface. Prove that the depth of pressure is equal to p +.

Introduction to Micro/Nanofluidics. Date: 2015/03/13. Dr. Yi-Chung Tung. Outline

Three-dimensional hydrodynamic focusing with a single sheath flow in a single-layer microfluidic device

Analysis of laminar convective heat transfer in micro heat exchanger for stacked multi-chip module

Electrophoresis (EP)-modified inertial migration of particles in a straight channel with symmetric semicircle obstacle arrays

Visualization of flow pattern over or around immersed objects in open channel flow.

Electronic Supplementary Information. Continuous Flow Microfluidic-MS System for Efficient OBOC Screening

Inertial Focusing of Particles in Curved Microchannels

percolating nanotube networks

ESS 5855 Surface Engineering for. MicroElectroMechanicalechanical Systems. Fall 2010

Lecture 18: Microfluidic MEMS, Applications

Supplementary information for

Experimental measurement of parameters governing flow rates and partial saturation in paper-based microfluidic devices

Fast Biofluid Transport of High Conductive Liquids Using AC Electrothermal Phenomenon, A Study on Substrate Characteristics

Integrated measuring system for MEMS

Contents. Microfluidics - Jens Ducrée Physics: Laminar and Turbulent Flow 1

Microfluidic Devices. Microfluidic Device Market. Microfluidic Principles Part 1. Introduction to BioMEMS & Medical Microdevices.

1

Supporting Information. Technique for real-time measurements of endothelial permeability in a

The Use of COMSOL Multiphysics for Studying the Fracture Pressure of Rectangular Micro-Channels Embedded in Thin Silicon Substrates

Quantitative dynamic footprinting microscopy reveals mechanisms of neutrophil rolling

Multi-Physics Analysis of Microfluidic Devices with Hydrodynamic Focusing and Dielectrophoresis

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

Micro/nano and precision manufacturing technologies and applications

Lab on a Chip PAPER. Size-based microfluidic multimodal microparticle sorter. Introduction. Xiao Wang and Ian Papautsky*

Cells in double emulsions for FACS sorting

Optimization of Microchannel

Pressure-Driven Laminar Flow in Tangential Microchannels: an Elastomeric Microfluidic Switch

Paper No. ICMM

Drug Delivery Systems

InterPACKICNMM

Single and collective fiber dynamics in micro-flows. Anke Lindner, PMMH-ESPCI, Paris, France

Concentrated suspensions under flow in microfluidic channel and migration effect

Enhanced size-dependent trapping of particles using microvortices

Microfluidic biosensor for single cell high speed flow impedance spectroscopy

Chromatography. What is Chromatography?

Experimental determination of sample stream focusing with fluorescent dye

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

Quantitative Measurement of Sweat as a Diagnostic. Abstract

The Coulter Principle for Outlier Detection in Highly Concentrated Solutions

Simulation of CMOS compatible sensor structures for dielectrophoretic biomolecule immobilization

Continuous focusing and separation of microparticles with acoustic and magnetic fields

Experimental Investigation of Heat Transfer Characteristics on a Gas-to- Gas Parallel Flow Microchannel Heat Exchanger

Particle removal in linear shear flow: model prediction and experimental validation

Microstructured Porous Silica Obtained via Colloidal Crystal Templates

FRAUNHOFER INSTITUTE FOR SURFACE ENGINEERING AND THIN FILMS IST ATMOSPHERIC PRESSURE PLASMA PROCESSES

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Fluid Flow and Heat Transfer of Combined Forced-Natural Convection around Vertical Plate Placed in Vertical Downward Flow of Water

Coflore Agitated Cell Reactor

ChromTech options for PAL systems

Entropic Evaluation of Dean Flow Micromixers

Supplementary Methods

Supplementary Informations Spatial cooperativity in soft glassy flows

SUPPLEMENTARY INFORMATION

Figure 3: Problem 7. (a) 0.9 m (b) 1.8 m (c) 2.7 m (d) 3.6 m

Fluidic low pass filter for hydrodynamic flow stabilization in microfluidic environments

Solder Self-assembly for MEMS

Supplementary Methods

Fluid Mechanics. du dy

Supplementary Material (ESI) for Journal of Analytical Atomic Spectrometry This journal is The Royal Society of Chemistry 2010

Deformability-Selective Particle Entrainment and Separation in a Rectangular Microchannel Using Medium Viscoelasticity

Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions

Postprint.

