SOLNOI VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NMUR, / - / / N / 0 /-/ Series FTURS Series monostable spool valves / have TÜV certifi ed I 60 Functional Safety data and can be used up to SIL /K 7 The solenoid operated spool valves have threaded port connections and "NMUR" interface The same spool valve can be adapted for / N or / functions for controlling double-acting and single-acting actuators ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) an be externally piloted (external air pilot supply) to convert valve to zero minimum operation by fl ipping a gasket The solenoid valves satisfy all relevant irectives GNRL ifferential pressure - 0 bar [ bar =00 kpa] Flow (Qv at 6 bar) / = 700 l/min (NR) / = 000 l/min fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, fi ltered : - 0 to + 0 : - 0 to + 60 VMQ (silicone) + PUR (polyurethane) MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ody, end covers Stainless steel, ISI 6L Interface plates Glass-fi lled P Spool valve internal parts Stainless steel, POM ore tube Stainless steel ore and plugnut Stainless steel ore spring Stainless steel Seals & discs NR Top disc FPM isc holder POM artridge (Low ) Welded, packless ISI 0 Seat Stainless steel Seat insert POM Shading coil opper Rider ring (Low ) PTF SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) prefix optional solenoids max. (PS) level NM TX/NL (gas/dust) min. () RP-MP basic catalogue number IP6 air ( ) 7 & x d x em x m x i x n ( ) (mm) (m /h) (l/min) ~ = ~/= F NF NK M PV IS ZN S Solenoid air pilot operated - spring return (monostable) / 6 0,60 0 0 / 0 0 P - - 0 () / 6 0,60 0 0 / 0 0 P - - - - - - - G0 () / 6 0,60 0 0 / 0 0 LP - - 0 () / 6 0,60 0 0 / 0 0 LP - - - - - - - G0 () /,, 0 / 0 0 P - - 0 /,, 0 / 0 0 P - - - - - - - G0 /,, 0 / 0 0 LP - - 0 /,, 0 / 0 0 LP - - - - - - - G0 Solenoid air pilot operated and return (bistable) / 6 0,60 0 0 / 0 0 P - - 0 / 6 0,60 0 0 / 0 0 P - - - - - - - G0 / 6 0,60 0 0 / 0 0 LP - - 0 / 6 0,60 0 0 / 0 0 LP - - - - - - - G0 /,, 0 / 0 0 P - - 0 /,, 0 / 0 0 P - - - - - - - G0 /,, 0 / 0 0 LP - - 0 /,, 0 / 0 0 LP - - - - - - - G0 Select for NSI.0. or select G for ISO G (/) vailable feature vailable feature in only () ertified I 60 Functional Safety data, use suffi x "SL" () Zero minimum is only achieved if external pressure is applied UP ll leafl ets are available on: www.asco-process-scope.com LP Not vailable 0,W -,W Ultra Low Low P Not vailable 0,W -,W Reduced and Medium asic POWR LVLS - cold electrical holding values (watt) PI-6--G 00/R0
SRIS - PRFIX TL prefi x level description 6 7 LP RP MP P S U ustproof TX (N 0--) * - - - F xplosionproof - NM,, 6, 7, - - V xplosionproof - NM,, 6, 7, - 6 SS - - M ncapsulated TX + Ix (N/I 6007 / 6)* - - T Threaded conduit/hole (M0 x.) - - I S S Intrinsically safe with S coil TX (N 000) * - - - N F Flameproof - lum. TX + Ix (N/I 6007 / 6)* - - N K Flameproof - lum. TX (N 6007 / 6) * - - - P V ncapsulated TX + Ix (N/I 6007 / 6)* - - S Solenoid with spade plug connector (N 6070) - - W P Waterproof IP67 - Metal enclosure (N 6070) - - W S Waterproof IP67-6 SS enclosure (N 6070) - - W S M 6 SS "M" encl. TX + Ix (N/I 6007/6)* - - W P U ustproof TX (N 0--) - Metal enclosure * - - - W S U ustproof TX (N 0--) - 6 SS enclosure * - - - W P I S I.S. with Metal IP67 enclosure TX (N 000) * - - - W P Z N N.S. metal enclosure TX (N 00)* - - W S I S I.S. with Metal IP67-6 SS enclosure TX (N 000) * - - - W S N F Flameproof - St. steel 6 TX + Ix (N/I 6007 / 6)* - - W S Z N N.S. 6 SS enclosure TX (N 00)* - - Z N ncapsulated Non Sparking TX (N 00) * - - T Threaded conduit (/" ) - - H T lass H - High temperature, +0 ambient temp. - - - X Other special constructions - - SUFFIX TL suffi x level description 6 7 LP RP MP P M O Push type or screw type manual operator / - - S L ertifi ed I 60 Functional Safety data (Series ) () / - - PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page 7. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations table above. xample: G0 STP Select prefi x (combination). Select the appropriate operator from the specifi cations table on page and the prefi x table on page. Select for this operator in the electrical characteristics table on page : the level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. xample: M STP Select suffi x (combination) if required. xample: MO STP Select voltage. Refer to standard voltages on page. xample: 0V / 0Hz STP Final catalogue / ordering number. xample: M G0MO 0 V / 0 Hz OPTIONS & SSORIS series stainless steel pipe exhaust protector G - / 600 () 600 () / 600 () 600 () / 6007 6007 vailable feature vailable feature in only - Not available * TX solenoids are also approved according to N/I 6 (ust) and N 6- (non electrical valves) () Provided with "SL" suffix () Not to use with MO suffi x ORRING XMPLS: S G 0 0V / 0 Hz S G 0 0V / 0 Hz S G 0 SL 0V / 0 Hz S G 0 MO 0V / 0 Hz SHT 0 MO 0V / 0 Hz ISS G 0 MO V / S 0 0V / 0 Hz WPIS G 0 V / M 0 MO 0V / 0 Hz F G G 0 MO 0V / 60 Hz prefi x () pipe thread voltage basic number () suffi x () Prefi xes F and V should always be used with the letter G in the basic number. ll leafl ets are available on: www.asco-process-scope.com 6-- 00/R0
SRIS - XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature range The operator ambient temperature range is determined by the selected level (LP, RP, MP or P) and the TX safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I Standard voltages (=) V - V (~) V - V - V - 0V () /0Hz; other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/ temperature enclosure cold safety code option ~ ~ = range (TS) protection ~ = (V) (V) (W) (W) ( ) (N 60) 0 V / 0 Hz V type () asic (P) S 0, /, -0 to +7 N 6070 moulded IP6 00--7 00-- 0 SU 0, /, -0 to +7 II IP6 T 00 (~)/ (=) moulded IP6 - () - () 0 WP/WS 0, /, -0 to +7 N 6070 steel/ss IP67 00-0-7 00-0- 0 WPU/WSU 0, /, -0 to +7 II IP67 T 00 steel/ss IP67 - () - () 0 (WS)NF 0, - [-60] () -0 to +/0/60 II G/ x d II T6/T/T/x t alu./ss IP67 00-0-7-0 (WS)NF - - - /, [-60] () -0 to +0/60/7 II G/ x d II T6/T/T/x t alu./ss IP67-00-0-0 NK 0, /, -0 to +0/60 II G/ x d II+H T/x t aluminium IP6 00-0-7 00-0- 0 M/WSM 0, /, -0 to +0 II G/ x emb II T/x t steel/ss IP67 00-0-7 00-- 0 PV 0, /, -0 to +6 II G/ x mb II T(~)/T(=)/x m moulded IP6 - () - () 0 F/V 0, /, -0 to +/0 NM type 7 and mould.nm X -60-0 -70-006 06 ZN 0, /, -0 to +0 II G/ x n II T moulded IP6 - () - () 0 WP(WS)ZN 0, /, -0 to +0/60 II G/ x n II T(~)/T(=) steel/ss IP67 - () - () 0 Low (LP) S,,,,7/,7-0 to +60 N 6070 moulded IP6 00--07 00--0 07 WP/WS,,,,7/,7-0 to +60 N 6070 steel/ss IP67 00-6-07 00-6-0 0 (WS)NF - -, - /, [-60] () -0 to +7/0 II G/ x d II T6-T/x t alu./ss IP67 - () - () 0 M/WSM,,,,7/,7-0 to + II G/ x emb II T/x t steel/ss IP67 - () - () 0 PV - - -,7/,7-0 to +6 II G/ x mb II T6 / x m moulded IP6 - - () 0 F/V - - -,7/,7-0 to +60 NM type 7 and mould.nm X - - () ISS () - - - 0,/0-0 to +60 II G/ x ia II T6(G/=) moulded IP6-6-76-00 WPIS () - - - 0,/0-0 to +60 