Transcription:

http://www.diva-portal.org Postprint This is the accepted version of a paper presented at 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), 2011. Citation for the original published paper: Hansson, J., Karlsson, J., Haraldsson, T., Wijngaart, W., Russom, A. (2011) Inertial Particle Focusing In Parallel Microfluidic Channels For High-Throughput Filtration. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), 2011 (pp. 1777-1780). IEEE conference proceedings http://dx.doi.org/10.1109/transducers.2011.5969458 N.B. When citing this work, cite the original published paper. 2011 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. Permanent link to this version: http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-48371

INERTIAL PARTICLE FOCUSING IN PARALLEL MICROFLUIDIC CHANNELS FOR HIGH-THROUGHPUT FILTRATION J. Hansson 1, J.M. Karlsson 2, T. Haraldsson 2, W. van der Wijngaart 2, A. Russom 1 1 Div. Cell Physics, Dept. Applied Physics, KTH Royal Institute of Technology, Stockholm, SWEDEN 2 Microsystem Technology Lab, KTH Royal Institute of Technology, Stockholm, SWEDEN ABSTRACT In this study, we introduce inertial microfluidics in straight, parallel channels for high-throughput particle filtration. We show that particles flowing through low aspect ratio rectangular microchannels can be focused into four particle streams, distributed at the centers of each wall face, or into two particle streams, at the centers of the longest channel walls, depending on the particles size. For high-throughput filtration, we fabricated scalable, single inlet and two outlet, parallel channel microdevices, using a high-density 3D microfluidic PDMS channel manufacturing technology, in a design that allows for easy integration with other downstream on-chip functions we recently described. We demonstrate filtration of 24 µm particles from a suspension mixture in a microdevice with four parallel channels. The filtration efficiency at a non-optimized flow rate of 0.8 ml/min was 82%. KEYWORDS: Inertial microfluidics, inertial focusing, 3D fluidic networks, PDMS, particle filtration. INTRODUCTION The possibility to control the position of particles in continuous flow in microfluidic channels at very high throughput opens the door to the development of a large set of bioanalytical applications, such as blood cell separation and pathogen isolation. Very recently, inertial-induced forces developed in microchannels have been proposed by ourselves and others as a promising approach for particle focusing, filtration and separation [1][2][3]. In inertial microfluidics, lift forces act on particles and force them across streamlines towards particle size dependent equilibrium positions. Since inertial microfluidics rely on focusing many particles into a few particle streams, particle-particle interaction puts a limitation on the total particle volume fraction often kept below 1%. For practical blood cell separation applications, the sample needs to be diluted, which limits the total volumetric flow rate. A straightforward way of increasing throughput is through parallelization. 3D fluidic networks allow the recollection of sample fractions of multiple parallel channels into a minimum of outlet ports. However, 3D microfluidic channel interconnections pose a severe manufacturing challenge. We recently introduced a novel technology for the high-yield manufacturing of densely spaced miniaturized vertical vias in PDMS [4]. This method is based on the inhibition of PDMS polymerization through the local depletion of the platinum polymerization catalyst. In this work, we have improved the technique to reliably produce densely packed PDMS-vias over larger device areas. We also manufactured single inlet/two-outlet parallel-channel inertial focusing microdevices and demonstrate particle filtration in those. THEORY In Poiseuille flow, the parabolic velocity profile results in a shear-gradient-induced lift force, F LS, directed down the shear gradient towards the wall, and a wall-induced lift force, F LW, directed away from the wall. Depending on the specific particle size, channel geometry and fluidic conditions, the resulting channel cross-sectional force field, F, can exhibit specific stable regions of zero force magnitude that form equilibrium positions. Assuming point-shaped particles (Rp<<1), it has been shown that the magnitude of the force vectors F L in F scale quadratically with the particle Reynolds number, Rp, and linearly with a cross-sectional position dependent lift coefficient, fc [5]: F L =Rp 2 fc µ 2 /ρ, in which Rp=Re (a/d h ) 2 is the particle Reynolds number, Re=r U m D h /µ the channel Reynolds number, a the particle diameter, D h =2 w h/(w+h) the hydraulic diameter, w and h the width and height of the channel, U m the maximum channel velocity and µ and ρ are the viscosity and density of the fluid, respectively. Figure 1: Particle inertial focusing in flow through straight channels. (a) The shear induced lift force (F LS ) and a wall induced lift force (F LW ) acting on a particle flowing in a microchannel. (b) Illustration of the cross-sectional equilibrium positions of particles flowing through different channel geometries. Because the force on the particles scales with the fourth power of the particle size, a, the flow focusing force field is negligible for very small particles. This can be used to separate particles depending on size. At intermediate Re, particles are forced across streamlines and occupy, the equilibrium positions positioned along the centres of the faces of the microchannel walls [1]. In a square microchannel, this results in particle focusing in 4 streams, close to the centre of each channel wall (figure

1b). Changing the channel geometry to rectangular cross-section reduces the particle focusing into two streams, close to the centre of the longest channel side wall. This means that for high aspect ratio channels, i.e. with h>w, particles are found in two laterally positioned particle streams, as reported in [2]. In our study, we report flow through low aspect ratio channels, i.e. with h<w, resulting in particle focusing in two streams in single lateral focusing position along the center of channel (figure 1 b, right). MATERIALS AND METHODS Design We manufactured both single channel and parallel channel devices. All designs feature a channel length of 20 mm and height of 50 µm. The 10 mm upstream parts of the channels have a width of 70 µm, whereas the 10 mm downstream parts of the channels are tapered from width 70 µm to width 200 µm. The tapering was designed to increase the lateral spatial separation of flow streams in the channel. The multi-channel device consists of two PDMS layers, featuring a single inlet and two outlets. The top PDMS layer is designed to separate the side fractions from the channels to outlet 1 and the middle fractions from the channels to outlet 2, as shown in figure 3b. The dual PDMS layers are capped with a thick polycarbonate lid to allow easy attachment of steel tubes as fluidic ports. Fabrication of devices The single channel PDMS microdevices were fabricated using a single layer SU-8 mold. The fabrication steps for the 3D multi-channel devices are shown figure 2. A dual level SU-8 mold, pretreated with Teflon AF TM was used, in which the lower mold features define the channels (h=50 µm) and the higher mold features define the vertical vias (h= 150 µm). A flexible 250 μm thick polycarbonate (PC) plate was incubated for one hour in a solution of 4% Z-6020 silane (Dow Corning, US) in methanol and baked for 10 min at 110 C to create an amine surface coating that inhibits PDMS polymerization. PDMS prepolymer was poured onto the dual layer SU8 bottom mold (figure 2a). The PC plate was clamped onto the prepolymer, after which the prepolymer is cured for 30 min at 65 C. During curing, the polymerization is locally inhibited on top of the highest mold features (i.e. the vias positions), as described in [4] and illustrated in figure 2b. The polymerized PDMS adheres better to the PC plate than to the mold. Its flexibility allows the PC-PDMS stack to be peeled off from the mold (figure 2c). The bottom PDMS surface of the PC-PDMS stack is treated with oxygen plasma and bonded covalently to a clean and oxygen plasma treated glass slide. This ensures the adhesion between the PDMS and the glass to be higher than that between the PDMS and the PC. The flexible PC sheet is thereafter peeled off from the PDMS-glass device. The unpolymerized PDMS residues at the via positions follow the PC sheet, thus forming open vias in the PDMS (figure 2d). The top PDMS layer is prepared from a second SU8 mold and is, after oxygen plasma treatment, bonded to the bottom PDMS layer (figure 2e). A 2 mm thick PC cover lid is milled out and assembled with steel tubes. Finally, a leak-tight bond is formed between the PC lid and the PDMS-top layer (figure 2f) by: incubating the PC lid for one hour in a solution of 4% silane (Z-6020) in methanol; oxygen plasma treating the PDMS top layer; and subsequently clamping the PC lid to the PDMS at 65 C for one hour. Figure 2. Fabrication steps for the manufacturing or 3D multi channel devices. (a) The PC inhibition plate is applied on the PDMS prepolymer and clamped to the bottom layer mold. (b) During baking, the thin layer of PDMS close to the inhibition layer remains unpolymerized as compared to the PDMS bulk, which polymerizes. (c) The PC-PDMS stack is peeled of from the mold. (d) The PDMS is plama treated and permanently bonded to the glass slide, after which the PC plate is peeled off. (e) A second, top PDMS layer is aligned and plasma-bonded on top of the bottom PDMS layer. (f) A 2mm thick PC lid with attached steel tubes is bonded on top of the top PDMS layer. Experimental setup The device characterization is based on the analysis of fluorescent microspheres flowing through the channels. Internally dyed green and red fluorescent polystyrene microspheres (2, 10 and 24 μm in diameter, Thermo Scientific) were diluted to 0.1-0.5 vol % with deionized water with 1% TritonX-100 (BDH Prolabo). The solutions were pumped with a syringe pump (Harvard Apparatus PHD 2000). The device was mounted onto the stage of an inverted fluorescent microscope and fluorescent streak images were obtained. For filtration characterization, a suspension mixture of 24 μm (green) and 2 μm (red) microspheres was pumped through a 4-parallel-channel device at a flow rate of 0.8 ml/min and collected at the two outlets. The fractions were quantified by a coulter counter (Z2, Beckman Coulter, USA). RESULTS & DISCUSSION First we describe particle focusing in single channels. Thereafter, we describe the results of the manufacturing technology for the production of high-density 3D