II G/ x ia II T6(G/=) acier IP67-6-00-00 0 WSIS () - - - 0,/0, -0 to +60 II G/ x ia II T6(G/=) St steel IP67-600-00 0 ZN - - -,7/,7-0 to +0 II G/ x n II T moulded IP6 - - () 07 WP(WS)ZN,,,,7/,7-0 to +60 II G/ x n II T6 steel/ss IP67 - () - () 0 prefix option safety parameters U I = () I I P I L I I (V) (m) (W) (µf) (mf) Low (LP) ISS 00, 0 0 WPIS 00, 0 0 LTRIL ONNTIONS prefix connection S, SU, ZN WP, WS, M, WSM, WPU, WSU, WPZN, WSZN, WPIS, WSIS NF, WSNF NK PV F/V ITIONL OPTIONS () The certified minimum temperature of this operator () Refer to the dimensional drawings on pages to 6. () Intrinsically safe pilots: heck the electrical characteristics in the corresponding catalogue pages (ISS/WPIS operators). () Multiple coil kits available under TX, contact us () Low Power, 0 V does not exist. Maximum voltage in is V. - Not available Spade plug connector with cable gland N70-0 (ISO 00) for cables with an outer diameter from 6 to 0 mm M0 cable gland for cables with an outer diameter from 7 to mm. With an internal and external facility for an earthing or bonding conductor /" threaded cable entry. nclosures are supplied without cable gland /" threaded cable entry. nclosures are supplied without cable gland Moulded-in cable, standard length m /" conduits, standard length cm Valves confi gured for external pilot air supply, TPL 07 Other pipe threads are available on request x mb (prefi x "PV") execution can be supplied in various cable lengths ompliance with "UL", "S" and other local approvals available on request /" (prefi x "T") and M0 x. (prefi x "T") conduits (aluminium or 6 SS) available for steel solenoid housing INSTLLTION Installation/maintenance instructions are included with each valve The solenoid valves can be mounted in any position without affecting operation I 60 Functional Safety (Suffi x SL), allowable temperature range: -0 to +60. Probability of failure on demand, contact us Spool valve supplied with two interface plates with NMUR mating surfaces. epending on function (N / or /), position one of the two plates on the spool valve body before installing on actuator It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) owel pin (if necessary), bolts and gaskets are standard supplied Threaded pipe connection identifi er is: = (NSI.0.); G = G (ISO /) Prefi x "(WS)NF" enclosure is provided with a /" threaded entry hole [optionally, M0 x, (prefix "T")] and is supplied without cable gland Prefi x "NK" enclosure is provided with a /" threaded entry hole [optionally, /" (prefi x "T") or M0 x, (prefi x "T")] and is supplied without cable gland Valves with suffi x "SL" are provided with specifi c exhaust protectors ll leafl ets are available on: www.asco-process-scope.com 6-- 00/R0
SRIS - IMNSIONS (mm), WIGHT (kg) Monostable Series istable Serie Mono/bistable 7,, 7 0 0 / x /,6 0 / x /,6 /,6, x / 7,, Interface plates mounting holes. mm dia.; Spotfacing: mm dia., depth mm; screws (Hc M x ), engaged length: 7 One mm dia. hole for dowel pin - in position : / N function plate - in position : / function plate O-ring seals (supplied) mounting holes 6, mm dia.; Spotfacing: mm dia., depth 6 mm; screws (Hc M6 x 0), engaged length: 7 TYP 0: Prefixes S: IP6, ZN: II G/, IP6, x n II, SU: II, IP6, T00 to 00 asic poxy moulded I / ISO 00 0 / 0 / 0 / 0 TYP 0: Prefixes NF/WSNF: II G/, IP67, x d II asic luminium, epoxy coated (NF) ISI 6 SS (WSNF) N/I 6007- and N/I 6-0 / 0 / 0 / 0 6 / 0 / 0 6 TYP 0: Prefix NK: II G, IP6, x d II + H asic luminium, epoxy coated N 6007- and N 6-0 / 0 / 0 / 0 TYP 0: Prefixes WP/WS: IP67, M/WSM: II G/, IP67, x emb II, WPU/WSU: II, IP67, T to 00, WPZN/WSZN: II G/, IP67, x n II asic Steel, epoxy coated (M, WP, WPU, WPZN) ISI 6 SS (WS, WSU, WSM, and WSZN) I / N 6007-7/ and N 6-0 / 0 / 0 / 0 / / /, 6, 00 ll leafl ets are available on: www.asco-process-scope.com 6 0 00/R0 6--