microfluidic PDMS channels. Finally, we describe particle filtration in parallel channel devices as a proof of principle for high-throughput sample processing. Particle focusing in flows through straight channels To investigate the particle focusing characteristics, three different particles sizes (2 μm, 10 μm and 24 μm) were flown at several flow rates (3 < Re < 110) through the single channels. 3D multi channel device fabrication As illustrated in figure 2, we have adapted a previous manufacturing protocol [4] to produce vias over large areas. In contrast to previous work, we used a more flexible inhibition plate material (a thin polycarbonate sheet) on which the monolayer of the silane inhibitor was immobilized. This flexibility enabled us to successfully transfer PDMS structures with a footprint area of 900 mm2, whereas using a glass plate as inhibition plate, as described previously [4], resulted in the glass-pdms stack being stuck to the mold and practically impossible to remove without destroying the PDMS structures. Figure 4a shows the PDMS vias in an 8 parallel channel device, filled with red dye for visualization. The vias manufacturing yield was repeatedly 100%, without residual membranes blocking the vias. Figure 4b shows two layers of PDMS channels, aligned and bonded. The final step of bonding the PC lid to the top PDMS layer resulted in low yields but when successful, the bond was leak tight. A successfully fabricated 3D device using 4 parallel channels can be seen in figure 4c. Figure 3: Fluorescence images of 2 µm (left), 10 µm (middle) and 24 µm (right) particles flowing at a flow rate of 200 µl/min (corresponding Re=56 for w=70 µm) showing inertial focusing. The schematic cross-sections show the particle positions at the outlet of the channels. The 2 µm particles remain unfocused, while the 10 µm particles were focused into 4 streams and the 24 µm particles into two streams. As can be seen in figure 3, the 2 μm particles remain unfocused, while the 10 μm and 24 μm particles, initially well distributed at the inlet, are focused after 10 mm. 2 μm particles remained unfocused regardless of flow rate, suggesting an optimal particle size with respect to the channel geometry below which no focusing can occur, the latter being in agreement with previous reports [1][2]. Notably, the 10 μm particles are focused in four equilibrium positions whereas the 24 μm particles are focused into two streams at a single lateral position at the center of the channel. The occurrence of four equilibrium focusing positions has previously only been observed in square channel cross-sections [1]. The reduction of focusing particle streams from 4 to 2 when changing from a square to a rectangular channel cross-section was previously attributed to be channel geometry only, but our findings indicate a particle size dependency in addition to the channel geometry dependency. The ability to differentially focus particles at different equilibrium positions could be utilized in particle sorting applications. Figure 4: Pictures of 3D multi channel devices. (a) An image of an 8-parallel-channel device with open vias filled with red dye for visualization. (b) Image of the outlet of a 4-parallel channel device, interconnected through vias (left panel). The top PDMS layer (marked by yellow diagonal lines) is aligned and bonded onto the bottom PDMS layer. One of the vias is highlighted (right panel). (c) A 4-channel high throughput filtration device filled with red dye to show the leak-tight bonding of the PC-lid. The distance from the inlet to the outlets is 23 mm and the total 2 footprint area of the device is less than 100 mm.

High throughput particle filtration A mixture of 24 µm and 2 µm particles was pushed through the 4 parallel channel device at a flow rate of 0,8 ml/min (with corresponding Re = 56) to evaluate the separation efficiency. As expected, the 24 µm particles were focused into the lateral centre position of every channel and could be extracted through outlet 2 (figure 5a), while the 2 µm are unforced and equally distributed in both fractions. The filtration efficiency of the un-optimized flow rate was 82%,. One way to improve the efficiency is to optimize the channel geometry (length and aspect ratio) and flow rate. In addition, we observed clogging in the outlet channels of the top PDMS layer, presumably due to residues of un-polymerized PDMS. Coating the channel system can possibly solve the latter issue. The non-optimized particle filtration throughput of 0.2 ml/min in each channel, can be compared with 28 μl/min by Bhagat et al. [2] and 0,2 ml/min per-channel by Mach et al. [6] but the flow-through per microchip footprint area are however unmatched. In addition, the integration level provided by our manufacturing process enables integration of the design with other lab-on-chip components. to operate which is suitable for low-cost particle focusing, and filtration applications. ACKNOWLEDGMENT This work was performed as part of the EU sponsored FP7 project InTopSens. REFERENCES: [1] D. Di Carlo, D. Irimia, R. G. Tompkins, and M. Toner, Continuous inertial focusing, ordering, and separation of particles in microchannels, in Proceedings of the National Academy of Sciences, 2007, vol. 104, pp. 18892-18897. [2] A. A. S. Bhagat, S. S. Kuntaegowdanahalli, and I. Papautsky, Enhanced particle filtration in straight microchannels using shear-modulated inertial migration, Physics of Fluids, vol. 20, no. 10, p. 101702, 2008. [3] A. Russom, A. K. Gupta, S. Nagrath, D. D. Carlo, J. F. Edd, and M. Toner, Differential inertial focusing of particles in curved low-aspect-ratio microchannels, New Journal of Physics, vol. 11, no. 7, p. 075025, 2009. [4] C. F. Carlborg, T. Haraldsson, M. Cornaglia, G. Stemme, and W. van der Wijngaart, A High-Yield Process for 3-D Large-Scale Integrated Microfluidic Networks in PDMS, Journal of Microelectromechanical Systems, vol. 19, no. 5, pp. 1050-1057, 2010. [5] E. S. Asmolov, The inertial lift on a spherical particle in a plane Poiseuille flow at large channel Reynolds number, Journal of Fluid Mechanics, vol. 381, pp. 63-87, 1999. [6] A. J. Mach and D. Di Carlo, Continuous scalable blood filtration device using inertial microfluidics, Biotechnology and Bioengineering, vol. 107, no. 2, pp. 302-311, 2010. CONTACT * J. Hansson, tel: +46-730560805; jonhans@kth.se Figure 5: Particle filtration in parallel-channel device. (a) Fluorescent image of 24 µm and 2 µm particle suspensions flowing through the filter, showing the 24 µm particles entering to the middle outlet leading to the top layer and outlet 2. (b) The filtration efficiency for the 24 µm beads was 82%, as analyzed by a coulter counter. CONCLUSIONS We report inertial microfluidics for high-throughput particle filtration in flows through parallel channels, enabled by a scalable integrated 3D microfluidic network fabrication technology. The uncomplicated device requires neither external force fields nor mechanical parts