SRIS - IMNSIONS (mm), WIGHT (kg) TYP 0: Prefix PV: II G/, IP67, x mb II, x m asic poxy encapsulated N/I 6007- and N/I 6-0 / 0 / 0 / 0 TYP 06: Prefixes F/V: IS-6 NSI / NM type 7 and asic poxy encapsulated IS-6 NSI / NM Type 7 and NOT: applicable to solenoid only G0 / G0 / G0 / G0 / / "T" (M0x,) "T" (/ ) 6 TYP 07: Prefixes S: IP6, ZN: II G/, IP6, x n II Low poxy moulded I / ISO 00 0 / 0 / 0 / 0 TYP 0: Prefixes NF/WSNF: II G/, IP67, x d II Low luminium, epoxy coated (NF) ISI 6 SS (WSNF) N/I 6007- and N/I 6-0 / 0 / 0 / 0 / 0 / 0 6 TYP 0: Prefixes WP/WS: IP67, M/WSM: II G/, IP67, x emb II, WPU/WSU: II, IP67, T to 00, WPZN/WSZN: II G/, IP67, x n II, /WSIS: = II G/ x ia II - = II G/ x ia II Low Steel, epoxy coated (M, WP, WPU, WPZN, WPIS) ISI 6 SS (WS, WSU, WSM, WSIS and WSZN) I / N 6007-7/ and N 6-0 / 0 / 0 / 0 TYP 0: Prefix PV: II G/, IP67, x mb II, x m Low poxy encapsulated N/I 6007- and N/I 6-0 / 0 / 0 / 0 / / 0 6 ll leafl ets are available on: www.asco-process-scope.com 6-- 00/R0
SRIS - IMNSIONS (mm), WIGHT (kg) TYP : Prefixes F/V: IS-6 NSI / NM type 7 and Low poxy encapsulated IS-6 NSI / NM Type 7 and NOT: applicable to solenoid only G0 / G0 / G0 / G0 TYP : : II G/ x ia II, IP6 - : II G/ x ia II, IP6 Low Polypropylene moulded I / ISO 00 N 000 and N 0-- 0 / 0 / 0 / 0 / "T" (M0x,) "T" (/ ) / 6 67 Serie Serie weight () type prefixe option level monostable bistable 0 S / SU / ZN basic 7 0, 7 7 6, 0,,6,0, 0 NF basic - - 0 7 - -,6,,0 6,6 0 WSNF basic - - 0 7 - -,, 7,00, 0 NK basic 0 - - 7 - -,0,,0, 0 WP/WPU/WS/WSU/M/WSM basic 0 0 - - 6 7 - -,7,,0,6 0 PV basic 7, 6 0 6,,6,7,0, 06 F / V basic 7 0,, 7 00 6,,6,7,0, 07 S / ZN low 7 07, 6 6, 0,,6,0, 0 NF low - - 0 7 - -,6,,0 6,6 0 WSNF low - - 0 7 - -,, 7,00, 0 WP / WS / M / WSM / WPIS / WSIS low 0 0 - - 6 7 - -,7,,6,6 0 PV low 7 06, 6 6,,6,7,0, F / V low 7 06, 7 6,,6,7,0, ISS low 7 0, 0 6, 0,6,7,0, () Incl. coil(s) and connector(s) x d certifi ed cable gland (on request) Three-core cable, length m able gland for unarmoured cable with 7 to mm dia. sheath 6 onnector rotatable by 0 increments (cable Ø 6-0 mm) Manual operator location, suffi x MO xternal pilot air supply, / pipe onnectable pilot exhaust port Non-connectable pilot exhaust port SSORIS ø ø / / 0 / pilot exhaust protector part number 76-0-00 pilot top exhaust low (SO solenoid interface) Ø Ø - / / / - 0 exhaust protector (stainless steel) ll leafl ets are available on: www.asco-process-scope.com 6--6 00/R0
SPOOL VLVS pilot or air operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NMUR, / - / / N / 0 /-/ Series FTURS Series monostable spool valves / have TÜV certifi ed I 60 Functional Safety data and can be used up to SIL /K 7 Series versions according to TX //, for zones 0, and and series air-operated versions for zones and The solenoid operated spool valves have threaded port connections and "NMUR" interface The same spool valve can be adapted for / N or / functions for controlling double-acting and single-acting actuators ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) The solenoid valves satisfy all relevant irectives GNRL ifferential pressure - 0 bar [ bar =00 kpa] Flow (Qv at 6 bar) / = 700 l/min (NR) / = 000 l/min fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, fi ltered : - 0 to + 0 : - 0 to + 60 VMQ (silicone) + PUR (polyurethane) MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ir operated NOMO solenoid (pilot) interface (Series -) (Series ) ody, end covers Stainless steel, ISI 6L Stainless steel, ISI 6L Interface plates Glass-fi lled P Glass-fi lled P Spool valve internal parts Stainless steel, POM Stainless steel, POM Seals NR NR Pilot internal parts - Size 0 (06.0.0N), refer to catalogue pages: 7 pilot (TNK) and pilot (ISS) IR OPRT SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) prefix optional basic catalogue number max. (PS) min. air ( ) ( ) (mm) (m /h) (l/min) ~ = Pilot air operated - spring return (monostable) / 6 0,6 0 0 0-0 () /,, 0 0-0 Pilot air operated and return (bistable) / 6 0,6 0 0 0-0 /,, 0 0-0 UP LP Not vailable,6w Ultra Low Low RP-MP P Not available 0,W -,W Reduced and Medium asic POWR LVLS - cold electrical holding values (watt) NOMO SOLNOI (PILOT) INTRF SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) min. level prefix optional solenoids max. (PS) TX/NL (gas/dust) air ( ) x d x i basic catalogue number ( ) (mm) (m /h) (l/min) ~ = ~/= TNK ISS Solenoid air pilot operated - spring return (monostable) / 6 0,6 0 0 0 P - 0 () / 6 0,6 0 - LP - 0 () Solenoid air pilot operated and return (bistable) / 6 0,6 0 0 0 P - 0 / 6 0,6 0 - LP - 0 Select for NSI.0. or select G for ISO G (/) vailable feature vailable feature in only. () ertified I 60 Functional Safety data, use suffi x "SL". ll leafl ets are available on: www.asco-process-scope.com 6--7 00/R0
SRIS - PRFIX TL prefi x level description 6 7 UP LP RP P T N K Flameproof with pilot 7, TX (N 6007 / 6) * - - - I S S Intrinsically safe, pilot, TX (N 000) * - - - SUFFIX TL suffi x level description 6 7 UP LP RP P G Non-electrical, G c ()/ G c (), TX (N 6-) - - - - M S Screw type manual operator - - - M O Push type or screw type manual operator - - - S L ertifi ed I 60 Functional Safety data (Series ) () - - OPTIONS & SSORIS series stainless steel pipe exhaust protector G / 600 () 600 () / 600 () 600 () / 6007 6007 vailable feature vailable feature in only - Not available * TX solenoids are also approved according to N/I 6 (ust) and N 6- (non electrical valves) () Not to use with MS or MO suffi x () Provided with "SL" suffix PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page 7. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations tables on page 7. xample: G0 STP Select prefi x (combination). Select the appropriate operator from the tables on page 7. Select for this operator in the electrical characteristics table on page : the level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. ir operated version, does not use prefi x. xample : TNK STP Select suffi x (combination) if required. Refer to the suffi x table, respect the indicated level. G suffi x available for air operated version only (do not use manual operator suffi x). xample : MS STP Select voltage. Refer to standard voltages on page. ample : 0V / 0Hz STP Final catalogue / ordering number. xample : TNK G0MS 0 V / 0 Hz ORRING XMPLS: TNK G 0 0V / 0 Hz TNK G 0 SL V / TNK G 0 MS V / 0 Hz TNK G 0 0V / 0 Hz TNK G 0 MS V / TNK 0 0V / 0 Hz ISS G 0 V / ISS G 0 SL V / ISS G 0 MO V / ISS G 0 V / ISS G 0 MO V / G 0 G 0 G G 0 GSL G 0 G 0 G 0 G prefi x pipe thread basic number voltage suffi x ll leafl ets are available on: www.asco-process-scope.com 6-- 00/R0
SRIS - XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature The operator ambient temperature range is determined by the selected level (LP or P) and range the TX safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I Standard voltages (=) TNK : V - V ; ISS : V (~) TNK : V - V - V - 0V/0Hz - other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/cold temperature enclosure safety code option ranges (TS) protection type ~ ~ = ~ = () (V) (V) (W) (W) ( ) (N 60) - - asic (P) TNK 0, /, -0 to +60 II G/ x d II+H T/x t moulded IP6 - - 0 Low (LP) ISS ()() - - -,6-0 to +0 II G/ x ia II T6 moulded IP6 - - 0 - Not available () Refer to the dimensional drawings on page 0.. safety parameters prefix U option I = () I I P I L I I (V) (m) (W) (µf) (mf) Low (LP) ISS,6 0 0 LTRIL ONNTIONS prefix connection TNK /" threaded cable entry. nclosures are supplied without cable gland ISS Spade plug connector with cable gland N70-0 (ISO 00) for cables with an outer diameter from 6 to mm ITIONL OPTIONS Other pipe threads are available on request INSTLLTION Installation/maintenance instructions are included with each valve The spool valves can be mounted in any position without affecting operation I 60 Functional Safety (suffi x SL), allowable temperature range: -0 to +60. Probability of failure on demand, contact us Spool valve supplied with two interface plates with NMUR mating surfaces. epending on function (/ N or /), position one of the two plates on the spool valve body before installing on actuator owel pin (if necessary), bolts and gaskets are standard supplied It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) x d (prefi x "TNK") enclosure is provided with a /" threaded entry hole [optionally, /" (prefi x "T") or M0 x, (prefi x "T")] and is supplied without cable gland Threaded pipe connection identifi er is: = (NSI.0.); G = G (ISO /) Valves with suffi x "SL" are provided with a specifi c exhaust protector ll leafl ets are available on: www.asco-process-scope.com 6-- 00/R0
SRIS - IMNSIONS (mm), WIGHT (kg) Type 0-0: NOMO (Series ) 0 (06.0.0) Type 0: ir operated Series Series 67,, Interface plates mounting holes. mm dia.; Spotfacing: mm dia., depth mm; screws (Hc M x ), engaged length: 7 mm 0 / 0 0MS / 0MS G/ / x / x /,6,6 TYP 0: Prefix TNK: II G, IP6, x d II + H asic 7 pilot, light alloy luminium, epoxy coated N 6007- and N 6- G/ One mm dia. hole for dowel pin - in position : / N function plate - in position : / function plate O-ring seals (supplied) 66,7,, x / x / 0,6,6 TYP 0: Prefix ISS: Series : II G x ia II, IP6 Series : II G x ia II, IP6 Low pilot Polyamide I / ISO 00 N 000 and N 0-- 0 / 0 0MO / 0MO 0 6, 07,6, x / 7 7,, mounting holes 6, mm dia.; Spotfacing: mm dia., depth 6 mm; screws (Hc M6 x 0), engaged length: 7 mm, 0 / 0 ll leafl ets are available on: www.asco-process-scope.com 6--0 0 / 0 77, 6, 00 TYP 0: No prefix, IP6 [suffixes : G (II G c) ; SL (SIL) ; GSL (SIL, II G c) suffixe : G (II G c)] ir operated version 6, 7,,, 6 weight () type prefix option level monostable bistable 0 TNK basic, -, - 0 ISS low, -, - 0 - -,,6,7, () Incl. connector(s), except FVT. SSORIS Ø 7 0 onnector rotatable by 0 increments (cable 6-0 mm) Manual operator location x d certifi ed cable gland (on request) onnectable pilot exhaust port Non-connectable pilot exhaust port Ø - / / / - 0 exhaust protector (stainless steel) PI-06-00-G -- vailability, design and specifications are subject to change without notice. ll rights reserved. 00/R0